• 제목/요약/키워드: Dept. of dental technology

검색결과 523건 처리시간 0.022초

순수 티타늄 주조체의 주형온도에 따른 미세조직 및 기계적 성질 (Microstructures and Mechanical Properties of Pure Titanium Casting Specimens with Mold Temperatures)

  • 차성수;남상용;송영주
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.307-315
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the change of microstructures and mechanical properties of pure titanium casting specimens as a function of mold temperatures. Methods: The pure titanium castings were fabricated using the centrifugal vacuum casting method with different mold temperatures of $200{\sim}500^{\circ}C$. The resulting castings were characterized by optical microscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy and vicker,s hardness tester. Results: In case of the mold temperatures over $400^{\circ}C$, the porosity, surface crack and large grain size were observed in resulting castings. Conclusion: In this work, The most suitable mold temperature in casting of pure titanium was $300^{\circ}C$.

전부도재관 기법 개선에 관한 연구 (A Study on improvements in manufatured technique of all Ceramic Crown)

  • 신무학;김연수;최운재;정희선
    • 대한치과기공학회지
    • /
    • 제23권2호
    • /
    • pp.9-15
    • /
    • 2002
  • A new kind of 'All Ceramic Crown' could be manufactured by making improvements in the manufacturing technique for the current 'All Ceramic Crown' which does not use a special ceramic but rather a general one as a substitute. If we use the manufacturing technique for the 'All Ceramic Crown', metal coping and core are not produced. The effects of the new manufacturing technique for the 'All Ceramic Crown' are as follows: First. We do not need to use new material or special machinery or tools. Second. We can use general machinery and tools. Third. Using the basic 'All Ceramic Technique', we anticipate improvement in learning in our students. Forth. We can save effort, materials and time. Fifth. The technique also has advantages for esthetic 'temporary crown'.

  • PDF

관교의치용 Ni-Cr 합금의 주조성에 관한 연구 (Study on the Casting Ability of Ni-Cr Alloys for Crown and Bridge)

  • 이인규;김연수
    • 대한치과기공학회지
    • /
    • 제10권1호
    • /
    • pp.47-54
    • /
    • 1988
  • The purpose of this study is to evaluate the castability of Ni-Cr alloys for crown and bridge. New young, Hi-Crown and CB-80 which are widely used in dental laboratory were chosen, casting and increased the temperature of furnace 100$^{\circ}C$ of each 7 grades from 600$^{\circ}C$ to 1200$^{\circ}C$. The results are as follows : 1. CB-80 is the most prominent castability among the three Ni-Cr alloys which are Hi-Crown, New-young and Hi-Cr. 2. The good burning temperatures of casting for CB-8p are 900$^{\circ}C$, 100$^{\circ}C$ and 1100$^{\circ}C$ which are obtained four complate casting body of five former patterns. 3. The most proper burning temperature for three Ni-Cr alloys is 900$^{\circ}C$.

  • PDF

백색광과 청색 LED 방식의 광학스캐너로 채득된 디지털 모형의 비교분석 (Comparative analysis on digital models obtained by white light and blue LED optical scanners)

  • 최석순;김재홍;김지환
    • 대한치과기공학회지
    • /
    • 제36권1호
    • /
    • pp.17-23
    • /
    • 2014
  • Purpose: The purpose of this study was to analyze and compare the relative accuracy of digitized stone models of lower full arch, using two different scanning system. Methods: Replica stone models(N=20) were produced from lower arch acrylic model. Twenty digital models were made with the white light and blue LED($Medit^{(R)}$, Korea) scanner. Two-dimensional distance between the landmarks were measured on the Delcam $CopyCAD^{(R)}$(Delcam plc, UK). Independent samples t-test was applied for comparison of the groups. All statistical analyses were performed using the SPSS software package(Statistical Package for Social Sciences for Windows, version 12.0). Results: The absolute disagreement between measurements made directly on the two different scanner-based dental digital models was 0.02~0.04mm, and was not statistically significant(P>0.05). Conclusion: The precision of the blue LED optical scanner was comparable with the digitization device, and relative accuracy was similar. However, there still is room for improvement and further standardization of dental CAD technologies.

