• Title/Summary/Keyword: Dental technique

Search Result 1,116, Processing Time 0.021 seconds

Advantages of anterior inferior alveolar nerve block with felypressin-propitocaine over conventional epinephrine-lidocaine: an efficacy and safety study

  • Shinzaki, Hazuki;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.2
    • /
    • pp.63-68
    • /
    • 2015
  • Background: Conventional anesthetic nerve block injections into the mandibular foramen risk causing nerve damage. This study aimed to compare the efficacy and safety of the anterior technique (AT) of inferior alveolar nerve block using felypressin-propitocaine with a conventional nerve block technique (CT) using epinephrine and lidocaine for anesthesia via the mandibular foramen. Methods: Forty healthy university students with no recent dental work were recruited as subjects and assigned to two groups: right side CT or right side AT. Anesthesia was evaluated in terms of success rate, duration of action, and injection pain. These parameters were assessed at the first incisor, premolar, and molar, 60 min after injection. Chi-square and unpaired t-tests were used for statistical comparisons, with a P value of < 0.05 designating significance. Results: The two nerve block techniques generated comparable success rates for the right mandible, with rates of 65% (CT) and 60% (AT) at both the first molar and premolar, and rates of 60% (CT) and 50% (AT) at the lateral incisor. The duration of anesthesia using the CT was $233{\pm}37min$, which was approximately 40 min shorter than using the AT. This difference was statistically significant (P < 0.05). Injection pain using the AT was rated as milder compared with the CT. This difference was also statistically significant (P < 0.05). Conclusions: The AT is no less successful than the CT for inducing anesthesia, and has the added benefits of a significantly longer duration of action and significantly less pain.

A Study on the Accuracy of Dental Abutments Manufactured by the Dental CAD/CAM Round Bar Milling Method and CNC Milling Machine (치과용 CAD/CAM 환봉밀링 방식과 CNC 밀링기를 통해 제작된 치과용 어버트먼트의 적합 정밀도 분석)

  • JUNG SOOK KIM
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.67-71
    • /
    • 2023
  • Recently, the method of making a dental prothesis is changed in the ICT based digital way. In particular, with the emergence of the CAD/CAM or 3D printing for dental purpose, a computer based digital type is selected gradually more than an analog type. To make an implant abutment, it is possible to apply the conventional technique of making round bars, or the technique using a CNC milling machine. This study tested these two types of the techniques to find which one had more precision and a smaller error when the margin and occlusal surface was made. According to the test, the technique using a CNC milling machine to make an implant abutment had a small error and supported precise processing in terms of the margin fit and the occlusal surface. Therefore, it was found to be useful in making a custom-made prothesis.

Dental Hygienists' Perception of the Usefulness of Clinic Practice Training (임상실습 내용 및 활동의 유용성에 대한 치과위생사의 인식)

  • Jang, Gye-Won;Kang, Yong-Ju;Won, Boak-Yeon
    • Journal of Korean society of Dental Hygiene
    • /
    • v.6 no.3
    • /
    • pp.203-218
    • /
    • 2006
  • The purpose of this study was to measure dental hygienists' perception of the usefulness of clinical practice training. A total of 195 dental hygienists participated in the study. The findings of the study were analyzed according to age, the type of hospitals where respondents were working, experience in clinical practices and educational level as follows: 1. There were statistically significant differences in perception of the usefulness of the practice of amalgam filling preparation performed for dental operation among subjects at different ages (p<.01). 2. There were statistically significant differences in perception of the usefulness of the practice of paralleling technique(p<.001), the practice of amalgam filling preparation(p<.01) and the practice of trauma treatment preparation(p<.05) among subjects working at different clinics 3. Significant differences were observed in perception of the usefulness of the practice of sterilization(p<.05), the practice of suction(p<.05), the practice of history taking preparation (p<.01) and the practice of halitosis patient management preparation(p<.05) among subjects with different years of experience in clinical practices. 4. Significant differences were found in perception of the usefulness of the practice of paralleling technique among subjects with different education levels. The findings of the study suggest the need for strengthening education programs for clinical training content and practices which subjects considered important for their job. At the same time, the study emphasizes the need for developing training programs designed to produce dental hygiene preceptor who can provide dental hygienists with practical clinical training in cooperation with college and dental clinics.

  • PDF

In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials

  • Choi, Yu-Sung;Kim, Sung-Hun;Lee, Jai-Bong;Han, Jung-Suk;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.162-169
    • /
    • 2012
  • PURPOSE. Fracture of the veneering material of zirconia restorations frequently occurs in clinical situations. The purpose of this in vitro study was to compare the fracture strengths of zirconia crowns veneered with various ceramic materials by various techniques. MATERIALS AND METHODS. A 1.2 mm, $360^{\circ}$ chamfer preparation and occlusal reduction of 2 mm were performed on a first mandibular molar, and 45 model dies were fabricated in a titanium alloy by CAD/CAM system. Forty-five zirconia copings were fabricated and divided into three groups. In the first group (LT) zirconia copings were veneered with feldspathic porcelain by the layering technique. In the second group (HT) the glass ceramic was heat-pressed on the zirconia coping, and for the third group (ST) a CAD/CAM-fabricated high-strength anatomically shaped veneering cap was sintered onto the zirconia coping. All crowns were cemented onto their titanium dies with Rely $X^{TM}$ Unicem (3M ESPE) and loaded with a universal testing machine (Instron 5583) until failure. The mean fracture values were compared by an one-way ANOVA and a multiple comparison post-hoc test (${\alpha}$= 0.05). Scanning electron microscope was used to investigate the fractured interface. RESULTS. Mean fracture load and standard deviation was $4263.8{\pm}1110.8$ N for Group LT, $5070.8{\pm}1016.4$ for Group HT and $6242.0{\pm}1759.5$ N for Group ST. The values of Group ST were significantly higher than those of the other groups. CONCLUSION. Zirconia crowns veneered with CAD/CAM generated glass ceramics by the sintering technique are superior to those veneered with feldspathic porcelain by the layering technique or veneered with glass ceramics by the heat-pressing technique in terms of fracture strength.

Three-dimensional accuracy of different correction methods for cast implant bars

  • Kwon, Ji-Yung;Kim, Chang-Whe;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.39-45
    • /
    • 2014
  • PURPOSE. The aim of the present study was to evaluate the accuracy of three techniques for correction of cast implant bars. MATERIALS AND METHODS. Thirty cast implant bars were fabricated on a metal master model. All cast implant bars were sectioned at 5 mm from the left gold cylinder using a disk of 0.3 mm thickness, and then each group of ten specimens was corrected by gas-air torch soldering, laser welding, and additional casting technique. Three dimensional evaluation including horizontal, vertical, and twisting measurements was based on measurement and comparison of (1) gap distances of the right abutment replica-gold cylinder interface at buccal, distal, lingual side, (2) changes of bar length, and (3) axis angle changes of the right gold cylinders at the step of the post-correction measurements on the three groups with a contact and non-contact coordinate measuring machine. One-way analysis of variance (ANOVA) and paired t-test were performed at the significance level of 5%. RESULTS. Gap distances of the cast implant bars after correction procedure showed no statistically significant difference among groups. Changes in bar length between pre-casting and post-correction measurement were statistically significance among groups. Axis angle changes of the right gold cylinders were not statistically significance among groups. CONCLUSION. There was no statistical significance among three techniques in horizontal, vertical and axial errors. But, gas-air torch soldering technique showed the most consistent and accurate trend in the correction of implant bar error. However, Laser welding technique, showed a large mean and standard deviation in vertical and twisting measurement and might be technique-sensitive method.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.