• Title/Summary/Keyword: Design Standard Code

Search Result 444, Processing Time 0.025 seconds

Design of T-DMB Automatic Emergency Alert Service Standard: Part 2 Service Model, Transport Channel, and Service Signaling (지상파 DMB 자동재난경보방송표준 설계: 제2부 서비스 모델, 전송 채널, 서비스 시그널링)

  • Choi, Seong-Jong;Kwon, Dae-Bok;Kim, Jae-Yeon;Oh, Keon-Sik;Chang, Tae-Uk;Hahm, Young-Kwon
    • Journal of Broadcast Engineering
    • /
    • v.12 no.6
    • /
    • pp.630-640
    • /
    • 2007
  • This paper presents the design of service model, transport channel, and service signaling for the Terrestrial DMB Automatic Emergency Alert Service (AEAS) Standard. The paper begins with the analysis of technical backgrounds related to the design topics. Next, the raper presents the design of service model for the AEAS. Since, unlike the regular T-DMB services, the AEAS is event-driven and common to all services, some problems have been identified to design a service model conforming to the T-DMB standard. So, the paper proposes a new concept, called the common service, and the AEAS is modeled using the common service. Next, in order to decide the transport channel for the alert information, the paper proposes to divide the alert information into the message which contains code/text-based essential information, and the supplemental multimedia information. Then, the paper tries to find the most efficient transport channels. Emergency Warning Service (EWS) which uses FIG 5/2 is selected for the delivery of the message. The paper proposes no constraints on delivery of supplemental information except that it shall use the MSC. Finally, it proposes the service signaling for the common service and transport channel. Due to the problems of conventional signaling using the MCI, it proposes a new signaling method. The paper will contribute as a guideline to the development for emergency alert service standards fur other broadcasting media.

Mechanical Properties and Predictions of Strength of Concrete Containing Recycled Coarse Aggregates (순환굵은골재를 포함하는 콘크리트의 역학적 특성 및 강도 예측)

  • Yang, In-Hwan;Kim, Kyoung-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.2
    • /
    • pp.49-59
    • /
    • 2016
  • According to KS and Standard Specifications for Concrete, the compressive strength of concrete containing recycled aggregate is limited to 27 MPa and thereafter there are little research on concrete containing recycled aggregate of its compressive strength of greater than 27 MPa. Therefore, to expand the applicability of concrete recycled coarse aggregate(RCA), this paper concerns the mechanical properties of concrete containing RCA with compressive strength ranging from 30 to 60 MPa. The experimental parameters were water-cement ratio and replacement ratio of RCA. Water-cement ratio(w/c) was 0.36, 0.46 and 0.53, and replacement ratio of RCA was 30, 50, 70 and 100%. The experimental results were discussed about compressive strength, elastic modulus, split tensile strength and modulus of rupture. Test results of elastic modulus were compared to the design code predictions. Experimental elastic modulus for concrete with w/c=0.53 decreased by greater than 10% compared with that for concrete with w/c=0.36. The design code predictions for elastic modulus overestimated the experimental results. Whereas, the design code predictions for modulus of rupture underestimated the measured values.

Analysis of Natural Ventilation Rates of Venlo-type Greenhouse Built on Reclaimed Lands using CFD (전산유체역학을 통한 간척지 내 벤로형 온실의 자연환기량 분석)

  • Lee, Sang-Yeon;Lee, In-Bok;Kwon, Kyeong-Seok;Ha, Tae-Hwan;Yeo, Uk-Hyeon;Park, Se-Jun;Kim, Rack-Woo;Jo, Ye-Seul;Lee, Seung-No
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.57 no.6
    • /
    • pp.21-33
    • /
    • 2015
  • Recently, the Korean government announced a new development plan for a large-scale greenhouse complex in reclaimed lands. Wind environments of reclaimed land are entirely different from those of inland. Many standard books for ventilation design didn't include qualitative standard for natural ventilation. In this study, natural ventilation rates were analyzed to suggest standard for ventilation design of venlo type greenhouse built on reclaimed land. CFD (Computational Fluid Dynamics) simulation models were designed according to the number of spans, wind conditions and vent openings. The wind profile at a reclaimed land was designed using ESDU (Engineering Sciences Data Unit) code. Using the designed CFD simulation model, ventilation rates were computed using mass flow rate and tracer gas decay method. Additionally computed natural ventilation rates were evaluated by comparing with ventilation requirements. As a result of this study, ventilation rates were decreased with increasing of the number of spans. Ventilation rates were linearly increased with increasing of wind speed. When the wind speed was $1.0\;m{\cdot}s^{-1}$, only side vent was open and wind direction was $45^{\circ}$, homogeneity of ventilation rate at 0~1 m height is the worst. Finally, chart for computing natural ventilation rate was suggested. The chart was expected to be used for establishing standard of ventilation design.

