• 제목/요약/키워드: Detection limits

검색결과 940건 처리시간 0.03초

고성능 액체크로마토그래피를 이용한 식이보충제에서 크레아틴, 디시안디아마이드, 디하이드로트리아진의 동시분석 (Simultaneous Determination of Creatine, Dicyandiamide and Dihydrotriazine in Dietary Supplements by High Performance Liquid Chromatography)

  • 박상욱;유명상;이원재
    • KSBB Journal
    • /
    • 제29권4호
    • /
    • pp.232-238
    • /
    • 2014
  • The simultaneous determination of creatine monohydrate (CrM), dicyandiamide and dihydrotriazine in dietary supplements using reversed-phase high performance liquid chromatography (HPLC) was developed. Chromatography was performed on a Nuclosil 100-5 SA ($4.6{\times}250mm$) column with a mobile phase of 2.3% ammonium phosphate (pH 5.5), and UV detection at 224 nm, 212 nm, and 237 nm, respectively. The performance characteristics of HPLC were determined in terms of selectivity, linearity, precision, recovery, limit of detection (LOD), and limit of quantification (LOQ). The calibration curves were linear within the concentration range of $40.0{\sim}500.0{\mu}g/mL$ for creatine, $0.1{\sim}12.8{\mu}g/mL$ for dicyandiamide, and $0.05{\sim}6.4{\mu}g/mL$ for dihydrotriazine. The detection limits of the method were 1.09, 0.01, and $0.08{\mu}g/mL$ for creatine, dicyandiamide, and dihydrotriazine, respectively. The recoveries of creatine, dicyandiamide, and dihydrotriazine were 97.2~100.9, 92.3~106.5, and 97.2~105.5%, respectively. It is expected that the chromatographic analytical method developed in this study will be usefully applicable to simultaneous determination of creatine, dicyandiamide, and dihydrotriazine contained in dietary supplements.

상수도 밸브 누수 탐지용 스마트 볼트 적용의 기초 연구 (A Fundamental Study on Leak Detection System for Water Supply Valve Using Smart Bolt)

  • 박철;김영석;정해욱;최상식;이용범
    • 한국재난정보학회 논문집
    • /
    • 제16권1호
    • /
    • pp.144-154
    • /
    • 2020
  • 연구목적: 본 논문은 밸브의 누수 상태를 확인하기 위한 모니터링 시스템을 위하여 개발된 스마트 볼트의 적용성에 대한 기초 연구이다. 연구방법: 스마트 볼트에 내장된 변형률 센서와 가속도 센서를 이용하여 모의 누수 탐지 실험을 실시하였다. 연구결과: 스마트 볼트는 볼트 조임토크 기준에 부합하였으며 허용인장응력 범위 내에서 거동을 하여 상수도 체결부 적용에 부합되는 것으로 나타났다. 그리고 모의 누수 실험결과 밸브 누수 지점에선 60Hz 대역의 누수 신호가 탐지 되었으며, 메인관 누수에서는 상대적으로 고주파수 대역의 누수 신호도 탐지되었다. 결론: 모의 배관이 구속되지 않은 상태에서 전체적으로 연성진동이 이뤄진 것으로 보인다. 스마트 볼트를 통해 밸브 누수 신호의 감지에 대한 가능성을 확인하였다.

식육 및 우유 중 클로람페니콜의 미생물학적 검출법에 관한 연구 (Microbiological Assay for the Detection of Chloramphenicol in Meat and Milk)

