• 제목/요약/키워드: Dentin Adhesive

검색결과 299건 처리시간 0.033초

광중합 복합레진 수복시 여러 광조사 방법에 따른 미세변연누출에 관한 연구 (MICROLEAKAGE OF CL V COMPOSITE RESTORATIONS USING VARIOUS LIGHT CURING METHODS)

  • 양철영;유현미;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제25권2호
    • /
    • pp.299-308
    • /
    • 2000
  • The purpose of this in vitro study was to evaluate the microleakage of 5 curing methods in class V composite restorations which are composed of two-step light curing, pulse-delay cure, low curing-light intensity, moderate curing-light intensity and high curing-light intensity. In this study, class V cavities were prepared on buccal and lingual surfaces of 50 extracted human upper or lower molars on cementum margin. Single Bond adhesive and Z-100 shade A2 were applied for each group following the manufacture's instruction. The experimental teeth were randomly divided into 5 groups of 10 samples (20 surfaces) each. Group 1: two-step light curing; Group 2: pulse-delay cure; Group 3: low curing-light intensity; Group 4: moderate curing-light intensity; Group 5: high curing-light intensity. After 500 thermocycling between $5^{\circ}C$ and $55^{\circ}C$, the 60 teeth were placed in 2% methylene blue dye for 24 hours, then rinsed with tab water. The specimens were embedded in clear resin, then sectioned buccolingually through the center of restoration with a low speed diamond saw. The dye penetration on each of the specimen was then observed with a stereomicroscope at ${\times}20$. The composite resin/tooth interfaces were examined under Scanning Electron Microscopy. The results were statistically analyzed using the Kruskal-Wallis One Way ANOVA and Dunn's Method. The results of this study were as follows. 1. In all groups, the leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. No group in this study showed significant differences in leakage values at both the enamel and the dentin margins(P<0.05). 3. In all groups, the gaps seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 4. The gaps in this study showed significant differences and two-step light-curing and low curing-light intensity produced significant less gap than high curing-light intensity(P<0.05).

  • PDF

다양한 접착시스템을 이용하여 섬유 강화형 포스트로 수복한 치아에서의 미세누출에 관한 연구 (In vitro study of microleakage of endodontically treated teeth restored with different adhesive systems and fiber-reinforced posts)

  • 박준호;최유성
    • 대한치과보철학회지
    • /
    • 제52권2호
    • /
    • pp.74-81
    • /
    • 2014
  • 연구 목적: 포스트로 수복한 치아의 미세누출을 방지하기 위한 다양한 술식이 개발되고 있고 이에 본 연구에서는 다양한 접착시스템을 이용하여 섬유 강화형 포스트로 수복한 치아에서의 치근부 미세누출에 대해 비교 연구하고자 하였다. 연구 재료 및 방법: 36개의 근관치료된 상악 영구 중절치를 3가지 포스트 그룹으로 분류하였다: Zirconia-glass fiber, Quarze-glass fiber, Polyethylene fiber 포스트. 포스트 공간이 형성되었고 각 포스트는 세가지 접착시스템으로 접착되었다: 3-stage total-etch adhesive, 2-stage total-etch adhesive, 1-stage self-etch adhesive. 각 시편들을 2% 메틸렌 블루 용액에 1주일 동안 담구었다. 세척한 시편을 자가중합 아크릴릭 레진에 포매하였다. 각 시편을 치근단, 중앙, 치관 부위로 수평 절단하였다. 메틸렌 블루가 침투된 각 시편의 절단부를 교합면 측에서 stereomicroscope로 측정하였다. 시료 침투량은 메틸렌 블루 침투 표면과 총 상아질 표면의 비율로 평가하였다. 결과: 모든 절단부위에서 모든 군들은 미세 누출을 보였다. 각 절단 부위별로 접착 시스템에 따른 포스트간의 비교에서는 유의한 차이는 없었다. All Bond 2로 접착한 3단계 접착시스템으로 처리한 치아 중앙절편에서 zirconia-glass fiber와 quarze-glass fiber 포스트 간, zirconia-glass fiber와 polyethylene fiber 포스트 간, quarze-glass fiber와 polyethylene fiber 포스트 간에 미세누출에는 유의한 차이가 있었다(P<.05). 각각의 포스트의 치근단과 치관 부위 사이에는 유의한 차이가 있었고, quarze-glass fiber와 polyethylene fiber 포스트에서 치근단과 중앙 부위 사이에 유의한 차이가 있었다(P<.05). 결론: 포스트 종류에 따른 접착 시스템 간에 미세누출의 유의한 차이가 없었다. 각 절단 부위별로 접착 시스템에 따른 포스트간의 비교에서는 유의한 차이는 없었으나, 유일하게 3단계 접착시스템으로 처리한 포스트의 중앙절편에서 zirconia-glass fiber가 다른 포스트에 비해 유의하게 적은 미세누출을 보였다.

