치경부 5급 와동 수복의 잇솔질 마모에 관한 연구 (A Study on the Toothbrush-Dentifrice Abrasion of Class V Restroations)

  • 황수진;유미경;이광원
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.69-81
    • /
    • 2005
  • The objective of this study was to evaluate the toothbrush abrasion characteristics of class V restorations. Thirty extracted human premolars, which were collected from oral surgery clinics were used. We mounted five teeth in a metal ring mold of 50 mm in diameter and 15 mm in height using chemically cured acrylic resin. Class V cavities were prepared in lingual cervical root surfaces and restored using one of following restorative materials : Dentin Conditioner/Fuji II LC (Group FL), All Bond II/Z-250 (Group ZT), One-up Bond F/Palfigue Estelite (Group PE), F2000 Primer/Adhesive (Group FT), and Prime & Bond 2.1/Dyract AP (Group DR). They were stored under distilled water at $37^{\circ}C$ for seven days. The toothbrush abrasion test was conducted using a wear testing machine of pin-on disk type under a load of 1.5 N for 100,000 cycles. We have examined the bonded interfaces, the changes of surface roughness and color of abraded surfaces. From this experiment, the following results were obtained. 1. The change of surface roughness showed high degree: RMGIC>compomer>composite resin (p<0.05). 2. Because of the protrusion and missing of filler particles, SEM observation of abraded surfaces of RMGIC and compomers revealed the increase of surface roughness due to the selective removal of matrix resin. 3. The color change by toothbrush abrasion was affected in large part by the change of $L^*$ and $b^*$ of resin composites (p<0.05). 4. The color change by toothbrush abrasion was so small to detect by human eyes. 5. SEM observation of abraded surfaces revealed the interface bonding was the best in the FT group.

Die spacer의 두께에 따른 복합레진 inlay의 치은 변연부 미세누출 및 접착양태에 관한 연구 (GINGIVAL MARGIAL LEAKAGE AND BONDING PATTERN OF THE COMPOSITE RESIN INLAY ACCORDING TO VARIOUS THICKNESS OF DIE SPACER)

  • 박태일;신동훈;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제20권1호
    • /
    • pp.152-163
    • /
    • 1995
  • This experiment was performed to observe the adhesion pattern and microleakage in the gingival margin according to variation in the resin cement thickness which results from thickness of Die spacer. which is considered to effect the adaptability of the composite resin inlays. Clearfil CR inlays were fabricated on stone models with CR Sep applicated once and Nice fit twice, 4 times, and 6 times each. After 2nd curing within the CRC-100 oven, CR inlays were cemented with CR inlay cement. Dye(2% methylene blue) penetration and adhesion pattern were evaluated after sectioning of gingival margin into :3 pieces. The results were as follows ; 1. The thickness of resin cement showed unevenchanging pattern with that of die spacer, namely, it was increased until 4 times' application of Nice-Fit but was decreased with 6 times' application of that. 2. The degree of dye penetration wasn't affected by cement thickness within a limited value. 3. Most of dye penetration was shown through the interface between cement and enamel rather than the interface between cement and CR inlay. This shows that the affinity of resin cement for CR inlay was superior to the adhesive strength with tooth structure. 4. No gap was found at the interface between enamel and cement but some showed separation between dentin and cement. It is concidered that the contraction force of cement was less than the bond strength with the enamel. 5. Lots of voids were found in the CR inlay and resin cement. There was a pooling tendency of bonding agent and cement in the axiogingival line angle portion. 6. In some specimens, cracks were shown in enamel margin. From this it could be considered that cavity preparation and surface treatment weakened the tooth structure.

  • PDF

치아표면 거칠기와 시멘트 종류가 전부주조관의 유지력에 미치는 영향 (INFLUENCE OF TOOTH SURFACE ROUGHNESS AND TYPE OF CEMENT ON RETENTION OF COMPLETE CAST CROWNS)