임상 실습을 중심으로한 치기공(학)과 교육 실태조사 (A Study on the education status in department of Dental Technology (Focusing on the Dental Laboratory practice education))

  • 박종희
    • 대한치과기공학회지
    • /
    • 제37권3호
    • /
    • pp.131-144
    • /
    • 2015
  • Purpose: This study set out to propose plans for more efficient and effective clinical practice by investigating the current state of clinical practice in the field of dental technology and thus provide basic data to develop pre- and post-education programs for clinical practice. Methods: The subjects include dental technicians at dental technical laboratories that were appointed as the place of clinical practice by the Department of Dental Technology of G University. The survey period spanned from December 22, 2014 to January 20, 2015. Total 250 questionnaires were distributed to them, and 190(76.0%) were returned. After excluding 23 whose answers were uncertain or seemed to lack reliability, total 167(66.8%) were used in final analysis. Results: 1. The most frequent practice the student did during clinical practice was articulator attachment, which was followed by pin operation or model making, one's own task and practice, sand and crow sculpturing, burying, casting, and grinding. 2. In case of going through the entire process, porcelain had the most students at 39(23.4%), being followed by crown & bridge at 28(16.8%), clinical model at 23(13.8%), full denture at 17(10.2%), and partial denture at 17(10.2%) in the order. 3. Of the students, 59.8%(30.5% for reinforced basic practice; 29.3% for intensive practice education) said that intensive practice education should be reinforced in school; and 22.3% said that intensive theory and practice education was needed, which indicates that 82.6% voiced their opinion of reinforcing education around practice. 4. The students felt that they lacked diligence, passion, and theoretical knowledge somewhat and were relatively good at clinical adaptation and operational skills. Conclusion: The findings show that the students felt an absolute lack of practice education as the school education was focused on theory and national exams in the field of dental technology, thus raising a need to reinforce practice education. Of all the respondents, 62.9% said there was a need to improve the current education with a focus on jobs. In future, education of dental technology should work to bring up able dental technicians that can perform in clinical dental technology right after graduation by reinforcing job-based practice education.

친환경 칫솔의 효과와 만족도 (Effects and satisfaction of eco-friendly toothbrush)

  • 강경희;박성은;고승지;김나현;김유경;장성주;최연주
    • 미래기술융합논문지
    • /
    • 제2권4호
    • /
    • pp.49-56
    • /
    • 2023
  • 본 연구는 친환경적 칫솔과 일반 칫솔의 치면세균막 제거율을 비교 분석하고, 설문지를 통하여 연구 대상자들의 칫솔에 대한 만족도를 조사하여 친환경 구강용품의 효과와 인식에 대하여 알아보고자 하였으며, 이를 통하여 친환경 구강용품에 대한 소비자의 관심을 환기하고 구강용품 선택에 있어 다양한 선택의 기준을 제시하는데 목적이 있다. 연구결과 친환경 칫솔과 일반칫솔의 칫솔 종류별 치면세균막 제거율에 유의미한 차이가 나타나지 않은 것으로 보아, 친환경 칫솔의 기능은 일반 칫솔의 기능과 별다른 차이가 없는 것을 알 수 있었으며, 친환경 칫솔에 대한 만족도가 전반적으로 긍정적이었기 때문에 앞으로 미래사회의 더 나은 환경을 위해 소비자들이 친환경 칫솔을 선택하도록 하기 위해서는 친환경 구강위생용품에 대한 관심 증대를 목표로 한 지속적인 홍보와 개발이 선행되어야 할 것으로 보인다.

치과 보철물 제작시 사용되는 Sprue의 재료 및 형태가 비귀금속 합금의 주조성에 미치는 영향에 관한 연구 (A Study on the Castability of Base Metal Alloys Which Sprue Shape and materials used in the Production of Dantal Prosdontics)

  • 최운재;신무학;김연수
    • 대한치과기공학회지
    • /
    • 제21권1호
    • /
    • pp.87-96
    • /
    • 1999
  • In order to examine the influence of sprue(used to make crown supplements) on casting, 3 kinds of sprue materials(wax, wood, plastic) and 3 types of sprue(round, square, triangle) were made and buried and cast, then the comparison and analysis of casting characters among sprue materials and among sprue type show the following results : 1. The comparison of casting characters in accordance with sprue materials shows wax sprue of 83.3%, wood sprue 81.3%, and plastic sprue of 80.7%, Wax sprue was the bast materials for casting, However there was no statistically significant difference of casting characters among was, plastic and wood. 2. The comparison of casting in accordance with sprue types shows square sprue of 94.0%, round sprue of 86.9% and triangle sprue of 84.2%. square sprue had a best casting character. 3. When a ring cast using wood sprue was classified from burying materials. its cutting of casting body and sprue indicated much more than any other sprue material. It seems to be caused by the influence of wood residuals and carbon occurrence.