Acidic primer를 이용한 교정용 브라켓 접착의 전단결합강도 (APPLICATION OF ACIDIC PRIMER FOR ORTHODONTIC ADHESIVE SYSTEM)

  • 김진희;진훈희;오장균
    • 대한치과교정학회지
    • /
    • 제31권1호
    • /
    • pp.137-147
    • /
    • 2001
  • Acidic primer는 하나의 용액으로 conditioning과 priming을 동시에 시행하는 새로운 접착 시스템으로 치질의 손상이 적고 처리 과정이 간단한 특징을 지닌다. 본 실험은 acidic primer를 이용하여 치면처리를 시행한 후 기존의 접착제로 브라켓을 접착할 때 적절한 결합강도를 지니는지 평가하기 위하여 고안되었다. 50개의 사람 소구치를 5개군으로 나누어 4개군은 acidic primer로 법랑질을 처리한 후 Clearfil Liner bond $2^{\circledR}$(1군), Transbond $XT^{\circledR}$(2군), Panavla $21^{\circledR}$(3군), Fuji Ortho $LC^{\circledR}$(4군)로 브라켓을 접착하였고 1개군은 TransHond $XT^{\circledR}$를 통상적인 산부식 방법을 이용하여 접착(5군)한 후 전단 결합 강도를 측정하고 접착파절의 양상을 평가하여 다음과 같은 결론을 얻었다. 1 Acidic primer로 처리한 4개의 군 가운데 광중합형 글래스 아이오노머를 사용한 군(4군)의 전단결합강도($9.72{\pm}3.16MPa$)와 Panavia $21^{\circledR}$을 사용한 군(3군)의 전단 결합 강도($8.69{\pm}2.72MPa$)는 37$\%$ 인산으로 처리한 후 광중합형 레진 (Transbond $XT^{\circledR}$)을 사용한 군(5군)의 전단결합강도($10.48{\pm}2.60MPa$)와 유의성있는 차이를 보이지 않았다 (P>0.05). 2. Acidic primer로 처리한 4개의 군 가운데 광중합형 글래스 아이오노머를 사용한 군(4군)과 Panavia $21^{\circledR}$을 사용한 군(3군)의 전단 결합 강도는 Clearfil Liner bond $2^{\circledR}$를 사용한 군(1군)의 전단 결합 강도($1.09{\pm}0.53MPa$)와 광중합형 레진(Transbond $XT^{\circledR}$)을 사용한 군(2군)의 전단 결합 강도($2.70{\pm}1.46MPa$)에 비해 유의하게 큰 강도를 보였다 (p<0.05). 3. 접착제 잔류지수 측정 결과 4군($2.1{\pm}1.1$)과 5군($2.9{\pm}0.3$)의 경우 1군($0.2{\pm}0.4$), 2군($0.3{\pm}0.9$), 3군($0.2{\pm}0.4$)에 비해 접착제 잔류지수가 유의하게 높았다 (p<0.05). 4. 4군과 5군의 접착제 잔류 지수간에는 유의한 차이가 없었다 (p>0.05). 따라서 acidic primer로 치면을 처리하는 방법은 시용되는 접착제에 따라 기존의 산부식 접 착법과 유사한 결합강도를 얻을 수 있어 교정용 브라켓 접착시 산부식 단계를 생략할 수 있는 가능성을 보여준다.

