• 제목/요약/키워드: Dept. of dental technology

검색결과 523건 처리시간 0.019초

지대치의 재료와 Clasp 재료 사이의 마찰계수와 원형 clasp의 유지력 추정 (Fiction Coefficient between Abutment Materials and Clasp Materials and Estimation of Retention Force of Circumferential Clasp)

  • 임동천
    • 대한치과기공학회지
    • /
    • 제21권1호
    • /
    • pp.67-75
    • /
    • 1999
  • The purpose of this study is to evaluate the friction coefficients between abutment materials and clasp materials, and to an estimation formula for retention force. The coefficients of friction between three clasp materials and four abutment materials were measured under various conditions, polished and sandblasted and wet and dry. The measurement was repeated for each combination up to a total measurement of 1200 times. Estimation formula for retention force is measured as sum of two terms, which the one time is proportional to the product of friction coefficient ${\mu}$ and undercut u and the other term is proportional to u-squared. Two proportional coefficient were obtained by least square method. The results are as follows: 1. Friction coefficients were ranged from 0.08 to 0.53 under various conditions. 2. Friction coefficients of non-metal abutment materials are greater in wet conditions than dry conditions. 3. Friction coefficients of sandblasted clasp against abutment are greater than that of polished clasp. 4. Clasp retention force can be estimated with the model as F=$F_d(3.0{\mu}u+1.5u^2/h)$ with minor error.

  • PDF

Ring Furnace를 이용한 Acrylic Resin의 온성에 관한 연구 (A Study on the Heat-Curing of Acrylic Resin using Ring Furnace)

  • 최석순
    • 대한치과기공학회지
    • /
    • 제13권1호
    • /
    • pp.27-31
    • /
    • 1991
  • The purpose of this study was to evaluate the effect of curing time and curing temperature on the hear - Curing of acrylic resin using ring furnace. Specimens were fabricated from 2 kinds(Laboron, Bertex) heat-cured resin. Total 200 samples were divided into 4 groups(70$^{\circ}C$, 100$^{\circ}C$, 13$^{\circ}C$, 150$^{\circ}C$) and each group was divided into 5 small groups(30 min., 45min., 60min., 75min., 90min.). A microscope(Olympus Coll Co. Japan) was used to examine a randomly selected central zone, midzone and surface for each complete specimen. The results of the experiment were as follows : 1. To obtain non-polymerzation, cure the resin for 30 minutes at 70$^{\circ}C$ and 100$^{\circ}C$ in a ring furnace. 2. To obtain with porosity, cure the resin for 45 minutes, 60 minutes and 75 mintes at 70$^{\circ}C$ and for 90 minutes at 150$^{\circ}C$ in ring furnace. Porosity appears in Laboron for 30 minutes, 45 minutes at 150$^{\circ}C$ in a ring furnace. 3. Every other specimens connot get a sight of special problem with makes eye in the made surface.

  • PDF

주조 시 발생되는 porosity가 sprue의 길이와 굵기에 따라 주조체에 미치는 영향에 관한 실험적 연구 (An Experiment on How the Length and the Diameter of the sprue Effects the Size of the porosity, that is Created During the Moduling Process)

  • 황성식
    • 대한치과기공학회지
    • /
    • 제22권1호
    • /
    • pp.13-20
    • /
    • 2000
  • This experiment was done to find out how the length and the diameter of the sprue effects the porosity created during the moduling process, which is caused by the metal's shrinking and stretching action. the experiment was done in two groups(A and B), using experimental gold, and made 10 copings for both groups. 1. In group A, The length of the sprues were given the same, but the diameter of the sprue were 6, 8, 10, 12, 18 gauge. As a result, the porosity came out big with 12 and 18 gauge and for 10, 8, 6 gauge, the porosity was hardly seen or none was noticeable. 2. In group B, the diameter was given the sam for the sprues, but the length of the sprues were 5, 10, 15, 20, 25mm. As a result, the porosity came out big with 25, 20, 15mm the porosity was hardly seen or none was noticeable. 3. The diameter needs to be big and the length, short. 4. The appropriate sized sprue must be chosen for each individual tooth, according to it's shape and size.

  • PDF

금속.도재수복물용 금속의 열처리 및 표면처리에 따른 변형에 관한 연구 (An Experimental Study of Marginal Distortion Related to Heat treatment and Surface Treatment in Metal Copings for Metal-Ceramic Restorations)

  • 김웅철
    • 대한치과기공학회지
    • /
    • 제14권1호
    • /
    • pp.45-54
    • /
    • 1992
  • The purpose of this study was to observe the change of marginal distortion related to heat treatment and surface treatment in. Thirty copings were made on the self-curing resin dies and twenty coping among them were treated by heat and surface grinding. All copings were adapted on the respective dies and then were invested into the plastic boxes with tray resin. Both copiong and die invested in tray resin were cut through labio-lingually by a separating disc. This cross-cutting surface was ground and polished. Specimens were mounted on a light microscope and photographed. Marginal discrepancies were measured on photographes by a scale. The obtained results could be summarized in the followings : 1. In all metal copings, the distortion of cervical margin was shown after heat treatment and surface treatment. 2. There were no statistically significant differences in marginal fitness between shoulder and deep chamfer. 3. There were no statistically significant differences in marginal fitness between labial margin and lingual margin in one die. 4. In case of the copings which were not treated with preheating and were treated with surface grinding, the marginal distortion shows a tendency to increase.

