• 제목/요약/키워드: Design load case

검색결과 926건 처리시간 0.029초

막응력과 휨을 고려한 RC 쉘의 설계와 극한거동 (Combined membrane and flexural reinforcement design in RC shells and ultimate behavior)

  • 민창식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표논문집(II)
    • /
    • pp.405-411
    • /
    • 1998
  • An iterative numerical computational algorithm is presented to design a plate of shell element subjected to membrane and flexural forces. Based on equilibrium consideration, equations for capacities of top and bottom reinforcements in two orthogonal directions have been derived. The amount of reinforcement is determined locally, i. e., for each sampling point, from the equilibrium between applied and internal forces. One case of design is performed for a hyperbolic paraboloid saddle shell (originally used by Lin and Scordelis) to check the design strength against a consistent design load, therefore, to verify the adequacy of design practice for reinforced concrete shells. Based on nonlinear analyses performed, the analytically calculated ultimate load exceeded the design ultimate load from 14-43% for an analysis with relatively low to high tension stiffening, ${\gamma}$ =5~20 cases. For these cases, the design method gives a lower bound on the ultimate load with respect to Lower bound theorem. This shows the adequacy of the current practice at least for this saddle shell case studied. To generalize the conclusion many more designs-analyses are performed with different shell configurations.

  • PDF

대구경 해상 강관말뚝의 설계지지력 확인을 위한 여러 가지 재하시험의 적용 (Case Studies of Several Load Tests for Large Diameter Battered Steel Pipe Piles Constructed on the Offshore Area.)

  • 이정학;서덕동;정헌주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.291-298
    • /
    • 2001
  • It is very difficult to accomplish load tests of piles with large diameter constructed on the offshore area, because of requirement for large scaled loading equipment and bad testing conditions. Therefore, so far in many cases pile driving dynamic formulas have applied to quality control, and recently dynamic load test method is widely used for confirming bearing capacities of such piles. However, in cases of piles with very large diameter about 2,500mm, it is nearly impossible for regular type load test methods of piles such as static and dynamic to apply owing to very large design load. This is case studies of load tests such as modified static and dynamic load tests of piles and point load tests of rock samples for estimating rational allowable bearing capacity of very large diameter piles constructed on the marine area.

  • PDF

Updates of Korean Design Standard (KDS) on the wind load assessment and performance-based wind design

  • Han Sol Lee;Seung Yong Jeong;Thomas H.-K. Kang
    • Wind and Structures
    • /
    • 제37권2호
    • /
    • pp.117-131
    • /
    • 2023
  • Korea Design Standard (KDS) will be updated with two major revisions on the assessment of wind load and performance-based wind design (PBWD). Major changes on the wind load assessment are the wind load factor and basic wind speed. Wind load factor in KDS is reduced from 1.3 to 1, and mean recurrence interval (MRI) for basic wind speed increases from 100 years to 500 years considering the reduction of wind load factor. Additional modification is made including pressure coefficient, torsional moment coefficient and spectrum, and aeroelastic instability. Combined effect of the updates of KDS code on the assessment of wind load is discussed with the case study on the specified sites and building. PBWD is newly added in KDS code to consider the cases with various target performance, vortex-induced vibration, aeroelastic instability, or inelastic behavior. Proposed methods and target performance for PBWD in KDS code are introduced.

양방향말뚝재하시험의 재하용량 기준 설정을 위한 사례분석 연구 (A study on case analysis for loading capacity standard establishment of bi-directional pile load test (BD PLT))

  • 최용규;서정혜;김상일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.377-384
    • /
    • 2008
  • In the bi-directional pile load test (BD PLT) for pile load test of Mega foundation, loading capacity specification were not specified exactly. Therefore there are so many confusions and variations of maximum 2 times in loading capacity are come out. In this study, specifications of bi-directional pile load test (BD PLT) were considered. Based on cases of the bi-directional pile load test performed in domestic areas, maximum equivalent test load, test load increasing ratio and sufficiency ratio of design load were analyzed. It can be known that the loading capacity specification of bi-directional pile load test must be defined as 1-directional test load that is established as more than 2 times of design load.

  • PDF

풍력터빈 출력예측 및 극한하중평가에 관한 연구 (A Study on the Ultimate Load Assessment and the Performance Prediction of a Wind Turbine)

  • 김범석;음학진;김만응
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.326-333
    • /
    • 2009
  • Design life-time of a wind turbine is required to be at least 20 years. In the meantime, the wind turbine will experience a lot of load cases such as extreme loads and fatigue loads which will include several typhoons per year and extreme gusts with 50 years recurrence period as well as endless turbulence flow. Therefore, IEC61400-1 specifies design load cases to be considered in the wind turbine design and requires the wind turbine to withstand the load cases in various operational situations. This paper investigates the ultimate loads which the wind turbine will experience for 20 years and their characteristics based on the IEC61400-1 using an aero-elastic software, GH-Bladed. And the performance characteristics of a wind turbine such as electrical power generation and annual energy yield are also investigated.

