• Title/Summary/Keyword: Dental zirconia

Search Result 461, Processing Time 0.027 seconds

Comparative Study of Properties of Dental Zirconia According to Microwave Sintering Method (마이크로웨이브 소결방법에 따른 치과용 지르코니아의 물리적 특성)

  • Kim, Tae-Suk;Yu, Chin-Ho;Kim, Gi-Chul;Park, Won-Uk;Seo, Jung-Il;Hwang, Kyu-Hong
    • Journal of Technologic Dentistry
    • /
    • v.34 no.1
    • /
    • pp.11-21
    • /
    • 2012
  • Purpose: Densification and mechanical properties of dental zirconia ceramics were evaluated by different sintering methods. Materials and Methods: Y-TZP zirconia block(Kavo $Everest^{(R)}$ ZS blank, Kavo dental GmbH, Bismarckring, Germany) was used in this study. Sintering were performed in heat sintering furnace and microwave sintering furnace, and then experimented and analyzed on a change in densification according to the sintering time, a change in densification according to thickness, flexural strength and micro-structure in zirconia specimens. Results: Microwave sintering was very effective in considerable mechanical properties such as flexural strength and bulk density was drastically increased than conventional electric heating method. It is also shown that microwave sintering time was faster and more economical than common method to be present in qualities which equal or exceed. Conclusion: It will be important to seek the accurate sintering condition of dental zirconia by microwave sintering method and the continuous research is necessary for the study of relationship between sintering methods and mechanical properties.

Analysis of surface characteristics of (Y, Nb)-TZP after finishing and polishing

  • Seong-keun, Yoo;Ye-Hyeon, Jo;In-Sung Luke, Yeo;Hyung-In, Yoon;Jae-Hyun, Lee;Jin-Soo, Ahn;Jung-Suk, Han
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.335-345
    • /
    • 2022
  • PURPOSE. This in vitro study aimed to evaluate the surface characteristics of a full veneer crown fabricated chairside (CS) from a (Y, Nb)-TZP zirconia block in response to conventional zirconia grinding and polishing. MATERIALS AND METHODS. Zirconia crowns (n = 40) were first prepared and divided into two groups of materials: Labside (LS) and CS, after which each specimen went through a five-step grinding and polishing procedure. Following each surface treatment, surface characteristics were analyzed using confocal laser microscopy (CLSM), average surface roughness (Ra) values were processed from the profile data through Gaussian filtering, and X-ray diffraction pattern analysis was performed to evaluate the monoclinic (M) phase content. Then, a representative specimen was selected for field-emission scanning electron microscopy (FE-SEM), followed by a final analysis of the roughness and X-ray diffraction of the specimens using the independent t-test and repeated measures analysis of variance (RM-ANOVA). RESULTS. In every group, polishing significantly reduced the Ra values (P < .001). There was no significant difference in Ra between the polished state CS and LS. Furthermore, CLSM and FE-SEM investigations revealed that even though grain exposure was visible in CS specimens throughout the as-delivered and ground states, the exposure was reduced after polishing. Moreover, while no phase transformation was visible in the LS, phase transformation was visible in CS after every surface treatment, with the M phase content of the CS group showing a significant reduction after polishing (P < .001). CONCLUSION. Within the limits of this study, clinically acceptable level of surface finishing of (Y, Nb)-TZP can be achieved after conventional zirconia polishing sequence.