A Study on The Reengineering Tool From conventional System into Design Pattern (기존 시스템에서 설계 패턴으로의 재공학 툴에 관한 연구)

  • Kim, Haeng-Kon;Cha, Jung-Eun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.9
    • /
    • pp.2334-2344
    • /
    • 1998
  • Appliciltion systems focusing class units, as component abstraction based on source code, has insufficient benefit of independency and reuse of elements. Only few effects are acquired, because it is only inclined implementation. We need design pattern to represent not only the problem abstraction but also information and relationship between system elements for generic solutions of specific domain Also, it is essential to software reverse engineering to catch the correct system through examming the cxisting system and utilizing the acquired knowledges as reusable resource. Namely, software reverse engineering for extracting the design pattern is very important because it improves the understand ability for system analysis and design through extracting the design structure of object-oriented system, and provides rich and high leIel reusabilitv through grasping the standard idioms and relationships between components. In this paper, we defined the extraction algorithm for design patterns with standardized, packaged and quantitative measlIIul thruugh applying reyerse engineering into existing ubject Olicnted system. And we designed the reengineering toul including reverse engineering for autumatic extractiun of design patterns ami reuse fur retrieval. editing and rebuilding oi design patterns. Also we applied the algorithms into Java applications.

  • PDF

Finite Element Analysis of an Agricultural Tractor Cabin based on the OECD Standard(code 4) (OECD규정(제4항)에 기초한 농업용 트랙터 캐빈의 유한요소 해석)

  • 하창욱;김현진;구남서;권영두
    • Journal of Biosystems Engineering
    • /
    • v.28 no.4
    • /
    • pp.305-314
    • /
    • 2003
  • The ROPS of an agricultural tractor is designed to protect its driver when the tractor overturns. Although the current OECD tests to determine whether the ROPS meets the requirements of the OECD regulation are desirable, they need long time to test. We experimental time and effort by using CAE. We conducted a finite element analysis for the ROPS design of a Dae-Dong tractor cabin in an attempt to reduce the design and manufacturing time. This study shows the interpretative skill using MARC(v.2000) for designing ROPS and difference between the results of testing and FEA. Design process is generally divided into two phases: a concept and a detail design. The concept design uses simple analysis to predict structural behavior, whereas the detail design involves a finite element analysis performed by the results of the concept design. This study focused on the detail design and used Patran(v.2000r2) and MARC(v.2000) of the MSC software corporation. The model consisted of 4812 elements and 4582 nodes. Four tests. specified in the OECD standards, were performed: (1) longitudinal loading test (2) rear crushing test (3) side loading test (4), and front crushing test. Independent analyses were also performed for each test, along with a sequential analysis. When compared, the results of the independent and sequential analyses were found to be similar to the test results.

Simulated tropical cyclonic winds for low cycle fatigue loading of steel roofing

  • Henderson, David J.;Ginger, John D.;Morrison, Murray J.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.383-400
    • /
    • 2009
  • Low rise building roofs can be subjected to large fluctuating pressures during a tropical cyclone resulting in fatigue failure of cladding. Following the damage to housing in Tropical Cyclone Tracy in Darwin, Australia, the Darwin Area Building Manual (DABM) cyclic loading test criteria, that loaded the cladding for 10000 cycles oscillating from zero to a permissible stress design pressure, and the Experimental Building Station TR440 test of 10200 load cycles which increased in steps to the permissible stress design pressure, were developed for assessing building elements susceptible to low cycle fatigue failure. Recently the 'Low-High-Low' (L-H-L) cyclic test for metal roofing was introduced into the Building Code of Australia (2007). Following advances in wind tunnel data acquisition and full-scale wind loading simulators, this paper presents a comparison of wind-induced cladding damage, from a "design" cyclone proposed by Jancauskas, et al. (1994), with current test criteria developed by Mahendran (1995). Wind tunnel data were used to generate the external and net pressure time histories on the roof of a low-rise building during the passage of the "design" cyclone. The peak pressures generated at the windward roof corner for a tributary area representative of a cladding fastener are underestimated by the Australian/New Zealand Wind Actions Standard. The "design" cyclone, with increasing and decreasing wind speeds combined with changes in wind direction, generated increasing then decreasing pressures in a manner similar to that specified in the L-H-L test. However, the L-H-L test underestimated the magnitude and number of large load cycles, but overestimated the number of cycles in the mid ranges. Cladding elements subjected to the L-H-L test showed greater fatigue damage than when experiencing a five hour "design" cyclone containing higher peak pressures. It is evident that the increased fatigue damage was due to the L-H-L test having a large number of load cycles cycling from zero load (R=0) in contrast to that produced during the cyclone.

