• Title/Summary/Keyword: Department of Radiography

Search Result 1,485, Processing Time 0.028 seconds

A Clinical Analysis of the Intestinal Atresia (선천성 장 폐쇄증의 임상적 분석)

  • Park, Jin-Young
    • Advances in pediatric surgery
    • /
    • v.10 no.2
    • /
    • pp.99-106
    • /
    • 2004
  • Intestinal atresia is a frequent cause of intestinal obstruction in the newborn. We reviewed the clinical presentation, associated anomalies, types of atresias, operative managements, and early postoperative complications in 36 cases of intestinal atresia treated at the Department of Surgery, Kyungpook National University Hospital between January 1994 and February 2003. Location of the lesion was duodenum in 17 patients, jejunum in 11 patients and ileum in 8 patients. The male to female ratio was 1:1.4 in duodenal atresia (DA), 2.7:1 in jejunal atresia (JA) and 7:1 in ileal atresia (IA). The most common type was type III (41.1 %) in DA, and type I (52.6 %) in JA and IA. The most common presenting symptoms was vomiting(88.2 %) in DA, but in jejunoileal atresia, vomiting(89.4 %) and abdominal distension(89.4 %) were the most common sign and symptom. All cases of DA were diagnosed by plain abdominal radiography. There were 6 cases of DA with congenital heart disease, 3 cases of DA with Down syndrome and 3 cases of JA with meconium peritonitis. Segmental resection was performed in 13 cases, duodenoduodenostomy in 11 cases, membrane excision in 7 cases, jejunojejunostomy in 2 cases, gastroduodenostomy in 2 cases and ileocolic anastomosis in 1 case. There were 9 postoperative complications including 3 each of anastomotic leakage, wound infection, and intestinal obstruction 3 cases. The mortality rate for DA was 11.8 %(2/17). Both deaths in DA were attributed to congenital heart disease. The mortality rate for JA was 18% (2/11). Both cases died with sepsis and short bowel syndrome.

  • PDF

A Study on the Radiography for Sharpness the Image of the Sternum Bone in X-ray Thoracic Cage (가슴우리 X-ray 촬영에서 복장뼈의 선예한 영상을 얻기 위한 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.329-336
    • /
    • 2021
  • The Study studied the Inspection Method of Images to obtain a sharp image of the Costume among the bones Composed of Thoracic Using the Thoracic Cage Rando Phantom. At 80 cm of the phantom Distance at the X-ray tube focus, the position of the Phantom was Examined by Changing the Rt and Lt Posterior Oblique(LAO) and Rt and Lt Posterior Postero Oblique positions by 20°, 25° and 30°. The acquired images were Subjectively Evaluated by the Radiographer, and the Evaluation data were analyzed as SPSS ver. 3.0. The signal-to-noise ratio (SNR) was Calculated using the ImageJ Program. As a result, the Cronbach Alpha value was Significantly higher at 0.789. The results of the Signal-to-Noise Ratio (SNR) were high at 20° to 6.038 in the right posterior Transcription Direction at the time of Examination and 7.860, in the Supine Position, for images of Sternum bones. In conclusion, it is Believed that the patient position can be obtained from the Right Anterior Oblique(RAO) Position 20° if the X-ray technique is used to obtain the Sternum's advanced image, and the Left Anterior Oblique(LAO) Position 25° when filming in the Rght lying position.

Analysis of Congenital Postaxial Polydactyly of the Foot Using Magnetic Resonance Imagings (족부에 발생한 선천성 축후성 다지증에 대한 자기공명영상 검사 결과 분석)

  • Woo, Sang Hyun;Baek, Hyeon Seok;Kim, Young Kyu;Choi, Jun Young
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.530-539
    • /
    • 2018
  • Purpose: We aimed to evaluate the magnetic resonance imaging (MRI) findings of congenital postaxial polydactyly of the foot. Materials and Methods: Three-hundred and forty-seven feet of 288 patients who underwent congenital postaxial polydactyly or polysyndactyly correction were divided into five subtypes according to the radiographic shapes of deformity origins (widened metatarsal head, bifid, fused duplicated, incompletely duplicated, or completely duplicated). MRIs were assessed to determine whether they unrevealed areas were fused or separated. MRI was also used to assess cases with radiographic phalangeal aplasia. Results: Huge variations were noted in MRIs. Fusion or separation at the base or head between original and extra digits were observed, and MRI effectively depicted phalangeal aplastic areas. Conclusion: MRI evaluations of congenital postaxial polydactyly of the foot are useful for determining the anatomical statuses which were not visualized by plain radiography (level of evidence: 3).

