• 제목/요약/키워드: Dentin bonding systems

검색결과 74건 처리시간 0.029초

Influence of application time of self-etching primer on bonding to dentin

  • Song, Ki-Gang;Lee, Young-Gon;Cho, Young-Gon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.625-625
    • /
    • 2003
  • I. Objectives Self-etching primer adhesive system is affected to dentin surface conditioning and priming. Especially application time of self-etching primer is very important factor of clinical procedure which has direct influence on smear layer, etching reaction and primer penetration to dentin. This study evaluated the influence of application time of self-etching primers on microtensile bond strength (${\mu}{\;}TBS$) to dentin using three self-etching primer adhesive systems.(omitted)

  • PDF

전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가 (Shear bond strength of dentin bonding agents cured with a plasma arc curing light)

  • 권영철;김선영;정세준;한영철;이인복;손호현;엄정문;조병훈
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.213-223
    • /
    • 2008
  • 광물리학적 특성 분석을 위해 Apollo 95E (DMT Systems, Orange, CA : PAC 광중합기), Elipar Freelight 2 (3M ESPE, MN, USA; LED 광중합기) 그리고 VIP Junior (Bisco, Schaumberg, IL, USA : QTH 광중합기), 3종의 광중합기의 총광강도(Total intensity)와 spectral distribution을 측정하였고 특정 파장에 해당되는 광강도(Energy density)를 분석하였다. 상아질 전단접착강도의 측정을 위해 Scotchbond Multipurpose (3M ESPE), Single bond (3M ESPE) 그리고 Clearfil SE bond (Kuraray)가 사용되었다. Plasma Arc Curing light (Apollo 95E) 광중합기는 여러개의 최대정점을 가지며 넓은 spectral distribution과 $2307mW/cm^2$의 높은 광강도를 나타내었고, VIP Junior 광중합기는 490 nm에서 최대정점을 갖는 넓은 spectral distribution을 나타내었고, Elipar Freeelight 2 광중합기는 462 nm의 최대정점 주위로 좁은 spectral distribution을 보였다. Two-Way ANOVA와 Bonferroni's multiple comparison test를 이용하여 상아질 전단접착강도를 분석한 결과, PAC 광중합기와 LED 광중합기 간에 유의성 있는 차이를 보이지 않았으며 (P > 0.05), 상아질 접착제와 광중합기의 교호관계에도 유의성이 없었다. 그러나 상아질 접착제는 상호간에 유의성 있는 차이를 보였다 (P < 0.00).

  • PDF

전단접착강도와 관련된 Plasma Arc Curing Light의 중합효율평가 (Shear bond strength of dentin bonding agents cured with a plasma arc curing light)

  • 권영철;김선영;정세준;한영철;이인복;손호현;엄정문;조병훈
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.213-223
    • /
    • 2008
  • 광물리학적 특성 분석을 위해 Apollo 95E (DMT Systems, Orange, CA; PAC 광중합기), Elipar Freelight 2 (3M ESPE, MN, USA; LED 광중합기) 그리고 VIP Junior (Bisco, Schaumberg, IL, USA; QTH 광중합기), 3종의 광중합기의 총광강도(Total intensity)와 spectral distribution을 측정하였고 특정 파장에 해당되는 광강도 (Energy density)를 분석하였다. 상아질 전단접착강도의 측정을 위해 Scotchbond Multipurpose (3M ESPE), Single bond (3M ESPE) 그리고 Clearfil SE bond (Kuraray)가 사용되었다. Plasma Arc Curing light (Apollo 95E) 광중합기는 여러개의 최대정점을 가지며 넓은 spectral distribution과 $2307mw/cm^2$의 높은 광강도를 나타내었고, VIP Junior 광중합기는 490nm에서 최대정점을 갖는 넓은 spectral distribution을 나타내었고, Elipar Freeelight 2 광중합기는 462 nm의 최대정점 주위로 좁은 spectral distribution을 보였다. Two-Way ANOVA와 Bonferroni's multiple comparison test를 이용하여 상아질 전단접착강도를 분석한 결과, PAC 광중합기와 LED 광중합기 간에 유의성 있는 차이를 보이지 않았으며 (P > 0.05), 상아질 접착제와 광중합기의 교호관계에도 유의성이 없었다. 그러나 상아질 접착제는 상호간에 유의성 있는 차이를 보였다 (P < 0.001).

