• Title/Summary/Keyword: Detached

Search Result 1,026, Processing Time 0.026 seconds

A Study on the Energy Consumption and Greenhouse Gas Emission of the Detached Houses in Daegu (대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구)

  • Kim, Yu-Lan;Yoon, Hae-Kyung;Kim, Ju-Young;Jeon, Gyu-Yeob;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.22 no.2
    • /
    • pp.35-42
    • /
    • 2011
  • In the energy consumption of buildings in Korea, the housing sector accounts for 53% of a total energy consumption. Although the researches of energy consumption on the new detached houses and apartment houses have been conducted numerous times, the researches of energy consumption characteristics on the existing detached houses are lack of studies. Thus in this study, the actual condition of energy consumption characteristics on the existing detached houses in Daegu city was examined, and then energy consumption unit and green house gas emission unit was compiled to present a fundamental data for an effective way of reducing energy consumption and greenhouse gas emission in the buildings. The results showed that the energy consumption for heating in the existing detached house was greater than other energy consumption and the heating energy sources were city gas and fuel oil. As the fuel oil consumption got larger, the energy consumption unit and greenhouse gas emission unit became bigger. Based on these results, it will be able to develop a plan for reducing energy and greenhouse gas emission in the existing detached houses in the future.

A Study on the Improvement of the Green Building Certification Criteria for Detached Houses - Focusing on Comparisons of LEED for Homes - (소형주택의 친환경건축물 인증기준 개선방향에 관한 연구 -LEED for Homes와의 비교를 중심으로-)

  • Kim, Hyun-Ah;Oh, Joon-Gul
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.49-54
    • /
    • 2012
  • The purpose of this study is to generate implications for the Green Building Certification System(GBCS) for detached houses, by comparing LEED for homes. Detached houses were added to the GBCS and took an effect this year. They are evaluated by the GBCS under special conditions, because they are designed by small architectural offices with limited budget. In this respect, this paper points out the problems of the GBCS for these detached houses and highlights some areas to be improved. As the first step, the definition of sustainable building and the design method of green building were investigated. By doing so, this study acknowledges the potential analysis methods in making valid comparisons with LEED for homes. Secondly, this study makes a comparative analysis of the GBCS for detached houses and the GBCS for apartment houses, LEED for New Construction(NC) and LEED for houses. Lastly, it identifies the problems and suggests better ways to improve the GBCS for detached houses through integrated analysis of the GBCS and LEED.

Alternative Selection Method for Energy Efficiency Improvement of Old Detached House (노후 단독주택의 난방에너지 효율 개선을 위한 대안 선정 방법에 관한 연구)

  • Hwang, Seok-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.45-55
    • /
    • 2019
  • More than 76% of the detached houses in Korea are over 20 years old. These old detached houses have poor energy efficiency. According to the 2017 Housing Census (Statistics Korea), more than 50% of low-income families live in detached houses. Therefore, the improvement of energy efficiency in old detached houses is needed from the viewpoint of energy welfare. The general method of building energy modelling for the verification of energy efficiency is based on the construction year data of "Building Design Criteria for Energy Saving" due to the cost and time involved in collecting the thermal performance data of buildings. There is poor accuracy with the deterioration of long-term aging of building materials. Also, the selection of alternatives for energy performance improvement is based on the items to be applied, not a performance improvement goal. It is difficult to calculate energy performance that reflects variations in various parameters with dynamic energy simulations. In this study, the influence of long-term aging is used to accurately predict the energy performance of old detached houses. The building energy modelling method is called ENERGY#, which is a static analysis method based on ISO13790. Energy performance is evaluated by a combination of input variables including building orientation, insulation of walls and roof, thermal performance of windows and window/wall ratio, and infiltration rate. Finally, this study provides a way to determine alternatives that meet energy performance improvement goals.

A Study on the Application of Detached House Smart Home Service for One-person Households (1인 가구를 위한 단독주택의 스마트홈서비스 적용 방안 연구)

  • Jeon, Jin-Bae;An, Se-yun
    • The Journal of the Korea Contents Association
    • /
    • v.20 no.1
    • /
    • pp.180-191
    • /
    • 2020
  • The number of one-person households in the modern society continues to increase, and is expected to increase steadily. In addition, one-person households had the largest number of detached house dwellings, while one-person households had the advantage of free living and free time. However, one-person households have concerns such as loneliness, health problems, safety, risk, and meal solutions, while detached house have problems such as living problems, maintenance, management, safety and risk, and lead to future concerns. This study was conducted in the following ways to improve the concerns of one-person households and the problems of detached house by applying smart home service to detached house. It was integrated through the investigation of concerns and grievances of one-person households and the case of preceding research on the problems of detached house. The latest technology trends of smart home services and the technologies currently developed and marketed were identified through prior research cases and literature surveys. Based on this, the smart home service list and application measures were derived to compensate for the concerns of one-person households and problems of detached house in applying them to smart home services.

The Study on Program for Happy House Sanjeon District Center in Jung-gu, Ulsan City (해피하우스지역센터 프로그램에 관한 연구)

  • Kim, Sun-Joong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.161-166
    • /
    • 2011
  • This research was conducted in order to suggestion management program of Happy house center which facility of detached housings, multi family housing, and semi-detached housing management. This study's purpose is to systematically help create a district customized co-management housing management system among detached housing area by reflecting resident opinion and simultaneously provide basic research. The area of research is Sanjoen district in Ulsan city that compact old detached houses. The research study's results are follows: First, the overall survey results showed that most respondents demanded program of happy house center for housing energy deduction method and support of house insulation cost and heating fuel cost. Second, happy house center try to order of priority or housing maintenance and seek of cost deduction plan. Third, happy house center propose the Maeulmandeulgi(Machizkuri) program or housing management plan for residents' talent contribution.

