• Title/Summary/Keyword: Denture clinician

Search Result 12, Processing Time 0.021 seconds

Study on Curriculum of Denture clinician (의치사의 교육과정에 관한 연구)

  • Park, Myung-Ho;Bae, Bong-Jin;Lee, Hwa-Sik;Lee, Hee-Kyung
    • Journal of Technologic Dentistry
    • /
    • v.32 no.1
    • /
    • pp.47-56
    • /
    • 2010
  • As Korea is entering an aging society, the number of elderly people who need new denture or who have problems with their existing denture or adjacent tissue is increasing and it will double in 2018. Therefore, denture clinician system will lessen patients financial burden and introduce market economy to the dental prosthesis field. Therefore, Korea needs to adopt denture clinician system as soon as possible as USA or Canada to increase people s accessibility in quality and quantity. Denture clinician will determine the size and shape of denture after performing oral examination, make impression using various materials, fabricate denture, deliver and adjust completed denture to the patient, repair denture, and carry out financial management in the denture fabricating company or manage human resources. Considering denture clinicians services, American and European education system seems to be close to our system. Therefore, in this study, basic curriculums of several countries in Europe and America were reviewed and curriculum that meets Korean situation was suggested.

Comparison between denture wearer's evaluation and clinician's rating for complete denture (총의치 사용에 대한 환자와 술자간 평가 비교)

  • Byun, Jin-Soo;Huh, Yoon-Hyuk;Cho, Lee-La;Park, Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.364-369
    • /
    • 2016
  • Purpose: The aim of this study was to compare denture wearer's evaluation and clinician's technical rating for complete denture used on edentulous patients. Materials and methods: Total 43 edentulous patients who had complete denture fabricated more than one year ago were recalled. The questionnaire based on the various literatures was modified and applied to patients for subjective assessments. Functional aspects related to retention, stability, occlusion and denture condition were included in operator's evaluation. In addition, correlations were evaluated between patient's subjective and operator's objective assessments. Friedman test and Cohen's Kappa value were used for statistical analysis. Results: It was found that denture wearers' evaluations were slightly or fairly agree to clinician's rating for complete denture. More differences were found in maxillary denture than mandibular denture and moderate difference was found in esthetic, occlusion aspects. Conclusion: There were slightly or fairly agreement between subjective and objective evaluations.

ORTHODONTIC TREATMENT RELATED TO FACIAL PATTERNS (안모유형에 따른 교정치료)

  • Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.475-488
    • /
    • 1988
  • Certain malocclusion are associated with specific "facial type," and it is important for the clinician to classify the common facial characteristic of each patient. Because the reaction to treatment mechanics and the stability of the denture is depended upon the analysis of the facial pattern. Basically, there are 3 district facial types or patterns under which almost all malocclusion can be classified. 1. mesofacial is the most average growth. 2. brachyfacial which is a horizontal growth pattern has a week muscle, with dental arch, deep bite. 3. dolichofacial which is a vertical growth pattern has a strong muscle, narrow dental arch, open bite. Brachyfacial pattern show a resistant to mandibular rotation during treatment can accept a more protrusive denture and are prominantly nonextraction, whereas dolichofacial patterns tend to open during treatment require a more retracted denture in order to assure post-treatment stability. Brachyfacial pattern would better treat to use extrusive force system, whereas dolichofacial pattern treat to use intrusive force system with head gear and intermaxillary elastics.

  • PDF

REHABILITATION OF A PATIENT WITH A POST RADIOTHERAPY TRISMUS WITH AN OBTURATOR AND A MAXILLARY DENTURE USING MAGNET ATTACHMENTS

  • Bae, Hanna-Eun-Kyong;Jeon, Jeong-Ho;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.586-590
    • /
    • 2008
  • Construction of an obturator for rehabilitation of a patient who underwent a maxillectomy is vital. Routinely a constructed obturator includes denture portion. A patient who may present anatomical limitations due to surgical or radiotherapy complications often challenges the clinician. Purpose: This clinical report describes a patient with severe trismus after surgical resection and radiotherapy treatment of a tumor in the upper left maxilla. Conclusion: This report describes the concepts of using a rotational path insertion for an obturator and a separately constructed maxillary denture. The stability and retention of the obturator were obtained from anatomical features. Where as these were achieved through magnetic attachments and the remaining edentulous ridge to ensure esthetic and function of the prosthesis.