  • 손성완;조병훈;진남섭;박종명;박근식
    • 한국식품위생안전성학회지
    • /
    • 제8권4호
    • /
    • pp.215-223
    • /
    • 1993
  • 클로람페니콜은 광벙위 항생물질로서 수의축산분야에서 널리 사용되어 왔으나 이 제제의 잠재적인 독성과 축산식풍 중 잔류성 때문에 세계 각국에서는 식용동물에서의 사용을 금지하고 있다. 따라서 이 시험에서는 미생물학척 방법에 의한 우유 및 식육 중 미량의 잔류클로람페니콜을 측정할 수 있는 방법을 확립하고자 M. luteus ATCC 9341을 시험용 균주로 설정하여 다음과 같은 결과를 얻었다. 1. 검출감도를 향상시키고자 시험명판용 Mueller-Hinton 배지의 배지량을 최소화하고 ethylacetate로 추출 농축하여 ml당 0.15/lg의 옥시테트라사이클린을 첨가한 회석용 인산염 완충액 (pH 6.0) 으로 잔류물을 용해하여 사용하였을 때 가기장 좋은 검출강도를 나타내였다. 2. 시료별 최저검출농도는 원유가 0.025 ppm이었으며, 식육은 0.05 ppm까지 검출할 수 있었다. 3. 시료별 평균 회수율은 원유가 68.5%이었으며, 쇠고기, 돼지고기 및 닭고기는 각각 65.1%. 63.8% 및 59.4%이었다. 이들 시료의 회수율에 대한 변이계수 (CV)는 1.8~15.1%이었다.

  • PDF

실시간중합효소연쇄반응을 이용한 유전자변형 콩 가공식품의 정량분석 (Quantitative Analysis of Genetically Modified Soybean in Processed Foods Using Real-time PCR)

  • 민동명;김묘영;정순일;허문석;김진국;김해영
    • 한국식품과학회지
    • /
    • 제36권5호
    • /
    • pp.723-727
    • /
    • 2004
  • 콩 가공식품인 두유, 두부, 비지에서 유전자변형 콩에 삽입된 epsps 유전자의 검출과 정량을 위해 정성과 정량 PCR 방법을 수행하였다. 두유, 두부, 비지에서 유전자변형 콩의 검출은 삽입된 epsps 유전자의 증폭이 크기가 121bp와 330bp가 생성될 수 있는 두 종류의 primer들을 이용하여 0.01%까지 확인하였다. 정량방법은 1, 3, 5%의 유전자변형 콩이 포함된 시료들을 실시간 PCR을 사용하여 유의성 있는 결과를 얻었다. 이러한 결과들은 실시간 PCR 방법을 사용하여 가공식품 내에서 정량적으로 유전자변형 콩을 정량하는데 적용될 수 있음을 보였다.

CNN 기반의 실시간 DNS DDoS 공격 탐지 시스템 (CNN Based Real-Time DNS DDoS Attack Detection System)

  • 서인혁;이기택;유진현;김승주
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제6권3호
    • /
    • pp.135-142
    • /
    • 2017
  • DDoS (Distributed Denial of Service)는 대량의 좀비 PC를 이용하여 공격 대상 서버에 접근하여 자원을 고갈시켜 정상적인 사용자가 서버를 이용하지 못하게 하는 공격이다. DDoS 공격발생 사례가 꾸준히 증가하고 있고, 주요 공격대상은 IT 서비스, 금융권, 정부기관이기 때문에 DDoS를 탐지하는 것이 중요한 이슈로 떠오르고 있다. 본 논문에서는 DNS 서버를 이용하여 패킷을 증폭시키는 DNS DDoS 공격 즉, DNS Amplification 공격(이하 DNS 증폭 공격)을 Deep Learning (이하 딥 러닝)을 활용해 실시간으로 탐지하는 방법에 대해 소개한다. 기존 연구들의 한계점을 극복하기 위하여 실험망 환경의 데이터가 아닌 실 환경 데이터를 혼합하여 탐지 시스템을 학습하였다. 또한 이미지 인식에 주로 사용되는 Convolutional Neural Network (이하 CNN)을 이용하여 딥 러닝 모델을 구축하였다.