  • PDF

Ti-Nb계 합금의 세포독성에 관한 연구 (A study on cytotoxicity of Ti-Nb alloys)

  • 박효병
    • 대한치과기공학회지
    • /
    • 제25권1호
    • /
    • pp.89-94
    • /
    • 2003
  • The use of titanium alloys as biomaterials is increasing due to their superior biocompatibility and enhanced corrosion resistance compared to conventional stainless steels and cobalt-based alloys. Ti-6Al-4V ($\alpha+\beta$type) alloy instead of pure titanium ($\alpha$type) is being widely used as biomaterials has some characteristics such as high fatigue strength, tensile strength and corrosion resistance. It also has similar characteristics to Ti in inducing bony ingrowth. But it has been reported recently that the vanadium element expresses cytotoxicity and carcinogenicity and the aluminium element is related with dementia of Alzheimer type and neurotoxicity. In order to overcome their detrimental effects, $\beta$-phase stabilizer Nb was chosen in the present study. CP-Ti(ASTM grade 2), Ti-3wt.%Nb($\alpha$type), Ti-20wt.%Nb ($\alpha+\beta$type) and Ti-40 wt.%Nb($\beta$type) alloys were melted by vacuum arc furnace. Biocompatibility of Ti-Nb alloys was evaluated by cytotoxicity test. The results can be summarized as follows: 1. For the cytotoxicity test, Ti-Nb alloys showed excellent biocompatibility compared to CP-Ti(ASTM grade 2), 316L STS and Co-Cr alloys.

  • PDF

치과 임플란트 스크루 풀림토크 개선용 DLC 박막 코팅에 관한 연구 (A Study on the DLC Film Coating for Improving Loosening Torque of Dental Implant Screw)

  • 정운조;조재철
    • 전기학회논문지
    • /
    • 제67권10호
    • /
    • pp.1375-1381
    • /
    • 2018
  • In this paper, we studied coatings of the DLC thin film for improving loosening torque of dental implant screw. We used a filtered arc ion plating process which can realize the most dense DLC layer by coating the DLC thin film on the surface of the dental abutment screw. It showed both hardness comparable to diamond and low friction coefficient similar to graphite, and to improve the loosening phenomenon by increasing the screw tightening force Cr/CrN, Ti/TiN or Ti/TiN/Cr/CrN buffer layers were deposited for 5 to 10 minutes to improve the adhesion of the DLC thin film to the surface of the Ti (Gr.5), and then the DLC thin film was coated for about 15 minutes. As a result, the Cr/CrN buffer layer exhibited the highest hardness of 29.7 GPa, the adhesion of 18.62N on average, and a very low coefficient of friction of less than 0.2 as a whole. And we measured loosening torque after one million times with masticatory movement simulator. As a result, the values of the coated screw loosening torque were clearly higher than those of the uncoated screw. From this, it was found that the DLC coating was effective methods improving the loosening torque. In addition, it was confirmed that the cytotoxicity test and cell adhesion test showed high biocompatibility.

S. mutans에 항균력(抗菌力)을 나타내는 균주(菌株)의 배양학적(培養學的) 성질(性質) (Nutritional and Cultural characterizations of microorganism capable of producing antagonistic activity against Streptococcus mutans)

  • 박명호
    • 대한치과기공학회지
    • /
    • 제21권1호
    • /
    • pp.139-144
    • /
    • 1999
  • 토양시료로부터 치아우식원인균인 S. mutans에 대하여 항균력을 나타내는 방선균주를 순수분리하여 분리균주를 공시균주로 하여 항생물질 생성에 미치는 환경인자를 규명하였다. 본 공시균주의 항생물질 생성 최적배지조성은 Bacto-soytone 1%, glucose 1%, NaCl 0.5%, $CaCO_3$ 0.1% 였으며 배지의 초기 pH는 7.0이었다. 또한 항생물질은 $28^{\circ}C$에서 진탕배양시 생성의 최적조건이었으며 본 공시균주는 24시간 유도기를 거쳐 배양 72시간째 항생물질의 생성과 더불어 균의 최대증식도를 나타내었다.

