• Title/Summary/Keyword: Dental marginal adaptation

Search Result 53, Processing Time 0.021 seconds

Comparison of the Marginal and Internal Fit on the Cast and CAD-CAM Cores (주조에 의한 Core와 CAD-CAM에 의한 Core의 적합도 비교평가)

  • Han, Man-So;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.368-374
    • /
    • 2012
  • Dental CAD (computer-aided design)/CAM (computer-aided manufacturing) systems facilitate the use of zirconia core for all-ceramic crown. The purpose of this study was to evaluate the marginal and internal fit of zirconia core fabricated using a dental CAD/CAM system and to compare the fit of metal cores by a conventional method. Ten identical cases of single coping study models (abutment of teeth 11) were manufactured and scanned. Ten zirconia cores were fabricated using dental CAD/CAM system. An experienced dental technician fabricated 10 samples of metal cores for the control group using the lost wax technique. Marginal and internal fit was measured by the silicone replica technique. Fit was measured with magnification of 160 using a digital Microscope. Margin, rounded chamfer, axial wall and incisal fits were measured for comparison. T-test of independent sample for statistical analysis was executed with SPSS 12.0 for Windows (SPSS Inc., Chicago, IL, USA) (${\alpha}$=0.05). The mean (SD) for marginal, rounded chamfer, axial wall and incisal were: $97.0\;(25.3){\mu}m$, $104.0\;(22.0){\mu}m$, $59.6\;(21.4){\mu}m$ and $124.8\;(33.3){\mu}m$ for the zirconia core group, and $785.2\;(18.4){\mu}m$, $83.8\;(15.1){\mu}m$, $42.7\;(9.6){\mu}m$ and $83.4\;(14.4){\mu}m$ for the metal core group. T-test showed significant differences between groups for margin (p<.001), rounded chamfer (p<.001), axial wall (p<.001) and incisal (p<.001). But zirconia core group observed that the marginal and internal fit values in the present study were within clinically acceptable range.

The influence of different base materials on marginal adaptation of direct class I composite resin restorations

  • Cho, Yong-Sik;Park, Sung-Ho
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.619-619
    • /
    • 2003
  • This study was intended to evaluate the influence of different base materials on the marginal integrity of posterior direct composite resin restorations. Large conventional butt-joint MOD cavity preparations, with margins in enamel and dentin, were prepared in vitro in 24 extracted human mandibular molars and randomly divided into four equal groups. One of three base materials(RMGI, compomer, flowable resin) was placed on the pulpal floors, of the teeth of the groups. One group of teeth, which served as the control group, was not given any base mterial.(중략)

  • PDF

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.

Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions

  • Franklin Guillermo Vargas-Corral;Americo Ernesto Vargas-Corral;Miguel Angel Rodríguez Valverde;Manuel Bravo;Juan Ignacio Rosales Leal
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2024
  • PURPOSE. The aim of this stuldy was to compare the clinical marginal fit of CAD-CAM inlays obtained from intraoral digital impression or addition silicone impression techniques. MATERIALS AND METHODS. The study included 31 inlays for prosthodontics purposes of 31 patients: 15 based on intraoral digital impressions (DI group); and 16 based on a conventional impression technique (CI group). Inlays included occlusal and a non-occlusal surface. Inlays were milled in ceramic. The inlay-teeth interface was replicated by placing each inlay in its corresponding uncemented clinical preparation and taking interface impressions with silicone material from occlusal and free surfaces. Interface analysis was made using white light confocal microscopy (WLCM) (scanning area: 694 × 510 ㎛2) from the impression samples. The gap size and the inlay overextension were measured from the microscopy topographies. For analytical purposes (i.e., 95-%-confidence intervals calculations and P-value calculations), the procedure REGRESS in SUDAAN was used to account for clustering (i.e., multiple measurements). For p-value calculation, the log transformation of the dependent variables was used to normalize the distributions. RESULTS. Marginal fit values for occlusal and free surfaces were affected by the type of impression. There were no differences between surfaces (occlusal vs. free). Gap obtained for DI group was 164 ± 84 ㎛ and that for CI group was 209 ± 104 ㎛, and there were statistical differences between them (p = .041). Mean overextension values were 60 ± 59 ㎛ for DI group and 67 ± 73 ㎛ for CI group, and there were no differences between then (p = .553). CONCLUSION. Digital impression achieved inlays with higher clinical marginal fit and performed better than the conventional silicone materials.