Molecular Markers for Detecting a Wide Range of Trichoderma spp. that Might Potentially Cause Green Mold in Pleurotus eryngii

  • Lee, Song Hee;Jung, Hwa Jin;Hong, Seung-Beom;Choi, Jong In;Ryu, Jae-San
    • Mycobiology
    • /
    • 제48권4호
    • /
    • pp.313-320
    • /
    • 2020
  • In Pleurotus sp., green mold, which is considered a major epidemic, is caused by several Trichoderma species. To develop a rapid molecular marker specific for Trichoderma spp. that potentially cause green mold, eleven Trichoderma species were collected from mushroom farms and the Korean Agricultural Culture Collection (KACC). A dominant fungal isolate from a green mold-infected substrate was identified as Trichoderma pleuroticola based on the sequences of its internal transcribed spacer (ITS) and translation elongation factor 1-α (tef1) genes. In artificial inoculation tests, all Trichoderma spp., including T. atroviride, T. cf. virens, T. citrinoviride, T. harzianum, T. koningii, T. longibrachiatum, T. pleurotum, and T. pleuroticola, showed pathogenicity to some extent, and the observed symptoms were soaked mycelia with a red-brown pigment and retarded mycelium regeneration. A molecular marker was developed for the rapid detection of wide range of Trichoderma spp. based on the DNA sequence alignment of the ITS1 and ITS2 regions of Trichoderma spp. The developed primer set detected only Trichoderma spp., and no cross reactivity with edible mushrooms was observed. The detection limits for the PCR assay of T. harzianum (KACC40558), T. pleurotum (KACC44537), and T. pleuroticola (CAF-TP3) were found to be 500, 50, and 5 fg, respectively, and the detection limit for the pathogen-to-host ratio was approximately 1:10,000 (wt/wt).

GC-MS를 이용한 사람 뇨시료 중 비만치료제 분석 및 비만치료제 남용 현황의 법과학적 고찰 (Development of a Simultaneous Detection and Quantification Method of Anorectics in Human Urine Using GC-MS and its Application to Legal Cases)

  • 최혜영;이재신;장문희;양원경;김은미;최화경
    • 약학회지
    • /
    • 제57권6호
    • /
    • pp.420-425
    • /
    • 2013
  • Phentermine (PT) and phenmetrazine (PM) have been widely used as anti-obesity drugs. These drugs should be used with caution due to its close relation to amphetamine in its structure and toxicity. PT and PM, amphetamine-type anorectics, have recently been considered as alternatives for methamphetamine abuse in Korea. In addition, the misuse and abuse of PT and PM obtained by illegal sources such as the internet become a serious social problem. In the present study, a simultaneous detection and quantification method for determining PT and PM in human urine was developed and validated according to the international guidelines. The urine samples were screened using a fluorescence polarization immunooassay and analyzed by gas chromatography mass spectrometry (GC-MS) after extraction using automatic solid phase extraction (SPE) with a mixed-mode cation exchange cartridge and derivatization with pentafluoropropionic anhydride (PFPA). The validation results for selectivity, linearity, limits of detection (LOD) and quantification (LOQ), intra- and inter-assay precision and accuracy and recovery were satisfactory. The validated method was successfully applied to authentic urine samples collected from 38 drug abuse suspects. PT and/or PM were identified with or without methamphetamine in urine samples. Abuse of PT and PM have increased continuously in Korea, therefore, closer supervision of the inappropriate use of anoretics is necessary.

자동 위상 이동을 이용한 계통 연계형 태양광 발전 시스템의 고립운전 검출기법 (Islanding Detection Method for Grid-connected PV System using Automatic Phase-shift)

  • 윤중혁;최종우;소정훈;유권종;김흥근
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.107-114
    • /
    • 2007
  • 계통 연계형 태양광 발전 시스템이 정전 혹은 사고 등으로 계통으로부터 분리되었을 때 태양광 발전 시스템이 배전선 부하를 떠맡아 운전을 계속하는 현상을 고립운전이라 하는데 이런 상태가 지속되면 선로 유지보수자의 안전사고를 야기할 수 있으며 전기설비에 나쁜 영향을 줄 수도 있다. 수동 검출법은 연계점(PCC:Point of Common Coupling)의 전압이나 주파수를 측정하여 한계치를 벗어나면 고립운전으로 판단하는데 RLC 부하의 유효전력과 무효전력이 각각 PV 시스템의 유효전력, 무효전력과 서로 비슷하면 검출할 수 없다. 이 경우 고립운전을 검출하기 위한 다양한 능동 검출법이 제안되었으며 가장 효과적인 방법은 미국 샌디아 연구실(Sandia National Lab)에서 제안한 SFS법(Sandia Frequency Shift method)이다. 본 논문에서는 자동 위상 이동을 이용한 새로운 능동 검출기법을 제안하고 Matlab 시뮬레이션과 실험을 통하여 타당성을 검증하였다.

