Al-Shehri, Eman Z.;Al-Zain, Afnan O.;Sabrah, Alaa H.;Al-Angari, Sarah S.;Dehailan, Laila Al;Eckert, George J.;Ozcan, Mutlu;Platt, Jeffrey A.;Bottino, Marco C.
Restorative Dentistry and Endodontics
/
제42권3호
/
pp.206-215
/
2017
Objectives: To determine the combined effect of fatigue cyclic loading and thermocycling (CLTC) on the shear bond strength (SBS) of a resin cement to zirconia surfaces that were previously air-abraded with aluminum oxide ($Al_2O_3$) particles at different pressures. Materials and Methods: Seventy-two cuboid zirconia specimens were prepared and randomly assigned to 3 groups according to the air-abrasion pressures (1, 2, and 2.8 bar), and each group was further divided into 2 groups depending on aging parameters (n = 12). Panavia F 2.0 was placed on pre-conditioned zirconia surfaces, and SBS testing was performed either after 24 hours or 10,000 fatigue cycles (cyclic loading) and 5,000 thermocycles. Non-contact profilometry was used to measure surface roughness. Failure modes were evaluated under optical and scanning electron microscopy. The data were analyzed using 2-way analysis of variance and ${\chi}^2$ tests (${\alpha}=0.05$). Results: The 2.8 bar group showed significantly higher surface roughness compared to the 1 bar group (p < 0.05). The interaction between pressure and time/cycling was not significant on SBS, and pressure did not have a significant effect either. SBS was significantly higher (p = 0.006) for 24 hours storage compared to CLTC. The 2 bar-CLTC group presented significantly higher percentage of pre-test failure during fatigue compared to the other groups. Mixed-failure mode was more frequent than adhesive failure. Conclusions: CLTC significantly decreased the SBS values regardless of the air-abrasion pressure used.
Objectives: This study aimed to measure the water sorption / solubility of Biodentine, composite resin and glass ionomer cement. Materials and Methods: The materials used in this study were Biodentine(BD), Filtek Z250(FZ) and Ketac Molar(KM). Twenty disc-shaped specimens of each material were prepared of 6mm diameter and 1mm thickness. All specimens were desiccated for 24 hours and weighed(m1). After then, They were immersed in distilled water and stored at $37^{\circ}C$. 1 week later, They were washed with running water, wiped with absorbent paper and weighed(m2). Finally, They were dried for 24 hours and weighed(m3). Water sorption and solubility, net water uptake were calculated. Results: KM and BD showed high water sorption than FZ(P<0.05). KM and BD exhibited similar water sorption(P<0.05). BD exhibited high solubility than KM(P=0.012). BD exhibited high net water uptake than FZ(P=0.008). Conclusion: Biodentine showed higher water sorption, solubility and net water uptake than Filtek Z250 and Ketac Molar. Within limitation of this study, it is not recommended to use Biodentine for permanent restoration.
본 연구에서는 지르코니아의 새로운 표면처리 방법이 레진 시멘트와의 전단결합강도에 미치는 영향을 알아보고자 하였다. 지르코니아 표면처리 방법 따라 5개의 그룹으로 분류하였다: 표면처리 미시행한 군(CON군), 100℃에서 9% 불산에 10분간 노출시킨 군(HF군), 15% 지르코니아 슬러리를 적용한 군(ZS15군), 30% 지르코니아 슬러리를 적용한 군(ZS30군), 50% 지르코니아 슬러리를 적용한 군(ZS50군). 표면처리한 지르코니아 위에 레진 시멘트를 적용하였고, 열 순환 처리 후 지르코니아와 레진 시멘트 간의 전단결합강도를 측정하였다. 전단결합강도에 대한 통계 방법으로 Kruskal-Wallis test와 Mann-Whitney U test 및 Boneferroni correction를 사용하였다(α=.05/10=.005). 지르코니아 슬러리를 적용한 군은 CON군과 HF군에 비해 높은 전단결합강도를 보였다(p<.05/10=.005). 지르코니아 슬러리를 이용한 표면처리 방법은 레진 시멘트와 지르코니아 간의 전단결합강도를 증대시킴을 확인하였다. 본 연구 결과, 새로운 표면처리 방법은 지르코니아가 지닌 접착의 한계점을 보완하고 개선함으로써 지르코니아의 보다 다양한 임상적 적용 가능성을 기대할 수 있을 것으로 사료된다.
본 연구는 상아질 접착제와 레진 시멘트의 적합성 여부를 알아보고자 시행하였다. 발거한 제3대구치의 상아질 표면을 노출시킨 후 Tescera ATL 복합레진 시편을 상아질 접착제 [All Bond 2 (Bisco), Clearfil SE Bond (Kuraray), Adper Prompt L-POP (3M), One-Up Bond F (Tokuyama)]와 레진시멘트 [Choice (Bisco), Panavia F (Kuraray), RelyX ARC (3M), Bistite II DC (Tokuyama)]로 접착하고 미세인장 결합강도 및 주사전자 현미경 관찰을 시행한 결론은 다음과 같다. 1. Clearfil SE Bond와 All-Bond 2가 Prompt L-Pop과 One-Up Bond F 보다 높은 미세인장 결합강도를 보였다(p<0.05). 2. Clearfil SE Bond와 All-Bond 2 사용시 1-step 상아질 접착제보다 혼성층이 두껍고 레진 tag가 길었다.