Comparative Validation of the Mixed and Permanent Dentition at Web-Based Artificial Intelligence Cephalometric Analysis (혼합치열과 영구치열 환자를 대상으로 한 웹 기반 인공지능 두부 계측 분석에서의 비교 검증)

  • Shin, Sunhahn;Kim, Donghyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.85-94
    • /
    • 2022
  • This retrospective study aimed to evaluate the difference in measurement between conventional orthodontic analysis and artificial intelligence orthodontic analysis in pediatric and adolescent patients aged 7 - 15 with the mixed and permanent dentition. A total of 60 pediatric and adolescent patients (30 mixed dentition, 30 permanent dentition) who underwent lateral cephalometric radiograph for orthodontic diagnosis were randomly selected. Seventeen cephalometric landmarks were identified, and 22 measurements were calculated by 1 examiner, using both conventional analysis method and deep learning-based analysis method. Errors due to repeated measurements were assessed by Pearson's correlation coefficient. For the mixed dentition group and the permanent dentition group, respectively, a paired t-test was used to evaluate the difference between the 2 methods. The difference between the 2 methods for 8 measurements were statistically significant in mixed dentition group: APDI, SNA, SNB, Mandibular plane angle, LAFH (p < 0.001), Facial ratio (p = 0.001), U1 to SN (p = 0.012), and U1 to A-Pg (p = 0.021). In the permanent dentition group, 4 measurements showed a statistically significant difference between the 2 methods: ODI (p = 0.020), Wits appraisal (p = 0.025), Facial ratio (p = 0.026), and U1 to A-Pg (p = 0.001). Compared with the time-consuming conventional orthodontic analysis, the deep learning-based cephalometric system can be clinically acceptable in terms of reliability and validity. However, it is essential to understand the limitations of the deep learning-based programs for orthodontic analysis of pediatric and adolescent patients and use these programs with the proper assessment.

A Study on Oral Health Knowledge, Recognition, Practice and Satisfaction of Patients by Applying a Targeted Program within a Dental Hygiene Process (치위생과정에서의 일부 프로그램 적용에 따른 환자의 구강건강지식, 인식, 실천과 만족도 조사)

  • Seong, Mi Kyung;Jo, Moon Mi;Kim, Yu Rin
    • Journal of dental hygiene science
    • /
    • v.17 no.2
    • /
    • pp.183-191
    • /
    • 2017
  • The purpose of this study was to evaluate a clinical preventative care program, based on a dental hygiene process (accessment, diagnosis, planning, implementation, evaluation; ADPIE) in a dental clinic, by analyzing patient recognition, knowledge, practice, and satisfaction with respect to oral health. The collected data (in percentages) were analyzed Fisher's exact test and paired t-test using IBM SPSS ver. 21.0 (IBM Co., USA). This study demonstrated a significant difference in oral health knowledge, recognition, and practice before and after the clinical preventive care program (p<0.05). The results were significant in the individual preventive plan within the planning stage, and in the professional teeth cleaning implementation stage (p<0.05). This result can be attributed to the sympathy of the dental hygienist (p<0.05). There was a positive correlation between recommending dental checkups and regular checking of the (r=0.552, p<0.05), undergoing radiography (r=0.434, p<0.01), following an individual preventive plan (r=0.568, p<0.01), undergoing proximal machine teeth cleaning (r=0.437, p<0.05), following tooth brushing instructions (r=0.552, p<0.05), and the evaluation results (r=1.000, p<0.05). Our results demonstrate, that the clinical preventive care program, based on dental hygiene, is an effective program. Given the positive effect of dental revisits and patient recommendations promoting dental hygienists, it is hoped that this preventative program will be widely used.

Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control (자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가)

  • Young-Cheol, Joo;Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.871-877
    • /
    • 2022
  • This study was conducted to improve the problems of exposure dose and image reading applied to patients due to the incorrect use of AEC during chest radiography. Images were acquired by dividing the case where AEC was used as the test condition and the case where AEC was not used. As a result of the study, the dose was reduced by 1.17% in 110 kVp without AEC than with AEC, 17.2% decrease at 100 kVp, 30.19% decrease at 90 kVp, and 46.45% decrease at 80 kVp. There was a significant difference in the statistical values according to the tube voltage change in the lung, trachea, and heart SNR average values with AEC and without AEC 110 kVp, but the difference in image quality was insignificant in actual images. When AEC was not applied at the same tube voltage, the dose could be reduced by 17.2% while maintaining the image quality similar to that of with AEC at 100 kVp without AEC. Therefore, rather than relying on AE conditions during chest radiographic examination, it is considered that the conditions should be considered for the examination while lowering the dose by selecting an appropriate tube voltage.

Influences on Radiation Safety Management Practice of General Characteristics and Radiation Safety Management Practice for Dental Hygienists in Busan and Gyeongnam Province (부산.경남 일부지역 치과위생사들의 일반적 특성과 방사선 안전관리 특성이 방사선 안전관리 실천에 미치는 영향)

  • Seong, Mi-Kyung;Jang, Kyeung-Ae
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.264-270
    • /
    • 2013
  • This research, which was conducted for dental hygienists, intended to check out what factors have an influence on their practices by knowledge and attitude on radiation safety management (RSM). This study performed a survey on such an issue from July 2 to August 30, 2012 for 220 dental hygienists who worked in Busan, Gyeongnam areas. The data was analysed using the IBM SPSS Statistics 21.0 program. The results were as follows: As a result of the knowledge according to the general characteristics and RSM, a statistically meaningful difference was found according to the education on radiation and wearing apron. As for the attitude according to the general characteristics and RSM, a statistically meaningful difference was found according to the education on radiation and wearing apron. As to the practice according to the general characteristics and RSM, a statistically meaningful difference was found according to the education on radiation, wearing thermo luminescent dosimeter and wearing apron. When the analysis of safety management practice for radiation was conducted with the independent variables such as knowledge, altitude and health concerns about radiography, it turned out that the factors having an effect on the practice were altitude and health concerns by that order.

Comparison Study of the Pulmonary Function and Serum Carboxyhemoglobin Level Between the Traffic Policmen and Clerk Policemen (교통경찰과 비 교통경찰의 폐기능과 혈중 Carboxyhemoglobin 수치에 대한 비교연구)

  • Kim, Sung Min;Cheon, Gyu Rak;Kim, Young Wook;Kim, Joon Hyung;Lee, Ho Hak;Hong, Soon Chang;Lee, Seung Hee;Park, Sang Joon;Chung, Joon Oh;Kim, Yun Kwon;Kim, So Yon;Kim, Young Jung;Cho, Min Koo;Lee, Gwon Jun;Lee, Kyung In
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.6
    • /
    • pp.560-569
    • /
    • 2003
  • Background : A large number of pollutants such as sulfur dioxide, nitric oxide, carbon monoxide, particulate matter, and ozone influence on the body. These pollutants put a burden on the lung and the sequelae resulting from the oxidative stress are thought to contribute to the development of fibrotic lung disease, emphysema, chronic bronchitis and lung cancer. Also, carbon monoxide generated from the incomplete combustion of carbon-containing compounds is an important component of air pollution caused by traffic exhaust fumes and has the toxic effect of tissue hypoxia and produce various systemic and neurologic complications. The objective of this study is to compare the difference of pulmonary function and serum carboxyhemoglobin(CO-Hb) level between the traffic policemen and clerk policemen. Method : Three hundred and twenty-nine of traffic policemen, and one hundred and thirty clerk policemen were included between 2001 May and 2002 August. The policemen who took part in this study were asked to fill out a questionnaire which included questions on age, smoking, drinking, years of working, work-related symptoms and past medical history. The serum CO-Hb level was measured by using carboxyoximeter. Pulmonary function test was done by using automated spirometer. Additional tests, such as elecrocardiogram, urinalysis, chest radiography, blood chemistry, and CBC, were also done. Results : $FEV_1(%)$ was $97.1{\pm}0.85%$, and $105.7{\pm}1.21%$(p<0.05). FVC(%) was $94.6{\pm}0.67%$, and $102.1{\pm}1.09%$, respectively(p<0.05). Serum CO-Hb level was $2.4{\pm}0.06%$, and $1.8{\pm}0.08%$(p<0.05). After correction of confounding factors (age, smoking), significant variables were FVC(%), $FEV_1(%)$ and serum CO-Hb level(%)(p<0.05). Conclusion : Long exposure to air pollution may influence the pulmonary function and serum CO-Hb level. But, further prospective cohort study will be needed to elucidate detailed influences of specific pollutants on pulmonary function and serum carboxyhemoglobin level.