Determination of Trichlorfon Pesticide Residues in Milk via Gas Chromatography with μ-Electron Capture Detection and GC-MS

  • Hem, Lina;Khay, Sathya;Choi, Jeong-Heui;Morgan, E.D.;El-Aty, A.M. Abd;Shim, Jae-Han
    • Toxicological Research
    • /
    • 제26권2호
    • /
    • pp.149-155
    • /
    • 2010
  • The pesticide trichlorfon is readily degraded under experimental conditions to dichlorvos. A method has therefore been developed by which residues of trichlorfon in milk are determined as dichlorvos, using gas chromatography with ${\mu}$-electron capture detection. The identification of dichlorvos was confirmed by mass spectrometry. Milk was extracted with acetonitrile followed by centrifugation, freezing lipid filtration, and partitioning into dichloromethane. The residue after partitioning of dichloromethane was dissolved in ethyl acetate for gas chromatography. Recovery concentration was determined at 0.5, 1.0, and 2.0 of times the maximum permitted residue limits (MRLs) for trichlorfon in milk. The average recoveries (n = 6) ranged from 92.4 to 103.6%. The repeatability of the measurements was expressed as relative standard deviations (RSDs) ranging from 3.6%, to 6.7%. Limit of detection (LOD) and limit of quantification (LOQ) were 3.7 and $11.1{\mu}g/l$, respectively. The accuracy and precision (expressed as RSD) were estimated at concentrations from 25 to $250{\mu}g/l$. The intra- and inter-day accuracy (n = 6) ranged from 89.2% to 91% and 91.3% to 96.3%, respectively. The intra- and inter-day precisions were lower than 8%. The developed method was applied to determine trichlorfon in real samples collected from the seven major cities in the Republic of Korea. No residual trichlorfon was detected in any samples.

An HPLC-UV-based quantitative analytical method for Chrysanthemum morifolium: development, validation, and application

  • Jung, Dasom;Jin, Yan;Kang, Seulgi;Lee, Heesoo;Park, Keunbae;Li, Ke;Kim, Jin Hak;Geum, Jeong Ho;Lee, Jeongmi
    • 분석과학
    • /
    • 제32권4호
    • /
    • pp.139-146
    • /
    • 2019
  • A simple and reliable analytical method based on high-performance liquid chromatography-ultraviolet detection was established for the analysis of the flowers of Chrysanthemum morifolium (CM). Luteolin-7-O-glucoside (LU7G) was chosen as a target analyte considering its content, availability, and ease of analysis. Chromatographic separation of LU7G was achieved using a Phenomenex Gemini $C_{18}$ column ($250{\times}4.6mm$, $5{\mu}m$) run with a mobile phase consisting of 0.5 % acetic acid in water and 0.5 % acetic acid in acetonitrile at a flow rate of $1.0mL\;min^{-1}$. The detection wavelength and column temperature were set at 350 nm and $40^{\circ}C$, respectively. Method validation was performed according to the AOAC guidelines and the method was specific, linear ($R^2=0.9991$ for $50-300{\mu}g\;mL^{-1}$), precise (${\leq}3.91%$RSD), and accurate (100.1-105.7 %). The limits of detection and quantification were 3.62 and $10.96{\mu}g\;mL^{-1}$, respectively. The established method was successfully applied to determine the contents of LU7G in various batches of bulk CM extracts and labscale CM extract. The developed method is a readily applicable method for the quality assessment of CM and its related products.