• Title/Summary/Keyword: Design Test Evaluation

Search Result 2,817, Processing Time 0.04 seconds

The Visual Evaluation According to the Changes in the Shoulder Strap and length of Bikini Swimsuits - Focused on the Undergraduate Students in Busan - (비키니 수영복의 어깨 끈과 길이 변화에 따른 시각적 평가 - 부산지역 대학생을 중심으로 -)

  • Kim, Jeong-Mee
    • Journal of Fashion Business
    • /
    • v.15 no.4
    • /
    • pp.55-66
    • /
    • 2011
  • The purpose of this study is to evaluate the differences of the visual image on variations in the shoulder strap and the length of the bikini swimsuit. Nine samples were examined: 3 variations of the shoulder strap and 3 variations of the pants length. Data have been obtained from 90 fashion design majors and analyzed using Factor Analysis, Anova, Scheffe's Test and the MCA method. The results of this study are as follows: 1) The visual image, according to changes in the shoulder strap and length of the bikini swimsuit, was composed of boldness, matureness and attraction factors. Boldness was the most important factor in the bikini swimsuit. 2) The visual images according to changes in the shoulder strap of the bikini swimsuits appeared the most (1) plain and simple image, (2) decent and neat image, (3) a wanted-not-to-dress and a natural image in the two shoulder straps, (1) unique and complicated image, (2) a lively and sexy image in the one shoulder strap and an unnatural but a wanted-to-dress image in the strapless. 3) The visual images according to changes in length of the bikini swimsuits appeared the most (1) unique and complicated image, (2) a lively and sexy image in high cut, but plain and simple image in low cut. 4) The number of shoulder straps and length do interact with each other in boldness factor: One shoulder strap and high cut of the bikini swimsuit has the most unique and complicated image. However two shoulder straps and regular cut of that has the most plain and simple image. 5) The result of matureness and attraction factors using the MCA, length affects more than the number of shoulder straps in the visual images of the bikini swimsuit.

Evaluation of Structural Performance of Flat Plate-Column Interior Connections with Folded Bend Shear Reinforcement (밴드형 전단보강근으로 보강된 무량판 슬래브 내부접합부의 구조 거동 평가)

  • Lee, Bum-Sik;Park, Seong-Sik;Park, Ji-Young;Bang, Jong-Dae;Jun, Myoung-Hoon;Cho, Gun-Hee
    • Land and Housing Review
    • /
    • v.4 no.4
    • /
    • pp.371-382
    • /
    • 2013
  • This study performs an experimental investigation to evaluate the behavior of RC flat plate interior joints specimens. Three 60 percent scale Flat Plate interior specimens assemblies representing a portion of a Flat Plate Apartment Structural System subjected to simulated seismic loading (unbalanced moments) under constant axial load were tested, including one specimens with ordinary shear reinforcement and two specimens with folded bend type shear reinforcement. Test results are shown that (1) the design code KBC 2009 is accurate estimate the behavior of specimens. (2) Two types shear reinforcement have a similar structural behavior, but construction work of rebar with folded bend type shear reinforcement is easier than that of ordinary shear reinforcement. (3) In moderate seismic region, RC Flat Plate interior joint with folded bend type shear reinforcement is apply to structural design of Flat Plate.

Evaluation of Structural Behavior of Reinforced Concrete Exterior Beam-Column Joints with High-Strength Concrete (고강도 콘크리트를 사용한 철근콘크리트 외부 보-기둥 접합부의 거동 평가)

  • Lee, Bum-Sik;Kim, Kyung-Duk;Kim, Sang-Woo;Kim, Kil-Hee;Lee, Jung-Yoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.72-81
    • /
    • 2014
  • This paper reports the test results of reinforced concrete exterior beam-column joints with high-strength concrete. The main parameters of eight specimens were joint failure modes, the compressive strength of concrete, and the head shapes of steel bars. All specimens were designed according to ACI 352R-02 design recommendations. Two types of failure modes were considered; J-failure and BJ-failure. The longitudinal steel bars were anchored by 90 degree standard hooks or headed reinforcement. Experimental results indicated that the current ACI design recommendation limited by the compressive strength of concrete somewhat underestimated the strength of beam-column joints with high-strength concrete. In the specimens showed joint shear failure, the strength of beam-column joints with headed bars was approximately 10 percent higher than that of joints with 90 degree standard hooks.