Microhybrid versus nanofill composite in combination with a three step etch and rinse adhesive in occlusal cavities: five year results

  • Tuncer, Safa;Demirci, Mustafa;Oztas, Evren;Tekce, Neslihan;Uysal, Omer
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.253-263
    • /
    • 2017
  • Objectives: The aim of the study was to evaluate the 5-year clinical performance of occlusal carious restorations using nanofill and microhybrid composites, in combination with 3-step etch-and-rinse adhesives, in patients who were going to commence orthodontic treatment. Materials and Methods: A total of 118 restorations for occlusal caries were conducted prior to orthodontic treatment. Occlusal restorations were performed both with Filtek Supreme XT (3M ESPE) and Filtek Z250 (3M ESPE) before beginning orthodontic treatment with fixed orthodontic bands. Restorations were clinically evaluated at baseline and at 1, 2, 3, 4, and 5-year recalls. Results: None of the microhybrid (Filtek Z250) and nanofill (Filtek Supreme XT) composite restorations was clinically unacceptable with respect to color match, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, or surface texture. A 100% success rate was recorded for both composite materials. There were no statistically significant differences in any of the clinical evaluation criteria between Filtek Z250 and Filtek Supreme XT restorations for each evaluation period. Conclusions: The composite restorations showed promising clinical results relating to color matching, marginal discoloration, wear or loss of anatomical form, recurrent caries, marginal adaptation, and surface texture at the end of the 5-year evaluation period.

The effect of heat and press-on-metal technique on marginal fit of metal-ceramic crown (열가압성형도재의 사용이 금속도재관 치경부 변연적합도에 미치는 영향)

  • Kim, Ji-Eun;Kim, Se-Yeon;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.2
    • /
    • pp.90-96
    • /
    • 2014
  • Purpose: The purpose of this study is to see what impact the heat and press-on-metal technique has on the marginal fit of metal ceramic crown. Materials and methods: Prior to the experiment, 4 metal master models were prepared. Each model has margin of chamfer, margin of heavy chamfer, margin of shoulder with bevel and margin of shoulder (collarless). Additionally, 10 crowns were made for each margin, total of 40 crowns. Marginal discrepancy between the master model and crown was observed at ${\times}100$ microscopic magnification in two states; in coping state and upon completion of making metal ceramic crown. Data analysis was performed using paired t-test along with one-way ANOVA and Duncan multiple comparison test. Results: After analyzing mean and standard deviation of marginal discrepancy, it was confirmed that marginal discrepancies were within the clinical permitted range for all states; in coping state and upon completion of making metal ceramic crown. For the chamfer group, a significant increase in marginal discrepancy upon completion of making metal ceramic crown was observed compared to the heavy chamfer group. Also, a marginal discrepancy of porcelain margin in shoulder group was significantly less than the marginal discrepancy of metal margin in chamfer and shoulder group. Conclusion: From the test result, one can conclude that marginal fit of metal ceramic crown built with heat and press-on-metal technique is not significantly different from marginal fit of metal ceramic crown built with traditional technique. And along with efficiency of this system, heat and press-on-metal technique is considered in clinic.

An Evaluation Validity of the Silicone Replica Technique at Measurement on Fit of Fixed Dental Prostheses (고정성 보철물의 적합도 측정 시 사용하는 실리콘 복제본 기술의 정확도 평가)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.566-571
    • /
    • 2012
  • Marginal and internal fit are very important factor for the clinical long-term success of fixed dental prostheses (FDPs). A variety of methods have been applied to the measuring marginal and internal fit of FDPs. The purpose of this study was to compare the marginal and internal fit of 2 different measuring methods silicone replica technique [SRT] and die cutting technique (DCT). SRT, the space between die and FDPs were filled with light-body silicone, then stabilized by medium-body silicone. DCT, the FDPs were cemented on definitive dies and embedded into epoxy. The silicone replicas and epoxies were sectioned mesio-distal and measured 4 locations (margin, rounded chamfer, axial, occlusal) and using a digital microscope at a magnification $\times$160. For the SRT the mean${\pm}$SDs fit (${\mu}m$) recorded were: margin $88.7{\pm}22.2$, rounded chamfer $90.6{\pm}25.0$, axial wall $61.5{\pm}21.8$, occlusal $134.9{\pm}30.8$. For the DCT the mean${\pm}$SDs fit (${\mu}m$) recorded were: margin $85.3{\pm}18.0$, rounded chamfer $85.4{\pm}24.7$, axial wall $62.0{\pm}21.3$, occlusal $131.7{\pm}30.5$. The mean${\pm}$SDs size (${\mu}m$) of SRT margin was $88.7{\pm}22.2$ and of DCT margin was $85.3{\pm}18.0$. There were no statistically significant difference (p<0.05) of the four parts between SRT and DCT. It is considered an appropriate case to use SRT at fit of FDPs.