  • 김길수;송창용;안승근;박찬운
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.465-473
    • /
    • 1999
  • Bond strength of luting cements to dentin is a critical consideration for success of complete cast crowns. This study was performed to evaluate the relationship between surface characteristics of teeth prepared for complete cast crowns and retention of cemented restorations. Eighty artificial crowns were cast for standardized complete crown tooth preparations accomplished with the use of a special device on recently extracted human teeth. Coarse diamond(#102R, Shofu) and superfine finishing diamond(#SF102R, Shofu) burs of similar shape were used. Crowns in each group were randomly subdivided into few subgroups of 10 for luting cements selected for this study: zinc phosphate cement (FLECK' S), polycarboxylate cement (Poly-F), rein-forced glass ionomer cement (Fuji PLUS). and adhesive resin cement (Panavia 21). Retention was evaluated by measuring the tensile load required to dislodge the artificial crown from tooth preparations with an Instron testing machine, and analysed by one-way ANOVA and Student's t-test. The obtained results were as follows ; 1. When tooth preparation was done with coarse diamond bur, retentive force was diminished in order of Panavia 21 Fuji PLUS, FLECK'S, and Poly-F. Retentive forces showed the significant difference between Fuji PLUS group and FLECK'S group(p<0.001). 2. When tooth preparation was done with superfine diamond bur, retentive force was diminished in order of Fuji PLUS, Panavia 21, FLECK'S, and Poly-F. Retentive forces showed the significant difference between Panavia 21 group and FLECK'S group(p<0.001). 3. Retentive force in coarse tooth surfaces was significantly higher than that in superfine tooth surface with all luting cements(p<0.001), and cement residues were almost retained with-in the cast crown in all groups.

  • PDF

치아/복합레진 수복부의 중합 수축시 검출된 음향방출의 통계적 검증 (Statistical Verification of Acoustic Emissions Detected during Polymerization Shrinkage of Resin Restoration in Dental Ring)

  • 구자욱;최낙삼
    • Composites Research
    • /
    • 제23권6호
    • /
    • pp.39-46
    • /
    • 2010
  • 치아의 와동에 수복된 치과용 복합레진을 광(LED) 조사를 통해 정화 수축시키면서 음향방출(acoustic emission, AE) 신호를 검출하였다. 비모수 통계법인 Mann-Whitney법과 Kruskal-Wallis법을 이용하여 시편의 재질과 계면의 접착조건에 따른 AE hit event 수와 최대진폭을 비교 평가하였다. PMMA와 치아시편으로부터 검출된 선호의 최대진폭은 정착조건에 따른 차이가 없었지만 스테인리스 시편으로부터 검출된 신호는 접착조건에 따라 최대 진폭의 차이가 있었다(p<0.05). AE hit event 수는 양호한 접착조건에서 시편의 재질에 따라 차이가 있었고(p<0.05), 세가지 재질의 시편 모두 접착조건이 양호한 실험에서 AE 신호가 적게 검출되었다. SEM을 이용하여 계면에 생성된 캡을 측정한 결과 AE가 많이 검출되고 검출된 신호의 최대 진폭이 큰 시편에서 갱의 폭이 넓고 형성 비율이 높았다.

치아 와동의 복합레진 수복시 음향방출의 시간적 발생 특성 (Time-Based Characteristics of Acoustic Emission During Dental Composite Restoration)

  • 구자국;최낙삼
    • 대한기계학회논문집A
    • /
    • 제35권2호
    • /
    • pp.169-174
    • /
    • 2011
  • 제 1 급 와동이 모사된 비관통형 치아 시편에 수복된 복합레진의 중합 수축시 발생하는 AE 신호를 실시간으로 검출한 후 이를 분석하였다. 시간대별 발생 분포를 살펴보면, 광조사 초기에 중합 수축이 급격히 진행되는 제 I 구간에서 AE event 가 많이 관찰되었다. 제 I구간 후 AE event 발생 빈도가 낮아져 AE 가 별로 관찰되지 않은 제II구간이 있었는데, AE 신호의 발생이 적은 PMMA 는 치아에 비해 구간이 길었으며 AE 검출이 잦았던 스테인리스스틸 모형은 제 II 구간이 짧았다. AE 활성도를 나타내는 구간 특성은 수복재와 와동의 계면부에서 일어나는 균열의 발생빈도를 나타내는 것으로 사료되며 젤화점 직후의 제I 구간에서 AE 가 집중적으로 관측되는 바, 수복재와 와동 사이의 갭 형성은 바로 젤화점 직후에 만들어졌음을 가리킨다. 신호의 최대 진폭은 25-45dB 이었고 1 차 중심 주파수는 100-200kHz 와 240-400kHz 영역의 신호들이 발생하였으며 이는 레진이나 접착층의 파괴에 해당하였다.