A Study on the Development of Torso Pattern for the Schoolgirl of a Tween Generation - Focused on the Elementary School Students of Fifth and Sixth Grades - (트윈세대 여학생을 위한 토르소 원형의 개발에 관한 연구 - 초등학교 5, 6학년을 중심으로 -)

  • Hur Nam-Kyoung;Kim So-Ra
    • The Research Journal of the Costume Culture
    • /
    • v.14 no.3 s.62
    • /
    • pp.387-403
    • /
    • 2006
  • The purpose of this study was to develop a new torso pattern for the schoolgirl of a tween generation who had different somatotype from children and teenagers. The subjects in this study were female elementary school students of fifth or sixth grade. Through a sensory evaluation of four existing torso patterns, the first research torso pattern was developed. Drafting methods of each item, which closed to the optimum value three, were selected. The differences between the values of the selected drafting methods and the optimum three were verified through a Wilcoxon's ranked sum test. The final research torso pattern was developed through adjusting the drafting methods according to the deviation from the optimum value three. The schoolgirl of a tween generation is at the time to show the remarkable breast development compared with a waist circumference, so the bust drafting was defined as B/4+ 1.25cm separately front and back. The drafting of a waist circumference was defined as W/4+1cm separately front and back which taken the ease amounts of the somatotype into consideration of the schoolgirl of a tween generation. A princess line was used instead of a waist dart because their hip circumference was more developed than a waist circumference. The crossed amount of a front hemline was 0.3cm and that of a back hemline was 0.7cm. and the princess line of the position was drawn with a straight line at a right angle of the back waistline. The armhole depth was determined B/4-1cm in consideration of the aesthetic and the trend, although the effective movement of upper arm was required.

  • PDF

A Study on a Reasonable Choice of Simulation Model for Rainfall-Runoff in the Prior Review System on Disaster Effect (사전재해영향성검토 시 합리적인 홍수유출 모의모형 선정에 관한 연구)

  • Lee, Jung-Min;Yun, Jeong-Ran;Kim, Young-Jin;Jin, Kyu-Nam;Han, Hyung-Geun
    • Land and Housing Review
    • /
    • v.1 no.1
    • /
    • pp.75-82
    • /
    • 2010
  • Urban development is a cause of expansion of impervious area. A permanent storage is operated as a method of reducing runoff of watershed. The purpose of study is to propose reasonable choice of simulation model for rainfall-runoff in the prior review system on disaster effect. First, we indicated problem about concentration time choice in the flood simulation. To test the adequacy of a rainfall-runoff simulation model, We analyzed characteristics of rainfall-runoff about urban and natural watersheds. A simulation model was calibrated with the storm of july 7 to July 9 in 2009. From the result, we proposed that SWMM and kinematic wave method as the flood simulation models for urban and natural watersheds. A simulation model and design method of a permanent storage for flood that is proposed in this study will be useful for practical design of flood simulation. The hydrologic analysis method of the study can be used for capacity evaluation of permanent storage plan.

Evaluation of Horizontal Shear Strength of Prestressed Hollow-Core Slabs with Cast-in-Place Topping Concrete (프리스트레스트 중공 슬래브와 현장타설된 토핑콘크리트의 수평전단성능 평가)

  • Im, Ju-Hyeuk;Park, Min-Kook;Lee, Deuck-Hang;Seo, Soo-Yeon;Kim, Kang-Su
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.741-749
    • /
    • 2014
  • Prestressed hollow-core (PHC) slabs are structurally-optimized lightweight precast floor members for long-span concrete structures, which are widely used in construction markets. In Korea, the PHC slabs have been often used with cast-in-place (CIP) topping concrete as a composite slab system. However, the PHC slab members produced by extrusion method use concrete having very low slump, and it is very difficult to make sufficient roughness on the surface as well as to provide shear connectors. In this study, a large number of push-off tests was conducted to evaluate interfacial shear strengths between PHC slabs and CIP topping concrete with the key variable of surface roughness. In addition, the horizontal shear strengths specified in the various design codes were evaluated by comparing to the test results that were collected from literature.

