• 제목/요약/키워드: Dept. of dental technology

검색결과 523건 처리시간 0.022초

전해수의 특성에 관한 연구 (The Study of Characteristics of Electrolytic Water)

  • 이찬우;배기서
    • 한국염색가공학회지
    • /
    • 제18권6호
    • /
    • pp.43-48
    • /
    • 2006
  • Electrolytic water(EW), studied in recent decades in the Japan, Russia and United State of America, have shown promise as a method of disinfection whereby low levels of free chlorine, sodium hypochlorite, or hypochlorous acid may be produced in situ in Nacl-containing solution. These methods have shown promise in destruction of microorganisms in medical, dental environment, and in the agriculture and food industry. A recently EW treatment system was evaluated for reducing scouring agent and other surfactants in the washing and scouring process of textile industry Unfortunately, there is, to my knowledge, no serious studies of the properties of EW for textile industry In order to study the characteristics of EW and confirm the possibility of applications in textile industry processes, the pH, surface activity, penetration force, surface tension, and contact angle of EW was measured under various conditions. In general terms, What all this shows is that there is fundamental difference between the properties of EW and that of distilled water.

The comparative study on changes in turnover intention according to the level of Burn out and the convergence mediating factors in fire officer

  • Ji, Dong-Ha;Choi, Mi-Suk
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권5호
    • /
    • pp.111-117
    • /
    • 2016
  • The purpose of this study is to analyze the changes in turnover intention according to the level of Burn out and the mediating effect in fire officer. Higher levels of emotional labor and turnover intention resulted in higher levels of burn out(p<0.05). We used the logistic regression analysis to compare change of turnover intention according to the level of burn out. In logistic regression analysis, largest mediating factor were working days per week, the number of moving case per a day, physical condition, emotional labor and the odds(Likely to with high turnover intention) was down by 38.9% after adjustment for mediating factors. The results of this study indicate that emotional labor was negatively impact on burn out in fire officer. To reduce the burn out and the turnover intention, it is necessary to do more efforts to improve work environment (working days per week, the number of moving case per a day and emotional labor) and management personal factor(physical condition) for the fire office should be made to reduce such negative effects.

고주파유도용접된 열교환기용 BAS121합금튜브의 기계적 특성에 미치는 인발조건의 영향 (Effects of Drawing Parameters on Mechanical Properties of BAS121 Alloy Tubes for Heat-exchangers by High Frequency Induction Welding)

  • 한상우;김병일;이현우;전우용;국진선
    • 한국재료학회지
    • /
    • 제14권12호
    • /
    • pp.851-856
    • /
    • 2004
  • The aim of this study is to investigate the optimum drawing parameter for BAS121 welded tubes. The BAS121 aluminium alloy tubes with 25 mm in external diameter and 1.3 mm in thickness for heat-exchangers were manufactured by high frequency induction welding with the V shaped convergence angle $6.5^{\circ}$ and power input 55 kW. With increasing the reduction of area ($13,\;21\%$) by drawing, tensile strength was increased and elongation was decreased. With increasing the reduction of area by drawing, hardness in weld metal increased rapidly, while that of base metal increased slowly. In the specimen with the outer diameter smaller than 22 mm, hardness of weld metal was higher than that of base metal. The optimum drawing parameter of area reduction in BAS121 alloys was estimated about $13\%$ because of the work hardening of welds.

Corrosion Behavior of Hard Coated Ti-Zr-N Film on the Tool Steels

  • Eun, Sang-Won;Choe, Han-Cheol
    • Corrosion Science and Technology
    • /
    • 제9권6호
    • /
    • pp.289-293
    • /
    • 2010
  • To investigate the corrosion behavior of tools steel surface in various coating film, the surface of hard coated Ti-Zr-N film on the tool steel by using magnetron-sputtering methods was researched using various experimental methods. STD 61 steels were manufactured by using vacuum furnace and solutionized for 1hr at $1050^{\circ}C$. Steel surface was coated with Ti-Zr-N film at $150^{\circ}C$ and 100W for 1h by using DC-sputtering equipment. Surface characteristics of Ti-Zr-N film coated specimens were investigated by OM, XRD, FE-SEM and nano-scratch tester. And corrosion behaviors of the coated specimen were investigated by polarization test and electrochemical impedance spectroscopy(EG&G Co, PARSTAT 2273. USA). It was found that Ti-Zr-N film coated sample had a thick coated layer and showed a good wear resistance and corrosion resistance of surface compared with ZrN and TiN coated sample. The corrosion resistance and mechanical property of Ti-Zr-N film coated STD 61 alloy increased as sputtering time increased.