Implant-assisted removable partial denture for severely atrophied mandible (심한 하악 치조제 흡수를 가진 환자에서 임플란트를 이용한 가철성 국소의치로 수복한 증례)

  • Choi, Bada;Kim, Yeun Ju;Lee, Jae Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.2
    • /
    • pp.171-175
    • /
    • 2019
  • Mandible with severe alveolar bone atrophy poses a significant challenge in terms of reproducing clinically acceptable anatomy for a removable prosthesis. To overcome this potential complication, altered cast impression technique is often recommended to capture accurate and functional gingiva tissues. It becomes possible to get proper anchors functional impression by placing 2 implants crowns which were impossible in previous implant overdenture impression technique. In this case, an 80-year old female patient with severe mandibular ridge atrophy was treated with an implant-assisted removable partial denture with two implant crowns on the canine area. An altered cast impression was taken with an individual tray on a metal framework of removable partial denture on both posterior edentulous areas. The patient was satisfied with the final prosthesis after failure of 2 previous prostheses. Clinician had a difficult time to manage disabled patient and patient were suffered with ill-fitting denture due to inaccurate impression in conventional overdenture condition. The oral rehabilitation was completed with placing 2 implants as proper anchor.

Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study

  • Acharya, Paramba Hitendrabhai;Patel, Vilas Valjibhai;Duseja, Sareen Subhash;Chauhan, Vishal Rajendrabhai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.79-88
    • /
    • 2021
  • Purpose. To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion. Materials and methods. A 3-D finite element model of mandible with D2 bone with partially edentulism with unilateral distal extension was made. Two Ti alloy identical implants with 4.2 mm diameter and 10 mm length were placed in the mandibular second premolar and the mandibular second molar region and prosthesis was given with the mandibular first molar pontic. Vertical load of 100 N and and oblique load of 70 N was applied on occlusal surface of prosthesis. Group 1 was cuspally loaded occlusion with total 8 contact points and Group 2 was implant protected occlusion with 3 contact points. Results. In Group 1 for vertical load, maximum stress was generated over implant having 14.3552 Mpa. While for oblique load, overall stress generated was 28.0732 Mpa. In Group 2 for vertical load, maximum stress was generated over crown and overall stress was 16.7682 Mpa. But for oblique load, crown stress and overall stress was maximum 22.7561 Mpa. When Group 1 is compared to Group 2, harmful oblique load caused maximum overall stress 28.0732 Mpa in Group 1. Conclusion. In Group 1, vertical load generated high implant stress, and oblique load generated high overall stresses, cortical stresses and crown stresses compared to vertical load. In Group 2, oblique load generated more overall stresses, cortical stresses, and crown stresses compared to vertical load. Implant protected occlusion generated lesser harmful oblique implant, crown, bone and overall stresses compared to cuspally loaded occlusion.

Fiber-Reinforcements of Composite Restorations

  • Cho, Kyung-Mo
    • Proceedings of the KACD Conference
    • /
    • 2001.05a
    • /
    • pp.258-258
    • /
    • 2001
  • Fiber-reinforced materials have highly favorable mechanical properties. and their strength-to-weight ratios are superior to those of most alloys. When compared to metals they offer many other advantages as well. including non-corrosiveness. translucency. good bonding properties. and ease ofrepair. Fiber-reinforced materials can be categorized to pre-impregnated. impregnation required. dental laboratory products. chairside products and prefabricated posts. so it is not suprising that fiber-reinforced composites have potential for use in many applications in dentistry. Fiber-reinforced materials can be utilized in frameworks for crowns. anterior or posterior fixed prostheses. chairs ide tooth replacements. periodontal splints. customized posts. prefabricated posts. orthodontic retention. denture reinforcements and in implants dentistry. To realize the full potential of using fiber-reinforced composite restorations. it is essential that the clinician and laboratory technician understand concepts of tooth preparation and framework design. Also practitioner may appreciate the background information and other details about the materials themselves so that identify the rationale for their use in various clinical situations. select well-suited materials. and carry out related procedures. Understanding the material properties and take many attentions. fiber-reinforced materials will give more esthetic. more easy. more strong and more reliable restorations.ations.

