• Title/Summary/Keyword: Dental technique

Search Result 1,116, Processing Time 0.025 seconds

Comparisons Fitness in Implant Abutment between Gas Soldering and Laser Welding

  • Cho, Mi-Hyang;Nam, Shin-Eun
    • International Journal of Clinical Preventive Dentistry
    • /
    • v.14 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • Objective: Osseointegration is essential process for successful implants and effects to implant in long term, therefore, passive fitness of good prosthesis is necessary. To make a good prosthesis, at first it should be done a sectioned casting and then joined method of sectioned casting body is recommended. Methods: In this study, to provide the fundamental data on stable connection method for successful implants, the author tested fitness of casting body, and compared difference between gas soldering technique and laser welding technique. Results: In fitness test of 2 abutment (test A, C), gas soldering group's fitness in the opposite part of connection was worse than laser welding group. In fitness test of 3 abutment (test B, D), gap distance was increased both in gas soldering technique and laser welding technique. Gap distance at the connecting part and the opposite part of the abutment in gas soldering technique was worse than laser welding technique and the more additional abutment, the worse gap distance in gas soldering technique. In fitness test of 3 abutment (test B, D), there's little variation in No. 2 abutment when connecting soldering process was done and there's little influence on already soldered connection part when the additional soldering connection was done. Conclusion: On weak loading condition and the part which is needed an accuracy, laser welding technique is more effective and on long-span prosthesis and frequent chewing loading part, laser welding technique is recommended first and applying additional gas soldering technique would be better for making much more successful prosthesis.

Current concepts of Laser dentistry (임상가를 위한 특집2 - Current concepts of Laser dentistry)

  • Eun, Hee-Jong
    • The Journal of the Korean dental association
    • /
    • v.49 no.11
    • /
    • pp.670-678
    • /
    • 2011
  • Various sorts of dental devices for the dental treatment have been introduced and adopted during past several years. Dental Laser, among all devices, seems to be possible for applying to over the whole treatments and widely employed. Furthermore, this article is to introduce that Dental Laser is intended to care patients secured with the effectual treatment against Conventional procedures based upon its studies. The advantages of Dental Laser treatment-along with LLLT (Low Level Laser Therapy) effect, biostimulation effect, and minimal invasive technique - make the patients reduce their fear of the operation, lighten the inconvenience of post operation, and shorten the treatment period. In particular, it is worth considering that the use of laser-assisted therapies is associated with a marked reduction in the use of analgesics and anti-inflammatory medications compared with conventional procedures. This article is to state advantages and differences of Dental Laser treatment compared with Conventional procedures, and to emphasize to become well-acquainted with the precautions for safety and effective Dental Laser treatment. In case of operating Dental Laser with lack of the instructions, it will cause the unpredicted fatal results; therefore this treatment requires special care in its operation. Henceforward, it is anticipated that infinite treatment protocols will be introduced by applying Dental Laser, and this is to address the utilization of Dental Laser.

Improved stress analyses of dental systems implant by homogenization technique (균질화기법을 이용한 치과 임플란트 시스템의 응력해석)

  • Koh, Chul-Su;Lee, Man-Sup;Choi, Kui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.263-290
    • /
    • 1997
  • Homogenization technique is employed to investigate the series of stress analyses of mandible for three different types of dental implants. This technique helps to make proper material model of bone and analyze such a non homogeneous structure at the level of individual microstructural unit. The stress analyses with homogenization technique show much higher stress level in the sponge bone, compared to those of conventional FEM. It also manifested that even a minor lateral force results in crucial stresses in the dental implant system and that the macroscale model should take the shape and size after real mandible to produce reasonable solution in the analyses of dental implant systems. The shapes of dental implants simulated in this study are rectangular-cross-sectioned type, hemi-sphere rooted type, and wedge type implant. The stress states of mandible with hemisphere rooted type implant and wedge type implant show similar levels, while those with sectioned rectangular implant results in higher stresses. It is suggested that the distance between the implant tip and cortical bone be kept far enough to prevent stress concentrations in the mandible.