Microtensile bonding of dentin adhesives

  • Song, Yong-Beom;Lee, Se-Joon;Lee, Kwang-Won
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.585.2-585
    • /
    • 2001
  • The purpose of this study was to evaluate the microtensile bond strength of sixth-generation adhesives according to various dentin surface treatments and to observe the interface between resin(Z-100TM) and dentin by SEM. This study employed forty-five non-caries extracted human molars and three adhesive systems were used; All-Bond 2(AB), One-Up Bond F(OU), AQ-Bond(AQ).; group 1, 2, 3 were used AB and were respectively treated by smearing(S), ultrasonic cleansing(US), etching(E).(omitted)

  • PDF

Influence of silver nanoparticles on resin-dentin bond strength durability in a self-etch and an etch-and-rinse adhesive system

  • Jowkar, Zahra;Shafiei, Fereshteh;Asadmanesh, Elham;Koohpeima, Fatemeh
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.13.1-13.9
    • /
    • 2019
  • Objectives: This study evaluated the effect of dentin pretreatment with silver nanoparticles (SNPs) and chlorhexidine (CHX) on the microshear bond strength (${\mu}SBS$) durability of different adhesives to dentin. Materials and Methods: Occlusal surfaces of 120 human molars were ground to expose flat dentin surfaces. The specimens were randomly assigned to six groups (n = 20). Three groups (A, B, and C) were bonded with Adper Single Bond 2 (SB) and the other groups (D, E, and F) were bonded with Clearfil SE Bond (SEB). Dentin was pretreated with CHX in groups B and E, and with SNPs in groups C and F. The specimens were restored with Z250 composite. Half of the bonded surfaces in each group underwent ${\mu}SBS$ testing after 24 hours and the other half was tested after 6 months of water storage. Results: SNP application was associated with a higher ${\mu}SBS$ than was observed in the CHX and control groups for SEB after 24 hours (p < 0.05). A significantly lower ${\mu}SBS$ was observed when no dentin pretreatment was applied compared to dentin pretreatment with CHX and SNPs for SB after 24 hours (p < 0.05). The ${\mu}SBS$ values of the 6-month specimens were significantly lower than those obtained from the 24-hour specimens for all groups (p < 0.05). This decrease was much more pronounced when both adhesives were used without any dentin pretreatment (p < 0.05). Conclusions: SNPs and CHX reduced the degradation of resin-dentin bonds over a 6-month period for both adhesive systems.

상아세관의 주행방향에 따른 상아질 접착제의 침투양상에 대한 공초점레이저주사현미경 연구 (EFFECT OF DENTINAL TUBULES ORIENTATION ON PENETRATION PATTERN OF DENTIN ADHESIVES USING CONFOCAL LASER SCANNING MICROSCOPY)

  • 김동준;황윤찬;김선호;오원만;황인남
    • Restorative Dentistry and Endodontics
    • /
    • 제28권5호
    • /
    • pp.392-401
    • /
    • 2003
  • The purpose of this study was to evaluate the penetration pattern of dentin adhesives according to the orientation of dentinal tubules with confocal laser scanning microscopy. Specimens having perpendicular. parallel and oblique surface to dentinal tubules were fabricated. The primer of dentin adhesives (ALL $BOND^{\circledR}{\;}2,{\;}CLEARFIL^{TM}$ SE BOND and PQ1) was mixed with fluorescent material. rhodamine B isothio-cyanate (Aldrich Cherm. CO., Milw., USA), It was applied to the specimens according to the instructions of manufactures. The specimens were covered with composite resin (Estelite, shade A2) and then cut to a thickness of 500$\mu\textrm{m}$ with low speed saw (Isomet^{TM}, Buehler. USA). The adhesive pattern of dentin adhesives were observed by fluorescence image using confocal laser scanning microscopy. The results were as follows. 1. For the groups with tubules perpendicular to bonded surface. funnel shape of resin tag was observed in all specimen. However. resin tags were more prominent in phosphoric acid etching system (ALL $BOND^{\circledR}$ 2 and PQ1) than self etching system ($CLEARFIL^{TM}$ SE BOND). 2. For the groups with tubules parallel to bonded surface. rhodamine-labeled primer penetrated into peritubular dentin parallel to the orientation of dentinal tubules. But rhodamine-labeled primer of PQ1 diffused more radially into surrounding intertubular dentin than other dentin adhesive systems. 3. For the groups with tubules oblique to bonded surface. resin tags appeared irregular and discontinuous. But they penetrated deeper into dentinal tubules than other groups.