  • PDF

Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report (하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례)

  • Lee, Eunsu;Park, Juyoung;Park, Chan;Yun, Kwi-Dug;Lim, Hyun-Pil;Park, Sangwon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.34-41
    • /
    • 2022
  • Recently, digital technology and computer-aided design/computer-aided manufacturing (CAD/CAM) environment have changed the clinician treatment method in the fabrication of dentures. The denture manufacturing method with CAD/CAM technology simplifies the treatment and laboratory process to reduce the occurrence of errors and provides clinical efficiency and convenience. In this case, complete dentures were fabricated using stereolithography (SLA)-based 3D printing in patient with mandibular deviation. Recording base were produced in a digital model obtained with an intraoral scanner, and after recording a jaw relation in the occlusal rim, a definitive impression was obtained with polyvinyl siloxane impression material. In addition, facial scan data with occlusal rim was obtained so that it can be used as a reference in determination of the occlusal plane and in arrangement of artificial teeth during laboratory work. Artificial teeth were arranged through a CAD program, and a gingival festooning was performed. The definitive dentures were printed by SLA-based 3D printer using a Food and Drug Administration (FDA)-approved liquid photocurable resin. The denture showed adequate retention, support and stability, and results were satisfied functionally and aesthetically.

Evaluation of occlusal strength using T-Scan Novus and Dental prescale II in dental prosthodontic treatments: A case report (보철물 수복 형태에 따른 T-Scan Novus와 Dental prescale II를 이용한 교합력 평가 활용 증례)

  • Su-Hyun Choi;Yu-Sung Choi;Jong-Hyuk Lee;Seung-Ryong Ha
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.160-178
    • /
    • 2023
  • Diagnosis and analysis of occlusal relationships are important factors in prosthetic treatment. A thorough occlusion analysis and evaluation should be performed before treatment to restore a stable interocclusal relationship. Analysis and evaluation are essential during the treatment process and at regular follow-ups. Recently, with the development of dental equipment and digital processing methods, new quantitative analysis methods that can record the patient's occlusal relationship have been introduced. Among them, the T-Scan Novus (Tekscan Inc., S. Boston, MA, USA) displays the strength of the initial contact point and the occlusal contact point of the teeth using a pressure sensor. With this, occlusal contact time of the teeth, anteroposterior and left-right balance of occlusal force can be compared. The Dental prescale II (GC Co., Tokyo, Japan) scans the occlusal contact point using a pressure-sensing film and analyzes the density of the contact point. It can measure the distribution and strength of the occlusal force of the teeth in the most natural occlusion state. Based on this, appropriate prosthetic treatment (four-unit fixed partial denture, removable partial denture, complete denture, and complete oral restoration cases) was performed according to the area and extent of the patient's tooth loss. The patient's occlusion at the first visit, treatment stage, right after treatment, and regular follow-up were compared and evaluated using a quantitative method for appropriate occlusion analysis using T-Scan Novus and Dental prescale II. This report enhances the understanding of occlusion analysis during prosthetic restoration. The results satisfied both the clinician and patients in terms of function and aesthetics.

Application of 3D printer in dental clinic (치과 진료실에서 3D 프린트의 활용)

  • Kim, Hyun Dong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.27 no.2
    • /
    • pp.82-96
    • /
    • 2018
  • 3D printing is a process of producing 3d object from a digital file in STL format by joining, bonding, sintering or polymerizing small volume elements by layer. The various type of 3d printing is classified according to the additive manufacturing strategies. Among the types of 3D printer, SLA(StereoLithography Apparatus) and DLP(Digital Light Processing) 3D printer which use polymerization by light source are widely used in dental office. In the previous study, a full-arch scale 3d printed model is less precise than a conventional stone model. However, in scale of quadrant arch, a 3d printed model is significantly precise than a five-axis milled model. Using $3^{rd}$ Party dental CAD program, full denture, provisional crowns and diagnostic wax-up model are fabricated by 3d printer in dental office. In Orthodontics, based on virtual setup model, indirect bracket bonding tray can be generated by 3d printer. And thermoforming clear aligner can be fabricated on the 3d printed model. 3D printed individual drilling guide enable the clinician to place the dental implant on the proper position. The development of layer additive technology enhance the quality of 3d printing object and shorten the operating time of 3D printing. In the near future, traditional dental laboratory process such as casting, denture curing will be replaced by digital 3D printing.