Influence of the accuracy of abutment tooth preparation on the marginal adaptation of Co-Cr alloy copings fabricated with a selective laser sintering technology (지대치삭제의정확도가레이져신터링기술로제작된Co-Cr 코핑의변연적합도에미치는영향)

  • Kim, Seo-Rahng;Koak, Jai-Young;Heo, Seong-Joo;Kim, Seong-Kyun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.337-344
    • /
    • 2015
  • Purpose: The purpose of present study is to examine the correlation between the accuracy of abutment preparation and the marginal adaptation of metal coping. With this view, this study compared the correlations regard to the three different manufacturing methods of selective laser sintering technique, milling and casting. Materials and methods: Two master models were made in a different way. First model with deep chamfer margin was prepared directly by a general clinician and the second model was designed by 3-D designing software program with the same abutment preparation principle and produced by computer aided manufacturing. 12 Co-Cr alloy copings were produced respectively with three different method; SLS system, CAD/CAM milling and conventional lost wax technique from each master model. The total 72 copings fully sit on the master model were stereoscopically evaluated at 40 points along the entire circumferential margin. Results: Significant differences in the absolute marginal discrepancies of Co- Cr copings from SLS system (P=.0231) and casting method (P<.0001) were shown between hand preparation model and computer designed model. However, no significant difference was found between the two model groups from milling method (P=.9962). Conclusion: Within the limitation of this study, the effect of the accuracy of abutment preparation on the marginal adaptation of Co-Cr coping is statistically significant in SLS system and casting group. The copings produced by SLS system exhibited the lowest marginal discrepancies among all groups, and the marginal gap of this method group was influenced by the accuracy of the abutment preparation.

In vitro evaluation methods on adaptation of fixed dental prosthesis (고정성 보철물의 적합도에 대한 실험적 평가방법)

  • Lee, Hyunho;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.63-70
    • /
    • 2017
  • Clinically, the fit of fixed prosthesis is an essential element for successful restoration. The fit of prosthesis is largely classified into marginal fit and internal fit, and various methods to assess these have been introduced including microscopic margin measurement, cross-sectional measurement, silicone replica technique, 3-dimensional scanning data superposition, weight technique and micro CT scanning. Thus, this study is aimed at proposing a more convenient and accurate measurement method of fits in a digital environment by comparatively analyzing the advantages and disadvantages of each known method based on existing literature.

Early complications and performance of 327 heat-pressed lithium disilicate crowns up to five years

  • Huettig, Fabian;Gehrke, Ulf Peter
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.194-200
    • /
    • 2016
  • PURPOSE. The prospective follow-up aimed to assess the performance of lithium disilicate crowns and clinical reasons of adverse events compromising survival and quality. MATERIALS AND METHODS. 58 patients were treated with 375 heat-pressed monolithic crowns, which were bonded with resin cement. Annual recalls up to five years included a complete dental examination as well as quality assessment using CDA-criteria. Any need for clinical intervention led to higher complication rate and any failure compromised the survival rate. Kaplan-Meier-method was applied to all crowns and a dataset containing one randomly selected crown from each patient. RESULTS. Due to drop-outs, 45 patients (31 females, 14 males) with the average age of 43 years (range = 17-73) who had 327 crowns (176 anterior, 151 posterior; 203 upper jaw, 124 lower jaw) were observed and evaluated for between 4 and 51 months (median = 28). Observation revealed 4 chippings, 3 losses of retention, 3 fractures, 3 secondary caries, 1 endodontic problem, and 1 tooth fracture. Four crowns had to be removed. Survival and complication rate was estimated 98.2% and 5.4% at 24 months, and 96.8% and 7.1% at 48 months. The complication rate was significantly higher for root canal treated teeth (12%, P<.01) at 24 months. At the last observation, over 90% of all crowns showed excellent ratings (CDA-rating Alfa) for color, marginal fit, and caries. CONCLUSION. Heat pressed lithium disilicate crowns showed an excellent performance. Besides a careful luting, dentists should be aware of patients' biological prerequisites (grade of caries, oral hygiene) to reach full success with these crowns.