• Title/Summary/Keyword: Deposited dust

Search Result 49, Processing Time 0.025 seconds

Rapid climate change during the deglaciation of Lake Hovsgol, Mongolia

  • Chun, Jong-Hwa;Cheong, Dae-Kyo
    • Proceedings of the Korean Quaternary Association Conference
    • /
    • 2005.10a
    • /
    • pp.34-39
    • /
    • 2005
  • A 120-cm core recovered from Lake Hovsgol, the northern Mongolia provides evidence for climate variability since the Marine Isotope Stage 3, representing a sharp lithological change. The lowermost part of the core consists of diatom-barren calcareous silty clay without coarse sands, framboidal pyrite, and biogenic components deposited during the MIS 3. Following the last glacial maximum, in-situ moss is included in the sediments, as lake-level was retreated by cold and dry environment with low precipitation. The AMS radiocarbon ages of the plant fragments match a marked lithologic boundary between 14,060 and 14,325 $^{14}C$ yr BP. The contents of coarse sands abruptly increase, indicating probably wind-derived sandy dust or coarse grains contributed from floating icebergs. And abundant framboidal pyrite grains were deposited in an anoxic environment, as reflected by high accumulation of organic matters at a low lake stand. During the deglaciation, quantities of coarse sands, ostracod, shell fragments, framboidal pyrite, and diatom markedly varies by regional and global scale climate regimes. Some allochthonous coarse sands were probably ice-rafted debris derived from floating icebergs. A rapid increase in diatom productivity probably marked the onset of Bolling-Allerodwarming. Subsequent high concentration of framboidal pyrite probably represents a dry and cold condition, such as Younger Drays events. Consistent warm period with high precipitation at Holocene is documented by diatomaceous clayey ooze without framboidal pyrite, coarse sands, and ostracod.

  • PDF

Contamination Characteristics of Heavy Metals in Indoor, Outdoor and Playground of Schools in the Gochang-Gun, Chonbuk Province of South Korea (전북 고창지역 학교 실내외 환경의 중금속 오염 특성)

  • Kim, Yong-Hwan;Chung, Duk-Ho;Cho, Kyu-Seong
    • Journal of the Korean earth science society
    • /
    • v.27 no.1
    • /
    • pp.73-82
    • /
    • 2006
  • Dust samples were collected from 10 middle and high schools in the Gochang-Gun, Korea. Heavy metal concentrations were determined for the dry-deposited dusts from indoor and outdoor of classroom and playground of each sampling site. Concentrations of Cd, Cu, Pb and Zn in indoor's dusts were highly concentrated. Also concentrations of Cu, Ni, Pb and Zn in outdoor's dusts were highly concentrated. Concentrations of Cd, Cu and Zn in the dusts were much higher than the world average contents in soil and environmental orientation value. These levels are similar to those of the dust samples at middle schools and high schools located in Jeonju-city, Korea. Compared with concentrations of heavy metals in soils and dusts in Korea, the environment of indoor and outdoor of classroom is highly concentrated except for Cu, Zn. The concentrations of playground is less than that of residential dust and main road dust and playground in Jeonju-city. Playground dusts in 1 school exhibited the enhanced heavy metal pollution with a pollution index (Kloke, 1979) greater than 1.0, but indoor and outdoor dusts in 7 schools exhibited the enhanced heavy metal pollution with a pollution index (by Kloke) yester than 1.0.

Study of Catalytic Filter on the Removal of Dust and HVOC (촉매필터를 이용한 먼지 및 HVOC 제거 특성 연구)

  • Jeong, Soon Kwan;Park, Young Ok
    • Applied Chemistry for Engineering
    • /
    • v.19 no.1
    • /
    • pp.80-85
    • /
    • 2008
  • Catalytic filter is capable of performing shallow bed dust filtration plus a catalytic reaction, promoted by a catalyst deposited in its inner structure. Such a feature may allow potential cost and space reduction in several environmental applications. Dust filtration and halogenated volatile organic compound (1,2-dichlorobenzene) destruction were carried out in a lab-scale reactor. $WO_3-V_2O_5/TiO_2$ supplied by MaGreen, which showed high catalytic acitivity at low temperature, was used as a catalyst. P-84 that can be operated under $250^{\circ}C$ was used as a felt. The catalytic activity and filtration efficiency of catalytic filters were investigated under the operating conditions, including temperature, face velocity, and dust concentration. The catalytic activity of catalytic filter increased with increasing temperature and the amount of catalyst loaded. The test results showed that the filtration efficiency was primarily affected by the face velocity. Pressure drop variations as a function of time were investigated for a variety of conditions. In case of virgin filter, a dramatic decrease in the pulse interval and a slightly increase in the base line pressure drop were observed. A relatively slow pressure drop build-up was recorded for the catalytic filter due to smooth and slippery surface characteristics of nanofiber. The catalytic filter indicated that high filtration efficiency over 99.98% and high catalytic activity over 90% at 1 m/min and $210^{\circ}C$.