A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain

  • Jung, Yu-Seok;Lee, Jae-Whang;Choi, Yeon-Jo;Ahn, Jin-Soo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.111-115
    • /
    • 2010
  • PURPOSE. This study was conducted to evaluate clinical validity of a zirconia full-coverage crown by comparing zirconia's wear capacity over antagonistic teeth with that of feldspathic dental porcelain. MATERIALS AND METHODS. The subject groups were divided into three groups: the polished feldspathic dental porcelain group (Group 1), the polished zirconia group (Group 2), and the polished zirconia with glazing group (Group 3). Twenty specimens were prepared from each group. Each procedure such as plasticity, condensation, and glazing was conducted according to the manufacturer's manual. A wear test was conducted with 240,000 chewing cycles using a dual-axis chewing simulator. The degree of wear of the antagonistic teeth was calculated by measuring the volume loss using a three-dimensional profiling system and ANSUR 3D software. The statistical significance of the measured degree of wear was tested with a significant level of 5% using one-way ANOVA and the Tukey test. RESULTS. The degrees of wear of the antagonistic teeth were $0.119{\pm}0.059\;mm^3$ in Group 1, $0.078{\pm}0.063\;mm^3$ in Group 3, and $0.031{\pm}0.033\;mm^3$ in Group 2. Statistical significance was found between Group 1 and Groups 2 and between Group 2 and 3, whereas no statistical significance was found between Group 1 and Group 3. CONCLUSION. Despite the limitations of this study on the evaluation of antagonistic teeth wear, the degree of antagonistic tooth wear was less in zirconia than feldspathic dental porcelain, representing that the zirconia may be more beneficial in terms of antagonistic tooth wear.

Marginal fit of anterior 3-unit fixed partial zirconia restorations using different CAD/CAM systems

  • Song, Tae-Jin;Kwon, Taek-Ka;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • PURPOSE. Few studies have investigated the marginal accuracy of 3-unit zirconia fixed partial dentures (FPDs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) system. The purpose of this study was to compare the marginal fit of zirconia FPDs made using two CAD/CAM systems with that of metal-ceramic FPDs. MATERIALS AND METHODS. Artificial resin maxillary central and lateral incisors were prepared for 3-unit FPDs and fixed in yellow stone. This model was duplicated to epoxy resin die. On the resin die, 15 three-unit FPDs were fabricated per group (45 in total): Group A, zirconia 3-unit FPDs made with the Everest system; Group B, zirconia 3-unit FPDs made with the Lava system; and Group C, metal-ceramic 3-unit FPDs. They were cemented to resin dies with resin cement. After removal of pontic, each retainer was separated and observed under a microscope (Presize 440C). Marginal gaps of experimental groups were analyzed using one-way ANOVA and Duncan test. RESULTS. Mean marginal gaps of 3-unit FPDs were $60.46{\mu}m$ for the Everest group, $78.71{\mu}m$ for the Lava group, and $81.32{\mu}m$ for the metal-ceramic group. The Everest group demonstrated significantly smaller marginal gap than the Lava and the metal-ceramic groups (P<.05). The marginal gap did not significantly differ between the Lava and the metal-ceramic groups (P>.05). CONCLUSION. The marginal gaps of anterior 3-unit zirconia FPD differed according to CAD/CAM systems, but still fell within clinically acceptable ranges compared with conventional metal-ceramic restoration.

Comparison on marginal fitness and mechanical properties of copings with zirconia block and CAM type (지르코니아 블록과 CAM 종류에 따른 코핑의 변연적합도와 기계적 특성 비교)

  • Chung, In-Sung;Jeon, Byung-Wook;Kim, Won-Young;Kang, Jae-Min
    • Journal of Technologic Dentistry
    • /
    • v.39 no.2
    • /
    • pp.75-82
    • /
    • 2017
  • Purpose: This study provided the basic data for selection the zirconia block and CAM by means of marginal fitness observations, flexural strength test and hardness test. Methods: Three dental zirconia blocks(ABCera, NaturaZ, ST98) and two dental milling machines(CAD/CAM MS, DWX-50) were used in this study. Metal abutment(diameter 10 mm, height 5 mm, inclined angle $3^{\circ}$ taper, 1 mm chamfer margin) was fabricated by Ti customized abutment, and then zirconia copings were fabricated for each ten specimens. Silicone replica technique was used to observe the marginal fitness of cross-sections with a stereomicroscope at ${\times}50$ magnification. The dental zirconia blocks was cut into 10 pieces each having a size of $25mm{\times}5mm{\times}1mm$, and fabricated according to the manufacturer's instructions, and flexural strength was measured using a universal testing machine. For hardness test, a micro Vickers hardness tester was used as it was in the flexural strength test. Statistical analysis was performed by one way ANOVA and post-test was performed by Scheffe test. Results: For marginal fitness of bucco-lingual axial, ZU group($59.7{\pm}10.3{\mu}m$) was the lowest, followed by RA, ZA, ZD, RD, RU. For marginal fitness of mesio-distal axial, ZU group($59.3{\pm}10.2{\mu}m$) was the lowest, followed by RA, ZA, RD, ZD, RU. One-way ANOVA showed statistically significant difference between groups(p<0.05). For flexural strength, ABCera block($718.0{\pm}57.2MPa$) was the highest, followed by NaturaZ, ST98. For hardness, ABCera block($1550.3{\pm}19.8Hv$) was the highest, followed by ST98, NaturaZ. There was no significant difference in flexural strength and hardness between blocks(p>0.05). Conclusion: Based on the results of this study, the type of dental zirconia block did influence the marginal fitness, and all dental zirconia blocks are expected to be suitable for clinical application. The highest flexural strength and hardness were ABCera block, and no statistically significant difference was observed.

