Low Cost Design Study of Brushless DC Motor for Electric Water Pump Application

  • Jung, Tae-Uk
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.942-949
    • /
    • 2014
  • We studied about the rotor design change using a Ferrite ring magnet to reduce material cost in the condition of the same stator core design. However, this design direction has many weak points such as the decrease of BEMF, the low maximum output, the irreversible demagnetization characteristics of a permanent magnet and so on. In order to mitigate such disadvantages, an optimization design of the BLDC motor has been developed by changing each design parameter and by improving the electromagnetic structure. In the proposed water pump SPM BLDC motor using Ferrite magnet, the outer and inner diameter of stator is fixed to the value of the conventional IPM BLDC motor using Nd-Fe-B magnet. The design specification requirements should be satisfied with the same output power and efficiency characteristics in the same dimension. As a result of this study, the design comparison results considering driving performances and material cost are represented. Through the actual experiment with the prototype of the designed motor, the simulations results are verified.

톳 추출액을 이용한 친환경 항균성 모발 염색 (Ecofriendly Antimicrobial Hair Coloration Using Sargassum fusiforme Extract)

  • 박성진;김강인;고지민;김아현;장진호
    • 한국염색가공학회지
    • /
    • 제32권1호
    • /
    • pp.38-43
    • /
    • 2020
  • To overcome the harmful effects caused by conventional oxidative hair dyes, natural colorants becomes more popular in the hair dyeing. By extracting Sagassum fusiforme powders with aqueous alkaline solution as a solvent at 130℃ for 60 minutes, a fucoxanthin concentration of up to 216㎍/ml can be obtained. UV/Vis analysis was used to prove the presence of fucoxanthin in the extract powder. A K/S value of 23.8 can be obtained when wool fabrics were dyed with the extract at 120℃ for 60 minutes under pH 2. The color fastness properties of the dyed wool fabrics were very good as indicated by rating 4 for laundering(color change), rating 3 or higher for rubbing, and rating 5 for light irradiation. The dyed wool fabric was found to have antimicrobial activity against Staphylococcus aureus. The antioxidant and antimicrobial activity of the Sagassum fusiforme extract can be an effective functional hair colorant. Hair dyeing with the extract formulation at 45℃ for 40 minutes under pH 5 accomplished a K/S value of 8.9. The color fastness of the dyed hair showed rating 3 against light irradiation, which increased to rating 5 with after-mordanting of tannin acid.

Radiation Exposure Reduction in APR1400

  • Bae, C.J.;Hwang, H.R.;Matteson, D.M.
    • Journal of Radiation Protection and Research
    • /
    • 제28권2호
    • /
    • pp.127-135
    • /
    • 2003
  • The primary contributors to the total occupational radiation exposure in operating nuclear power plants are operation and maintenance activities doting refueling outages. The Advanced Power Reactor 1400 (APR1400) includes a number of design improvements and plans to utilize advanced maintenance methods and robotics to minimize the annual collective dose. The major radiation exposure reduction features implemented in APR1400 are a permanent refueling pool seal, quick opening transfer tube blind flange, improved hydrogen peroxide injection at shutdown, improved permanent steam generator work platforms, and more effective temporary shielding. The estimated average annual occupational radiation exposure for APR1400 based on the reference plant experience and an engineering judgment is determined to be in the order of 0.4 man-Sv, which is well within the design goal of 1 man-Sv. The basis of this average annual occupational radiation exposure estimation is an eighteen (18) month fuel cycle with maintenance performed to steam generators and reactor coolant pumps during refueling outage. The outage duration is assumed to be 28 days. The outage work is to be performed on a 24 hour per day basis, seven (7) days a week with overlapping twelve (12) hour work shifts. The occupational radiation exposure for APR1400 is also determined by an alternate method which consists of estimating radiation exposures expected for the major activities during the refueling outage. The major outage activities that cause the majority of the total radiation exposure during refueling outage such as fuel handling, reactor coolant pump maintenance, steam generator inspection and maintenance, reactor vessel head area maintenance, decontamination, and ICI & instrumentation maintenance activities are evaluated at a task level. The calculated value using this method is in close agreement with the value of 0.4 man-Sv, that has been determined based on the experience aid engineering judgement. Therefore, with the As Low As Reasonably Achievable (ALARA) advanced design features incorporated in the design, APR1400 design is to meet its design goal with sufficient margin, that is, more than a factor of two (2), if operated on art eighteen (18) month fuel cycle.