Optimal Life Cycle Cost Design of a Bridge (교량의 생애주기비용 최적설계)

  • Park, Jang-Ho;Shin, Yung-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.115-122
    • /
    • 2010
  • The importance of the life cycle cost (LCC) analysis for bridges has been recognized over the last decade. However, it is difficult to predict LCC precisely since the costs occurring throughout the service life of the bridge depend on various parameters such as design, construction, maintenance, and environmental conditions. This paper presents a methodology for the optimal life cycle cost design of a bridge. Total LCC for the service life is calculated as the sum of initial cost, damage cost, maintenance cost, repair and rehabilitation cost, user cost, and disposal cost. The optimization method is applied to design of a bridge structure with minimal cost, in which the objective function is set to LCC and constraints are formulated on the basis of Korean Bridge Design Code. Initial cost is calculated based on standard costs of the Korea Construction Price Index and damage cost on damage probabilities to consider the uncertainty of load and resistance. Repair and rehabilitation cost is determined using load carrying capacity curves and user cost includes traffic operation costs and time delay costs. The optimal life cycle cost design of a bridge is performed and the effects of parameters are investigated.

A simple method for estimating the major nuclide fractional fission rates within light water and advanced gas cooled reactors

  • Mills, R.W.;Slingsby, B.M.;Coleman, J.;Collins, R.;Holt, G.;Metelko, C.;Schnellbach, Y.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.9
    • /
    • pp.2130-2137
    • /
    • 2020
  • The standard method for calculating anti-neutrino emissions from a reactor involves knowing the fractional fission rates for the most important fissioning nuclides in the reactor. To calculate these rates requires detailed reactor physics calculations based upon the reactor design, fuel design, burnup dependent fuel composition, location of specific fuel assemblies in the core and detailed operational data from the reactor. This has only been published for a few reactors during specific time periods, whereas to be of practical use for anti-neutrino reactor monitoring it is necessary to be able to predict these on the publicly available information from any reactor, especially if using these data to subtract the anti-neutrino signal from other reactors to identify an undeclared reactor and monitor its operation. This paper proposes a method to estimate the fission fractions for a specific reactor based upon publicly available information and provides a database based upon a series of spent fuel inventory calculations using the FISPIN10 code and its associated data libraries.

An Experimental Study of Reinforced Concrete Beams with Closely-Spaced Headed Bars

  • Lam, Kah Mun;Kim, Woo-Suk;Van Zandt, Michael;Kang, Thomas H.K.
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.2
    • /
    • pp.77-85
    • /
    • 2011
  • The use of headed bars as opposed to standard 90- or 180-degree hooked bars in beam ends, beam-column joints or other steel congested areas for anchorage and bond has become more favorable due to the fact that steel congestion is often created by large bend diameters or crossties. This research mainly focuses on evaluating the code provisions regarding the use of headed bars. Nine simply supported rectangular concrete beams with headed longitudinal reinforcement were tested under a four-point monotonic loading system. The design clear spacing, which varies from 1.5 to 4.25 times the bar diameter, was the only parameter for the experimental investigation. The test results showed that the closely-spaced headed bars were capable of developing to full yield strength without any severe brittle concrete breakout cone or pullout failure. Bond along the bar was not sufficient due to the early loss of concrete integrity. However, the headed bars were effective for anchorage with no excessive moment capacity reduction. This implies that the clear spacing of about 2 times the bar diameter for headed bars may be reasonable to ensure the development of specified yield strength of headed bars and corresponding member design strength.

Stability analysis of a tunnel excavated in weak rocks and the optimal design for the support pattern (연약지반내 굴착터널의 안정성 평가 및 최적보강설계에 관한 연구)

  • 최성웅;신희순
    • Tunnel and Underground Space
    • /
    • v.7 no.3
    • /
    • pp.191-201
    • /
    • 1997
  • Geological and geotechnical surveys, in general, should precede the excavation to ensure the safety of the tunnel and should be followed up according to the various geological condition during the excavation. However actually the standard support patterns which were decided during the design step used be insisted for the whole excavation steps in spite of the various geological conditions. OO tunnel was excavated with NATM and a support pattern type-V in weak rocks. When the tunnel was excavated up to 25m long, the severe displacement was generated in the portal area and the shotcrete was damaged to make the cracks and the tunnel face was totally collapsed. It might happen owing to the one-day heavy rain, but the exact reason for that accident should be found out and the new optimal support patternt needed. Consequently three dimensional numerical analysis was applied for the evaluation of the cause of the tunnel collapse instead of two dimensional analysis, because three dimensional analysis can show better the real field phenomenon than two dimensional analysis in which the load distribution methods are adopted for the tunnel excavation. We could simulate the actual situations with three dimensional finite difference code and propose the new optimal support patterns.

  • PDF