플라즈마 전해 산화처리된 Ti-6Al-4V합금의 표면특성에 미치는 울라스토나이트 코팅효과 (Effects of Wollastonite Coating on Surface Characteristics of Plasma Electrolytic Oxidized Ti-6Al-4V Alloy)

  • 고재은;이종국;최한철
    • Corrosion Science and Technology
    • /
    • 제22권4호
    • /
    • pp.257-264
    • /
    • 2023
  • Ti-6Al-4V alloys are mainly used as dental materials due to their excellent biocompatibility, corrosion resistance, and chemical stability. However, they have a low bioactivity with bioinertness in the body. Therefore, they could not directly bond with human bone. To improve their applications, their bone bonding ability and bone formation capacity should be improved. Thus, the objective of this study was to improve the bioinert surface of titanium alloy substrate to show bioactive characteristics by performing surface modification using wollastonite powder. Commercial bioactive wollastonite powder was successfully deposited onto Ti-6Al-4V alloy using a room temperature spray process. It was found that wollastonite-coated layer showed homogeneous microstructure and uniform thickness. Corrosion resistance of Ti-6Al-4V alloy was also improved by plasma electrolytic oxidation treatment. Its wettability and bioactivity were also greatly increased by wollastonite coating. Results of this study indicate that both plasma electrolytic oxidation treatment and wollastonite coating by room temperature spray process could be used to improve surface bioactivity of Ti-6Al-4V alloy substrate.

Fe-P-C-B-Al-Mo계 비정질합금의 열적.화학적 성질에 미치는 P 및 Mo의 영향 (The Effect of P and Mo for Thermal and Chemical Properties of Fe-PC-B-Al-Mo Amorphous Alloys)

  • 국진선;전우용
    • 열처리공학회지
    • /
    • 제15권2호
    • /
    • pp.76-81
    • /
    • 2002
  • The melt-spun amorphous $Fe_{77-X}P_{13}C_4B_4Al_2Mo_X$(x=4~10) and $Fe_{82-X}P_XC_4B_4Al_2Mo_8$(x=9~15) alloys were found to exhibit a large supercooled liquid region(${\Delta}T_x$) exceeding 40 K before crystallization. The largest ${\Delta}T_x$ for the glassy alloys containing Mo reaches as large as 65 K for the $Fe_{69}P_{13}C_4B_4Al_2Mo_8$ alloy. The corrosion behavior of the amorphous $Fe_{77-X}P_{13}C_4B_4Al_2Mo_X$(x=4~15) and $Fe_(82-X)P_XC_4B_4Al_2Mo_8$ (x=9~17) alloys were examined by electrochemical measurements in 9M $H_2SO_4$ solution at 303 K. The addition of Mo(or P) for replacing some portion of Fe is effective in improving the corrosion resistance of the investigated Fe-based glassy alloys. They are spontaneously passivated and have a wide passive region with low passive current density.

CHANGES OF ABUTMENT SCREW AFTER REPEATED CLOSING AND OPENING

  • Kim Hee-Jung;Chung Chae-Heon;Oh Sang-Ho;Choi Han-Cheol
    • 대한치과보철학회지
    • /
    • 제42권6호
    • /
    • pp.628-640
    • /
    • 2004
  • Statement of problem. Wear as a result of repeated closing/opening cycles may decrease the friction coefficient of screw head, threads, and other mating components and, consequently, resistance to opening gradually decreases. It may cause screw loosening, which is one of the most common failures in implant prosthesis. Purpose. The purpose of this study is to evaluate the changes on the head and thread surface of the abutment screws after repeated closing and opening through the examination of tested screws in SEM(scanning electron microscope). Materials and methods. Five species of abutments were selected (3i-three, Avana-two) respectively by two pieces. The implant fixtures were perpendicularly mounted in liquid unsaturated polyesther(Epovia, Cray Valley Inc.) with dental surveyor. Each abutment was secured to the implant fixture by each abutment screw with recommended torque value using a digital torque controller. The abutment screws were repeatedly tightened and removed 20 times with a digital controller. FESEM (field emission scanning electron microscope, Netherland, Phillips co., model:XL 30 SFEG) was used to observe changes of each part caused by repeatedly closing/opening expeiment. First, the Photomicrographs of pre-test screws provided by each manufacturer were taken. The changes of each screw were investigated after every fifth closing and opening experiment with FESEM. Scaning electron microscope photomicrographs of each screw were taken four times. Results. As the number of closing and opening was increased, the wear or distortion of hexed or squared slot that contacted with the driver tip was more severely progressed. Wear or distortion of hexed slot was more severe than that of squared slot and it was more remarkable in the titanium screw than in the gold screw. All the tested screws showed that the width in the crest of their screw thread decreased gradually as the test was proceeded. Conclusions. Conclusively, we recommend the clinical use of gold screw, a periodic exchanges of abutment screws and avoiding repeated closing/opening unnecessarily. We also suggest a more careful manipulation of the abutment screw and screw-driver and using of abutment screw with an acute-angled slot design rather than an obtuse-angled one. Finally, it is suggested that the new slot design and the surface treatment for enduring wear or distortion should be devised.

