• Title/Summary/Keyword: Dental school

Search Result 7,501, Processing Time 0.037 seconds

Alteration of Anaerobic Bacteria and S. mutans Count in Oral Cavity after Occlusal Stabilization Appliance Use (교합안정장치 사용에 따른 구강 내 혐기성 세균과 S. mutans의 변화)

  • Byun, Jin-Seok;Suh, Bong-Jik
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.375-381
    • /
    • 2007
  • Occlusal stabilization appliance is one of the most common treatment option for management of temporomandibular disorders. It acts in oral cavity for several hours per day, and usually it will take at least 6 months to 2 years of total wearing periods to take a treatment goal. In the oral cavity, occlusal stabilization appliance, unintentional manner, is able to acts as a reservoir of bacteria and protect bacteria from saliva and oxygen. This condition is so favorable to many bacteria such as S. mutans and other anaerobes, usually have been reported as causative factors of dental caries, periodontal disease and oral malodor. In this study, we investigated anaerobic bacteria and S. mutans count before and after occlusal stabilization appliance use to evaluate the possible role of occlusal stabilization appliance as protector of these bacteria. Four men(average 27.5 years) wore maxillary occlusal stabilization appliance at each night(average 9 hours) for 5 days. we swabbed saliva-plaque mixed sample at 3 different site(maxillary left 2nd molar, maxillary left central incisor, mandibular left 2nd molar) before and after occlusal stabilization appliance use. Each samples were plated in (1) anaerobic blood agar medium, (2) selective S. mutans medium(MS-MUTV) and incubated in anaerobic chamber($CO^2$ 10%, $37^{\circ}C$) for 72 hours. Each bacterial colony forming unit(CFU) were counted with naked eyes. From obtained data, we can conclude as follows: 1. There was some changes about anaerobic bacteria and S. mutans count in oral cavity after occlusal stabilization appliance use. 2. The number of anaerobic bacteria was significantly increased at maxillary 2nd molar(P=0.003), maxillary central incisor(P=0.020) after occlusal stabilization appliance use compared with before. 3. Occlusal stabilization appliance use itself had indirect effect to increase the number of anaerobic bacteria at other uncovered opponent tooth site. 4. The number of S. mutans was significantly increased at maxillary 2nd molar(P=0.043), maxillary central incisor (P=0.049) after occlusal stabilization appliance use compared with before. 5. Occlusal stabilization appliance use itself had not any effect on the number of S. mutans at other uncovered opponent tooth site.

PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY FIXED PROSTHESES WITH RIGID OF NONRIGID CONNECTION BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED IMPLANT (골육착성 보철 치료시 임플랜트와 자연 지대치와의 연결 방법에 따른 관탄성 응력 분석)

  • Kim, Young-Il;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.271-300
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstrcture. This investigation evaluated the stress patterns in a photoelastic model produced by three different types of dental implants such as Branemark, Steri-Oss, IMZ and resin tooth using the techniques of quasi three dimensional photoelasticity. The teeth-supported bridge had a first molar pontic supported by second premolar and second molar as a control group. The implant and toothsupported bridge had a first molar pontic supported by second premolar and implant posterior retainer as an experimental group. Prostheses were mechanically connected to an adjacent second premolar by the rigid of nonrigid connection, Nonrigid connection used an attachment placed between the tooth-supported and fixture-supported component. The female(keyway) of attachment was placed on the distal end of the retainer supported by the tooth ; the male(Key) of attachment connected to the osseointegrated bridge was engaged into the keyway. All prostheses were casted in the same nonprecious alloy and were cemented and screwed on their respective abutments and implants. 16㎏ of vertical loads on central fossae of second premolar, first molar pontic, implant of second molar were applied respectively and 6.5㎏ of inclined load on middle buccal surface of first molar pontic was applied. The results were as follows : 1. Under the vertical load on the central fossa of first mloar pontic, the stress developed at the apex of tooth of implat was more uniformly distributed in the case of nonrigid connection than in the case of rigid connection. 2. Under the vertical load on the central fossa of first molar pontic, the stress developed around the cervical area of tooth of implant was larger in the case of rigid connection than in the case of nonrigid connection because the bending moment was more occured in the case of rigid connection than in the case of nonrigid connection. 3. Stress was more restricted to the loaded side of nonrigid connection than to that of rigid connection 4. Under the inclined load. The set screw loosening of implant was more easily occured in the case of nonrigid connection than in the case of rigid connection due to torque moment. 5. In the case of Branemark implant, the stress concentration in second premolar was larger and the stress developed around the cervical area of implant was lower than any other cases under the vertical load, because Branemark implant with the flexible gold screw was showed in incline toward second premolar by a bending moment. 6. The stress developed around the apex of tooth or implant was more uniformly distributed in the case of Steri-Oss implant with stiff screw than in the case of Branemark implant under the vertical load. But, the stress developed around the cervical area of the Steri-Oss implant was larger than that of any other implants because bending moment was occured by vertical migration of second premolar. 7. The stress distribution in the case of IMZ implant was similar to the case of natural teeth under small vertical load. But, the residual stress around the implant was showed to occurdue to deformation of IMC and sinking of screw under larger vertical load.