The study was designed to establish a more nearly quantitative method for assessing the marginal leakage of dental restorations. 27 Class V cavities with $45^{\circ}$ bevel joint were prepared and classified into 2 groups. One group was filled with Scotchbond and silux. The other group was filled with glass ionomer cement, Scotchbond and silux. After finishing, all specimens were subjected manually to 100 thermal cycles at $0^{\circ}C$ and $100^{\circ}C$ water-bath. They were soaked in a samarium nitrate solution for 3 hours, irradiated with flux of $6{\times}10^{12}$ neutrons/$cm^2$/sec for 11 hours, cooled for 200 hours, counted with the HPGE detector and the tracer uptake was determined by comparison with a standard of samarium (10 ${\mu}g$). The following results were obtained. 1. Both of the two groups showed a considerable amounts of marginal leakage. 2. The group filled without glass ionomer cement base showed more marginal leakage than the group filled with glass ionomer cement base. 3. Neutron Activation Analysis produced a good quantitative method to measure the marginal leakage and samarium was appropriate to measure the marginal leakage of resin restorations using neutron activation analysis.
Objectives: This study aimed to evaluate the interface between a calcium silicate cement (CSC), Biodentine and dental adhesives in terms of sealing ability. Materials and Methods: Microleakage test: 160 standardized class II cavities were prepared on 80 extracted human molars. The cavities were filled with Biodentine and then divided into 2 experimental groups according to the time of restoration: composite resin obturation 15 minutes after Biodentine handling (D0); restoration after 7 days (D7). Each group was then divided into 8 subgroups (n = 5) according to the adhesive system used: etch-and-rinse adhesive (Prime & Bond); self-etch adhesive 2 steps (Optibond XTR and Clearfil SE Bond); self-etch adhesive 1 step (Xeno III, G-aenial Bond, and Clearfil Tri-S Bond); and universal used as etch-and-rinse or self-etch (ScotchBond Universal ER or SE). After thermocycling, the teeth were immersed in a silver nitrate solution, stained, longitudinally sectioned, and the Biodentine/adhesive percolation was quantified. Scanning electron microscopic observations: Biodentine/adhesive interfaces were observed. Results: A tendency towards less microleakage was observed when Biodentine was etched (2.47%) and when restorations were done without delay (D0: 4.31%, D7: 6.78%), but this was not significant. The adhesives containing 10-methacryloyloxydecyl dihydrogen phosphate monomer showed the most stable results at both times studied. All Biodentine/adhesive interfaces were homogeneous and regular. Conclusions: The good sealing of the CSC/adhesive interface is not a function of the system adhesive family used or the cement maturation before restoration. Biodentine can be used as a dentine substitute.
목적: 중합방법 및 측정시기에 따른 여러 이중중합 레진 시멘트의 기계적 성질인 압축강도와 간접인장강도를 비교 평가하는 것이다. 연구 재료 및 방법: 1개의 레진강화형 글래스아이오노머 시멘트인 FujiCEM 2, 2개의 전통적인 이중중합 레진 시멘트인 RelyX ARC와 Multilink N, 2개의 이중중합 자가접착 레진 시멘트인 RelyX U200과 G-CEM LinkAce를 사용하였다. 제조사의 지시에 따라 시멘트를 혼합하여 압축강도와 간접인장강도 측정을 위한 시편을 제작하였다. 중합방법 및 측정시기의 영향을 평가하기 위해 시멘트에 따라 4가지 실험 조건으로 나눴고, 만능시험기로 압축강도와 간접인장강도 측정하였다. 각각의 강도 값을 계산 후 통계처리 하였다. 결과: 압축강도에서는 RelyX ARC의 광중합과 Multilink N의 광중합, 간접인장강도에서는 RelyX ARC의 광중합을 제외하고 모든 중합방법에서 24시간 뒤 측정된 강도가 즉시 측정한 강도보다 더 높은 값을 보여주었다. FujiCEM 2는 시멘트간 비교에서 가장 낮은 강도 값을 보였다(P < 0.05). 결론: 치과용 시멘트 중에서 최근 출시된 이중중합 자가접착 레진 시멘트는 기존의 레진 시멘트와 비교시 제품별로 차이가 있었으나, 압축강도와 간접인장강도에서는 유의한 차이를 보이지 않았다.
This paper reviewed the following subheadings and a few selected references in each section were discussed: ${\cdot}$ Sealant placed over caries; is it possible? Initial caries which is not sticky during proving is possible to be placed with sealants. ${\cdot}$ Prophylaxis of fissure; which method is most effective? Mechanical preparation with fissurotomy or resin polishing bur is one of the most effective method to clean the pit and fissure. ${\cdot}$ Glassionomer cement as a sealant; GIC, wheather it released fluoride or not, cannot be as cost-effective as resin-based sealants. ${\cdot}$ Sealant products; Color(white vs opaque), fluoride(containing vs not), filler component(filled vs non-filled) do not influenced the quality and retention of sealants. ${\cdot}$ Use of intermediate bonding agent to improve retention; Intermediate bonding may increase the retention rate of sealants ${\cdot}$ Penetration method of sealants; Several methods including waiting before light curing are recommended.