Calculation of the Theoretical Total Amount Ratio of Di(2-ethyl-hexyl) Phthalate in Indoor Air and Floor Dust in a Test House (모의 실험주택 모니터링 결과를 활용한 실내공기 및 바닥먼지 중 Di(2-ethyl-hexyl) phthalate (DEHP)의 이론적 총량 비율 산출)

  • SaHo Chun;Khawon Lee;SeungJung Kim;SeungPyo Jung;DaYoung Kang;Ki-Tae Kim
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.6
    • /
    • pp.324-333
    • /
    • 2023
  • Background: Human exposure to phthalates in indoor environments occurs via dermal absorption, oral ingestion of indoor dust, and inhalation of indoor air. However, systematic studies to investigate the exposure rate to phthalates among the three exposure routes in indoor environments are currently limited. Objectives: A theoretical exposure ratio between inhalation and oral exposure was calculated based on the total amount of di(2-ethyl-hexyl) phthalate (DEHP) emitted into indoor air and deposited into floor dust in a test house. Methods: Flooring and wallpaper containing DEHP were installed in a test house and the concentration of DEHP in both indoor air and floor dust were monitored for five months. Based on the measured DEHP concentrations, the theoretical total amount ratio of DEHP that could be exposed through inhalation and oral ingestion was calculated. Results: Considering the period of operation in the test house, the theoretical total amount of DEHP through inhalation and oral ingestion exposures in the entire test house space was calculated to be 0.014 mg and 5.5 mg, respectively. The exposure ratio of the two routes between inhalation and oral exposure corresponding to the total DEHP amount in flooring and wallpaper was 6.0×10-7% and 2.3×10-4%, indicating that theoretical oral exposure to DEHP is approximately 380 times higher than inhalation. Conclusions: Monitoring results from a test house has shown that oral exposure is the main exposure route for DEHP in indoor environments. The experimental design employed in this study and theoretical exposure ratio obtained can be applied to investigate actual exposure to DEHP and to determine the exposure characteristics of various types of semi-volatile organic compounds.

Reconstruction of Changes in Eolian Particle Deposition Across the Mid-Pleistocene Transition in the Central Part of the North Pacific (중기 플라이스토세 전이기 전후 북태평양 중앙 해역 퇴적물에 기록된 풍성 퇴적물 입자 퇴적 양상 변화 복원)

  • Lee, Sojung;Seo, Inah;Hyeong, Kiseong
    • Ocean and Polar Research
    • /
    • v.41 no.4
    • /
    • pp.275-288
    • /
    • 2019
  • We investigated flux, grain size distribution, Nd-Sr isotope composition, mineral composition, and trace metal composition (REEs and Sc) of inorganic silicate fraction (ISF, mainly Asian dust with an unrestricted amount of volcanic materials) deposited during 600~1000 ka across the Mid-Pleistocene Transition at core NPGP 1401-2A (32°01'N, 178°59'E, 5205m) taken from the central part of the North Pacific. Our results reveal about a 2-fold increase in ISF flux after 800 ka, which is associated with an increase in La/Sc and a decrease in mean grain size. Asian dusts are finer than volcanic materials and La/Sc increases with the enhanced contribution of Asian dusts. Thus, increased flux after 800 ka can be explained by the increased contribution of Asian dusts relative to volcanic materials, likely due to an intensified Westerly Jet (WJ) and the drying of the Asian continent after the MPT. Mean grain size of ISF varies systematically in relation to glacial-interglacial cycles with a decrease during glacial stages, which is consistent with the previous results in the study area. Such a cyclical pattern is also attributed to the increase in the relative contribution of Asian dusts over volcanic components in glacial stages due to intensified WJ and drying of the Asian continent. Thus, it can be concluded that climate changes that had occurred across the MPT were similar to those of interglacial to glacial transitions at least in terms of the dust budget. Different from the Shatsky Rise, however, compositional changes associated with glacial-interglacial mean grain size fluctuations are not observed in Nd-Sr isotope ratios and trace element composition in our study of the Hess Rise. This may be attributed to the location of the study site far (> 4,000 km) from the volcanic sources. The volcanic component at the study site comprises less than 10% and varies within 3% over glacial-interglacial cycles. Such a small variation was not enough to imprint geochemical signals.

The Study on the Seasonal Variations and Chemical Compositions of Atmospheric Deposition Flux Measured with Dustfall around Tae-an peninsula (태안반도주변 강하분진량의 계절변화와 그 성상에 관한 연구)

  • Chun, Sang-Ki;Kim, Yong-Chul;Lee, Sung-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.7 no.2
    • /
    • pp.127-133
    • /
    • 1998
  • The atmospheric deposition flux was measured with dustfall from July of 1997 to July of 1998 at nine sampling sites located in Tae-an peninsula to examine the seasonal variations. The results showed that the average dry deposition was higher in spring than the other seasons. Thus, it is considered that yellow sand is one major source of the additional deposition flux in spring. There also appeared the higher measurement of deposition at the sites nearby road (like Hagampo, Bangali and Sinduri) in summer, and it is assumed that the heavy traffic caused by summer visitors was the main factor of that. For more accurate study, the qualitiative analysis should be taken on the deposited materials.