  • PDF

Clinical performance of class I cavities restored with bulk fill composite at a 1-year follow-up using the FDI criteria: a randomized clinical trial

  • Chinni Suneelkumar ;Puttaganti Harshala ;Koppolu Madhusudhana;Anumula Lavanya;Anirudhan Subha ;Sannapureddy Swapna
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.24.1-24.11
    • /
    • 2021
  • Objectives: The present study aimed to evaluate the survival rate and clinical performance of class 1 composite restorations restored with the Filtek Bulk Fill composite material using either the bulk fill technique or the incremental technique at baseline (1 week) and at 3, 6 and 12 months of follow-up. Materials and Methods: Forty-two patients with at least 2 carious teeth were selected. Following randomization, one tooth was restored with the Filtek Bulk Fill composite using the incremental fill technique, and the other tooth was restored with the same material using the bulk fill technique. Patients were recalled for follow-up at baseline (1 week) and 3, 6, and 12 months and evaluated using the FDI criteria. Results: The data were analyzed using the McNemar χ2 test. No statistically significant differences were found between the scores of teeth restored with either technique. At baseline and at 3, 6, and 12 months of follow-up; there were no significant difference in the clinical status of both groups of restorations. Conclusions: Within the limitations of this study, using the bulk fill technique for restorations with the Filtek Bulk Fill material seems to be equally efficient to using the incremental fill technique.

The feasibility of needleless jet injection versus conventional needle local anesthesia during dental procedures: a systematic review

  • Alreem Ahmed, Alameeri;Hessa AlFandi, AlShamsi;Amel, Murad;Mariam Mahmoud, Alhammadi;Meznah Hamad, Alketbi;Arwa, AlHamwi;Natheer Hashim Al, Rawi;Sausan Al, Kawas;Marwan Mansoor, Mohammed;Shishir Ram, Shetty
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.6
    • /
    • pp.331-341
    • /
    • 2022
  • This systematic review evaluates current evidence regarding the feasibility of using needleless jet injection instead of a conventional local anesthetic needle. EBSCO, ProQuest, PubMed, and Scopus databases were used to identify relevant literature published in English from 2005 to 2020. Ten studies were selected. Five of them were randomized clinical trials, 3 case-control studies, and 2 equivalence trials. Using the Critical Appraisal Skills Program checklist, 6 studies scored between 67% and 100%, and 4 studies scored between 34% and 66%. According to Jadad's scale, 2 studies were considered strong, and 8 studies were considered moderate in quality. The results of the 10 studies showed differences in patient preference for needleless jet injection. Needleless injection technique has been found to be particularly useful in uncooperative patients with anxiety and needle phobia. Needleless jet injection is not technique sensitive. However, with needleless jet anesthesia, most treatments require additional anesthesia. Conventional needle anesthesia is less costly, has a longer duration of action, and has better pain control during dental extraction. Needleless jet anesthesia has been shown to be moderately accepted by patients with a fear of needles, has a faster onset of action, and is an efficient alternative to conventional infiltration anesthesia technique.

Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value

  • Yoon, Hong-Gi;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Su-Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.1
    • /
    • pp.10-15
    • /
    • 2011
  • PURPOSE. This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS. Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS. In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION. Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone.

A simple technique for impression taking of teeth and functionally generated paths

  • Yamamoto, Takatsugu;Sato, Yohei;Watanabe, Hidehiko;Punj, Amit;Abe, Minoru;Momoi, Yasuko;Ohkubo, Chikahiro
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.9.1-9.6
    • /
    • 2018
  • The objective of this case report is to introduce a simple technique for simultaneously taking a closed-mouth impression and functionally generated path (FGP) for a full coverage crown restoration. A monolithic zirconia crown was the restoration of choice. An alginate impression of the abutment tooth was taken to fabricate a custom-made closed-mouth impression tray covering the abutment tooth and the adjacent teeth. The tray had an FGP table and an abutment tray in cameo and intaglio surfaces, respectively. The impression was taken with silicone impression material after adjusting the abutment tray and inscribing the FGP using self-curing acrylic resins. Plaster casts were made from the impression, and a zirconia crown was fabricated. The crown was cemented to the abutment tooth with minimal adjustments. This simple technique resulted in a well-fitting crown that accounted for mandibular movements. Using the custom closed-mouth impression tray incorporating an FGP table simultaneously aids in fabricating an accurately fitting restoration that incorporates harmonious mandibular movements using a single impression capture.

A Comparative study of Simple Tracing with Gothic Arch Tracing (Gothic arch tracing technique에 비교된 Simple tracing에 관한 연구)

  • Bae, Bong-Jin
    • Journal of Technologic Dentistry
    • /
    • v.2 no.1
    • /
    • pp.25-27
    • /
    • 1980
  • In the process of arranging artificial teeth the simple atracing technique was shown to be more precise and convenient for general use in dental clinic than gothic arch tracing. The simple tracing technique had some advantages over other ones in that they were very useful to check protrusive, lateral and central occlusion of mandible movement, and it was very easy to transfer the oral condition and mandible movements precisely onto the articulator. Also the technique was more effective than when using wax bite in that the functional movement range has shifted to 0.2 - 0.4mm form central occlusion.

  • PDF

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.