• Title/Summary/Keyword: Design Test Evaluation

Search Result 2,817, Processing Time 0.039 seconds

Improvement of tip analysis model for drilled shafts in cohesionless soils

  • Chen, Yit-Jin;Wu, Hao-Wei;Marcos, Maria Cecilia M.;Lin, Shiu-Shin
    • Geomechanics and Engineering
    • /
    • v.5 no.5
    • /
    • pp.447-462
    • /
    • 2013
  • An analysis model for predicting the tip bearing capacity of drilled shafts in cohesionless soils is improved in this study. The evaluation is based on large amounts of drilled shaft load test data. Assessment on the analysis model reveals a greater variation in two coefficients, namely, the overburden bearing capacity factor ($N_q$) and the bearing capacity modifier for soil rigidity (${\zeta}_{qr}$). These factors are modified from the back analysis of drilled shaft load test results. Different effective shaft depths and interpreted capacities at various loading stages (i.e., low, middle, and high) are adopted for the back calculation. Results show that the modified bearing capacity coefficients maintain their basic relationship with soil effective friction angle ($\bar{\phi}$), in which the $N_q$ increases and ${\zeta}_{qr}$ decreases as $\bar{\phi}$ increases. The suggested effective shaft depth is limited to 15B (B = shaft diameter) for the evaluation of effective overburden pressure. Specific design recommendations for the tip bearing capacity analysis of drilled shafts in cohesionless soils are given for engineering practice.

Cooling and Heating Performance Evaluation of a GSHP System (지열원 열펌프 시스템의 냉${\cdot}$난방 성능 평가)

  • Sohn Byong Hu;Cho Chung-Sik;Shin Hyun-Jun;An Hyung-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.71-81
    • /
    • 2005
  • The main objective of the present study is to investigate the performance characteristics of a ground-source heat pump(GSHP) system with a 130 m vertical and 62 mm nominal diameter U-tube ground heat exchanger. In order to evaluate the performance analysis, the ground-source heat pump connected to a test room with $90\;m^2$ floor area in the Korea Institute of Construction $Technology(37^{\circ}39'N,\;126^{\circ}48'E)$ was designed and constructed. This ground-source heat pump system mainly consisted of ground heat exchanger, indoor heat pumps and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July 2, 2003 to July 1, 2004. The cooling and heating performance coefficients of the system were determined from the measured data. The average cooling and heating COPs for the system were obtained to be 4.90 and 3.96, respectively. The temperature variations in ground and the ground heat exchanger pipe surface at different depths were also measured.

Development and Evaluation of a Simulation-based Education Course for Nursing Students (간호학생을 위한 시뮬레이션 기반교육과정 개발 및 평가)

  • Yang, Jin-Ju
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.4
    • /
    • pp.548-560
    • /
    • 2008
  • Purpose: This study was conducted to develop a simulation-based education course and to evaluate the results after the application for second year nursing students. Methods: This study was a non-equivalent control pre-post design. Based on the clinical situation scenarios about patients with COPD and MI, a total of two simulation-based learning modules was developed. Pretest and posttest was conducted to evaluate the difference in critical thinking disposition, problem solving, and clinical competence between two groups of 102 students for the experimental group, 2007 and 90 students for the control group, 2006. The experimental group conducted a clinical performance evaluation in the final test, on December 10, 2007. Results: In the experimental group, knowledge related to learning objectives was significantly increased and core intervention was performed almost exactly, but the same result was not observed in domains of analysis of laboratory test, and nursing education for patients. Self-evaluated clinical competence and problem solving level were significantly more improved in the experimental group than control group, but critical thinking disposition level wasn't. Conclusion: In conclusion, a simulation-based education course needs to utilize self-directed learning module like computer-based learning through web contents and MicroSim and video productions for improving nursing students' critical thinking.