연구 목적: 본 연구의 목적은 다이의 수렴각과 치관길이의 차이와 시멘트 종류의 차이가 전부주조관의 유지력에 미치는 영향을 비교한 것이다. 연구 재료 및 방법: 치관 길이 5 mm와 10 mm의 금속다이를 각각 5, 10, 15, 25도의 수렴각을 갖도록 제작한 후 전부주조관을 치과용 시멘트 중, 인산아연 시멘트(Fleck's Zinc Phosphate Cement, Mizzy Co., Cherry Hill, NJ, USA), 레진-변형 글래스 아이오노머 시멘트(Vitremer, 3M Dental Products, St, Paul, MN, USA), 레진 시멘트(Panavia 21, Kuraray Co., Osaka, Japan)로 합착하고 500회 thermocycling을 시도한 후, Instron Universal Testing Machine (Instron Corp., Canton, MA, USA)에 장착시켜, 인장력을 가하여 전부주조금관이 분리될 때 까지 인장력을 측정하여 분리되는 순간의 최대하중값(N)을 측정, 비교하였다. 통계분석은 측정된 각 군간 유지력의 상호관계를 알아보기 위하여 one-way 및 two-way ANOVA를 시행하였고 동일 길이를 가진 시멘트 군 사이에서의 수렴각 차이에 따른 영향, 다이 길이 증가에 따른 영향 및 유지력 차이를 검정하기 위해 t-test를, 수렴각 증가 에 따른 유의성을 살펴 보기 위해서는 Tukey's HSD test를 시행하였다(${\alpha}$=0.05). 결과: 동일 수렴각에서 평균 유지력은 레진 시멘트, 인산아연 시멘트, 레진-변형 글래스 아이오노머 시멘트 순으로 높게 나타났으며 모든 시멘트에서 수렴각의 증가에 따 라서 평균 유지력은 유의차를 보이면서 감소하였다(P<.05). 동일 수렴각에서 10 mm 실험군은 다이 길이 5 mm 실험군과 비교해보았을 때 길이 증가에 따른 유지력의 증가가 통계학적으로 유의차를 나타내면서 증가된 결과를 보였다. 5 mm 실험군에서 유지력은 수렴각의 변화와 시멘트의 종류, 수렴각과 시멘트의 상호영향(interaction)에서 모두 유의성 있는 차이를 보였다(P=.001). 각 시멘트 군에서의 유지력은 10 mm 길이 금속 다이의 수렴각이 증가할수록 유의한 차이를 보이면서 감소한 것으로 나타났다 (P=.0001). 결론: 임상에서 사용되고 있는 특정 치과용 시멘트의 적용시 유지력은 지대치의 기하학적 형태에 영향을 받고 있으며 서로 다른 치관 길이와 수렴각을 가지는 경우 유지 력 증가를 위해 시멘트 선택에 있어 주의가 요망된다.
연구 목적: 본 연구의 목적은 중합 과정 중 치과용 레진 시멘트의 점탄성 성질의 변화를 관찰하기 위한 것이다. 연구 재료 및 방법: 6 종류의 레진시멘트(Clearfil SA luting, Panavia F 2.0, Zirconite, Variolink N, RelyX Unicem clicker, RelyX U200)가 이번 실험에 사용되었다. AR1500 stress controlled rheometer를 이용해 $32^{\circ}C$에서 동적 시간 경과 시험(dynamic oscillation time sweep test)이 시행되었다. 각각의 레진시멘트의 전단 저장 계수(G'), 전단 손실 계수(G"), 손실 탄젠트(tan ${\delta}$), 변위량을 20분 동안 3번씩 반복 측정하였다. 측정 결과는 일원배치분석 및 Tukey's hoc test로 사후 검정을 시행하였다(${\alpha}$=0.05). 결과: 모든 레진 시멘트는 혼합 후 시간에 따라 G' 값이 증가하였고, 최종적으로 안정상태에 도달하였다. 실험 종료 시점에서 RelyX U200은 가장 높은 G'값을 나타냈고, RelyX Unicem (clicker type)과 Variolink N이 가장 낮은 G'값을 나타냈다. Tan ${\delta}$와 변위량은 일정 수준의 값을 유지하다가 G'이 증가하기 시작하는 시점에서 0에 도달하였다. 이는 변위량이 0에 도달하는 지점과 거의 일치하였으며, 그 시간은 6분 내외였다. 결론: 본 연구에서 RelyX U200은 다른 레진 시멘트와 비교하여 가장 오랜 시간 동안 소성을 유지하고, 경화 완료 후 가장 높은 강도(rigidity)를 보였다. 따라서 여러 개의 보철물을 동시에 합착해야 하는 경우에 RelyX U200이 유용할 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.