유치와 영구치에서 치과용 접착제의 전단결합강도 (THE SHEAR BOND STRENGTH OF DENTAL ADHESIVES ON PRIMARY AND PERMANENT TEETH)

  • 최진영;최남기;박영준;최충호;양규호
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.579-589
    • /
    • 2007
  • 본 연구에서는 최근에 개발된 치과용 접착제를 대상으로 유치와 영구치의 법랑질과 상아질에 대한 결합력을 비교 평가하여 임상에서 상아질 접착제를 적절하게 선택하는데 도움을 주고자 시행하였다. 실험재료로 Adper Scotchbond Multi-purpose Plus Adhesive (SM; 3M ESPE, USA), Adper Single bond 2 (SB; 3M ESPE, USA), Clearfil SE Bond (SE; Kuraray Medical Inc., Japan), Adper Prompt L-Pop (PL; 3M ESPE, USA), G-Bond (GB; GC Cooperation Toyko, Japan)를 이용하여 전단결합강도를 평가하여 다음과 같은 결과를 얻었다. 1. 유치 법랑질에서 전단결합강도는 SM이 $28.47{\pm}7.93\;MPa$로 가장 높았고 SB ($28.18{\pm}6.84$), PL ($24.02{\pm}6.14$), SE ($21.70{\pm}6.56$), GB ($17.70{\pm}6.68$) 순이었다. SM과 SB는 SE보다 통계적으로 유의하게 높은 결합강도를 보였으며, SM, SB, PL은 GB보다 높았다(p<0.05). 2. 유치 상아질에서 전단결합강도는 SE가 $28.72{\pm}14.44MPa$로 가장 높았고, PL ($20.10{\pm}6.13$), SM ($17.72{\pm}10.65$), SB ($15.48{\pm}2.66$), GB ($10.10{\pm}5.45$) 순이었으며 SE와 GB간에는 유의한 차이가 있었으나, 다른 군들 간에는 유의한 차이가 없었다. 3. 영구치 법랑질에서의 전단결합강도는 SB가 $28.36{\pm}5.68\;MPa$로 가장 높았고 SM ($22.77{\pm}4.63$), PL ($22.05{\pm}6.57$), SE ($21.74{\pm}4.62$), GB ($15.60{\pm}6.75$)순이었다. SB는 다른 접착제보다 통계적으로 유의하게 높은 결합력을 나타냈으며, GB는 가장 낮은 결합력을 보였다(p<0.05). 4. 영구치 상아질에서의 전단결합강도는 SM이 $28.22{\pm}5.56\;MPa$로 가장 높았고, SB ($21.68{\pm}7.44$), SE ($20.13{\pm}9.88$), GB ($14.30{\pm}6.81$), PL ($14.18{\pm}5.88$)순이었으며, SM은 PL, GB와 유의한 차이가 있었다(p<0.05). 5. 유치의 법랑질과 상아질 간에는 SM, SB, GB에서 유의한 차이가 있었고, 영구치 법랑질과 상아질 간에는 PL에서 유의한 차이가 있었다(p<0.05). 6. 유치 법랑질과 영구치 법랑질 간에는 모든 접착제에서 유의한 차이가 없었으나, 유치 상아질과 영구치 상아질 간에는 SM과 SB에서 유의한 차이가 있었다(p<0.05).