인산농도에 따른 치질의 미세누출 효과 (EFFECT OF CONCENTRATION OF PHOSPHORIC ACID ON MICROLEAKAGE TO TOOTH STRUCTURE)

  • 김병태;조영곤;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.559-568
    • /
    • 1996
  • The purpose of this study was to evaluate the micro leakage of composite resin when various phosphoric acid agents were used to etch the enamel and dentin. In this study, class V cavities were prepared on the buccal surfaces of fourty extracted human molar teeth, and they were randomly assigned into 4 groups with 10 teeth. The cavities of each groups were etched with 10%, 32%, 35% and 37% phosphoric acids for 15 seconds, washed and dried and the cavities were restored with composite resin after application of the adhesive. The specimens were immersed in 2% methylene blue solution for 3 days. And then, the specimens were sectioned buccoligually. Degree of dye penetration at tooth-restoration interfaces was examined by Inverted Metallurgical Microscope at the occlusal and gingival margins. The result were as follows : 1. The degree of microleakage at occlusal and gingival margin in all group was statistically difference among 10% and 35% (P<0.01), 10% and 37% (P<0.01), 32% and 35% (P<0.05) and 32% and 37% (P<0.05) acid concentrations, but was not statistically difference between 10% and 32%, 35% and 37% acid concentrations (P>0.05). The degree of microleakage was showed to dimish with increase of acid concentration. 2. The degree of microleakage at the occlusal margin was statistically significant difference among 10% and 32%,10% and 35%, 10% and 37% acid concentrations(P<0.05). The degree of microleakage among 32% and 35%, 32% and 37% and 32% and 37% acid concentrations was not statistically significant difference. 3. In comparison of microleakage at the gingival margin, the degree of microleakage above 32% acid concentration was not showed less than 10% acid concentration (P>0.05). In comparison of 32%, 35%, 37% acid concentrations, the degree of microleakage at 35% and 37% acid concentrations was showed less than 32% acid concentration(P<0.05).

  • PDF

음향방출법을 이용한 치아/복합레진 수복재의 계면부 파괴해석 (Interfacial fracture analysis of human tooth/composite resin restoration using acoustic emission)

  • 구자욱;최낙삼
    • Composites Research
    • /
    • 제22권6호
    • /
    • pp.45-51
    • /
    • 2009
  • 치아의 와동에 수복된 치과용 복합레진을 광(LED) 조사를 통해 경화 수축시키면서 음향방출(acoustic emission, AE)법을 이용하여 와동 벽면과 복합레진 사이의 계면상태를 실시간 해석하였다. 복합레진의 중합 수축에 의해 AE 신호들이 검출되었는데 계면 접착 상태가 나쁜 경우, 경화 수축률이 큰 초기 1분 동안 많은 AE 사상들이 관측되었으며, 이들 AE는 주파수범위가 주로 100-200kHz인 돌발형이었다. 인간치아 재질의 시편에서 발생된 AE 사상수는 스테인리스 스틸 시편보다 적었으나, PMMA 시편보다는 많았고 접착제의 도포 상태가 양호할수록 검출되는 AE 사상수는 적었다. AE 파라미터의 특성은 복합레진과 링재 사이의 접착부에서 발생하는 인장형 균열전파 및 복합레진의 수축에 따른 링재의 압축거동과 관련되었으며, 음향방출법이 치아 수복물의 접착성에 대한 비파괴 검사법으로써 유효함을 알았다.

Comparative evaluation of Emblica officinalis as an etchant and an MMP inhibitor with orthophosphoric acid and chlorhexidine on the microshear bond strength of composite resin: an ex vivo study

  • Divya Sangeetha Rajkumar;Annapoorna Ballagere Mariswamy
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.36.1-36.11
    • /
    • 2021
  • Objectives: This study aimed to evaluate Emblica officinalis (Indian gooseberry or amla) as an acid etchant and matrix metalloproteinase (MMP) inhibitor, and to compare its effect on the microshear bond strength of composite resin with orthophosphoric acid (OPA) and 2% chlorhexidine (CHX) as an acid etchant and MMP inhibitor, respectively. Materials and Methods: The etching effect and MMP-inhibiting action of amla on dentin samples were confirmed by scanning electron microscopy (SEM) and gelatin zymography, respectively. Dentinal slabs (3 mm thick) from 80 extracted human molars were divided into 10 and 20 samples to form 2 control groups and 3 experimental groups. Groups 1, 2, and 4 were etched with OPA and groups 3 and 5 with amla juice. An MMP inhibitor was then applied: CHX for group 2 and amla extract for groups 4 and 5. Groups 1 and 3 received no MMP inhibitor. All specimens received a standardized bonding protocol and composite resin build-up, and were subjected to microshear bond strength testing. The force at which the fracture occurred was recorded and statistically analyzed. Results: Amla juice had a similar etching effect as a self-etch adhesive in SEM and 100% amla extract was found to inhibit MMP-9 by gelatin zymography. The microshear bond strength values of amla were lower than those obtained for OPA and CHX, but the difference was not statistically significant. Conclusions: Amla has a promising role as an acid etchant and MMP inhibitor, but further studies are necessary to substantiate its efficacy.

