• Title/Summary/Keyword: Detection Ratio

Search Result 1,989, Processing Time 0.028 seconds

Cooperative Spectrum Sensing Via Sequential Detection: A Method to Reduce the Sensing Time

  • Thanh, Truc Tran;Kong, Hyung-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.3
    • /
    • pp.196-202
    • /
    • 2012
  • Spectrum sensing is one of the most important functions in cognitive radio systems. In this paper, we focus on reducing the sensing time in a cooperative spectrum sensing paradigm. In the proposed scheme, a sequential detection technique is employed to provide a robust and quick detection system. Each of the secondary users measures the log-likelihood probability of the received signals and then sequentially reports to the base station. Here, the maximum ratio combining (MRC) technique is employed to reduce the average sample number (ASN) in order to reduce the sensing time. This proposed scheme is analyzed and simulated to illustrate the performance in comparison with the other given methods. Analysis and simulation are provided to validate the proposed method.

Achievable Ergodic Capacity of a MIMO System with a MMSE Receiver

  • Kim, Jae Hong;Kim, Nam Shik;Song, Bong Seop
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.349-352
    • /
    • 2014
  • This paper considers the multiple-input multiple-output (MIMO) system with linear minimum mean square error (MMSE) detection under ideal fast fading. For $N_t$ transmit and $N_r({\geq}N_t)$ receive antennas, we derive the achievable ergodic capacity of MMSE detection exactly. When MMSE detection is considered in a receiver, we introduce a different approach that gives the approximation of a MIMO channel capacity at high signal-to-noise ratio (SNR). The difference between the channel capacity and the achievable capacity of MMSE detection converges to some constant that depends only on the number of antennas. We validate the analytical results by comparing them with Monte Carlo simulated results.

Detection of Changes of Mean Nonconformities per Unit in the u Control Chart (u 관리도에서 단위당결점수 변화 탐지)

  • Chang, Kyung;Yang, Moon-Hee
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.20 no.43
    • /
    • pp.205-209
    • /
    • 1997
  • One objective of the u control chart is to detect changes of mean nonconformities per unit occurred owing to various causes. This paper shows the detection probability using the Poisson distribution for various parameters, that is, subsample size n, mean nonconformities per unit $u_o$, and $u_o's$ change ratio k. We find that (1) as $u_o$ increases the smaller n is required for the same detection probability and the same change ratio; (2) as k gets away from 1 the smaller n is required; (3) the bigger n is required for the bigger detection probability. Several tables are given from our findings and are hoped to be used as guidelines for u chart users.

  • PDF

Using Change-Point Detection Tests to detect the Korea Economic Crisis of 1997

  • Oh, Kyong-Joo
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2004.10a
    • /
    • pp.25-32
    • /
    • 2004
  • In this study, we use various change-point detection methods to detects Korea economic crisis of 1997, and then compares their performance. In change-point detection method, there are three major categories: (1) the parametric approach, (2) the nonparametric approach, and (3) the model-based approach. Through the application to Korea foreign exchange rate during her economic crisis, we compare the employed change-point detection methods and, furthermore, determine which of them performs better.

  • PDF

Comparing Change-Point Detection Methods to Detect the Korea Economic Crisis of 1997

  • Oh, Kyong-Joo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.3
    • /
    • pp.585-592
    • /
    • 2004
  • This study detects Korea economic crisis of 1997 using various change-point detection methods and then compares their performance. In change-point detection method, there are three major categories: (1) the parametric approach, (2) the nonparametric approach, and (3) the model-based approach. Through the application to Korea foreign exchange rate during her economic crisis, we compare the employed change-point detection methods and, furthermore, determine which of them performs better.

  • PDF

The MSDD Diversity Receiver Algorithm for a High Speed Burst Modem (고속 버스트 모뎀을 위한 MSDD Diversity 수신 알고리즘)

  • 김재형;이영철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.281-288
    • /
    • 2004
  • In this paper, we consider the diversity combining method for multiple symbol differential detection (MSDD) over the slow fading diversity channel. Though the performance of the optimum maximum-likelihood sequence estimator for MSDD approaches the performance of maximal-ratio combining with differential encoding, the complexity increases exponentially as the size of MSDD block is increased. This new pre-combining method can make use of the efficient MSDD algorithm that has a complexity increasing linearly with the block length or MSDD. Thus, in many wireless scenarios where it is not possible to perform coherent detection. this pre-combined diversity MSDD can be applied to obtain substantial gain compare to conventional differential detection.

