• 제목/요약/키워드: Dental wear

검색결과 236건 처리시간 0.025초

치과용 Titanium 주조합금의 마멸특성 (Wear Properties of Cast Titanium Alloys for Dental Use)

  • 최석규;김형일;박익민
    • 한국주조공학회지
    • /
    • 제11권6호
    • /
    • pp.482-490
    • /
    • 1991
  • This study presents the wear characteristics of Ti alloys (Pure Ti, Ti-6Al-4V, Ti-5Al-2.5Sn) fabricated by centrifugal precision casting in an Ohara dental titanium casting machine. It was found that the hardness of the surface region is higher than that of the interior region. It is considered that the oxygen adsorption in the surface region during casting, leads to the interstitial solid solution hardening. Wear resistance incerases in the order of pure Ti, Ti-6Al-4V, Ti-5Al-2.5Sn alloys. The interior hardness value increases in the same order. The specific wear rate increases with applied load and increases monotonously with sliding speed. The Fe transfer from the counterpart material was observed on the worn surface of the Ti-5Al-2.5Sn alloy. Oxidative wear occurs at low sliding speeds and mechanical fracture wear occurs at high sliding speeds.

  • PDF

Comparative analysis on intaglio surface trueness, wear volume loss of antagonist, and fracture resistance of full-contour monolithic zirconia crown for single-visit dentistry under simulated mastication

  • Kim, Yong-Kyu;Yoon, Hyung-In;Kim, Dae-Joon;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권3호
    • /
    • pp.173-181
    • /
    • 2022
  • PURPOSE. This analysis aimed to evaluate the intaglio surface trueness, antagonist's wear volume loss, and fracture resistance of full-contour crowns of (Y, Nb)-stabilized fully-sintered zirconia (FSZ), 4 mol% or 5 mol% yttria-stabilized partially sintered zirconia (4YZ or 5YZ) with high-speed sintering. MATERIALS AND METHODS. A total of 42 zirconia crowns were separated into three groups: FSZ, 4YZ, and 5YZ (n = 14). The intaglio surface trueness of the crowns was evaluated at the inner surface, occlusal, margin, and axial areas and reported as root-mean-square, positive and negative average deviation. Half of the specimens were aged for 120,000 cycles in the chewing simulator, and the wear volume loss of antagonist was measured. Before and after chewing, the fracture load was measured for each group. The trueness values were analyzed with Welch's ANOVA, and the wear volume loss with the Kruskal-Wallis tests. Effect of the zirconia type and aging on fracture resistance of crowns was tested using two-way ANOVA. RESULTS. The intaglio surface trueness measured at four different areas of the crown was less than 50 ㎛, regardless of the type of zirconia. No significant P in wear volume loss of antagonists were detected among the groups (P > .05). Both the type of zirconia and aging showed statistically significant effects on fracture resistance (P < .05). CONCLUSION. The full-contour crowns of FSZ as well as 4YZ or 5YZ with high-speed sintering were clinically acceptable, in terms of intaglio surface trueness, antagonist's wear volume loss, and fracture resistance after simulated mastication.

치과용 재료 Supper-A의 트라이볼로지적 고찰 (Tribological Performance of Supper-A Dental Material)

  • 최원식;김원구;권순홍;정성원;권순구;박종민
    • Tribology and Lubricants
    • /
    • 제23권6호
    • /
    • pp.318-322
    • /
    • 2007
  • The wear characteristics in supre-A dental material have been investigated. The wear tests were performed by using pin-on-disk wear tester at room temperature. Vickers hardness and fracture toughness measurement of dental materials were preformed. Microscopic observations on worn surfaces of specimens were conducted by SEM. The friction coefficient of supper-A material was investigated according to weight and slinging velocity. The hardness of supper-A material was a half of the enamel of natural teeth.

Polyaryletherketones (PAEKs)로 제작된 임플란트 유지형 어태치먼트의 유지력 평가 (Evaluation of the initial retention of implant-retained attachments made of dental polyaryletherketones (PAEKs))

  • 박수철;김성민
    • 대한치과기공학회지
    • /
    • 제45권3호
    • /
    • pp.61-66
    • /
    • 2023
  • Purpose: The current study examined the retention and wear resistance of stud-type attachments made of high-performance polyetheretherketone (PEEK) or polyetherketoneketone (PEKK) from the polyaryletherketones (PAEKs) family. Methods: The study sample included 10 PEEK or PEKK attachments that were mounted onto their male parts, designed on the upper aspect of the attachment, with a load of 30 N. Tensile stress was applied using an Instron machine to separate the male and female parts, and the maximum tensile stress to be applied was determined based on the retention force observed. The wear resistances of PEEK and PEKK were evaluated by measuring the inner diameter of the inserted female part 10 times. Results: The maximum tensile stresses of PEEK and PEKK were 56.26±0.58 and 69.12±0.92 N, respectively, with the maximum stress required to remove the PEKK specimens from the abutment being 12.86 N higher than that required to remove the PEEK specimens. Furthermore, PEKK exhibited higher wear resistance than PEEK. Conclusion: This study evaluated custom-made removable implant-retained attachment components for overdentures, wherein the female parts were made of PEEK or PEKK. The retention stress and wear resistance were evaluated based on the type of attachment material, and the results showed that both types of attachment inserts demonstrated clinically acceptable results in terms of retention.