  • PDF

Evaluation Factors Importance Analysis for Green Building Certification in Detached Houses (소형주택 녹색건축인증 평가항목의 중요도 분석)

  • Shin, Seong-Jun;Yoon, Eun-Lan;Park, Seung-Hwan;Yang, Jin-Kook
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.302-303
    • /
    • 2014
  • The green building certification criteria in detached houses in 2012 and it included in the green building certification subject. However, the green building certification result of the detached houses is slight after revising of the system. Therefore, in this research, we were performed the importance analysis for the green building certification assessment of the detached houses. The results of this study will contribute to the green building certification work.

  • PDF

A Study on the Measurement of Airtightness Performance of Detached Houses in Chung-cheong area (충청지역 단독주택의 기밀성능 실측 연구)

  • Yoon, Jong-Ho;Park, Jae-Wan;Lee, Kwang-Sung;Baek, Nam-Choon;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.65-71
    • /
    • 2008
  • The purpose of this study is to investigate an airtightness of typical Korean detached houses with field measurements. Air leakage testings by means of blower door test in accordance with ASTM E79-8 were measured in 22 detached dwellings in Daejeon and Geumsan. The results showed that detached dwellings have an average airtightness with ACH50/20 (air chang per hour at a pressure difference of 50 Pa between inside outside) of 0.82 $hr^{-1}$ which is a higher range than for typical apartments and leakage class G by normalized leakage area of ASHRAE.

A Comparison of Urban Detached Houses in Seoul's New Housing Quarters in the Early 1960s (1960년대 초 서울 신흥 주거지의 단독주택 세 유형 비교)

  • Jun, Nam-Il
    • Journal of the Korean housing association
    • /
    • v.25 no.5
    • /
    • pp.103-112
    • /
    • 2014
  • This study explores the typology of the urban detached houses in the new housing quarters that were created in the process of Seoul's urbanization in the aftermath of the Korean War. It analyzes and compares the urban tissue and space allocation set when the new urban residential areas were organized according to different methods of production. Based on the comparative analysis of housing built in the same time of 1960s, this study aims to deduce why a specific urban detached housing type was selected as an influential housing prototype and how this spread in later generations. Case study sites selected for this study include: the new Urban Hanok towns of Yongdu-dong, filled with mass Urban Hanoks built by housing developers; the single-family detached housing district of Myunmok-dong, filled with individual dwellings built by private builders; and the housing complex of detached houses in Suyu-dong, developed by government-sponsorship during the early 1960s. Each case examines the following: first, the difference in housing typology allocation according to urban tissue; second, the difference in spatial composition and arrangement within plots. As a result, it was found that differences in typology occur depending on which of the social, cultural, economic and technical factors was preferentially considered in forming urban tissue and allocating buildings in each residential area.

A Study on the Physical Environment Characteristics of the Detached Housing Area in the Housing Site Development District (택지개발지구내 단독주택지의 물리적 환경특성에 관한 연구)

  • 박몽섭;하재명
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.43-51
    • /
    • 2004
  • The purpose of this study is to examine the physical characteristics of the detached housing area in the housing site development district. The process of this study is to investigate the characteristics of the physical structure and the building use, then to analyze the relationship of physical structure and the building use in the aspect of the morphological characteristics. The case study focuses on the Chil-kok2, An-Siml in Taegu. The streets pattern is composited gird and loop type mixed. The block is composited by 2 lots in general. But the obscurity of organization and character of the streets, the size and shape of lots which is not fit to the building use. A whole residential characters appears high residential density ratio. so residential environment became worse. The improving level of residential environment and efficiency of land use in the detached housing area of the housing site development district, firstly the propriety of the physical structure must be considered about detached house characters, and the housing uses which fit to the physical structure are needed, and also for the concrete realization of this, the designation of district, the zoning of residential area, the guideline of the district design, and establishment of comprehensive master planning in detached housing area are needed in aspect of the housing policy. As the result of this study, it suggests several design guideline to improve housing site development.

Effects on the Wave Heights in a Port Caused by the Phase Differences of the Left and Right Diffracted Waves Passing through a Detached Breakwater (이안제를 지나는 좌·우측 회절 파랑의 위상차가 항내 파고에 미치는 영향)

  • Kim, Tak Kyeom;Kwon, Kyong Hwan;Ryu, Ha Sang;Kim, Gyung Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.6
    • /
    • pp.397-407
    • /
    • 2016
  • The traveling waves of the left and right of the detached breakwater are bent behind the detached breakwater by diffraction, causing phase interference, superimposed and propagated. If the direction of the waves becomes same and they head to the entrance of a port due to the geographical conditions, superimposed wave energy could influence inside of a port. In this study, we investigated the influence of the phase difference of the left and right diffraction waves generated according to the length of the detached breakwater on the wave heights in a port through numerical experiments when the detached breakwater at a port entrance is installed. From this result, it was confirmed that the wave heights in a port is increased or decreased by the influence of superimposed caused by the phase difference of the left and right diffraction waves due to the length of the detached breakwater.