  • PDF

Effect of Er:YAG lasing on the dentin bonding strength of two-step adhesives (2단계 접착제의 상아질 결합강도에 대한 Er:YAG 레이저 조사 영향)

  • Song, Byeong-Choon;Cho, Young-Gon;Lee, Myung-Seon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.409-418
    • /
    • 2011
  • Objectives: The purpose of this study was to compare the microshear bond strength (${\mu}$SBS) and bonding interfaces of two-step total-etching and self-etching adhesive systems to three etch types of dentin either the acid etched, laser etched or laser and acid etched. Materials and Methods: The occlusal dentinal surfaces of thirty human molars were used. They were divided into six groups: group 1, 37% $H_3PO_4$ + Single Bond 2 (3M ESPE); group 2, Er:YAG laser (KEY Laser 3, KaVo) + Single Bond 2; group 3, Er:YAG laser + 37% $H_3PO_4$ + Single Bond 2; group 4, Clearfil SE Primer + Bond (Kuraray); group 5, Er:YAG laser + Clearfil SE Bond; group 6, Er:YAG laser + Clearfil SE Primer + Bond. The samples were subjected to ${\mu}$SBS testing 24 hr after bonding. Also scanning microscopic evaluations were made on the resin-dentin interfaces of six specimens. Results: The ${\mu}$SBS of group 2 was significantly lower than that of groups 1 and 3 in Single Bond 2 (p < 0.05). There were significant differences among the uSBS of groups 4, 5, and 6 in Clearfil SE Bond (p < 0.05). Very short and slender resin tags were observed in groups 2 and 5. Long and slender resin tags and lateral branches of tags were observed in groups 3 and 6. Conclusions: Treatment of dentin surface using phosphoric acid or self-etching primer improved the adhesion of Er:YAG lased dentin.

The Level of Diabetes Management of Agriculture, Forestry, and Fishery Workers (농림어업인의 당뇨병 관리 수준)

  • Oh, Gyung-Jae;Lee, Young-Hoon
    • Journal of agricultural medicine and community health
    • /
    • v.42 no.3
    • /
    • pp.119-131
    • /
    • 2017
  • Objectives: The purpose of this study was to compare the diabetic management indicators between agriculture, forestry, and fishery workers (AFF) and other occupational adults (non-AFF) in community-dwelling diabetes. Methods: The study population consisted of 22,127 diabetic population ${\geq}19years$ who participated in the 2015 Community Health Survey. Chi-square test and logistic regression analysis was used to compare the diabetic management indicators between AFF and non-AFF. Socioeconomic characteristics such as age, gender, education level, monthly household income, National Basic Livelihood Security status, and marital status was sequentially adjusted. Results: Among total diabetic population, 3,712 people (16.8%) was AFF and 18,415 people (83.2%) was non-AFF. The fully-adjusted odds ratio [OR] (95% confidence interval [CI]) of current non-medical treatment (0.72, 0.66-0.79), measurement of hemoglobin A1c (0.61, 0.55-0.67), screening for diabetic retinopathy (0.76, 0.70-0.83), screening for diabetic nephropathy (0.75, 0.70-0.81), non-alcoholic or moderate drinking (0.70, 0.64-0.78), nutrition label reading (0.83, 0.71-0.98), low salt preference (0.85, 0.78-0.93), dental examination (0.60, 0.54-0.66), scaling experience (0.84, 0.77-0.93), regular toothbrushing (0.66, 0.58-0.76), and diabetes management education (0.84, 0.77-0.92) was significantly lower in AFF compared to non-AFF. In contrast, the fully-adjusted OR (95% CI) of AFF's low stress level (1.39, 1.26-1.52) and adequate sleep duration (1.22, 1.13-1.32) was significantly higher than non-AFF, which are better indicators of diabetic management in AFF. Conclusions: Overall, the level of diabetes management of AFF was not as good as that of non-AFF. In order to improve the level of diabetes management of AFF, a delicate diabetes intervention strategy considering the occupational characteristics of AFF will be needed.