  • PDF

The Development and Evaluation of an Incontinence Intervention Program for the Elderly Women at Elderly Welfare Center

  • Kim Jeungim
    • Journal of Korean Academy of Nursing
    • /
    • v.34 no.8
    • /
    • pp.1427-1433
    • /
    • 2004
  • Purpose. The elderly with UI experienced urine leakage for a long time. The prevalence of UI has increased and it makes costly. Particularly, the elderly were reluctant to visit a hospital or a clinic for the reasons of modesty and poverty. To solve this problem, incontinence intervention programs should be provided at the elderly welfare center. The purpose of this research was to develop Incontinence Intervention Program for the Elderly Women (IIPE) and evaluate in its effect. Methods. The study design was quasi-experimental with pre and post-test. The study was performed for ten weeks at one elderly welfare center, Seoul, Korea. The subjects were gathered through an official announcement and informed consent was obtained. IIPE, in this study, was consisted of diagnosis, education, exercise and evaluation. The study variables were PFM exercise adherence, pelvic muscle strength, Continence self-efficacy, geriatric depression and incontinence stress. The effects of the IIPE on PFM exercise adherence, pelvic muscle strength, Continence self-efficacy, geriatric depression and incontinence stress were also evaluated. Results. The mean age of the subjects was 75.2 years. The average attendance was 6.2 times. The IIPE improved PFM exercise adherence, intra-vaginal contraction power and CSE significantly. But it was not significant in incontinence stress and geriatric depression. Other important results were that the two-finger test and urine stream interruption were more useful for elderly women with rigid vaginas in teaching and evaluating. Conclusion. The Findings suggest that IIPE is effective to the community-residing elderly. Further investigation is needed on a long-term basis with control group.

Test and Evaluation for Time Delay Function of Point Detonating Fuze by Underwater Sound Analysis (수중음향 분석을 통한 충격신관 지연기능 시험평가)

  • Na, Taeheum;Jang, Yohan;Jeong, Jihoon;Kim, Kwanju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.217-224
    • /
    • 2017
  • This study proposes an evaluation method for time delay function(TDF) of Point Detonation(PD) fuse using underwater explosion and water entry phenomena. Until now, nothing but the naked eyes of an observer or video images have been used to determine whether the TDF of PD fuze is operated or not. The observer has verified the performance of TDF by analysing the shape of the plume formed by underwater explosion. However, it is very difficult to evaluate the TDF of PD fuse by these conventional methods. In order to overcome this issue, we propose a method using underwater sound signal emitted from the underwater explosion of high explosive charge. The result shows that the measured sound signal is in accord with the physical phenomena of water entry of warhead as well as underwater explosion. Also, from the hypothesis test of bubble period, difference on underwater sound analysis between dud event and delay one is proved.

Pullout Resistance of Steel Strip Reinforcement with Transverse Members using Large-scale Pullout Tests (대형인발시험을 이용한 수동지지저항 부재가 설치된 강재스트립 보강재의 인발저항 평가)

  • Lee, Kwang-Wu;Cho, Sam-Deok;Han, Jung-Geun;Hong, Ki-Kwon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.4
    • /
    • pp.1-8
    • /
    • 2009
  • In this study, the large-scale pullout tests are conducted to evaluate pullout resistance of steel strip reinforcement with transverse members. The test results clearly showed the passive effect by normal stress. This suggests that both friction resistance and passive resistance by normal stress should be taken into account in the evaluation of pullout resistance for design. Therefore, The evaluation results confirmed that the developed steel strip reinforcement with transverse members depend heavily on passive resistance by normal stress.

  • PDF

Capacity evaluation on the slitting device of the spent fuel rod (사용후핵연료봉 slitting 장치 성능 평가)

  • 정재후;윤지섭;김영환;진재현;김동기
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1154-1157
    • /
    • 2003
  • The spent fuel slitting device is an equipment developed for the separation of the pellet and hull from the cutting fuel rod with length of 250 mm, and in order to feed UO$_2$ pellet. We have analyzed on the existing technologies for designing and producing of the slitting device in the first year(2001), based on these results, designed and produced the rod slitting device. It has effectively separated the pellet from the hull, but demanded the supplement separation work because of the mixing with pellet and hull in the vessel, and required the condition for the reducing time of the process. In the second year(2002), we have reduced the work time, performed the test and capacity evaluation with the improving device, based these results, and ensured the data demanded for designing of the spent fuel rod slitting device. We have compared with the DUPIC(Direct use of spent PWR fuel in CAND reactors) process, and developed the device for the purpose of reducing over 40 % in comparition with the DUPIC operation time(5 minutes). Based on these results, it will is effectively applied to available data for designing and producing of the hot test facility.

