• 제목/요약/키워드: Depletion simulation

검색결과 139건 처리시간 0.032초

낙동강 유역의 지속적인 이용을 위한 미래예측 (Simulating the Future of Nakdong River Basin for the Sustainable Use)

  • 김진이;이석모
    • 한국환경과학회지
    • /
    • 제10권4호
    • /
    • pp.253-258
    • /
    • 2001
  • A macroeconomic minimodel was simulatedto suggest the public for sustainable us of Nakdong River Basin. The minimodel for the simulation shows the interrelationships between natural environment and economic activity. Topsoil, water, economic assets, and money stock are plotted for 300 years, beginning with 1996 in each simulation. The computer simulation runs suggest that the Nakdong River Basin system in the near future may strongly be influenced by the favorable availability of outside resources, while the economic assets and money stock may be declined by indigenous environmental stock depletion. The simulation run made under the constant decrease in systems purchased inputs with investment ratio of developed country and for sustainable use. The results of simulation shows the recover of natural environment and decrease of economic activity under these condition. Therefore, the economic structure of Nakdong River Basin should be transformed from the present industrial structure to the social-economic structure based on an ecological-recycling concept which depend on renewable resources rather than industrial structural which depend on outside resources.

  • PDF

Rao-Blackwellized 파티클 필터에서 파티클 생존을 위한 전략 게임 (Strategic Games for Particle Survival in Rao-Blackwellized Particle Filter for SLAM)

  • 곽노산
    • 로봇학회논문지
    • /
    • 제4권2호
    • /
    • pp.97-104
    • /
    • 2009
  • Recently, simultaneous localization and mapping (SLAM) approaches employing Rao-Blackwellized particle filter (RBPF) have shown good results. However, due to the usage of the accurate sensors, distinct particles which compensate one another are attenuated as the RBPF-SLAM continues. To avoid this particle depletion, we propose the strategic games to assign the particle's payoff which replaces the importance weight in the current RBPF-SLAM framework. From simulation works, we show that RBPF-SLAM with the strategic games is inconsistent in the pessimistic way, which is different from the existing optimistic RBPF-SLAM. In addition, first, the estimation errors with applying the strategic games are much less than those of the standard RBPF-SLAM, and second, the particle depletion is alleviated.

  • PDF

Galactic gas depletion process in cosmological hydrodynamic cluster zoom-in simulation

  • Jung, Seoyoung;Choi, Hoseung;Yi, Sukyoung K.
    • 천문학회보
    • /
    • 제42권2호
    • /
    • pp.76.1-76.1
    • /
    • 2017
  • In cluster environments, most of the galaxies are found to be red and dead, but the origin of these passive galaxies is not yet clearly understood. Using a set of cosmological hydrodynamic zoom-in simulations, we study gas depletion process in and outside clusters. Our results are consistent with previous studies showing rapid stripping of a galactic cold gas reservoir during the first infall to the cluster center. Moreover, we found a fraction of galaxies that were already in the gas deficient state before reaching the cluster (i.e., pre-processed galaxies) is non-negligible. These findings lead to the idea that a complete understanding of passive galaxy population in clusters can not be achieved without a detailed understanding of gas stripping process in group size halos prior to the cluster infall.

  • PDF

$SrTiO_3$ 바리스터의 전기적 등가회로 (Electric equivalent circuit of $SrTiO_3$-based varistor)

  • 강대하;노일수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권8호
    • /
    • pp.907-918
    • /
    • 2006
  • In this study capacitance and dielectric loss factor were measured with low-voltage signal and the simulation of equivalent circuits for the data was conducted. As the result it was shown that the equivalent circuit model considered the grain-boundary structure with semiconducting layer, dielectric layer and depletion layer was well approximated with the observed data. Various parameters were determined by a optimum curve-fitting method and could be used to analyze the characteristics of varistor. It also seems that the proposed equivalent circuit model will be adopted for other BL type varistors.

Thermal oxidation을 이용한 결정질 실리콘 태양전지의 selective emitter 형성 방법에 대한 simulation (The Simulation of Selective Emitter Formation for Crystalline Silicon Solar Cell by Growing Thermal Oxide)

  • 최용현;손혁주;이인지;박재근;박용환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.53.1-53.1
    • /
    • 2010
  • 결정질 실리콘 태양전지의 효율을 향상시키기 위하여 수광면에 서로 다른 도핑농도를 가지는 고농도 도핑영역과 저농도 도핑영역으로 이루어진 emitter를 형성하는 것이 요구되며 이를 selective emitter라 칭한다. Selective emitter를 형성하면 고농도 도핑영역에서 금속전극과 저항 접촉이 잘 형성되기 때문에 직렬 저항이 최소화되고 저농도 도핑영역에서는 전하 재결합의 감소로 인하여 태양전지의 변환효율이 상승하는 이점이 있다. Selective emitter의 형성방법은 이미 다양한 방법이 제안되고 있으나, 본 연구에서는 기존에 제시된 방법과는 다르게 열산화 시 dopant redistribution에 의한 Boron depletion 현상을 이용하여 selective emitter를 형성하는 방법을 제안하였고, 이를 Simulation을 통하여 검증하였다. 초기 emitter 확산 후 junction depth는 0.478um, 면저항은 $104.2{\Omega}/sq.$ 이었으며, nitride masking layer 두께는 0.3um로 설정하였다. $1100^{\circ}C$에서 30분간 습식산화 공정을 거친 후 nitride mask가 있는 부분의 junction depth는 1.48um, 면저항은 $89.1{\Omega}/sq$의 값을 보였고, 산화막이 형성된 부분의 junction depth는 1.16um, 면저항은 $261.8{\Omega}/sq$의 값을 보였다. 위 조건의 구조를 가진 태양전지의 변환 효율은 19.28%의 값을 나타내었고 Voc, Jsc 및 fill factor는 각각 645.08mV, $36.26mA/cm^2$, 82.42%의 값을 보였다. 한편 일반적인 구조로 설정한 태양전지의 변환 효율, Voc, Isc 및 fill factor는 각각 18.73%, 644.86mV, $36.26mA/cm^2$, 80.09%의 값을 보였다.