Comparison of Shear Bond Strength in Novel Calcium Silicate-Based Materials to Composite Resin

  • Wonkyu Shin;Hyuntae Kim;Ji-Soo Song;Teo Jeon Shin;Young-Jae Kim;Jung-Wook Kim;Ki-Taeg Jang;Hong-Keun Hyun
    • 대한소아치과학회지
    • /
    • 제50권4호
    • /
    • pp.443-451
    • /
    • 2023
  • The purpose of this study was to evaluate whether the newly introduced calcium silicate-based materials with fast-setting properties could be appropriately used as basement materials in indirect pulp treatment (IPT). This was performed by quantifying the durability of adhesion between the material and composite resin, measured by the shear bond strength (SBS). Five calcium silicate-based materials, TheraCal LC® (TLC), TheraCal PT® (TPT), TheraBase® (TB), Well-RootTM PT (WPT), and Endocem® MTA (EMTA), as well as two glass ionomer-based materials, Fuji II and Fuji II LC, were included. Specimens containing these materials were manufactured and bonded to composite resin with a universal adhesive applied in self-etch mode. The SBS values and failure modes were recorded, and the mean SBSs of the materials were compared. Both TPT and TB exhibited SBS values that were similar to TLC, while both WPT and EMTA appeared to have statistically lower SBS values. Mixed failure was commonly observed in TLC and TPT, while all WPT and EMTA samples showed cohesive failure. In comparison with TLC and TPT, more samples with cohesive failure were observed in TB, implying that this material forms a stronger bond with composite resin. Together with the ability of TB to chemically bind to dentin due to its 10-methacryloyloxydecyl dihydrogen phosphate component, TB seems to be a promising material for IPT within the limitations of this in vitro study.

Ethanol Wet Bonding에서 NaOCl과 EDTA가 결합강도에 미치는 영향 (Influence of Sodium Hypochorite & EDTA on the Microtensile Bond Strength of Ethanol Wet Bonding)

  • 김덕중;송용범;박상희;김형선;이혜윤;유미경;이광원
    • 구강회복응용과학지
    • /
    • 제29권1호
    • /
    • pp.37-44
    • /
    • 2013
  • 근관치료 후 적절한 치관부 밀폐를 위해 레진을 이용한 코어수복방법이 현재 많이 사용되고 있다. 하지만, 근관치료 과정에서 사용되는 NaOCl이나 EDTA같은 근관세척제는 레진 접착에 영향을 주는 것으로 알려져 있으며, 이에 관한 많은 연구들이 이루어져 왔다. 본 연구에서는 ethanol wet bonding을 치수강 상아질에 적용 시에 NaOCl과 EDTA가 결합강도에 미치는 영향에 대해 조사하였다. 30개의 인간 대구치로부터 총 60개의 시편을 얻었고, 이를 무작위로 4개의 군으로 분류했다. G1: 증류수로 세척후 증류수로 마무리 세척, G2: NaOCl로 세척 후 NaOCl로 마무리세척, G3: NaOCl로 세척 후 EDTA로 마무리세척, G4: NaOCl로 세척 후 EDTA로 마무리세척하고 접착과정에서 산부식과정 생략. 접착과정은 인산부식 후 에탄올의 농도를 50%, 70%, 80%, 95% 그리고 100%로 순차적으로 증가시켜가면서 상아질을 탈수시키고 에탄올에 적셔지도록 하였다. 프라이머는 HEMA가 포함되지 않은 상용화된 접착제인 ALL-BOND 3 RESIN과 에탄올을 반반씩 섞어 만들었다. 프라이머 적용 후 ALL-BOND 3 RESIN을 접착제로 사용하였다. 저점도 복합레진을 이용하여 6mm 두께로 적층충전한 후 빔 형태로 잘라 미세인장결합강도 실험을 하였다. NaOCl 처리한 그룹은 미세인장결합강도에 통계적으로 유의한 차이를 보여주지는 않았지만 낮은 평균값을 보여주었다(p=0.052). NaOCl 처리 후 1분간 EDTA로 처리한 그룹은 다른 그룹보다 유의하게 높은 결합강도를 보여주었다(p<0.05). EDTA 처리가 결합강도를 향상 시켰지만, 산부식 과정을 생략할 경우 유의하게 낮은 결합 강도를 보여주었으며, 이는 EDTA처리가 산부식 과정을 대신할 수는 없다는 것을 보여준다.