  • PDF

산부식 전처리에 따른 2단계 자가부식 접착제의 연마 법랑질에 대한 미세인장결합강도 (The micro-tensile bond strength of two-step self-etch adhesive to ground enamel with and without prior acid-etching)

  • 김유리;김지환;심준성;김광만;이근우
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.148-156
    • /
    • 2008
  • 자가부식 접착제는 사용하기 쉽고, 술식 민감성이 적은 장점이 있으나 특히 산도가 약한 자가부식 접착제의 법랑질에 대한 결합력은 논란이 되고 있다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond (Kuraray, Okayama, Japan)의 연마 법랑질에 대한 미세인장 결합강도를 측정하여 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose (3M ESPE, St. Paul, MN, USA) 및 1단계 자가부식 접착제인 iBond (Heraeus Kulzer Gmbh, Hanau, Germany)의 결합강도와 비교하고자 하였고, 2단계 자가부식 접착제에 산부식 전처리를 시행하는 것이 법랑질에 대한 결합강도를 높일 수 있는지 알아 보고자 하였다. 실험군은 2단계 자가부식 접착제인 Clearfil SE Bond만 사용한 비산부식 군과 35% 인산 (Scotchbond Etchant, 3M ESPE)으로 산부식 후 Clearfil SE Bond를 사용한 산부식 군, 그리고 1단계 자가부식 접착제인 iBond를 사용한 군으로 나누었다. 대조군은 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose를 사용한 군으로 정하였다. Bovine 전치의 순면을 십자가형으로 4등분하여 각 군으로 무작위로 배분하였다. 각 치아의 순면을 800-grit 실리콘 카바이드 지로 연마한 후 삭제된 법랑질면에 제조사의 설명서에 따라 각 군의 접착제를 적용하고 Light-Core (Bisco)로 적층 충전하였다. 시편은 $37i{\acute{E}}$, 증류수에 일주일 동안 보관한 후 low speed precicion diamond saw (TOPMENT Metsaw-LS, R&B, Daejeon, Korea)를 이용하여 약 $0.8{\times}0.8mm$ 단면이 되도록 시편을 절단하여 미세시편을 제작하였다. 일주일마다 증류수를 교환하면서 한 달, 세 달 동안 $37i{\acute{E}}$, 증류수에 미세시 편을 보관한 후 각각의 미세인장결합강도를 측정하였다. 미세인장결합강도 (MPa)는 파절 시에 가해진 힘 (N)을 접착면적 ($mm^2$)으로 나누어 계산하였다. 접착계면에서의 파절 양상은 실물현미경 (Microscope-B nocular, Nikon)을 이용하여 분류하였다. 미세인장결합강도에 대한 통계분석은 one-way ANOVA를 이용하여 유의수준 5%에서 검정하였고, 사후감정은 Least Significant Difference 방법을 이용하였다. 중합 후 1개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 모든 접착제 간에 유의한 차이가 없었다. 3개월 뒤 측정된 각각의 접착제의 평균 미세인장결합강도는 유의수준 5%에서 iBond 와 Clearfil SE Bond 비산부식 군과 Scotchbond Multi- Purpose 간에는 각각 유의한 차이가 없었다. 본 연구에서는 2단계 자가부식 접착제인 Clearfil SE Bond의 연마 법랑질에 대한 미세인장결합강도가 3단계 산부식수세 접착제인 Scotchbond Multi-Purpose 와 비교하여 유의한 차이가 없었으며 (P>0.05), 3개월 후의 결과에서 Clearfil SE Bond 비산부식 군의 미세인장결합강도가 Clearfil SE Bond 산부식 군보다 유의하게 낮았다 (P<0.05). 즉 35% 인산으로 산부식 전처리를 시행한결과 Clearfil SE Bond 의 법랑질에 대한 결합강도가 증가하였다.

TARGIS & VECTRIS SYSTEM을 이용한 심미적 수복 (Esthetic Restoration Using Targis & Vectris System)

  • 최현식;황정원;신상완;서규원
    • 대한심미치과학회지
    • /
    • 제7권1호
    • /
    • pp.18-26
    • /
    • 1998
  • The improvement of esthetic dentistry has been accelerated from the development of composite resin and dentin-enamel adhesive since 1980's. The indirect composite resin restorations have more accurate proximal contact point and occlusal form than direct restoration. And the side effect of resin shrinkage is minimal because the amount of composite used in oral cavity is limited in cement space. As a results, marginal leakage, hypersensitivity, secondary caries, and discoloration are significantly diminished. The first generation laboratory composite resin used in indirect resin restoration had been widespread in 1980's and the second generation laboratory composite resins were developed in 1990's. The second generation laboratory composite resins are called Ceramic Polymer. The physical properties of Ceramic Polymer are improved because of high content of inorganic filler, and the esthetics and biocompatibility are better than that of the first generation resin. So the application range using composite resin have been broadened. The purpose of this paper is to introduce Targis & Vectris system that is classified to second generation laboratory composite and to report several cases in which the system was utilized for restoration.