치과내원환자의 치과감염관리에 대한 인식 및 요구도에 관한 연구 (A study on the perception and needs about dental infection control of the dental patients)

  • 이경희;양지은;문선호;김지은
    • 한국치위생학회지
    • /
    • 제17권3호
    • /
    • pp.343-354
    • /
    • 2017
  • Objectives: The purpose of this study was to provide a satisfactory and reliable dental care service for the patients and to establish a plan to raise the perception about dental infection control. Methods: The perception of infection control in the dental clinic of the patients was examined who visited to dental clinics, over 20 years old and living in Seoul and Gyeonggi province since December 2016. The questionnaire was used as the survey tool, and 274 questions in the questionnaire were analyzed. Results: Results of examined factors affecting the perception of dental infection control in dental clinics show that the perception of infection control in dental clinics is affected by the degree of university graduates (p<0.05), full-time workers (p<0.01), housewives (p<0.001), and oral health concerns (p<0.05), the perception of infection control of dental medical personnel (p<0.001) in order. Conclusions: Dental medical personnels must thoroughly wash their hands, wear uniforms, wear personal protective equipment, and thoroughly clean and disinfect the interior of a dental clinic.

In vitro wear behavior between enamel cusp and three aesthetic restorative materials: Zirconia, porcelain, and composite resin

  • Jang, Yong-Seok;Nguyen, Thuy-Duong Thi;Ko, Young-Han;Lee, Dae-Woo;Baik, Byeong Ju;Lee, Min-Ho;Bae, Tae-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.7-15
    • /
    • 2019
  • PURPOSE. The aim of this study was to identify the effects of three aesthetic restorative materials on the wear between tooth and restoration by a pin-on-disk manner. MATERIALS AND METHODS. Six aesthetic restorative materials were used to prepare disk specimens for wear test, which were Lava Zirconia as zirconia group, Vintage MP and Cerabien ZR as veneering porcelain group, Gradia Direct microhybrid composite containing prepolymerized fillers, Filtek Z250 microhybrid composite containing zirconia glass and colloidal silica particles, and Filtek Z350 nanocomposite as composite resin group. Vertical loss of the worn cusp, change of the surface roughness of the restoration materials, and the surface topography were investigated after wear test under 9.8-N contact load. RESULTS. The porcelain groups (Vintage MP and Cerabien ZR) caused the largest vertical loss of teeth when compared with those of the composite resin and zirconia groups, and Filtek Z250 microhybrid composite results in the second-largest vertical loss of teeth. The surface of Filtek Z350 nanocomposite was deeply worn out, but visible wear on the surface of the zirconia and Gradia Direct microhybrid composite was not observed. When the zirconia surface was roughened by sand-blasting, vertical loss of teeth considerably increased when compared with that in the case of fine polished zirconia. CONCLUSION. It was identified that microhybrid composite resin containing a prepolymerized filler and zirconia with reduced surface roughness by polishing were the most desirable restorative materials among the tested materials to prevent the two-body wear between aesthetic restorative material and tooth.

Metal stain on monolithic zirconia restoration: A case report

  • Cha, Min-Sang;Lee, Sang-Woon;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권2호
    • /
    • pp.138-142
    • /
    • 2017
  • In restorative treatment using fixed dental prostheses, dentists should select appropriate restoration material among various types of dental materials. The strength, marginal fit, esthetics, wear resistance, biocompatibility, and cost are important factors in the choice of restoration materials. The present case showed a surface stain on a monolithic zirconia restoration that was due to wear between the monolithic zirconia restoration and the base metal alloy restoration. This phenomenon was confirmed by surface roughness measurement and electron probe micro-analysis.

대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구 (Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials)

  • 박영배
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF

레이저가 치과주조용 비귀금속합금에 미치는 영향에 관한 실험적 연구 (AN EXPERIMENTAL STUDY OF LASER EFFECTS ON A BASE METAL ALLOY FOR DENTAL CASTING)

  • 김경남
    • 대한치과의사협회지
    • /
    • 제22권9호통권184호
    • /
    • pp.781-792
    • /
    • 1984
  • The purpose of this experiment was to study the effects of laser on a base metal alloy for dental casting. In this study, microhardness, corrosion resistance, wear resistance, interaction behavior of metal-ceramic interface, and bond strength were tested before and after the laser treatment for metal-ceramic alloy. The conclusion arised from this study are as follows: 1. The hardness of lased area was higher than that of unlased area. 2. The corrosion resistance was higher in lased specimen than in unlased specimen. 3. the wear resistance was higher in Iased specimen than in unlased specimen. 4. The EDAX showed that Mo, Si and Al were increased in lased surface but Ni and Cr not increased. 5. The SEM of lased area revealed a typical microstructure. 6. The bond strength of lased specimen was increased in 11.2% than of unlased specimen.

  • PDF

수종 레진 인공치의 마모도에 관한 연구 (A Study on the Wear of Artificial Resin Teeth)

  • 이정오
    • 대한치과기공학회지
    • /
    • 제20권1호
    • /
    • pp.51-60
    • /
    • 1998
  • The artificial resin teeth used for removable prosthesis have good physical properties, but they have great wear rate. The purpose of this study is to compare the wear characteristics of several artificial resin teeth, such as Myerson teeth(Myerson Crop), Trubite IPN(Dentsply), Endura Posterio(Shofu), SROrthosit(Ivoclar), Trubite Biotone(Dentsply), Five samples of each resin tooth were abraded against natural teeth, type III gold for 150,000 cycles on the wear machine. The results obtained were as follow 1. The wear rate of artificial resin teeth when opposing enamel was the lowest in Myerson teeth($8.60{\mu}m$), followed by Trubite IPN($41.30{\mu}m$), Endure poster($63.00{\mu}m$), SR-Orthosit($68.40{\mu}m$), Trubite Biotone($209.90{\mu}m$) 2. The wear rate of artificial teeth when opposting type III gold specimens was the lowest in Myerson teeth($13.50{\mu}m$) followed by Endura Posterio($14.75{\mu}m$), Trubite IPN($53.40{\mu}m$), SROrthosit($54.20{\mu}m$), Trubite Boitone($341.50{\mu}m$)

  • PDF