• Title/Summary/Keyword: Department of Radiologic Science

Search Result 343, Processing Time 0.033 seconds

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

Evaluating the Effects of Inferiority Management Using a Group Counseling Program for University Students in Health Science (보건계열 대학생의 집단상담 프로그램을 활용한 열등감 관리의 효과 분석)

  • Lee, Myung Hwa;Park, Young Joon;Jang, Hyon Chol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.557-563
    • /
    • 2019
  • The objective of this study was to identify factors affecting the positive and negative responses of undergraduate students to inferiority by using a group counseling program to manage the inferiority of undergraduate students majoring in health science. This study sampled 30 undergraduate students attending the health science department of S University and divided them into a treatment group and a control group. The treatment group received an inferiority management group counseling program twice a week 120 minutes each from November 20, 2018, to January 2, 2019 eight sessions in total. The inferiority response criterion was applied before-treatment, after-treatment, and follow-up to verify the effectiveness of the program. The analysis results showed that the inferiority management group counseling program significantly decreased the negative response of undergraduate students to inferiority and significantly increased the positive response to inferiority. These results suggest that the inferiority management counseling program can lower the negative attitude and enhance the positive attitude toward the inferiority, which is caused by comparing themselves with their peers.

The Effect of Source to Image-Receptor Distance(SID) on Radiation Dose for Digital Chest Radiography (Digital Chest Radiography에서 방사선량에 대한 Source to Image-Receptor Distance (SID)의 영향)

  • Kwon, Soonmu;Park, Changhee;Park, Jeongkyu;Son, Woonheung;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.203-210
    • /
    • 2014
  • Chest radiography has been typically performed at SID of 180 cm. Image quality and patient dose were investigated between 180 cm and 340 cm by 20 cm intervals at 120 kVp and 320 mAs with the AEC. VGA was performed for qualitative assessment and SNR was analysed for quantitative assessment on the image of the chest phantom. Patients dose was measured by ESAK and PCXMC was used for effective dose. As a result, when using the standard of SID of 180 cm which is typically used in the clinical practice, in the case of ESAK, 240 cm, 280 cm, and 320 cm were 8.7%, 11.47%, and 13.56% respectively therefore significant reduction was confirmed. In the case of effective dose, 2.89%, 4.67%, and 6.41% in the body and 5.08%, 6.09%, and 9.6% in lung were reduced. In the case of SNR, 9.04%, 8.24%, and 11.46% were respectively decreased especially, by 8.03% between SID of 260 cm and 300 cm, but SNR was 5.24 up to 340 cm. There were no significant differences in VGA thus the image is valuable in diagnosis. It is predicted that increasing SID up to 300 cm in digital chest radiography can reduce patient dose without decreasing image quality.

A Study on Activities of Diagnostic X-ray Examination(II) (X선진단(X線診斷) 부문(部門)에 있어서 업무량(業務量)에 관(關)한 조사연구(調査硏究)(II))

  • Kyong, Kwang-Hyon;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1978
  • This study was carried out with statistical materials during the last two years of period from Jan. 1975 to Dec. 1976 which presented at radiologic department of 5 hospitals in Seoul City. The primary purpose of this study was to obtained more detailed informations related to the activities of radiologic technologists in diagnostic X-Ray examinations part and to provide some basic materials for managements in activities of then and manpower managements of their organization and practice. From the results of this study, the following conclusions were obtained [1] During two year from the January of 1975 to the December of 1976, total number of case in X-ray examinations were 464,830 case and 22,029 case in 1975 and 24,461 in 1976. And ratio of icreased in X-Ray examinations by year was 11.09 per cent. [2] Regarding the examined portion of X-Ray examination, a great propotion was chest examination as 56.88 per cent. [3] An average, the required time per case in X-Ray exam. was 9.28 minutes and make used of 1.94 sheets of X-Ray film per case in radiography. [4] An average, ratio of increased in X-Ray film by year was 12.71 per cent and ratio of failed film in it was 2.23 per cent. [5] The frequency rate of film size showed the highest distribution of $8"{\times}10"$(28.17%) and the highest distribution of X-Ray film by month was July(8.93%). [6] An average, the amount of activities per a diagnostic X-Ray equipment was 34.92 case and make used of 67.81 sheets of X-Ray film in a day. [7] The mean number of case in X-Ray examinations by radiologic technologists was 29.29 cases and make used of 56.87 sheets of X-Ray film in a day. Also, the average number of case was reading by radiologists was 32.42 case and 62.97 sheets of X-Ray film in a day.