  • PDF

$Carisolv^{TM}$ 에 의한 우식제거후 Microtensile Bonding Strength에 관한 연구 (AN EXPERIMENTAL STUDY ON THE MICROTENSILE BONDING STRENGTH OF DENTIN TREATED BY $CARISOLV^{TM}$)

  • 백병주;권병우;김재곤;전철완
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.389-396
    • /
    • 2002
  • 이 연구의 목적은 전형적인 우식제거(bur)와 기계화학적으로 제거된 상아질($Carisolv^{TM}$)의 microtensile bonding strength를 비교하는 것이다. 다음과 같은 결합 system이 사용되었다; AB: All Bond 2(3M, USA), PB: Prime & Bond 2.1(Dentsply, DE), AQ: AQ Bond(sun medical, Japan). 교합면 우식증을 가지고 있는 42개의 사람 대구치를 6개 그룹으로 나누었다. 각각의 그룹은 다음과 같이 나누었다; $Carisolv^{TM}$를 적용한 그룹 A, B, C와 bur를 사용한 그룹 D, E, F, A와 D 그룹에서는 AB가 상아질 결합제로 사용하였고, 그룹 B, E는 PB를 그룹 C, F는 AQ를 사용하였다. 그 후 와동은 복합레진(Z-100)으로 충전하였다. 각각의 시편을 0.7 mm 두께로 자르고 0.7 mm의 넓이로 다시 잘랐다. Microtensile bonding strength test는 $0.5\;mm/min^{-1}$의 crosshead에서 시행하여 파절면을 scanning electron microscope(JSM-6400, Jeol, Japan)로 관찰하여 다음과 같은 결과를 얻었다. 1. $Carisolv^{TM}$로 우식을 제거했을 때 Microtensile bonding strength는 bur를 사용한 것에 비해서 75.8-80%로 감소하였다(p<0.05). 2. $Carisolv^{TM}$로 우식을 제거했을 때 Microtensile bonding strength가 감소된 정도는 상아질 결합제의 종류에 따라 각 군별로 차이가 없었다(p<0.05). 3. $Carisolv^{TM}$로 우식을 제거했을 때 All bonds는 32.6 MPa, Prime & bond는 30.1 Mpa, AQ bond는 21.2 Mpa이었다. 4. Bur와 $Carisolv^{TM}$로 우식제거시 AQ bond는 All bond와 Prime & bond 2.1보다 유의하게 낮은 결합강도를 가졌다(p<0.01).

  • PDF

Chlorhexidine 처리가 상아질 접착제의 미세인장결합강도에 미치는 영향 (EFFECT OF CHLORHEXIDINE ON MICROTENSILE BOND STRENGTH OF DENTIN BONDING SYSTEMS)