Measure of shade differences according to the concentration of dental zirconia coloring liquid (치과용 지르코니아 코어에서 착색농도에 따른 색조측정)

  • Bae, Eun-Jeong;Lee, Hee-Jung;Kim, Hae-Young;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.35 no.3
    • /
    • pp.193-200
    • /
    • 2013
  • Purpose: In this study, in order to provide objective standard of the mixed concentration of the zirconia coloring-liquids, compare the shade differences after colored zirconia blocks from different concentrations. Methods: After immersion for 2 minutes zirconia specimen ($1.5{\times}1.5{\times}0.6{\pm}0.01mm$) in coloring-liquids that produced different concentrations, were sintered in furnace dedicated. Then, it was measured in spectrophotometer and Shadepilot. It has been determined mean and standard deviation of the color difference for each group, and verified by one-way ANOVA using the (version12.0) SPSS WIN Program the difference in shade according to the concentration at the significance level of 95% confidence, it conducted a Tukey's multiple range test to post-test. Results: The mean of $L^*$ was decreased toward LN35 group, however the mean of $a^*$ and $b^*$ was increased(p<.05). There is a statistically significant difference in the results of $L^*$ post hoc test of each group was LN15-LN30/LN35, LN20-LN30/LN35, LN25-LN30/LN35, and LN30-LN35 group. The $a^*$ group, it was found that there is a statistically significant difference in all groups for each(p<.05). The $b^*$ group, it was found that there is a statistically significant difference in all groups except the LN25-LN30(p<.05). Conclusion: In order to make effective use of the coloring-liquids of zirconia, the device objective, accurate concentration measurement is required, from the present study, we presented evidence basic to this.

The influence of various core designs on stress distribution in the veneered zirconia crown: a finite element analysis study

  • Ha, Seung-Ryong;Kim, Sung-Hun;Han, Jung-Suk;Yoo, Seung-Hyun;Jeong, Se-Chul;Lee, Jai-Bong;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.187-197
    • /
    • 2013
  • PURPOSE. The purpose of this study was to evaluate various core designs on stress distribution within zirconia crowns. MATERIALS AND METHODS. Three-dimensional finite element models, representing mandibular molars, comprising a prepared tooth, cement layer, zirconia core, and veneer porcelain were designed by computer software. The shoulder (1 mm in width) variations in core were incremental increases of 1 mm, 2 mm and 3 mm in proximal and lingual height, and buccal height respectively. To simulate masticatory force, loads of 280 N were applied from three directions (vertical, at a $45^{\circ}$ angle, and horizontal). To simulate maximum bite force, a load of 700 N was applied vertically to the crowns. Maximum principal stress (MPS) was determined for each model, loading condition, and position. RESULTS. In the maximum bite force simulation test, the MPSs on all crowns observed around the shoulder region and loading points. The compressive stresses were located in the shoulder region of the veneer-zirconia interface and at the occlusal region. In the test simulating masticatory force, the MPS was concentrated around the loading points, and the compressive stresses were located at the 3 mm height lingual shoulder region, when the load was applied horizontally. MPS increased in the shoulder region as the shoulder height increased. CONCLUSION. This study suggested that reinforced shoulder play an essential role in the success of the zirconia restoration, and veneer fracture due to occlusal loading can be prevented by proper core design, such as shoulder.