  • PDF

The Development Plan of Salt Contamination Map Using GIS (지리정보 시스템을 이용한 전국 염해 오손도 구축 방안)

  • Kang, Yeon-Woog;Kwak, Joo-Sik;Shim, Eung-Bo;Yoo, Chol-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.377-379
    • /
    • 2001
  • Contamination flashover is responsible for insulator electrical failures. Particularly, in Korea, with its perennially dry spring, the first spring rain often cause serious line outages by forming a conductive liquid film on the insulator surface. Rainwater and fog are not normally conductive but unfortunately atmospheric dust deposited on the insulator surface contains soluble salts which may lead to bad condition of insulation by combining watery and salts. Transmission design engineers have used a contamination map drawn on the traditional paper map. But it is not convenient because it does not include the information of Geographic Information accurately. This paper explains the newly developed salt contamination map program using Geographic Information System, which provide accurate geographic information. The program is designed to use four parts of datum, salt contamination levels, 345kV & 154 kV transmission lines, power plants & substations and background map. The digital background map is composed of raster files, the others are done by vector map.

  • PDF

Damage Measurement for Molybdenum Thin Film Using Reflection-Type Digital Holography (반사형 디지털 홀로그래피를 이용한 Molybdenum 박막의 손상 측정)

  • Kim, Kyeong-Suk;Jung, Hyun-Il;Shin, Ju-Yeop;Ma, Hye-Joon;Kwon, Ik-Hwan;Yang, Seung-Pill;Hong, Chung-Ki;Jung, Hyun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2015
  • In the fabrication of electronic circuits used in electronic products, molybdenum thin films are deposited on semiconductors to prevent oxidation. During the deposition, the presence of a particle or dust at the interface between the thin film and substrate causes the decrease of adhesion, performance, and life cycle. In this study, a damage measurement targeting two kinds of glass substrate, with and without particles, was performed in order to measure the change in the molybdenum thin film deposition area in the presence of a particle. Clean and dirty molybdenum thin film specimens were fabricated and directly deposited on a substrate using the sputtering method, and a reflection-type digital holographic interferometer was configured for measuring the damage. Reflection-type digital holography has several advantages; e.g., the configuration of the interferometer is simple, the measurement range can be varied depending on the magnification of a microscopic lens, and the measuring time is short. The results confirm that reflection-type digital holography is useful for the measurement of the damage and defects of thin films.

Study on the Regional Deposition of Smoke Particles in Human Respiratory Tract under the Variation of Fire and Breathing Conditions (화재 및 호흡조건 변화에 따른 연기입자의 인체 호흡기 내 영역별 침착량 분석)

  • Goo, Jaehark
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.95-104
    • /
    • 2019
  • Smoke generated in a fire consists of gaseous substances and particulate matter, such as unburned carbon that adsorbed the gases. Human injury caused by inhalation of gaseous substances present in smoke is mostly short-term, whereas damage caused by inhalation of particulate matter is relatively a long-term phenomenon depending on the state of the gas-phase adsorption. The amount and location of the deposited smoke particles are important factors in estimating the damage caused to humans, which are affected by the breathing conditions as well as particle conditions, such as the size and concentration affected by the combustion conditions. In this study, in order to understand the characteristics of the deposition of smoke particles in the respiratory tract related to the study of human smoke inhalation injury, the number and mass concentration of smoke particles deposited in different areas of the respiratory tract for different fuel types, combustion conditions and breathing conditions were calculated. In addition, the amount of mass deposition of smoke in the respiratory tract for a certain period of inhalation was compared with the atmospheric standard of fine dust.

A Case of Pulmonary Siderosis Confirmed by Bronchoalveolar Lavage and Transbronchial Lung Biopsy (기관지 폐포 세척술 및 경피적 폐 생검술로 확진된 철폐증 1례)

  • Kim, Eun A;Bang, Byoung Uk;Kim, Lucia;Ryu, Jeon Seon;Kwak, Seung Min;Lee, Hong Lyeol;Cho, Jae Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.5
    • /
    • pp.476-479
    • /
    • 2004
  • Pulmonary siderosis is one kind of pneumoconiosis, occurs from chronic inhalation of iron or iron oxide. Inhaled iron dust is deposited in the intra-alveolar spaces, which leads to radiological changes and respiratory symptoms. It is diagnosed by iron exposure history, radiological changes, and the evidence of intra-alveolar iron deposit. We have experienced a case of pulmonary siderosis which was confirmed by bronchoalveolar lavage and transbronchial lung biopsy, so report it with a review of literature.