  • PDF

정속도 유도발전기를 포함한 풍력발전단지 시모의 해석 알고리즘 (Time Domain Simulation Analysis Algorithm For Wind Farms including Fixed-Speed Wind Turbines)

  • 조성구;송화창;이장호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.480_481
    • /
    • 2009
  • As a result of increasing environmental concern, the penetration of renewable power on power systems is now increasing. Wind energy can be considered as the most economical energy sources to generate electricity without depletion of fossil fuel. To devise adequate control strategies for wind farms, time domain simulation analysis needs to be performed. This paper presents a time domain simulation method for wind farms with fixed speed wind turbines (FSWT) connected to the external power systems. In this paper, an example of time simulation of the wind farm with four FSWT.

  • PDF

이중 여자 비동기 발전기를 포함한 풍력단지 시모의 해석 (Time Domain Simulation Analysis For Wind Farm with DFAG)

  • 조성구;송화창;이장호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.439-442
    • /
    • 2009
  • As a result of increasing environmental concern, the penetration of renewable power on power systems is now increasing. Wind energy can be considered as the most economical energy sources to generate electricity without depletion of fossil fuel. The penetration of wind energy from wind farm is getting larger and larger, so we need adequate control strategies for wind farm. To devise adequate control strategies for wind farm, time domain simulation analysis needs to be performed. This presents a Simultaneous Implicit-based time domain simulation algorithm for wind farm with DFAG (Doubly Fed Asynchronous generator) connected to the external power systems. This paper shows an illustrative example with a 5-bus test system.

  • PDF

무선 센서네트워크에서의 효과적인 에너지 활용 시뮬레이션 (Simulation for the Efficient Utilization of Energy in Wireless Sensor Network)

  • 백승범;조대호
    • 한국시뮬레이션학회논문지
    • /
    • 제14권3호
    • /
    • pp.33-42
    • /
    • 2005
  • One of the imminent problems to be solved within wireless sensor network is to balance out energy dissipation among deployed sensor nodes. In this paper, we present a transmission relay method of communications between BS (Base Station) and CHs (Cluster Heads) for balancing the energy consumption and extending the average lifetime of sensor nodes by the fuzzy logic application. The proposed method is designed based on LEACH protocol. The area deployed by sensor nodes is divided into two groups based on distance from BS to the nodes. RCH (Relay Cluster Head) relays transmissions from CH to BS if the CH is in the area far away from BS in order to reduce the energy consumption. RCH decides whether to relay the transmissions based on the threshold distance value that is obtained as a output of fuzzy logic system, Our simulation result shows that the application of fuzzy logic provides the better balancing of energy depletion and prolonged lifetime of the nodes.

  • PDF

모노파일 해상풍력발전의 이송과 설치를 위한 일정계획 및 비용분석 시뮬레이션 (Scheduling and Cost Estimation Simulation for Transportation and Installation of the Offshore Monopile Wind Turbines)

  • 김보람;손명조;장왕석;김태완;홍기용
    • 한국CDE학회논문집
    • /
    • 제20권2호
    • /
    • pp.193-209
    • /
    • 2015
  • For reasons such as global warming, depletion of fossil fuels and the danger of nuclear energy the research and development of renewable energy is actively underway. Wind energy has advantages over another renewable energy in terms of location requirements, energy efficiency and reliability. Nowadays the research and development area is expanded to offshore because it can supply more wind reliability and free from noise pollution. In this study, the monopile offshore wind turbine transportation and installation (T&I) process are investigated. In addition, the schedule and cost for the process are estimated by discrete event simulation. For the simulation, simulation models for various means of T&I are developed. The optimum T&I execution plan with shortest duration and lowest cost can be found by using different mission start day and T&I means.

연속 시적분 (CTI) 기반 풍력발전단지 시모의 해석 (Continuation Time Integration (CTI)-Based Time Domain Simulation Analysis for Wind Farms)

  • 조성구;송화창;이장호
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.1971-1979
    • /
    • 2010
  • As a result of increasing environmental concern, the penetration of renewable power on power systems is now increasing. Wind energy can be considered as the most economical energy sources to generate electricity without depletion of fossil fuel. To devise adequate control strategies for wind farm, time domain simulation analysis needs to be performed. This presents a continuation time integration (CTI)-based time domain simulation algorithm for wind farm with doubly fed asynchronous generator (DFAG) connected to the external power systems. This paper depicts how to time trajectories are traced using CTI-based time domain simulation. Also this paper describes the possibilities of hierachical control for wind farm output limitation, and the coordinated control has been designed by hierarchical control structured from central control level to wind farm control board and to an individual wind turbine level. Finally it shows an illustrative example of time domain simulation result with two test systems through case study.