건설공사 민원 최소화를 위한 민원분류체계 기반 설계성능향상 (Improvement of Design Performance for the Minimization of Public Grievances Based on a Construction Public Grievance Breakdown Structure)

  • 문성우;조화니
    • 한국건설관리학회논문집
    • /
    • 제19권1호
    • /
    • pp.12-20
    • /
    • 2018
  • 건설사업은 사회적 그리고 경제적으로 파급효과가 크기 때문에 프로젝트 추진과정 중 다수의 민원이 발생된다. 이와 같은 현실에서 건설사업을 성공적으로 완료하기 위해서는 계획 및 설계과정에서 민원요인을 분석하고, 민원을 최소화하기 위해서 노력해야 한다. 본 논문은 건설사업의 민원을 평가하기 위한 민원분류체계를 제시하고, 민원분류체계를 바탕으로 설계기능을 개선하여 민원을 최소화하는 것을 목적으로 한다. 논문목적 달성을 위해 연구과정에서는 1) 건설사업 유형별 특성에 따른 민원요인을 분석하고; 2) 민원요인을 기반으로 민원분류체계를 개발했으며; 3) 민원분류체계를 체크리스트로 사용하여 설계대안 창출을 위한 절차를 제시했다. 사례분석에서는 실제 건설사업 설계를 대상으로 민원사전예방을 위한 설계대안을 창출하여 민원대응수준을 향상시켰다.

Comparison of Rigorous Design Procedure with Approximate Design Procedure for Variable Sampling Plans Indexed by Quality Loss

  • Ishii, Yoma;Arizono, Ikuo;Tomohiro, Ryosuke;Takemoto, Yasuhiko
    • Industrial Engineering and Management Systems
    • /
    • 제15권3호
    • /
    • pp.231-238
    • /
    • 2016
  • Traditional acceptance sampling plans have focused on the proportion of nonconforming items as an attribute criterion for quality. In today's modern quality management under high quality production environments, the reduction of the deviation from a target value in a quality characteristic has become the most important purpose. In consequence, various inspection plans for the purpose of reducing the deviation from the target value in the quality characteristic have been investigated. In this case, a concept of the quality loss evaluated by the deviation from the target value has been accepted as the variable evaluation criterion of quality. Further, some quality measures based on the quality loss have been devised; e.g. the process loss and the process capability index. Then, as one of inspection plans based on the quality loss, the rigorous design procedure for the variable sampling plan having desired operating characteristics (VS-OC plan) indexed by the quality loss has been proposed by Yen and Chang in 2009. By the way, since the estimator of the quality loss obeys the non-central chi-square distribution, the rigorous design procedure for the VS-OC plan indexed by the quality loss is complicated. In particular, the rigorous design procedure for the VS-OC plan requires a large number of the repetitive and complicated numerical calculation about the non-central chi-square distribution. On the other hand, an approximate design procedure for the VS-OC plan has been proposed before the proposal of the above rigorous design procedure. The approximate design procedure for the VS-OC plan has been constructed by combining Patnaik approximation relating the non-central chi-square distribution to the central chi-square distribution and Wilson-Hilferty approximation relating the central chi-square distribution to the standard normal distribution. Then, the approximate design procedure has been devised as a convenient procedure without complicated and repetitive numerical calculations. In this study, through some comparisons between the rigorous and approximate design procedures, the applicability of the approximate design procedure has been confirmed.

Improvement on optimal design of dynamic absorber for enhancing seismic performance of nuclear piping using adaptive Kriging method

  • Kwag, Shinyoung;Eem, Seunghyun;Kwak, Jinsung;Lee, Hwanho;Oh, Jinho;Koo, Gyeong-Hoi
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1712-1725
    • /
    • 2022
  • For improving the seismic performance of the nuclear power plant (NPP) piping system, attempts have been made to apply a dynamic absorber (DA). However, the current piping DA design method is limited because it cannot provide the globally optimum values for the target design seismic loading. Therefore, this study proposes a seismic time history analysis-based DA optimal design method for piping. To this end, the Kriging approach is introduced to reduce the numerical cost required for seismic time history analyses. The appropriate design of the experiment method is used to increase the efficiency in securing response data. A gradient-based method is used to efficiently deal with the multi-dimensional unconstrained optimization problem of the DA optimal design. As a result, the proposed method showed an excellent response reduction effect in several responses compared to other optimal design methods. The proposed method showed that the average response reduction rate was about 9% less at the maximum acceleration, about 5% less at the maximum value of the response spectrum, about 9% less at the maximum relative displacement, and about 4% less at the maximum combined stress compared to existing optimal design methods. Therefore, the proposed method enables an effective optimal DA design method for mitigating seismic response in NPP piping in the future.

Follow-up 활동을 강조한 연속적 설계VE 프로세스 (Consecutive Design VE Process Emphasized on Follow-up Activities)

  • 양진국;문성우
    • 대한토목학회논문집
    • /
    • 제29권2D호
    • /
    • pp.235-244
    • /
    • 2009
  • 최근 건설공사에서 설계VE 업무의 중요도는 더욱 증대되고 있으며, 일상적인 관리활동으로 도입되고 있다. 건설공사에서 설계VE는 기본설계와 실시설계 두 번에 걸쳐 진행된다. 설계VE의 효과를 높이기 위해서는 발주자 및 사용자 요구사항과 설계의 라이프 사이클 측면에서 기본설계와 실시설계 VE 결과를 상호 연계할 필요가 있다. 본 연구에서는 설계VE 업무를 효율적으로 수행하기 위한 연속적 설계VE 프로세스를 제시한다. 제시된 모델에서는 Follow-up(후속조치) 활동을 강조하여 VE 성과 분석 중심의 업무모델을 수립했다. 제시된 모델을 설계VE 실무사례에 적용하여 효율성을 검증했다. 실제 VE 업무에 적용한 결과 첫째, 발주자 및 사용자 요구사항을 체계적 반영할 수 있었으며; 둘째, VE 제안내용의 반영계획 수립을 통한 발주자 의사결정을 지원하고; 셋째, 설계업무 인터페이스를 강화하며; 넷째, 반영결과 추적을 할 수 있었다. 이러한 효과를 고려할 때 본 연구에서 제시한 설계VE 업무모델은 설계의 라이프사이클에서 설계VE 결과를 추적하고 업무분석을 체계화하는데 기여할 것으로 기대된다.