Comparison of Bite Forces between Pre- and Post-Treatment in Patients with Temporomandibular Disorders (측두하악장애 환자의 치료 전후 교합력 비교)

  • Lee, Sang-Il;Kim, Ki-Suk
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.2
    • /
    • pp.211-218
    • /
    • 2007
  • The purpose of this study was to compare the maximum bite forces between pre- and post-treatment related to specific diagnostic groups of TMD including masticatory muscle disorder (MMD), disc derangement (DD), joint inflammation (JI) and osteoarthritis (OA). Bite force between pre- and post-treatment was compared in 36 patients with unilateral TMD, successfully-managed in the Department of Oral Medicine, Dankook University Dental Hospital, for this study. The ratio of men to women was 7:29 and their mean age of $28.1{\pm}13.7$ years. The patients were categorized, through clinical and radiographic examination, into aforementioned 4 groups; MMD (N=18), DD (N=6), JI (N=5) and OA (N=7). The maximum bite force measurements were done at the antagonizing canines and 1st molars using a bite force recorder. Paired t-test, ANOVA, Multiple Comparison t-tests were used for statistical analysis. The results of this study showed that the maximum bite force before treatment increased after TMD treatment, which was noticeable at the canines (p=0.001 and p=0.000 for the affected and unaffected sides, respectively). In comparison related to the diagnostic groups of TMD, patients with osteoarthritis of TMJ exhibited the lowest strength while those with inflammatory disorder of TMJ had the highest strength on the affected sides. Increase of bite force after treatment was also found in each group. Significant difference between pre- and post-treatment was found at canines on the affected sides in MMD (p=0.045) and DD groups (p=0.009) while on the unaffected sides in OA group (p=0.003). Conclusively, the reduced bite force due to TMD could be recovered by conservative TMD treatment and that the difference of bite forces between pre- and post-treatment was noticeable at the canines.

Effect of Tightening Torque on Abutment-Fixture Joint Stability using 3-Dimensional Finite Element Analysis (임플란트 지대주나사의 조임회전력이 연결부 안정성에 미치는 영향에 관한 3차원 유한요소해석 연구)

  • Eom, Tae-Gwan;Suh, Seung-Woo;Jeon, Gyeo-Rok;Shin, Jung-Wook;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2009
  • Statement of problem: Loosening or fracture of the abutment screw is one of the common problems related to the dental implant. Generally, in order to make the screw joint stable, the preload generated by tightening torque needs to be increased within the elastic limit of the screw. However, additional tensile forces can produce the plastic deformation of abutment screw when functional loads are superimposed on preload stresses, and they can elicit loosening or fracture of the abutment screw. Therefore, it is necessary to find the optimum tightening torque that maximizes a fatigue life and simultaneously offer a reasonable degree of protection against loosening. Purpose: The purpose of this study was to present the influence of tightening torque on the implant-abutment screw joint stability with the 3 dimensional finite element analysis. Material and methods: In this study, the finite element model of the implant system with external butt joint connection was designed and verified by comparison with additional theoretical and experimental results. Four different amount of tightening torques(10, 20, 30 and 40 Ncm) and the external loading(250 N, $30^{\circ}$) were applied to the model, and the equivalent stress distributions and the gap distances were calculated according to each tightening torque and the result was analyzed. Results: Within the limitation of this study, the following results were drawn; 1) There was the proportional relation between the tightening torque and the preload. 2) In case of applying only the tightening torque, the maximum stress was found at the screw neck. 3) The maximum stress was also shown at the screw neck under the external loading condition. However in case of applying 10 Ncm tightening torque, it was found at the undersurface of the screw head. 4) The joint opening was observed under the external loading in case of applying 10 Ncm and 20 Ncm of tightening torque. 5) When the tightening torque was applied at 40 Ncm, under the external loading the maximum stress exceeded the allowable stress value of the titanium alloy. Conclusion: Implant abutment screw must have a proper tightening torque that will be able to maintain joint stability of fixture and abutment.