Analysis of radiation exposure in radiation worker in medical facility and student in clinical practice (의료기관 방사선작업종사자와 임상실습 학생의 피폭선량 분석)

  • Lee, Joo-Ah;Choi, Kwan-Woo;Min, Jung-Whan;Lim, Jong-Cheon;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.442-448
    • /
    • 2016
  • This study was conducted to determine the appropriateness of systemic radiation exposure control for students in clinical practice by comparing radiation exposure in radiography employees at different stations of a hospital with that of students conducting clinical practice using identical stations. Overall, 121 students who conducted clinical practice in the department of radiology area of C university hospital from July 2014 to August 2014 and 62 workers working in the same medical facility (47 in the department of radiology, 8 in the department of radiation oncology, 7 in the department of nuclear medicine) were investigated. The radiation exposure experienced by students was measured for 8 weeks, which is the duration of the clinical practice. Additionally, radiation exposure of workers were classified into 4 groups, department of radiology, department of radiation oncology, and department of nuclear medicine was compared. Dose was measured with OSLD and differences among groups were identified by ANOVA followed by Duncan's multiple range test. Among employees, those in the department of radiology, oncology and nuclear medicine were exposed depth doses of $0.127{\pm}0.331mSv$, $0.01{\pm}0.003mSv$, and $0.431{\pm}0.205mSv$, respectively, while students were exposed to $0.143{\pm}0.136mSv$. Additionally, workers in the department of radiology, oncology and nuclear medicine were exposed to surface doses of $0.131{\pm}0.331mSv$, $0.009{\pm}0.003mSv$, and $0.445{\pm}0.198mSv$, respectively, while students were exposed to $0.151{\pm}0.14mSv$, which was significantly different in both doses (p < 0.01). The average dose that students received is higher than that of the other groups (except for nuclear medicine workers), indicating that further improvements must be made in systemic controls for individual radiation exposure by including the students as subjects of management for protection from radiation.

Evaluation of Image Quality for Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료의 다양한 EPID 영상 질평가)

  • Son, Soon-Yong;Choi, Kwan-Woo;Kim, Jung-Min;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Cho, Jeong-Hee;Lee, Jea-Hee;Jung, Jae-Yong;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.451-461
    • /
    • 2015
  • In megavoltage (MV) radiotherapy, delivering the dose to the target volume is important while protecting the surrounding normal tissue. The purpose of this study was to evaluate the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using an edge block in megavoltage X-ray imaging (MVI). We used an edge block, which consists of tungsten with dimensions of 19 (thickness) ${\times}$ 10 (length) ${\times}$ 1 (width) $cm^3$ and measured the pre-sampling MTF at 6 MV energy. Various radiation therapy (RT) devices such as TrueBeam$^{TM}$ (Varian), BEAMVIEW$^{PLUS}$ (Siemens), iViewGT (Elekta) and Clinac$^{(R)}$iX (Varian) were used. As for MTF results, TrueBeam$^{TM}$(Varian) flattening filter free(FFF) showed the highest values of $0.46mm^{-1}$ and $1.40mm^{-1}$ for MTF 0.5 and 0.1. In NPS, iViewGT (Elekta) showed the lowest noise distribution. In DQE, iViewGT (Elekta) showed the best efficiency at a peak DQE and $1mm^{-1}DQE$ of 0.0026 and 0.00014, respectively. This study could be used not only for traditional QA imaging but also for quantitative MTF, NPS, and DQE measurement for development of an electronic portal imaging device (EPID).