• 제목/요약/키워드: Detection limits

검색결과 940건 처리시간 0.027초

Performance of Self-Manufactured Ion Selective Microelectrode (ISME) for Continuous Monitoring of Ammonia and Nitrate Ions

  • Byun, Im-Gyu
    • Journal of Environmental Science International
    • /
    • 제21권12호
    • /
    • pp.1449-1454
    • /
    • 2012
  • The ion selective microelectrodes (ISME) have been applied to observe the continuous profiles of NO3-N and NH4-N in bulk solutions or biofilms. In order to evaluate the performance and applicability of ion concentration measuring system, the characteristics, such as slope of calibration curve, detection limit and potentiometric selectivity coefficient were investigated. The slopes of calibration curve showed high degree of correspondence for each target ion concentrations. And the detection limits of nitrate and ammonia ion selective microelectrode were 10-4.7 M and 10-4.4 M, respectively. These ion selective microelectrodes were proved that their own performance could be maintained for 16 days after making. NO3-N and NH4-N selective microelectrodes were also adapted to detect the continuous ion profiles of cilia media packed MLE (Modified Ludzack-Ettinger) process. And the monitored nitrate and ammonia ion profiles with the ion selective microelectrode were stable and well corresponded to the results with conventional ion chromatograph. However, the electric potential was unstable until 8 hr because of the unknown noise. The tip shape and performance of the ion selective microelectrode was stably kept over 2 days continuous monitoring.

Simple and Rapid Detection of Vancomycin-Resistance Gene from Enterococci by Loop-Mediated Isothermal Amplification

  • Baek, Yun Hee;Hong, Seung Bok;Shin, Kyeong Seob
    • Biomedical Science Letters
    • /
    • 제26권3호
    • /
    • pp.149-156
    • /
    • 2020
  • We developed a simple and rapid method for detecting vancomycin resistance genes, such as vanA and vanB, using loop-mediated isothermal amplification (LAMP). To identify not only vancomycin resistance genes, but also the genus Enterococcus, primers were designed for vanA, vanB, and 16S rRNA. Screening for vancomycin susceptibility in Enterococcus was performed using Etest (bioMérieux Inc). The results of the LAMP assay were compared to those of real-time RT-PCR. The optimal conditions for the LAMP assay were 65℃ for 60 min. The detection limits of the LAMP assay for vanA, and vanB were 2 × 102 copies/reaction. Compared to RT-PCR, the sensitivities and specificities of LAMP for 16S rRNA, vanA, and vanB were 100/100%, 100/100%, and 100/100%, respectively. The vanA genotype-vanB phenotype accounted for 57.5% (46/80) of the vancomycin-resistant Enterococci samples collected from 2016 to 2019. In conclusion, the LAMP assay developed in this study showed high sensitivity and specificity for vancomycin-resistant genes. Moreover, due to the simplicity and rapidity of the LAMP assay, its use can be very useful in clinical microbiology laboratories.

ASM Algorithm Applid to Image Object spFACS Study on Face Recognition (영상객체 spFACS ASM 알고리즘을 적용한 얼굴인식에 관한 연구)

  • Choi, Byungkwan
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • 제12권4호
    • /
    • pp.1-12
    • /
    • 2016
  • Digital imaging technology has developed into a state-of-the-art IT convergence, composite industry beyond the limits of the multimedia industry, especially in the field of smart object recognition, face - Application developed various techniques have been actively studied in conjunction with the phone. Recently, face recognition technology through the object recognition technology and evolved into intelligent video detection recognition technology, image recognition technology object detection recognition process applies to skills through is applied to the IP camera, the image object recognition technology with face recognition and active research have. In this paper, we first propose the necessary technical elements of the human factor technology trends and look at the human object recognition based spFACS (Smile Progress Facial Action Coding System) for detecting smiles study plan of the image recognition technology recognizes objects. Study scheme 1). ASM algorithm. By suggesting ways to effectively evaluate psychological research skills through the image object 2). By applying the result via the face recognition object to the tooth area it is detected in accordance with the recognized facial expression recognition of a person demonstrated the effect of extracting the feature points.