Property Evaluation of the Concrete Replacing 5-13mm Recycled Coarse Aggregates (5~13mm 입도분급 순환 굵은 골재 혼합사용에 따른 콘크리트의 특성평가)

  • Han, Min-Cheol;Song, Young-Wo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • This paper is to investigate experimentally the effect of substitution of recycled coarse aggregate(RCA) under 13mm on the engineering properties of the concrete using gap graded coarse aggregates. Concretes with 0.4 of water to cement ratio(W/C) were fabricated to achieve 30MPa of design strength with coarse aggregate over 13mm in size with the maximum size of 25mm. RCA was substituted for coarse aggregate over 13mm from 10% to 50% and crushed coarse aggregate under 13mm was also substituted for coarse aggregate over 13mm from 20% to 40%, respectively. Test results indicated that the replacement of RCA up to 20% resulted in an increase of fluidity and strength. It also caused a decrease in the drying shrinkage due to dense packing effect by achieving continuous grading of mixed aggregates. For practical application of RCA, when properly substituted, the use of RCA enabled the concrete to reduce water contents and sand to aggregate ratio in mixing design stage of the concrete. And, it can also enhance the compressive strength of the concrete.

Application of MARSSIM for Final Status Survey of the Decommissioning Project (해체사업의 최종현황조사를 위한 MARSSIM 적용)

  • Hong, Sang-Bum;Lee, Ki-Won;Park, Jin-Ho;Chung, Un-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.2
    • /
    • pp.107-111
    • /
    • 2011
  • The release of a site and building from regulatory control is the final stage of the decommissioning process. The MARSSIM (Multi-Agency Radiation Survey and Site Investigation Manual) provides overall framework for conducting data collection for a final status survey to demonstrate compliance with site closure requirements. The KAERI carried out establishing a final status survey by using the guidance provided in the MARSSIM for of a site and building of the Korea Research Reactor. The release criteria for a site and building were set up based on these results of the site specific release levels which were calculated by using RESRAD and RESRAD-Build codes. The survey design for a site and building was classified by using the survey dataset and potential contamination. The number of samples in each survey unit was calculated by through a statistical test using the collected data from a scoping and characterization survey. The results of the final status survey were satisfied the release criteria based on an evaluation of the measured data.

The Stability Evaluation of River Embankment for a Piping Phenomenon (하천제방의 세굴에 대한 안정성 연구)

  • Lee, Song;Park, Hyung-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.3
    • /
    • pp.175-181
    • /
    • 2003
  • In this reseach, a seepage test is carried out for three kinds of soil using a upward seepage equipment. Reliability about the existing method of pipining investigation were verified making an estimate of the critical velocity, the critical hydraulic gradient, and hydraulic conductivity and so on. Also, sensitive analyses were carried out using Plaxis that is FEM Program about design factors of scour. The height of core had a big infulence on the hydraulic gradient of the embankment's lower part in the result of sensitive anaylsis. Also, second only to the height of core, and the slope of embankment, the width of crest had influence on scour. However, the change of hydraulic gradient in the effluent gateway had a little influence on the crest width of core. Using these results of sensitive analysis on designing, hydraulic gradient in the effluence gateway turned out to be reducing by altering design factors that change of sensitiveness is big, in case of the hydraulic gradient bigger than the standard hydraulic gradient.

Parameter Evaluation of High-Power Pulse Transformer for L-Band 30-MW Klystron (L-band 30-MW 클라이스트론용 고출력 펄스트랜스포머의 파라미터 평가)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Kim, S.H.;Yang, H.R.;Moon, S.I.;Kwon, B.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1079-1081
    • /
    • 2007
  • An L-band Linear Accelerator System for E-beam sterilization is under construction for bio-technology application. The klystron-modulator system as an RF microwave source has an important role as major components to offer the system reliability for long time steady-state operations. A PFN line type pulse generator with a peak power of 71.5-MW, $7\;{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7\;{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present measurements and its analysis on the design parameters, and an initial test result as well as a design concept on the high-power pulse transformer.

  • PDF