Influencing factors on the final color of laminate veneer restorations with various IPS Empress Esthetic$^{(R)}$ ingots (다양한 IPS Empress Esthetic$^{(R)}$ ingot으로 제작한 laminate veneer의 최종 색조에 대한 영향)

  • Yang, Mi-Seon;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.308-315
    • /
    • 2011
  • Purpose: The purpose of this study was to colorimetrically evaluate the masking effect of different opacity of ingots on the final shade of IPS Empress Esthetic$^{(R)}$ laminate veneer restorations using the CIE $L^*a^*b^*$ system. Materials and methods: Six porcelain disks of IPS Empress Esthetic$^{(R)}$ system (translucency: E 01, E 03, E 0C-1, E TC-1, E TC-2, E TC-3) were fabricated with 7 mm in diameter and 0.6 mm in thickness. Six extracted human incisors (shade: A1, A3, A4, B2, B3, C3) were used as the abutment specimens. The incisors were prepared using a diamond wheel and made with a flat labial surface on the middle 1/3. For each combination of different shades of abutments and copings, the change in color was measured with a colorimeter. CIE $L^*a^*b^*$ coordinates were recorded for each specimen. Color differences (${\Delta}E$) were calculated. Descriptive statistical analysis was done. Results: ${\Delta}E$ values were significantly affected by coping translucency and abutment shade (P<.05). The color differences (${\Delta}E$) of laminate veneers among abutments with A3, B3, C3, and A4 shade were mostly below 2.7 which was within the clinically acceptable range, while color differences between A4 and B2, A3 and B2, and A1 and A4 showed more than 2.7. Conclusion: The final color of IPS Empress Esthetic$^{(R)}$ laminate veneers were significantly influenced by translucency of the coping and shade of abutment teeth. The large value difference of abutment teeth limited the masking ability by laminate veneers.

Histomorphometric Study of Sinus Bone Graft using Various Graft Material (다양한 골이식재료를 이용한 상악동 골이식 4개월 후 조직형태계측학적 평가)

  • Lee, Ji-Young;Kim, Young-Kyun;Kim, Su-Gwan;Lim, Sung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • The aim of this study was to evaluate histomorphometrically and compare the efficiency of various bone graft material and autogenous tooth bone graft material which were used in sinus bone graft procedure. Subjects were the 24 patients who had treated with sinus bone graft using lateral approach from October 2007 to September 2009 at SNUBH. The average age was $52.51{\pm}11.86$ years. All cases was taken after 4month of procedure and divided into 3 groups according to bone graft material. Group 1: autogenous tooth bone graft material, Group 2: OrthoblastII(integra lifescience corp. Irvine, US)+Biocera(Osscotec, seoul, korea), group 3: DBX(Synthes, USA)+BioOss(Geistlich Pharm AG, Wolhusen, Switzerland). Total 37 implant placement area were included and evaluated(7 in group 1, 10 in group 2, 20 in group 3). Evaluation of new bone formation, ratio of woven bone to lamellar bone, ratio of new bone to graft material were performed on each tissue section. Kruskal-Wallis test was used for statistical analysis(SPSS Ver. 12.0, USA). New bone formation were $52.5{\pm}10.7%$ in group 1, $52.0{\pm}23.4%$ in group 2, $51.0{\pm}18.3%$ in group 3. There were no statistical significant differences between each groups. Ratio of woven bone to lamella bone were $82.8{\pm}15.3%$ in group 1, $36.7{\pm}59.3%$ in group 2, $31.0{\pm} 51.2%$ in group 3. Ratio of new bone to graft material were $81.3{\pm}10.4%$ in group 1, $72.5{\pm}28.8%$ in group 2, $80.3{\pm}24.0%$ in group 3. After 4 month of healing period, all group showed favorable new bone formation and around graft material and implant. Within limitation of our study, it is suggested that autogenous tooth bone graft material might be used as novel bone graft material for sinus bone graft.