Non-Destructive Detection of Hydride Blister in PHWR Pressure Tube Using an Ultrasonic Velocity Ratio Method

  • Cheong Yong-Moo;Lee Dong-Hoon;Kim Sang-Jae;Kim Young-Suk
    • Nuclear Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.369-377
    • /
    • 2003
  • Since Zr-2.5Nb pressure tubes have a high risk for the formation of blisters during their operation in pressurized heavy water reactors, there has been a strong incentive to develop a method for the non-destructive detection of blisters grown on the tube surfaces. However, because there is little mismatch in acoustic impedance between the hydride blisters and zirconium matrix, it is not easy to distinguish the boundary between the blister and zirconium matrix with conventional ultrasonic methods. This study has focused on the development of a special ultrasonic method, so called ultrasonic velocity ratio method for a reliable detection of blisters formed on Zr-2.5Nb pressure tubes. Hydride blisters were grown on the outer surface of the Zr-2.5Nb pressure tube using a cold finger attached to a steady state thermal diffusion equipment. To maximize a difference in the ultrasonic velocity in hydride blisters and the zirconium matrix, the ultrasonic velocity ratio of longitudinal wave to shear wave, $V_L/V_S$, has been determined based on the flight time of the longitudinal echo and reflected shear echo from the outer surface of the tubes. The feasibility of the ultrasonic velocity ratio method is confirmed by comparing the contour plots reproduced by this method with those of the blisters grown on the Zr-2.5Nb pressure tubes.

Target Detection Performance in a Clutter Environment Based on the Generalized Likelihood Ratio Test (클러터 환경에서의 GLRT 기반 표적 탐지성능)

  • Suh, Jin-Bae;Chun, Joo-Hwan;Jung, Ji-Hyun;Kim, Jin-Uk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.5
    • /
    • pp.365-372
    • /
    • 2019
  • We propose a method to estimate unknown parameters(e.g., target amplitude and clutter parameters) in the generalized likelihood ratio test(GLRT) using maximum likelihood estimation and the Newton-Raphson method. When detecting targets in a clutter environ- ment, it is important to establish a modular model of clutter similar to the actual environment. These correlated clutter models can be generated using spherically invariant random vectors. We obtain the GLRT of the generated clutter model and check its detection probability using estimated parameters.

Detection and interpretation of wan-maeck by the pulse diagnostic apparatus -on the pulse/respiration rate- (완맥(緩脈)의 동서의학적(東西醫學的) 해석 -맥율(脈率)을 중심으로-)

  • Park, Young-Bae;Kang, Sung-Keel;Kim, Chang-Hwan;Koh, Hyung-Kyun;Kim, Yong-Suk;Lee, Yun-Ho;Kim, Sung-Woon;Huh, Wung;Youn, Chung-Hwa
    • The Journal of Korean Medicine
    • /
    • v.18 no.1
    • /
    • pp.143-156
    • /
    • 1997
  • This report was conducted to quantify the pulse/respiration ratio and set up the normal range of wan-maeck(緩脈). In order to objectify the pulse diagnosis and use as basic clinical index of Cold-Hot diagnosis, we developed the hardware and software for detection and interpretation of pulse/respiration ratio, pulse/expiration ratio, pulse/respiration ratio, inspiration time, expiration time, respiration frequency, respiration time, duration of one pulse and pulse and pulse rate per minute, The results were as follows; pulse/respiration ratio is $4.30{\pm}1.03$ times, pulse/respiration ratio is $1.60{\pm}0.32$ times, pulse/respiration ratio is $2.37{\pm}0.75$ times, inspiration time is $1.35{\pm}0.20$ sec, expiration time is $1.89{\pm}0.39$ sec, respiration frequency is $17.16{\pm}3.49$ times/min, total respiration time is $3.63{\pm}0.71$ sec, duration of a pulse is $0.86{\pm}0.15$ sec, pulse rate is $71.51{\pm}12.30$ times/min.

  • PDF

Development of Real-time QRS-complex Detection Algorithm for Portable ECG Measurement Device (휴대용 심전도 측정장치를 위한 실시간 QRS-complex 검출 알고리즘 개발)

  • An, Hwi;Shim, Hyoung-Jin;Park, Jae-Soon;Lhm, Jong-Tae;Joung, Yeun-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.280-289
    • /
    • 2022
  • In this paper, we present a QRS-complex detection algorithm to calculate an accurate heartbeat and clearly recognize irregular rhythm from ECG signals. The conventional Pan-Tompkins algorithm brings false QRS detection in the derivative when QRS and noise signals have similar instant variation. The proposed algorithm uses amplitude differences in 7 adjacent samples to detect QRS-complex which has the highest amplitude variation. The calculated amplitude is cubed to dominate QRS-complex and the moving average method is applied to diminish the noise signal's amplitude. Finally, a decision rule with a threshold value is applied to detect accurate QRS-complex. The calculated signals with Pan-Tompkins and proposed algorithms were compared by signal-to-noise ratio to evaluate the noise reduction degree. QRS-complex detection performance was confirmed by sensitivity and the positive predictive value(PPV). Normal ECG, muscle noise ECG, PVC, and atrial fibrillation signals were achieved which were measured from an ECG simulator. The signal-to-noise ratio difference between Pan-Tompkins and the proposed algorithm were 8.1, 8.5, 9.6, and 4.7, respectively. All ratio of the proposed algorithm is higher than the Pan-Tompkins values. It indicates that the proposed algorithm is more robust to noise than the Pan-Tompkins algorithm. The Pan-Tompkins algorithm and the proposed algorithm showed similar sensitivity and PPV at most waveforms. However, with a noisy atrial fibrillation signal, the PPV for QRS-complex has different values, 42% for the Pan-Tompkins algorithm and 100% for the proposed algorithm. It means that the proposed algorithm has superiority for QRS-complex detection in a noisy environment.