  • PDF

색소체용액 침투가 지르코니아 및 전장용 세라믹의 전단결합강도에 미치는 영향 (Influence of coloring liquids on the shear bond strength between zirconia and veneering ceramic)

  • 정종현;오계정
    • 대한치과기공학회지
    • /
    • 제38권4호
    • /
    • pp.291-298
    • /
    • 2016
  • Purpose: This study was to evaluate the effect of coloring liquids on the shear bond strength between zirconia and veneering ceramic. Methods: Zirconia(15 mm in diameter, 2.5 mm in thickness; n=40) used in the experiment were divided into 5 groups depending on the coloring liquid. Each specimen were polished using a polishing machine(LaboPol-2, Struers, UK). A cylinder of veneering porcelain(6 mm in diameter, 3 mm in thickness) was fabricated and fired on zirconia surfaces. The shear bond strength was measured using a universal testing machine(Model 4302, Instron, USA). All data were analyzed statistically using a one-way ANOVA and Tukey's multiple comparisons test. After the shear bond test, fracture surfaces were examined by SEM. Results: Colored zirconia showed a higher shear bonding strength than that of uncolored zirconia except for colored zirconia immersed in Zirkonzahn coloring liquid. In particular, colored zirconia immersed in Kuwotech coloring liquid showed the highest shear bond strength. After the shear bond test, mixed failure patterns were mainly observed in the failure between zirconia and veneering ceramic. Conclusion: Coloring liquid enhanced the shear bond strength zirconia and veneering ceramic than uncolored zirconia.

$Al_2O_3$ sandblasting과 Silicoating이 titanium과 레진시멘트의 접착강도에 미치는 영향 (Effect of $Al_2O_3$ Sandblasting and Silicoating on Bond Strength of a Resin Cement to Titanium Implant)

  • 최병환;하정윤
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.67-73
    • /
    • 2012
  • 연구 목적: 임플란트의 하부구조를 상부 구조와 연결하는 레진시멘트의 접착강도를 높이기 위한 기계적 화학적인 표면처리 방법들이 연구 되고 있다. 이 연구에서 다양한 크기의 $Al_2O_3$ sandblasting과 Silano Pen으로 표면처리한 티타늄과 레진 시멘트의 접착강도를 알아보고자 한다. 연구 방법: 12개의 티타늄(Ti-6A1-4V)시편을 디스크 형태로 제작하여 자가중합 수지에 매립하였다. 이들을 각각 6개의 군으로 나누어 $50{\mu}m$, $90{\mu}m$, $110{\mu}m$ 등 3가지 크기의 $Al_2O_3$로 sandblasting 하는 조건과 $Al_2O_3$로 sandblasting한 후 Silano Pen(Bredent, bredent GmbH &Co.KG, Senden, Germany)을 사용한 군으로 나누었다. 표면처리 한 티타늄 표면에 레진시멘트(Duolink dual syringe, Bisco, USA)으로 접착하였다. 그 후 증류수($37^{\circ}C$)에 24시간 보관 후 접착강도 실험을 시행하였고, SEM을 사용하여 표면처리 한 표면과 접착강도 실험 후 파절양상을 관찰하였다. 결과: 통계학적 분석에 따르면 Silano Pen을 사용하여 표면처리한 군들의 접착강도가 높았다(P<0.05). 결론: Silano Pen을 사용하는 것이 티타늄과 레진시멘트의 접착강도를 증가 시킨다.

도재용착주조관 변연의 적합성에 관한 연구 II (A Study of Margin Fitness in Metal-bond Porcelain Crown II)

  • 이인규
    • 대한치과기공학회지
    • /
    • 제5권1호
    • /
    • pp.27-30
    • /
    • 1983
  • 적은 경비로써 보다 양호한 치경부의 적합과 Shade를 얻고 치경부의 변색을 막기 위하여 도재소부용 귀금속과 비금속, 그리고 귀금속과 비금속위에 도금을 하는 4가지 유형으로 나누어 실험하였던 바 다음과 같은 결과를 얻게 되었다. 1. 도재소부용 귀금속으로 치관전체를 주조하는 경우는 수축율이 적고 연성이 뛰어나 경비가 많이 소요된다. 2. 비금속으로 치관전체를 주조하는 경우는 경비는 저렴하나 치경부의 적합성이 금속에 따라 차이가 있으며 그 중 Gemini II가 가장 우수하였다. 3. 비금속으로 치관 전체를 주조하고 10K의 Gold로 도금하는 경우는 적합성에서는 비금속과 동일하나 도금이 고리게 되지 않고 Shade에서도 별 효과가 없었다. 4. 치관의 윗부분은 비금속으로 먼저 주조하여 Degassing한 후 나머지 2mmwjd도의 치경부를 귀금속으로 주조하는 경우는 치경부의 적합성은 귀금속과 동일하게 우수하고 경비 또한 매우 저렴하였다.

  • PDF