Tests and finite element analysis on the local buckling of 420 MPa steel equal angle columns under axial compression

  • Shi, G.;Liu, Z.;Ban, H.Y.;Zhang, Y.;Shi, Y.J.;Wang, Y.Q.
    • Steel and Composite Structures
    • /
    • 제12권1호
    • /
    • pp.31-51
    • /
    • 2012
  • Local buckling can be ignored for hot-rolled ordinary strength steel equal angle compression members, because the width-to-thickness ratios of the leg don't exceed the limit value. With the development of steel structures, Q420 high strength steel angles with the nominal yield strength of 420 MPa have begun to be widely used in China. Because of the high strength, the limit value of the width-to-thickness ratio becomes smaller than that of ordinary steel strength, which causes that the width-to-thickness ratios of some hot-rolled steel angle sections exceed the limit value. Consequently, local buckling must be considered for 420 MPa steel equal angles under axial compression. The existing research on the local buckling of high strength steel members under axial compression is briefly summarized, and it shows that there is lack of study on the local buckling of high strength steel equal angles under axial compression. Aiming at the local buckling of high strength steel angles, this paper conducts an axial compression experiment of 420MPa high strength steel equal angles, including 15 stub columns. The test results are compared with the corresponding design methods in ANSI/AISC 360-05 and Eurocode 3. Then a finite element model is developed to analyze the local buckling behavior of high strength steel equal angles under axial compression, and validated by the test results. Following the validation, a finite element parametric study is conducted to study the influences of a range of parameters, and the analysis results are compared with the design strengths by ANSI/AISC 360-05 and Eurocode 3.

멀티에이전트 기반 가치넷 설계 (Multi-agent based value net design)

  • Kim, Taewoon
    • 한국지능정보시스템학회:학술대회논문집
    • /
    • 한국지능정보시스템학회 2002년도 춘계학술대회 논문집
    • /
    • pp.222-229
    • /
    • 2002
  • 기존의 공급망이 디지털화되고 고객과 공급자간의 파트너쉽과 정보흐름에 있어서 고성능의 네트웍을 형성하는 새로운 개념의 네트 퀀을 가치넷 (value net)으로 정의한다. 이러한 가치넷은 고객이 그 중심에 위치하며 연관되는 제조 사이트와 공급자에 이르는 정보의 배분을 원활하게 해 준다. 본 연구의 목적은 복잡한 공급사슬의 흐름과정에서 발생하는 의사결정과정을 자동화하고 효율화하기 위해서 멀티에이전트를 이용한 프레임 을 설계하고 구매업무와 관련된 영역에 대하여 본 시스템을 구현해 보고자 하는 것이다. 에이전트의 지능적 판단을 위해서는 BDI (Belief, Desire, Intension) 모델을 이용하였다. 본 연구의 결과는 B2B 및 e-Business에서 에이전트를 이용한 조달 및 획득과 관련된 업무에 적용이 될 수 있다.무에 적용이 될 수 있다.

  • PDF

간편법을 이용한 액상화 평가 기준에 대한 고찰 (Overview on Standards for Liquefaction Triggering Evaluation using the Simplified Method)

  • 김연준;고길완;;김병민;김동수
    • 한국지진공학회논문집
    • /
    • 제24권5호
    • /
    • pp.197-209
    • /
    • 2020
  • Evidence of liquefaction during the 2017 Pohang earthquake has highlighted the urgent need to evaluate the current seismic design standard for liquefaction in Korea, particularly the liquefaction triggering standard. With the simplified method, which is the most popular method for evaluating liquefaction triggering, the factor of safety for liquefaction triggering is calculated via the cyclic stress ratio (CSR) and the cyclic resistance ratio (CRR). The parameters in the CSR and CRR have undergone changes over time based on new research findings and lessons learned from liquefaction case-histories. Hence, the current design standard for liquefaction triggering evaluation in Korea should also reflect these changes to achieve seismic safety during future earthquakes. In this study, liquefaction susceptibility criteria were discussed initially and this was followed by a review of the current liquefaction triggering codes/guidelines in other countries and Korea. Next, the parameters associated with the CSR such as the maximum ground acceleration, stress reduction factor, magnitude scaling factor, and overburden correction factor were discussed in detail. Then, the evaluation of the CRR using the SPT N-value and CPT qc-value was elaborated along with overburden and clean-sand correction factors. Based on this review of liquefaction triggering evaluation standards, recommendations are made for improving the current seismic design standard related to liquefaction triggering in Korea.