The effect of zirconia surface architecturing technique on the zirconia/veneer interfacial bond strength

  • Her, Soo-Bok;Kim, Kyoung Hun;Park, Sang Eun;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.259-264
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the effect of the zirconia surface architecturing technique (ZSAT) on the bond strength between veneering porcelain and zirconia ceramic. MATERIALS AND METHODS. 20 sintered zirconia ceramic specimens were used to determine the optimal surface treatment time, and were randomly divided into 4 groups based on treatment times of 0, 1, 2, and 3 hours. After etching with a special solution, the surface was observed under scanning electron microscope, and then the porcelain was veneered for scratch testing. Sixty 3 mol% yttria-stabilized tetragonal zirconia polycrystal ceramic blocks were used for tensile strength testing; 30 of these blocks were surface treated and the rest were not. Statistical analysis was performed using ANOVA, the Tukey post-hoc test, and independent t-test, and the level of significance was set at ${\alpha}=.05$. RESULTS. The surface treatment of the zirconia using ZSAT increased the surface roughness, and tensile strength test results showed that the ZSAT group significantly increased the bond strength between zirconia and veneering porcelain compared to the untreated group (36 MPa vs. 30 MPa). Optimal etching time was determined to be 2 hours based on the scratch test results. CONCLUSION. ZSAT increases the surface roughness of zirconia, and this might contribute to the increased interfacial bond strength between zirconia and veneering porcelain.

Influence of coloring liquids on the shear bond strength between zirconia and veneering ceramic (색소체용액 침투가 지르코니아 및 전장용 세라믹의 전단결합강도에 미치는 영향)

  • Jung, Jong-Hyun;Oh, Gye-Jeong
    • Journal of Technologic Dentistry
    • /
    • v.38 no.4
    • /
    • pp.291-298
    • /
    • 2016
  • Purpose: This study was to evaluate the effect of coloring liquids on the shear bond strength between zirconia and veneering ceramic. Methods: Zirconia(15 mm in diameter, 2.5 mm in thickness; n=40) used in the experiment were divided into 5 groups depending on the coloring liquid. Each specimen were polished using a polishing machine(LaboPol-2, Struers, UK). A cylinder of veneering porcelain(6 mm in diameter, 3 mm in thickness) was fabricated and fired on zirconia surfaces. The shear bond strength was measured using a universal testing machine(Model 4302, Instron, USA). All data were analyzed statistically using a one-way ANOVA and Tukey's multiple comparisons test. After the shear bond test, fracture surfaces were examined by SEM. Results: Colored zirconia showed a higher shear bonding strength than that of uncolored zirconia except for colored zirconia immersed in Zirkonzahn coloring liquid. In particular, colored zirconia immersed in Kuwotech coloring liquid showed the highest shear bond strength. After the shear bond test, mixed failure patterns were mainly observed in the failure between zirconia and veneering ceramic. Conclusion: Coloring liquid enhanced the shear bond strength zirconia and veneering ceramic than uncolored zirconia.

Effects of colored zirconia surface treatment on the bond strength of veneering ceramics

  • Kim, SA-Hak;Kim, Chong-Kyen
    • Journal of Technologic Dentistry
    • /
    • v.43 no.4
    • /
    • pp.160-167
    • /
    • 2021
  • Purpose: In this study, when the etching treatment method, which is a chemical surface treatment method, is applied to colored zirconia, the shear bond strength between the veneering ceramic material and colored zirconia is compared with that without surface treatment, and the fracture type is observed to evaluate the etching treatment effect of colored zirconia. Methods: Experiments were conducted after dividing the study sample into two groups, which are the zirconia control group without surface treatment using colored zirconia blocks (without etching zirconia, NZC group) and the zirconia group treated with a commercially available etching solution (etching liquid zirconia, EZC group). Results: The mean shear bond strength of the NZC group was 20.31±2.32 Mpa, and that of the EZC group was 25.95±2.34 Mpa, and the difference between these two values was statistically significant (p<0.05). Further, the surface roughness Ra value was higher in the EZC group than in the NZC group. In the fracture pattern, cohesive fractures were dominant, and adhesive fractures and cohesive fractures were mixed. Conclusion: The bond strength was significantly higher in the group treated with colored zirconia. The fracture pattern was mostly cohesive failure in the group not treated with etching and changed to mixed failure as the etching treatment progressed.