  • PDF

실활치 표백술 후 치관내 수복물의 미세누출에 관한 비교 (THE COMPARISON OF MICROLEAKAGE ON INTRACORONAL RESTORATION AFTER NON-VITAL BLEACHING)

  • 정재은;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.57-63
    • /
    • 2003
  • The purpose of the present study were to evaluate microleakage of a fourth generation dentin-bonding agent following a walking bleaching treatment, to determine the effect of temporary postbleaching dressing with calcium hydroxide on microleakage and to investigate the effect of delayed intracoronal restoration on microleakage. The results of this study were as follows : 1. Bleached groups showed more microleakage than unbleached group 2. Immediately restored group following bleaching procedure showed the highest microleakage score. 3. One-week delayed restorations showed less microleakage but there were no statistically significant difference between group II and III. 4. Provisional dressing with calcium hydroxide had no influence on microleakage. It is necessary to know the time that has elapsed from the bleaching treatment to the restoration procedure to achieve optimal seal, as well as to reduce the risk of microleakage in adhesive restoration.

유치에 적용된 All-in-One 상아질 접착 시스템의 전단강도에 관한 비교연구 (COMPARATIVE STUDY ON THE SHEAR BOND STRENGTH OF ALL-IN-ONE DENTIN BONDING SYSTEM APPLIED TO PRIMARY TEETH)

  • 김동철;김종수;유승훈
    • 대한소아치과학회지
    • /
    • 제34권4호
    • /
    • pp.560-568
    • /
    • 2007
  • 유치 60개를 준비하였으며, 사용된 접착 시스템은 AQ Bond $Plus^{TM}$, G $Bond^{TM}$, Single $Bond^{TM}$였다. 유치의 법랑질과 상아질을 노출시킨 후 제조사의 지시에 따라 접착 레진을 적용한 후, 내경 1.7 mm의 폴리에틸렌 튜브를 이용하여 Z-$250^{TM}$ 복합레진을 수복하였다. 100% 습윤 상태에서 24시간동안 보관 후 $5^{\circ}C$$55^{\circ}C$ 조건하에서 500회 열순환을 시행 후 만능시험기로 전단결합강도를 측정하였다. Resin tag 관찰을 위하여 상아질 접착면에 대해 수직으로 절단하고 인산과 질산으로 처리하여 치질을 용해시킨 후 주사 전자 현미경으로 관찰한 결과 다음과 같은 결론을 얻었다. 1. 유치 법랑질에서 측정된 전단 결합 강도는 AQ Bond $Plus^{TM}$에서 $1.04\;{\pm}\;0.13\;MPa$, G $Bond^{TM}$에서 $1.23\;{\pm}\;0.35\;MPa$, Single $Bond^{TM}$에서 $1.28\;{\pm}\;0.50\;MPa$이었으며, 세 군 간의 유의차는 없었다. 2. 유치 상아질에서의 전단 결합 강도는 AQ Bond $Plus^{TM}$$1.15\;{\pm}\;0.37\;MPa$, G $Bond^{TM}$$1.69\;{\pm}\;0.74\;MPa$ 그리고 Single $Bond^{TM}$$0.56\;{\pm}\;0.11\;MPa$로 나타났으며, AQ Bond $Plus^{TM}$와 G $Bond^{TM}$ 간에는 통계학적 유의차가 없었으나(p>0.05), AQ Bond $Plus^{TM}$와 Single $Bond^{TM}$, G $Bond^{TM}$과 Single $Bond^{TM}$ 간에는 통계학적 유의차를 보였다. 3. 주사 전자 현미경 소견에서 AQ Bond $Plus^{TM}$와 G $Bond^{TM}$는 resin tag 형성이 매우 미약하고 짧은 양상을 보인 반면, Single $Bond^{TM}$에서는 길게 형성된 resin tag가 관찰되었으며 resin tag의 표면에 불규칙하게 형성된 측부가지들이 관찰되었다.