  • 오은화;최경규;김종률;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제33권2호
    • /
    • pp.148-161
    • /
    • 2008
  • 본 연구는 상아질 혼성층의 교원섬유를 가수분해하는 효소인 MMPs (Matrix metalloproteinses)의 억제제로 알려진 chlorhexidine (CHX)을 적용 후 결합강도를 측정하였으며, 이를 각각 열순환 처리 후 결합강도를 측정하였다. 또한 주사전자현미경으로 접착계면에서의 파괴 양상을 비교 분석하였다. 우식이 없는 발거한 32개의 제3대구치의 교합면 상아질을 노출시키고 GI그룹에서는 dentin conditioner를 처리 후 2% chlorhexidine을 적용시키고, 산부식 접착제 그룹에서는 인산 산부식을 시행하고 2% chlorhexidine을 적용 후 3단계 산부식형 상아질 접착제 (Scotchbond Multipurpose, SM), 2단계 산부식형 상아질 접착제 (Single Bond, SB)를 도포하고, 자가부식 접착제 그룹에서는 2% chlorhexidine 적용 후 자가부식 상아질 접착제 (Clearfil Tri-S, TS)를 도포한다. 이후 복합 레진 (Z-250)과 GI (Fuji-II LC)를 충전한 시편을 $1\;mm^2$의 단면을 갖는 beam으로 제작하여 열순환 하지 않거나, 10,000회 열순환 ($5\;{\sim}\;55^{\circ}C$)하였다. Universal testing machine (EZ-test; Shimadzu, Japan)에서 cross head speed 1 mm/min로 인장력을 가하여, 미세인장결합강도를 측정하였다. 실험 결과는 유의수준 0.05 level에서 two-way ANOVA를 이용하여 통계분석하였다. 그 후 파절된 시편의 파괴 양상을 현미경 (SEM)으로 관찰하여 다음과 같은 결론을 얻었다; 1. 2% CHX을 적용한 모든 실험군에서 상아질과의 미세인장결합강도가 증가하였고, 열순환은 상아질과의 미세인장결합강도를 감소시켰다 (P > 0.05). 2. CHX 적용 후 열순환 한 군은 CHX을 적용하지 않고 열순환한 군에 비하여 상아질과의 미세인장결합강도가 높았으며, 특히 GI와 TS군에서 유의한 차이를 나타내었다 (P < 0.05). 3. 파괴 양상 분석 결과, 혼성층에서의 접착성 파괴를 보이며, CHX을 적용하면 혼성층 기저부에서 상부로 파괴 부위가 옮겨가는 양상을 나타내었다. 이상의 연구 결과를 토대로, MMPs 억제제인 2% CHX은 글래스 아이오노머 시멘트와 상아질 접착제의 초기 미세인장결합강도에는 영향을 미치지 않으며, CHX 적용이 접착내구성을 유지하는데 도움이 되었다.

열순환이 상아질 접착제의 결합 내구성에 미치는 영향 (THE EFFECT OF THERMOCYCLING ON THE DURABILITY OF DENTIN ADHESIVE SYSTEMS)

  • 문영훈;김종률;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제32권3호
    • /
    • pp.222-235
    • /
    • 2007
  • 이 논문의 목적은 열순환이 4종 상아질 접착 시스템의 결합 내구성에 미치는 영향을 측정한 것이다. 제3대구치의 상아질층을 노출시킨 후, 무작위로 8개군으로 나눈다: 3단계 산부식 시스템 (Scotchbond Multi-Purpose Plus; SM, All Bond-2 ; AB), 2 단계 산부식 시스템 (Single Bond; SB, One Step plus, OS), 2단계 자가부식 시스템 (Clearfil SE Bond; SE, AdheSE; AD), 1 단계 자가부식 시스템 (Promp L-Pop ; PL, Xeno III; XE). 8개 군에 각 상아질 접착제를 제조사의 지시에 따라 도포하고 복합레진 (Z250)을 적층한 후, 광조사한다. $37^{\circ}C$ 증류수에서 24시간 보관한 후, 각 군마다 정해진 프로그램으로 0, 1000, 2000회 열순환한 후, 저속 diamond saw로 $1\times1mm$ 막대형 시편을 제작한다. Universal testing machine (EZ-test; Shimadzu, Japan)으로 미세인장 결합강도를 측정하였고, 유의수준 0.05 level에서 ANOVA / Duncan's test로 통계분석 하였다. 상아질측 파단면과 접착계면에 대한 주사전자현미경 관찰을 시행하였다. 이 연구의 결과는 다음과 같다; 1. 3단계 상아질 접착제의 결합강도는 열순환 전후에 통계학적으로 유의한 변화를 나타내지 않았다. 2단계 산부식형 상아질 접착제의 결합강도는 열순환 처리에 의하여 유의하게 감소되었다. 2. 2단계 자가부식형 접착제 (SE)의 결합강도가 가장 높았고, 1단계 자가부식 접착제 (PL, XE)는 실험군 중 가장 낮은 결합강도를 보였다. 3. 모든 접착제는 주로 접착성 파괴가 발생하였고, 열순환에 의하여 산부식형 접착제는 접착성 파괴가, 1단계 자가부식형 접착제에서는 혼합형 파괴가 증가하는 경향을 나타내었다. 이상의 결과로, 상아질 접착제의 접착단계/과정이 결합내구성에 영향을 미침을 알 수 있었다. 따라서 접착과정의 단순화가 반드시 접착에 효과적이라고 할 수 없다.