Assessment of total is ocyanates by OSHA and NIOSH analytical methods : accuracy and precision and airborne concentrations by process (NIOSH와 OSHA 측정 방법을 이용한 이소시아네이트류 발생 공정별 농도 분포 평가)

  • Kang, Hyoung Kyoung;Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제9권2호
    • /
    • pp.1-18
    • /
    • 1999
  • The purpose of this study was to compare performances of two analytical methods, the OSHA 42 and the NIOSH 5522, of quantifying total isocyanates in air. These methods were compared in terms of accuracy and precision and the detection limits using four(4) spiked samples in each of four(4) concentration levels which ranged from 0.25 to 2.0 times of the ACGIH TLV-TWA. In addition, two methods were used to as sess airborne concentrations of total isocyanates at the following processes including autobody spray painting, furniture spray painting, polyurethane foaming, urethane adhesion, UV coating, and pigment mixing. The results of this study showed that the NIOSH 5522 method was better than the OSHA 42 method in terms of accuracy, precis ion, and detection limit for quantifying airborne total isocyanates. It was also clear that the NIOSH method was capable of detecting not only monomeric but also non-monomeric isocyanates. The results of air concentrations of total isocyanates among processes studied indicate that some processes may exceed the recommended level of isocyanates. In addition, to evaluate toxicological effects of total isocyanates, it is recommended to consider additive effects of isocyanates present in mixtures.

  • PDF

A Study on the Carbamate Pesticide Residues in Domestic and Imported Crops in Chonnam Province (전라남도에서 유통중인 국내산 및 수입산 곡류 중의 카바메이트제 농약 잔류 실태 연구)

  • 김영국
    • The Korean Journal of Food And Nutrition
    • /
    • 제13권2호
    • /
    • pp.164-170
    • /
    • 2000
  • 10 carbamate pesticides were surveyed in domestic and imported green peas, beans, red beans from March 1999 through December 1999. Samples were collected from Gwangju, Mokpo, Suncheon and Yosoo grain markets. This study was performed by post-column ο-phthalaldehyde and 2-mercaptoethanol prior to HPCL fluorophore detection. Pesticides were found in 14 of 80 samples(17.5%). The kinds of pesticide detected in green peas were methomyl, MTMC, carbaryl, those in sesames were oxamyl, carbofuran, carbaryl, 1-naphthol, MIPC, those in beans were oxamyl, MTMC, carbaryl and those in red beans were MTMC, carbaryl. The range of residues detected in green peas, sesames, beans and red beans were 0.002∼0.025ppm, 0.001∼0.469ppm, 0.005∼0.356ppm and 0.017∼0.125ppm, respectively. The most frequently detected pesticides were MTMC(6 times) and carbaryl(5 times), while aldicarb, PHC and BPMC were no detected in all samples. Detection frequencies of carbamate pesticides in imported crops were higher than those in domestic ones except red beans. Only one result of oxamyl residues determined in imported bean was higher than the proposed maximum residue limits of Codex, which was 0.356ppm.

  • PDF

The Significance of the Analytical Sciences In Environmental Assessment

  • Chung, Yong;Ahn, Hye-Won
    • Analytical Science and Technology
    • /
    • 제8권4호
    • /
    • pp.1079-1087
    • /
    • 1995
  • The quality of human life is directly related to the quality of the environment. To assess environmental quality we must first determine the MCLG(Maximum Contaminant Level Goal), MCL(Maximum Contaminant Level), environmental impact and so on. The MCLG is the concentration at which no known adverse health effects occur. The MCLG is determined by risk assessment identifying which process is hazardous assessing, dose-response, human exposure, and characteristics of risk. With consideration of analytical methods, treatment technology, cost and regulatory impact, the MCL is set as close to the MCLG as possible. In this way, determination of the concentration and national distribution of contaminants is important for assessment of environmental quality The analytical sciences pose potential problems in assessing environmental quality. Continuing improvement in the performance of analytical instruments and operating technique has been lowering the limits of detectability. Contaminant concentration below the detection limit has usually been reported as ND(Not-Detected) and this has often been misunderstood as equivalent to zero. Because of this, more the contaminant concentration in the past was below the detection limit, whereas contaminants can be quantified now even though the contaminant concentration might remain the same or may even have decreased. In addition, environmental sampling has various components due to heterogeneous matrices. These samples are used to overestimate the concentration of the contaminant due to large variability, resulting in excess readings for MCL. In this paper, the significance of the analytical sciences is emphasized in both a conceptual and a technical approach to environmental assessment.