  • PDF

Development and Evaluation of a Program to Promote Self Management in Patients with Chronic Hepatitis B (만성 B형간염 환자를 위한 자가관리 프로그램의 개발 및 평가)

  • Yang, Jin-Hyang
    • Journal of Korean Academy of Nursing
    • /
    • v.42 no.2
    • /
    • pp.258-268
    • /
    • 2012
  • Purpose: The purpose of this study was to identify the effects of the program to promote self management for patients with chronic hepatitis B. Methods: The research was a quasi-experimental design using a non-equivalent control group pre-post test. The participants were 61 patients, 29 in the experimental group and 32 in the control group. A pretest and 2 posttests were conducted to measure main variables. For the experimental group, the self-management program, consisting of counseling- centered activities in small groups, was given for 6 weeks. Data were analyzed using $X^2$, t-test, and repeated measures ANOVA with PASW statistics program. Results: There were statistically significant increases in knowledge, self-efficacy, active ways of coping, and self-management compliance but not in passive ways of coping in the experimental group compared to the control group over two different times. Conclusion: The results of this study indicate that the self-management program is effective in increasing knowledge, self-efficacy, active ways of coping, and self-management compliance among patients with chronic hepatitis B. Therefore, it can be usefully utilized in the field of nursing for patients with chronic disease as a nursing intervention for people with chronic hepatitis B.

Cooling and Heating Performance Evaluation of a Ground Source Heat Pump (지열원 열펌프의 냉.난방 성능 평가)

  • Sohn, Byong-Hu;Cho, Chung-Sik;Shin, Hyun-Joon;An, Hyung-Jun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2117-2122
    • /
    • 2004
  • The main objective of the present study is to investigate the performance characteristics of a ground source heat pump (GSHP) system with a 130 m vertical 60.5 mm nominal diameter U-bend ground heat exchanger. In order to evaluate the performance analysis, the GSHP system connected to a test room with 90 $m^2$ floor area in the Korea Institute of Construction Technology ($37^{\circ}39'$ N, $126^{\circ}48'$ E) was designed and constructed. This GSHP system mainly consisted of ground heat exchanger, indoor heat pump and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July to January in cooling and heating season of $2003{\sim}2004$. The cooling and heating performance coefficients of the system were determined from the experimental results. The average cooling and heating COPs for the system were obtained to be 4.82 and 3.02, respectively. The temperature variations in ground and the ground heat exchanger surface at different depths were also measured.

  • PDF

Implication and Evaluation of Pain Monitoring Program for Oncology Nurses (암 병동 간호사를 위한 통증모니터링 프로그램 개발 및 효과)

  • Kim, Yeon-Hee;Gong, Sung-Hwa;Choi, Jin-Sun;Jung, Ji-Young;Jun, Myung-Hee
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.2
    • /
    • pp.196-204
    • /
    • 2006
  • Purpose: This study was purposed to identify the effect of pain monitoring program for improving the knowledge, attitude and assessment ability of cancer pain in oncology nurses. Methods: In this study pain monitoring program was developed based on the literature, and constructed it with various teaching method including several group lectures, workshop, focus group and implementation at the clinical practices. In order to test the effect of this program, contrast group, pretest-post test quasi-experimental design was designed. 46 oncology nurses randomly assigned to either control or experimental group. The tool used are 32 item scale for the evaluation of the nurses' knowledge, attitude toward pain modified by Kim(1997), which was originally developed by McCaffery and Ferrel(1995). Results: The pain monitoring program for the oncology nurses was statistically significant for improving the level of the knowledge about and attitude toward pain management, and pain assessment behavior. Conclusion: More sensitive multiple measurement tool for the attitude toward pain management needs to be developed. Nurses need more knowledge and effective attitude toward cancer pain management. Pain monitoring program in this study is effective to improve the quality of pain management.

  • PDF