  • PDF

Manufacture of Immobilization Device (Vac-lok) and the Usefulness of Evaluation for Reproducibility of Patients in the Radiotherapy (환자의 재현성을 위한 고정장치(Vac-lok) 제작과 방사선치료에서 유용성 평가)

  • Lee, Jae-Seung;Kim, Gyoung-Hee;Jeong, Kyu-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Park, Cheol-Woo;Im, In-Chul;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.8-16
    • /
    • 2011
  • We manufactured the Vac-lok that can be applied to patient of special body shape and need to special set-up position and evaluated the usefulness in the radiation therapy. The manufacture Vac-lok, It was used EVA resin and biobeadform of a diameter 1.5 mm. carried out the test of functionality, structural and analyzed the relative reproducibility of phantoms and patients. During the total period of radiation therapy, Vacuum pressure bring variety to a very small amount in the test of functionality of the manufacture Vac-lok. But It was a negligible quantity. The manufacture Vac-lok improved the relative reproducibility of phantoms than the existing Vac-lok and tolerance has a confidence less than 4% error. Also, relative reproducibility of patient increased error than phantom in the antero-posterior and lateral plan. However, the maximum set-up error was less than ${\pm}\;2.3$ mm. In conclusion, If tolerance set-up error of radiotherapy is less than ${\pm}\;3$ mm, the manufacture Vac-lok was enough possible to use and improvement of reproducibility, considering supply with the Vac-lok made to measure of special patient that produced at a low price and without delay.

Education Satisfaction by Students in Department of Radiologic Science according to Educational System (학제에 따른 방사선(학)과 학생의 교육만족도)

  • Gil, Jong-Won;Choi, Sung-Oog
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.343-349
    • /
    • 2016
  • This study evaluated the education satisfaction targeting a total of 600 people including 300 students from Department of Radiology (collage) and 300 students from Department of Radiology (4 years college) in Daejeon and Gyeongsangbuk-do regions from April 8, 2015 to June 18. As a result, the students from Department of Radiology of 4 year collage have higher satisfaction than collage(p<0.001). Also, although male students and lower grades had higher educational satisfaction but only significant from partial items(p<0.05, p<0.01, p<0.001). To higher the education satisfaction of the students of Department of Radiology of 3-year collage, development and application of new and professional industrial-educational cooperation programs rather than having various subjects would be more effective method.

A Study on the Feasibility of a National Practical Examination in the Radiologic Technologist (방사선사 실기시험제도 도입의 타당성 연구)

  • Son, Soon-Yong;Kim, Tae-Hyung;Min, Jung-Whan;Han, Dong-Kyoon;Ahn, Sung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2149-2162
    • /
    • 2011
  • Currently practical examination can't function as a practical technique ability evaluation', so there is a contradiction which even though a radiologist passed an examination for license, he has to complete a training course. To improve this problem, this study tried to deduce the most reasonable plan from the analysis of propriety of currently practical examination and what improvement points are. This conduct study was compared and analyzed the performance or practical examination of radiology from leading advanced countries within the samples of 634 radiologists, 56 professors of radiology. From the result of this study, it showed that radiology practical examination was difficult to be substituted by radiology clinical training since there were some critical differences between conditions of domestic and advanced countries. Therefore, the introduction of the radiology practical examination is inevitable and necessary. However the currently practical examination can't evaluate actual practical ability, so we could conclude that converting it into OSCE (objective structured clinical examination) form is essential. From now on, we should consider more about an in-depth study on types of advanced practical examination and how to suggest and present them in order to become an one of the advanced countries for radiologic technologist.

The Use of Continuous Confidence Judgments in ROC of Digital Radiography (디지털 X선영상 평가에서 연속확신도법 ROC의 적용)

  • Kim, Hark-Sung;Lee, In-Ja;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.147-151
    • /
    • 2009
  • In general, the discrete confidence judgments that use five-step assessment method have been used to assess the medical images by ROC. TPF or FPF can be computed easily with this independent reading test. However, during experiments, it happens frequently that adequate distribution for observers is required to smoothly estimate the ROC curve. In addition, data becomes invalid for distribution of the created categories. To solve such problems or to apply the ROC interpretation to data that is not obtained from the experimental observation, the continuous confidence judgements (CCJ) has been proposed, which implements ROC interpretation using continuously-distributed experimental results without category classification has been used. As the use of CCJ to assess medical images was barely reported in Korea, we applied it to the assessment of chest digital images in this study. The results showed that a smooth ROC curve was obtained conveniently by the commercialized program and the characteristic value was measured easily. Therefore, it is recommended that this method can be applied to the assessment of digital medical images.