  • PDF

Recognizing Human Facial Expressions and Gesture from Image Sequence (연속 영상에서의 얼굴표정 및 제스처 인식)

  • 한영환;홍승홍
    • Journal of Biomedical Engineering Research
    • /
    • 제20권4호
    • /
    • pp.419-425
    • /
    • 1999
  • In this paper, we present an algorithm of real time facial expression and gesture recognition for image sequence on the gray level. A mixture algorithm of a template matching and knowledge based geometrical consideration of a face were adapted to locate the face area in input image. And optical flow method applied on the area to recognize facial expressions. Also, we suggest hand area detection algorithm form a background image by analyzing entropy in an image. With modified hand area detection algorithm, it was possible to recognize hand gestures from it. As a results, the experiments showed that the suggested algorithm was good at recognizing one's facial expression and hand gesture by detecting a dominant motion area on images without getting any limits from the background image.

  • PDF

A Solid-Phase Extraction Method for Analyzing Trace Amounts of Polychlorinated Dibenzo-p-Dioxins and Dibenzofurans in Waste Water

  • Park, Deok-Hie;Youn, Yeu-Young;Choi, Jae-Won;Lim, Young-Hee;Cho, Hye-Sung
    • Mass Spectrometry Letters
    • /
    • 제2권1호
    • /
    • pp.12-15
    • /
    • 2011
  • The Korean government has regulated emission of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in waste water of manufacturing facilities producing chlorinated compounds since 2009. As this regulation is expected to be reinforced in 2013 to 50 pg I-TEQ/L, a large sample volume is required for the analysis of trace amounts of PCDD/Fs in waste water. Liquid-liquid extraction (LLE) is used to extract PCDD/Fs from aqueous samples; however, its low efficiency makes it inadequate for analyzing large sample volumes. Herein, we present a disk-type solid-phase extraction (SPE) method for the analysis of dioxin at a part per quadrillion level in waste water. This SPE system contains airtight glass covers with a decompression pump, which enables continuous semi-automated extraction. Small (0.5 L) and large (7 L) samples were extracted using LLE and SPE methods, respectively. The method detection limits (MDLs) were 0.001.0.25 and 0.015.4.1 pg I-TEQ/L for the SPE and LLE methods, respectively. The concentrations of detected congeners with both methods were similar. However, the concentrations of several congeners that were not detected with the LLE method were quantified using the SPE method.

Simultaneous Electrochemical Determination of Hydroquinone, Catechol and Resorcinol at Nitrogen Doped Porous Carbon Nanopolyhedrons-multiwall Carbon Nanotubes Hybrid Materials Modified Glassy Carbon Electrode

  • Liu, Wei;Wu, Liang;Zhang, Xiaohua;Chen, Jinhua
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권1호
    • /
    • pp.204-210
    • /
    • 2014
  • The nitrogen doped porous carbon nanopolyhedrons (N-PCNPs)-multi-walled carbon nanotubes (MWCNTs) hybrid materials were prepared for the first time. Combining the excellent catalytic activities, good electrical conductivities and high surface areas of N-PCNPs and MWCNTs, the simultaneous determination of hydroquinone (HQ), catechol (CC) and resorcinol (RE) with good analytical performance was achieved at the N-PCNPs-MWCNTs modified electrode. The linear response ranges for HQ, CC and RE are 0.2-455 ${\mu}M$, 0.7-440 ${\mu}M$ and 3.0-365 ${\mu}M$, respectively, and the detection limits (S/N = 3) are $0.03{\mu}M$, $0.11{\mu}M$ and $0.38{\mu}M$, respectively. These results are much better than that obtained on some graphene or CNTs-based materials modified electrodes. Furthermore, the developed sensor was successfully applied to simultaneously detect HQ, CC and RE in the local river water samples.

Application of Methane Mixed Plasma for the Determination of Ge, As, and Se in Serum and Urine by ICP/MS

  • Park, Kyung-Su;Kim, Sun-Tae;Kim, Young-Man;Kim, Yun-je;Lee, Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권3호
    • /
    • pp.285-290
    • /
    • 2003
  • An analytical method for the simultaneous determination of trace Ge, As and Se in biological samples by inductively coupled plasma/mass spectrometry has been investigated. The effects of added organic gas into the coolant argon gas on the analyte signal were studied to improve the detection limit, accuracy and precision. The addition of a small amount of methane (10 mL/min.) into the coolant gas channel improved the ionization of Ge, As and Se. The analytical sensitivity of the proposed Ar/CH₄system was superior by at least two-fold to that of the conventional Ar method. In the present method, the detection limits obtained for Ge, As and Se were 0.014, 0.012 and 0.064 ㎍/L, respectively. The analytical reliability of the proposed method was evaluated by analyzing the certified standard reference materials (SRM). Recoveries of 99.9% for Ge, 103% for As, 96.5% for Se were obtained for NIST SRM of freeze dried urine sample. The proposed method was also applied to the biological samples.