  • PDF

차아염소산 나트륨의 사용이 복합레진 수복물의 미세누출에 미치는 영향 (INFLUENCE OF A SODIUM HYPOCHLORITE GEL ON MICROLEAKAGE OF COMPOSITE RESIN RESTORATIONS)

  • 양계식;김대업;이광희;정영남
    • 대한소아치과학회지
    • /
    • 제30권1호
    • /
    • pp.54-60
    • /
    • 2003
  • 본 연구는 영구치와 유치의 상아질 표면에 상품화된 화학기계적 우식치질 제거용액인 $Carisolv^{TM}$(MediTeam, Sweden)를 사용하고 복합레진을 접착한 후 전단결합강도를 측정함으로써 $Carisolv^{TM}$의 사용이 복합레진의 접착에 미치는 영향을 평가하고자 하였다. 교정치료를 위하여 발거된 상, 하악 소구치 80개와 정상적으로 탈락한 손상이 없이 건전한 상악 유전치 80개의 순, 협면의 상아질을 노출시키고 $Carisolv^{TM}$를 실험군은 60초 적용하고 대조군은 $Carisolv^{TM}$를 사용하지 않았다. 상아질 접착제는 Scotchbond Multi-Purpose(3M, USA), Single Bond(3M, USA), Clearfil SE Bond(Kuraray, Japan), AQ Bond(Sun Medical, Japan)를 각각 제조사의 지시대로 적용하였고 광중합형 복합레진은 Z100(3M, USA)을 사용하였다. $5^{\circ}C$$55^{\circ}C$에 각 30초씩 계류시켜 1,000회 열순환시키고 Universal Testing Machine(Zwick Z020, Zwick Co., Germany)을 사용하여 전단결합강도를 측정하고 분석하여 다음과 같은 결론을 얻었다. 1. 각 군간 전단결합강도를 비교한 결과, 유치에 비해 영구치의 전단결합강도가 높게 나타났다. 영구치에서는 Clearfil SE Bond만 사용한 군에서 가장 높았고 $Carisolv^{TM}$와 AQ Bond를 병용한 군에서 가장 낮았다. 2. $Carisolv^{TM}$ 사용하지 않은 군과 사용한 군간의 전단결합강도를 비교한 결과, 영구치와 유치 모두에서 상아질 접착제의 종류에 관계없이 $Carisolv^{TM}$를 사용한 군이 사용하지 않은 군에 비해 전단결합강도가 통계학적으로 유의하게 낮게 나타났다(P<0.001). 3. 상아질 접착제의 종류에 따른 전단결합강도를 비교한 결과, 영구치와 유치 모두에서 Clearfil SE Bond를 사용한 군의 전단결합강도가 가장 높았으며 AQ Bond를 사용한 군의 전단결합강도가 가장 낮았다.

  • PDF

상아질과 Gutta-Percha에 대한 근관충전용 Sealer의 결합강도의 측정 (MEASUREMENT OF ADHESION OF ROOT CANAL SEALER TO DENTINE AND GUTTA-PERCHA)