Effects of the color components of light-cured composite resin before and after polymerization on degree of conversion and flexural strength (광중합형 복합레진의 중합 전, 후의 색 성분이 중합률과 굴곡강도에 미치는 영향)

  • Yoo, Ji-A;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.324-335
    • /
    • 2011
  • Objectives: This study investigated the effects of the color components of light-cured composite resin before and after polymerization on degree of conversion (DC) and biaxial flexural strength (FS). Materials and Methods: Four enamel shades (A1, A2, A3, A4) and two dentin shades (A2O, A3O) of Premisa (Kerr Co.) and Denfil (Vericom Co.) were evaluated on their CIE $L^*,\;a^*,\;b^*$ color components using the spectrophotometer before curing, after curing and at 7 day. The DC of same specimens were measured with Near-infrared spectrometer (Nexus, Thermo Nicolet Co.) at 2 hr after cure and at 7 day. Finally, the FS was obtained after all the other measurements were completed at 7 day. The correlations between each color component and DC and FS were evaluated. Results: The light-curing of composite resin resulted in color changes of Premisa in red-blue direction and Denfil in green-blue direction. The DC and FS were affected by product, time and shade (3-way ANOVA, p < 0.05) and product and shade (2-way ANOVA, p < 0.05), respectively. Premisa only showed a significant correlation between the DC and CIE $a^*$ component - before and after polymerization (Pearson product moment correlation, p < 0.05). The FS of Premisa showed significant negative correlations with CIE $a^*$ and CIE $b^*$ components. Conclusions: The DC and FS of the light-curing composite resin were affected by the color components of the material before and after polymerization.

EFFECT OF BENZALKONIUM CHLORIDE ON DENTIN BONDING WITH NTG-GMA/BPDM AND DSDM SYSTEM (Benzalkonium Chloride가 NTG-GMA/BPDM계 및 DSDM계 상아질접착제의 접착성능에 미치는 영향)

  • Shin, Il;Park, Jin-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.699-720
    • /
    • 1995
  • This study was conducted to evaluate the effect of benzalkonium chloride solution as a wetting agent instead of water on dentin bonding with NTG-GMA/BPDM system (All-bond 2, Bisco.) and DSDM system (Aelitebond, Bisco.). Benzalkonium chloride solution is a chemical disinfectant widely used in medical and dental clinics for preoperative preparation of skin and mucosa due to its strong effect of cationic surface active detergent. Eighty freshly extracted bovine lower incisor were grinded labially to expose flat dentin surface, and then were acid-etched with 10 % phosphoric acid for 15 second, water-rinsed, and dried for 10 second with air syringe. The specimens were randomly divided into 8 groups of 10 teeth. The specimens of control group were remoistured with water and the specimens of experimental groups were remoistured with 0.1 %, 0.5 %, and 1.0 % benzalkonium chloride solution respectively. And then, the Aelitefil composite resin was bonded to the pretreated surface of the specimens by use of All-bond 2 dentin bonding system or Aelitebond dentin bonding system in equal number of the specimens. The bonded specimens were stored in $37^{\circ}C$ distilled water for 24 hours, then the tensile bond strength was measured, the mode of failure was observed, the fractured dentin surface were examined under scanning electron microscopy, and FT-IR spectroscopy was taken for the purpose of investigating the changes of the dentin surface pretreated with benzal konium chloride solution followed by each primer of the dentin bonding systems. The results were as follows : In the group of bonding with NTG-GMA/BPDM dentin bonding agent(All-bond 2), higher tensile bond strength was only seen in the experimental group remoistured with 0.1 % benzal konium chloride solution than that in water-remoistured control group(p<0.05). In the group of bonding with DSDM dentin bonding agent (Aelitebond), no significant differences were seen between the control and each one of the experimental group(p<0.05). Higher tensile bond strength were seen in NTG-GMAIBPDM dentin bonding agent group than in DSDM dentin bonding agent group regardless of remoistur ization with benzal konium chloride solution. On the examination of failure mode, cohesive and mixed failure were predominantly seen in the group of bonding with NTG-GMAIBPDM dentin bonding agent, while adhesive failure was predominantly seen in the group of bonding with DSDM dentin bonding agent. On SEM examination of fractured surfaces, no differences of findings of primed dentin surface between the groups with and without remoisturization with benzal konium chloride solution. FT-IR spectroscopy taken from the control and the experimental group reve::.led that some higher absorbance derived from the primers binding to dentin surface was seen at the group pretreated with 0.1 % benzal konium chloride solution than at the control group of remoisturizing with water.

  • PDF