지르코니아 코어의 종류와 도재 두께에 따른 색상의 변화 (The study on the shade color change that depends on the kind of zirconia core and the porcelain thickness)

  • 염미옥;이종혁;신수연;신승철;조자원
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.341-350
    • /
    • 2010
  • Purpose: This study focused on achieving desired shades by combining zirconia core with different thickness porcelain in order to make dental prostheses effectively. Methods: White and colored $LAVA^{TM}$ All Ceramic (3M-ESPE, Seefeld, Germany), and Zirkonzahn (Bruneck, Italy) Trans and prettau were used to have Zirconia. LAVATM Ceram (3M-ESPE, Germany) and ICE (Zirkonzahn, Italy) powder were used to have the porcelain. We made quadrilateral specimen of thickness 0.3mm, 0.5mm, 0.7mm and diameter 10 to use zirconia ceramics system of 2 kinds that color tone reappearance way is different and produced total 120 specimens to 4 experimental groups. We used Spectrophotometer to analyze color tone. Data's value getting by dispersal colorimetry period found L*, a*, b* value using Excel program. We used one-way ANOVA to use SPSS WIN 12.0 program. Results: All L*, a*, b* indexes of zirconia core and porcelain veneer in LAVA group and Zirkonzahn group were different. When you combine the white zirconia core of LAVA group with a porcelain veneer, the thickness of the porcelain must be more than 0.5mm to meet the standard target. When all the colored zirconia cores of LAVA group were combined with porcelain veneers, there was no significant difference from the standard target. When the zirconia cores of Zirkonzahn group are combined with porcelain veneers, the thinner thicknesses were closer to the standard tab than thicker thicknesses; however, there was a significant difference in all combinations, with Delta E* value indicating more than 3. Conclusion: When it comes to colored zirconia, which is the most popular, the thicknesses of both a core and a dentin veneer must be more than 0.3mm to get an appropriate shade. There is more possibility to get desirable shades when the thicknesses of a white core are thinner; however, they would be vulnerable to the environment and lose their color. When combine a zirconia core with a dentin veneer, using Zirkonzahn group needs more considerations in order to meet the standard target.

나노에멀젼 젤로 만든 고기능성치약을 이용한 구강 연조직 창상 및 병소에 대한 치험례 (CASE REPORTS: TREATMENT OF ORAL SOFT TISSUE LESIONS AND WOUNDS WITH HIGH FUNCTIONAL TOOTH PASTE MADE FROM NANOEMULSION GEL)

  • 채창훈;최동주;심혜영;변은선;홍순민;박양호;박준우
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권6호
    • /
    • pp.694-700
    • /
    • 2007
  • It is a gel type high functional toothpaste containing vitamin C, E, propolis extract and the rest of herb with a nanoemulsion state. Vitamin C, E is known as the material with an eminent anti-oxidation effect. Propolis is known as the material with an antimicrobial and anti-inflammatory effect. We have been succeeding in making nanoemulsion of vitamin C, E and propolis through the high pressure homogenizer using stable oil and lecithin and the gel type high functional tooth paste were made from nanoemulsion of vitamin C, E and propolis. We observed the process of wound protecting effect and cure effect for a wound of soft tissue, gingival tissue and mucous membrane showing ulcer and inflammation in oral cavity after applying a gel type high functional toothpaste to patient. As a result, the wound were healed very fast and any side effects were not shown. We confirmed that a gel type high functional toothpaste with nanoemulsion of vitamin C, E and propolis extract has good effect not only for wound healing but also for treatment of ulcer-like lesion in oral cavity. So we report our cases with review of literatures.

전기분해수로 코로나방역용 마스크의 세정에 관한연구 (On a Cleaning of COVID-19 Prevention Masks with Electrolytic Decomposition Water)

  • 전지행;배명진
    • 문화기술의 융합
    • /
    • 제8권1호
    • /
    • pp.591-596
    • /
    • 2022
  • WHO에서 다양한 코로나19 방역지침과 국가별로 조치가 취해지고 있지만, 확진 자는 크게 감소되지 않고 있다. 개인의 비말을 통해 코로나가 유입 및 유출되는 것을 방지하기 위해 언제 어디서나 마스크착용을 의무화하고 있다. 그렇지만 마스크에 들어온 바이러스세균들이 증폭되면서 마스크를 오염시키고, 역겨운 냄새를 유발한다. 본 논문에서는 장시간 사용한 마스크에 유입된 코로나세균을 치과용 가걸 수의 스프레이로 마스크를 살균하는 방법으로 코로나전파를 예방하는 새로운 방법을 제안하였다. 치과용 가걸 수는 보통 수돗물의 전기 분해로 생성되는데, 물에 녹아있는 불안정 상태의 이온 수(HOCl)가 각종바이러스의 세포장벽에 침투하여 그 핵의 작용을 무산시켜 물의 자정작용을 일으킨다. 실험결과 장시간 사용한 마스크를 가걸 수의 스프레이로 세척하였을 때, 세척된 마스크는 10분 후에 건조되었고, 바이러스 비말이나 침 냄새가 거의 사라졌다. 특히 마스크세정에 참여한 피험자들에게 그 착용감을 MOS테스트한 결과 평균 4.4로 우수하게 얻어졌다. 따라서 마스크가 1회 용이었지만, 하루에 2회 이상 제안한 방법으로 스프레이 세척하게 되면, 그 마스크를 1주일 이상 쾌적한 상태로 사용할 수 있게 되었다.