  • PDF

The Actual State and the Utilization for Dental Radiography in Korea (국내 치과방사선의 현황 및 이용 실태)

  • Shin, Gwi-Soon;Kim, You-Hyun;Lee, Bo-Ram;Kim, Se-Young;Lee, Gui-Won;Park, Chang-Seo;Park, Hyok;Chang, Kye-Yong
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.109-120
    • /
    • 2010
  • The purpose of this study was first to analyze the utilization of dental examination through questionnaire to develop a diagnostic reference level of patient doses for dental radiography in korea. 77 dental institutions were classified into three groups: A group for the dental hospitals of the college of dentistry (11 institutions), B group for dental hospitals (30 institutions) and C group for dental clinics (36 institutions). The results were as follows : The mean numbers of unit chairs and medical staffs were 140.2, 15.3 and 5.8 sets, 112.6, 7.3 and 1.7 dentists, 3.1, 0.5 and no one radiologic technologists, and 19.7, 12.5 and 3.3 dental hygienists in A, B and C groups, respectively. The mean numbers of dental X-ray equipments were 14.64, 3.21 and 2.19 in A, B and C groups, respectively. Intraoral dental X-ray unit was used the most, the following equipments were panoramic, cephalometric, and cone-beam CT units. The most used X-ray imaging system was also digital system (above 50%) in all three groups. Insight dental film (Kodak, USA) having high sensitivity was routinely used for periapical radiography. The automatic processor was not used in many dental institutions, but the film-holding device was used in many dental institutions. The utilization rates of PACS in A, B and C groups were 90.9%, 83.3% and 16.7% respectively, and the PACS software program was used the most PiView STAR (Infinitt, Korea). The annual mean number of radiographic cases in one dental institution in 2008 for A group was 6.8 times and 21.2 times more than those for B and C groups, and periapical and panoramic radiographs were taken mostly. Tube voltage (kVp) and tube current (mA) for periapical radiography were similar in all three groups, but exposure time in C group was 12.0 times and 3.5 times longer than those in B and C groups. The amount of radiation exposure in C group, in which dental hygienists take dental radiographs, was more than those in other groups. The exposure parameters for panoramic radiography were similar in all three groups. In conclusion, the exposure parameters in dental radiography should be determined with reference level, not past experiences. Use of automatic processor and film-holding devices reduces the radiation exposure in film system. The quality assurance of dental equipments are necessary for the reduction of the patient dose and the improvement of X-ray image quality.

Effectiveness of Bismuth Shield to Reduce Eye Lens Radiation Dose Using the Photoluminescence Dosimetry in Computed Tomography (CT 검사에서 유리선량계를 이용한 수정체의 비스무트 차폐 효과)

  • Jung, Mi-Young;Kweon, Dae-Cheol;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.307-312
    • /
    • 2009
  • The purpose of our study was to determine the eyeradiation dose when performing routine multi-detector computed tomography (MDCT). We also evaluated dose reduction and the effect on image quality of using a bismuth eye shield when performing head MDCT. Examinations were performed with a 64MDCT scanner. To compare the shielded/unshielded lens dose, the examination was performed with and without bismuth shielding in anthropomorphic phantom. To determine the average lens radiation dose, we imaged an anthropomorphic phantom into which calibrated photoluminescence glass dosimeter (PLD) were placed to measure the dose to lens. The phantom was imaged using the same protocol. Radiation doses to the lens with and without the lensshielding were measured and compared using the Student t test. In the qualitative evaluation of the MDCT scans, all were considered to be of diagnostic quality. We did not see any differences in quality between the shielded and unshielded brain. The mean radiation doses to the eyewith the shield and to those without the shield were 21.54 versus 10.46 mGy, respectively. The lens shield enabled a 51.3% decrease in radiation dose to the lens. Bismuth in-plane shielding for routine eye and head MDCT decreased radiation dose to the lenswithout qualitative changes in image quality. The other radiosensitive superficial organs specifically must be protected with shielding.

  • PDF