수평축 풍력터빈 출력예측 및 극한하중평가 (Ultimate Load Assessment and Performance Prediction of a Horizontal Axis Wind Turbine)

  • 김범석;김만응;음학진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2880-2885
    • /
    • 2008
  • Design lifttime of a wind turbine is required to be at least 20 years. In the meantime, the wind turbine will experience a lot of load cases such as extreme loads and fatigue loads which will include several typhoons per year and extreme gusts with 50 years recurrence period as well as endless turbulence flow. Therefore, IEC61400-1 specifies design load cases to be considered in the wind turbine design and requires the wind turbine to withstand the load cases in various operational situations. This paper investigates the ultimate loads which the wind turbine will experience for 20 years and their characteristics based on the IEC61400-1 using an aero-elastic software, GH-Blade. And the performance characteristics of a wind turbine such as electrical power generation and annual energy yield are also investigated.

  • PDF

집중하중을 받는 Grillage의 소성 붕괴하중 산정 및 일반식 도출 (Formulation of General Equations for Plastic Collapse Loads of Grillages under a Lateral Point Load)

  • 홍기섭;김기성
    • 대한조선학회논문집
    • /
    • 제41권6호
    • /
    • pp.91-101
    • /
    • 2004
  • For the grillage which is common types of structures in marine and land-based structural system, the elastic response and design methods are usually applied. However, plastic analysis and design methods are considered Tn those structures to maintain the structural stability at the limit states. In grillage design, the central intersection point load may be used as a worst loading condition. However, a point load may often move around on the grid system. in such case, the worst load point would not necessarily be at the central point. To investigate the variation of plastic collapse load according to the location of moving load between intersections, the plastic collapse loads are obtained for the three types of grillages with simply-supported ends. From the result of each case, it is confirmed that the worst load point is located between intersections. General formulae related with plastic collapse loads for the three groups of grillages with simply-supported boundaries are derived. Those plastic collapse formulae for the grillages are applied to the design of pontoon deck, and optimum design procedure is illustrated. Consequently, general formulae for the plastic collapse of grillages derived from this study can be easily applied to the plastic analysis and optimum design of similar grillages.

사례분석에 기초한 말뚝시공법 및 재하시험방법에 따른 하중지지특성에 관한 연구 (A Study on the Load Bearing Characteristics Depending on Pile Construction Methods and Pile Load Test Methods Based on Case Analyses)

  • 홍석우;최용규
    • 한국지반공학회논문집
    • /
    • 제28권4호
    • /
    • pp.5-21
    • /
    • 2012
  • 국내의 경우 종래의 말뚝기초의 설계에서는 주로 선단지지력에만 의존하는 설계가 이루어져 왔으나 현장에서 실제 크기 말뚝에 대한 하중전이측정실험이 이루어진 이후 많은 하중전이측정실험 자료들을 통하여 마찰력이 크게 발휘되는 것이 밝혀져 왔다. 본 연구에서는 항타강관말뚝 및 대구경 현장타설말뚝의 재하시험 시 측정된 축하중전이 사례들을 분석하여 재하시험방법에 따른 말뚝기초의 하중지지양상을 구명하였다. 사례 말뚝들의 평균마찰력 분담율을 말뚝의 종류, 재하시험방법, 상대근입길이, 말뚝의 직경, 지반의 종류 등의 함수로 상관관계를 나타내는 것은 곤란하였다. 평균 마찰력 분담율은 50% 이상을 상회하는 것으로 나타나고 있었으므로 사례 말뚝기초는 대체로 마찰지지말뚝으로 거동하는 경우가 많은 것을 볼 수 있었으며 극히 일부 사례말뚝은 혼합지지말뚝으로 거동하였다.

Prediction of total sediment load: A case study of Wadi Arbaat in eastern Sudan

  • Aldrees, Ali;Bakheit, Abubakr Taha;Assilzadeh, Hamid
    • Smart Structures and Systems
    • /
    • 제26권6호
    • /
    • pp.781-796
    • /
    • 2020
  • Prediction of total sediment load is essential in an extensive range of problems such as the design of the dead volume of dams, design of stable channels, sediment transport in the rivers, calculation of bridge piers degradation, prediction of sand and gravel mining effects on river-bed equilibrium, determination of the environmental impacts and dredging necessities. This paper is aimed to investigate and predict the total sediment load of the Wadi Arbaat in Eastern Sudan. The study was estimated the sediment load by separate total sediment load into bedload and Suspended Load (SL), independently. Although the sediment records are not sufficient to construct the discharge-sediment yield relationship and Sediment Rating Curve (SRC), the total sediment loads were predicted based on the discharge and Suspended Sediment Concentration (SSC). The turbidity data NTU in water quality has been used for prediction of the SSC in the estimation of suspended Sediment Yield (SY) transport of Wadi Arbaat. The sediment curves can be used for the estimation of the suspended SYs from the watershed area. The amount of information available for Khor Arbaat case study on sediment is poor data. However, the total sediment load is essential for the optimal control of the sediment transport on Khor Arbaat sediment and the protection of the dams on the upper gate area. The results show that the proposed model is found to be considered adequate to predict the total sediment load.