  • PDF

멀티미디어를 이용한 치과환자교육 시스템 개발 (Development of Dental Patient Education System using Mutimedia)

  • 김무성;이승진;남기곤;김형일;이영우;전계록
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 추계학술대회
    • /
    • pp.52-56
    • /
    • 1996
  • The elevation of present medical service using advanced science contributes to offer medical examination and treatment of good quality under the subject of patient satisfaction as well as patient impression. The dental service field charging some part of public health promotion and public welfare promotion also intends to improve the dental examination and treatment quality utilizing advanced science. The object of this research is the development of dental patient education system (DPES) using multimedia of new technology. DPES can be employed for these object, harmonious operation of dental examination and treatment, treatment quality improvement, disease notice to patient under the subject of patient satisfaction and patient impression, explanation of some selective treatment course, the verification of treatment necessities and treatment validation, and the improvement of treatment effect through the oral cavity sanitation education in the sense of prevention. This research also serves the development environment, the step to collect educational document, visual information and to structure those, and the examination of DPES efficiency in clinic.

  • PDF

VITA VM9 Zirconia powder를 이용한 Cerec inlab의 임상증례에 관하여 (Clinical Experiment Results of Cerec Inlab using Vita9)

  • 정효경;김정숙;이종도
    • 대한치과기공학회지
    • /
    • 제29권2호
    • /
    • pp.119-128
    • /
    • 2007
  • Although there are many different ways that restorations can be made, it can be said that the biocompatibility of abutment and crown is very important in this experiment. When placed in the actual oral cavity, the differences were obvious. Compared to In-ceram Aluminium, the structure that is obtained after firing reveals a particularly homogeneous distribution of the crystal and glass phase. The In-ceram aluminium system had many problems, such as having weak tensile strength, and having low bonding strength due to the shrinking that occurs after firing. Because of the opaque finish of the metal frame, the two may look similar from the outside, but it is evident that there are differences between using a metal frame and In-ceram. VITA VM9 has been designed as a special ceramic featuring a fine structure or stabilized Zro2 substructures, and so the VITA VM9 excels in its light refraction and reflection behavior, which is similar to natural teeth. It also has outstanding chemical balance, which presents advantages such as considerably reduced accumulation of plaque on the ceramic surface.? This ultimately results in easier care and cleaning for the patient.

  • PDF

치과기공사의 신체자각증상과 건강행위 실천의 관련성 (The Relationship between Physical Subjective Symptoms and Practice of Health Behavior of Dental Technicians)

  • 권은자;한민수;오선미
    • 한국산학기술학회논문지
    • /
    • 제12권10호
    • /
    • pp.4484-4492
    • /
    • 2011
  • 본 연구는 치과기공사의 자각증상과 건강행위 실천도를 분석하고 그 상관관계를 알아보기 위해 서울시, 인천시, 전북지역의 치과기공사 250명을 선정하고 자기 기입식 설문지를 이용하여 2010년 10월 11일부터 11월 25일까지 조사를 실시하였다. 수집된 자료의 분석결과, 자각증상 전체 평균은 2.83으로 비교적 높게 나타났으며, 건강행위 실천의 영역별 전체 평균은 2.76으로 나타났다. 자각증상과 건강행위 실천의 상관관계를 분석한 결과 대부분의 변수가 유의한 수준의 역 상관관계로 나타나 작업 시 건강행위 실천도가 높을수록 신체적 자각증상은 낮아지는 것으로 나타났다. 연구결과, 치과기공사의 작업장 환경 개선과 건강행위를 실천하여 건강을 유지하기 위한 노력이 필요할 것으로 생각된다.