  • 허미자;유미경;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제28권1호
    • /
    • pp.89-99
    • /
    • 2003
  • The purpose of this study was to investigate the bonding of resin- based root canal sealer, AH26 when the sealer was applied as a thin layer between dentine and gutta-percha surface. In this study forty non-caries extracted human molars and resin-based root canal sealer(AH 26, DeTrey/Dentsply, Germany) were used. Disks of gutta-percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for thermoplastic obturation were used and dentin surfaces were treated with 2% NaOCl(Group 1) or 2%NaOCl+17% EDTA(Group 3). Disks of gutta-Percha, 6mm in diameter.6mm thick (Diadent/Dentsply, Korea) for conventional obturation were used and dentin surface were treated with 2% NaOCl(Group 2) or 2%NaOCl+17% EDTA(Group 4). Enamel was removed by a horizontal section 1mm below the deepest portion of the central occlusal groove by using a watercooled low speed diamond saw. A second horizontal section was done around cementoenamel junction. Exposed dentin surface was cut to approximately $8{\times}8{\;}mm$ rectangular shape and was ground against 320, 400, 600 grade silicon carbide abrasive paper serially. After grinding, the dentine surface were soaked in a solution of 2% NaOCl for 30 minutes and twenty of specimens were treated with 17% EDTA solution for 1 minute. The treated specimens were washed and dried, Root canal sealer, AH26 was prepared according to the manufacture's instructions The Gutta-percha and dentin surface were coated with a thin layer of the freshly mixed seal or. The specimens were left overnight at room temperature. After their initial set, they were transferred to an incubator at $37$^{\circ}C$ for 72 h. After 72 hours, resin blocks were made. The resin block was serially sectioned vertically into stick of $1{\cdot}1mm$. Twenty sticks were prepared from each group. After that, tensile bond strength f3r each stick was measured with Microtensile Tester Failure patterns of the specimens at the interface between gutta-percha and dentin were observed under the SEM(x1000) and Stereomicroscope (LEICA M42O, Meyer Inst., TX U.S.A) at 1.25 x25 magnification. The results were statistically analysed by using a One-way ANOVA and Tukey's test. The results were as follows; 1. Tensile bond strengths($mean{\pm}SD$) were expressed with ascending order as follows: Group 1, $3.09{\pm}$ 1.05Mpa : Group 2, $6.23{\pm}1.16MPa$ : Group 3, $7.12{\pm}1.07MPa$ : Group 4, $10.32{\pm}2.06MPa$. 2. Tensile bond strengths of the group 2 and 4 used disks of gutta-percha for conventional obturation were significantly higher than that of the group 1 and 3 used fir thermoplastic obturation. (p < 0.05). 3. Tensile bond strengths of the group 3 and 4 treated with 2% NaOC1+17% EDTA were significantly higher than that of the group 1 and 2 treated with 2% NaOCl. (p < 0.05). 4. In analysis of failure patterns at the interface between sealer and gutta-percha, there were observed 49 (61%)cases of adhesive failure patterns and 31 (39%) cases of mixed failures patterns.

2단계 접착제의 상아질 결합강도에 대한 Er:YAG 레이저 조사 영향 (Effect of Er:YAG lasing on the dentin bonding strength of two-step adhesives)

  • 송병춘;조영곤;이명선
    • Restorative Dentistry and Endodontics
    • /
    • 제36권5호
    • /
    • pp.409-418
    • /
    • 2011
  • 연구목적: 이 연구는 상아질 표면에 Er:YAG 레이저를 조사하지 않는 군, 레이저를 조사한 군, 레이저를 조사한 후 부가적인 산처리를 한 군으로 분류하여 2단계 단일병 전부식 접착시스템과 자가부식 프라이머 접착시스템을 이용하여 복합레진을 접착하였을 때 이러한 표면처리가 복합레진의 미세전단 결합강도와 결합계면에 미치는 영향을 비교하기 위하여 시행하였다. 연구 재료 및 방법: 32개의 발거된 대구치의 교합면측 상아질을 이용하였고, 상아질의 표면처리는 1군과 4군에서 각각 인산과 자가부식 프라이머로 하였으며, 2군과 5군은 Er:YAG 레이저로 에칭처리하였고, 3군과 6군은 레이저로 에칭한 후 다시 각각 인산과 자가부식 프라이머로 하였다. 1군, 2군, 3군은 Single Bond 2와 Z 250 (3M ESPE)을 이용하였고, 4군, 5군, 6군은 Clearfil SE Bond와 Clearfil AP-Z (Kuraray)을 이용하여 상아질 면에 Tygon tube를 접착하였다. 각 군의 미세전단 결합강도를 측정한 후 통계 처리하였고, 또한 6개의 시편에서 복합레진과 상아질 계면을 주사전자현미경하에서 관찰하였다. 결과: Single Bond 2를 사용한 군에서 2군의 결합강도는 1군과 3군보다 통계학적으로 낮게 나타났으며, Clearfil SE Bond를 사용한 군에서 4군, 5군, 6군의 결합강도는 각각 통계학적으로 유의한 차이를 나타내었다(p < 0.05). 2군과 5군은 아주 짧고 가는 레진테그가 관찰되었고, 3군과 6군은 길고 가는 레진테그와 레진테그의 측지가 관찰되었다. 결론: 레이저로 에칭 처리한 상아질에 대한 부가적인 산 처리나 자가부식 프라이머의 처리는 상아질의 접착력을 향상시켰다.