• Title/Summary/Keyword: Dental impression

Search Result 345, Processing Time 0.026 seconds

Reliability and Accuracy of Digital Impression Obtained from CS-3500 Intraoral Scanner (CS-3500 구강 내 스캐너로 채득된 디지털 인상의 신뢰도 및 정확도 평가)

  • Kim, Sa-Hak;Kim, Jae-Hong;Kim, Chong-Kyen
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.673-678
    • /
    • 2015
  • The purpose of this study was to evaluate the reliability and accuracy of linear measurements in digital models compared to master model. A master model (ANKA-4; Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Four linear measurements were recorded between landmarks, directly on the master model and the digital models by a single examiner. Measurements were made with a digital caliper from manual model and with the software from the virtual models. The t-test for paired samples and intraclass correlation coefficient (ICC) were used for statistical analysis. The measurement of two methods showed good reliability. The mean differences between master and digital model were 0.06~0.12 mm. These in vitro studies show that accuracy and reliability of the digital impression is similar to that of the gold standard. Therefore digital impression was also considered to be a acceptable for placement clinically.

Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions (알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석)

  • Joo, Young-Hun;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.316-328
    • /
    • 2015
  • Purpose: The objects of this study was to evaluate the accuracy of the dental stone casts made from alginate impressions according to storage condition and stone pouring time. Materials and Methods: Each of upper and lower impressions of dental model was taken. The dental stone models were made immediately, 10, 30, 60, 180, 360 minutes after the impressions were taken at each storage condition. 3D models were constructed by scanning the stone model using 3D laser scanner. With Reference points, positioned on digital models, linear measurements of the dimensional change were compared by 3D metrology software, 3D average models were made and superimposition to identify the specific site of dimensional change and to measure surface deviation (mm). Results: Dental stone models which were made immediately after taking the impression showed the smallest linear dimensional change. As the stone pouring time was prolonged, the linear dimensional change was increased. More than 180 minutes after impression taking, linear dimensional change and surface distortion increased in the posterior molar region, regardless of the storage condition. Conclusion: For the optimum accuracy of the dental stone casts, alginate impression should be poured as soon as possible. If there were a need for storing, a humidor with 100% relative humidity must be used and be stored less than 180 minutes to fabricate the accurate dental model.

Investigation about the Actual Prevention of Infection and Vaccination against B-type Hepatitis among Dental Workers in Daegu (대구지역 치과 의료기관 종사자의 B형간염 예방접종 및 감염관리 실태)

  • Eun, Jeong-Hwa;Bae, Ji-Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.219-233
    • /
    • 2005
  • This study was conducted on 185 workers at 73 dental clinics and university hospitals in Daegu to investigate the actual prevention of infection and vaccination against B-type hepatitis among dental workers. 1. According to the result of medical examination, only 35 out of 144 (24%) dental clinic workers had periodic health examination while 7 out of 9 (78%) university hospital workers did. 2. In a survey on vaccination against B-type hepatitis, 52 workers aged 29 or younger (96.3%), 38 dental hygienists (51.9%) and 44 dental workers at dental clinics (81.5%) have not had any vaccination against B-type hepatitis. The rest appeared to have had vaccination or be aware that they had antibody against B-type hepatitis without having to have any vaccination. 3. According to the result of a survey on the existence of antibody by job, 42 (56%) of dental hygienists, 15 (20%) of assistant nurses, 12 (16%) of medical assistants and 6 (8%) of dental technicians did not know whether or not they had antibody. This suggests that all types of dental workers except dental hygienists have low awareness of whether or not they have antibody. 4. In a survey on the relation between general characteristics of subjects and the sterilization of dental equipment, alcohol disinfection of high speed handpiece and low speed handpiece was most common among dental workers aged 29 or younger, and all of those aged over 40 used autoclave. By position, alcohol disinfection was used most commonly for high-speed handpiece. antiseptic solution deposition for disposable suction lips, and autoclaving for impression. By workplace, dental workers at university hospitals used autoc1aving most frequently for high/low speed handpiece while those at dental hospitals and dental clinics used alcohol disinfection most frequently and even some respondents replied that they did not disinfect. For metal cups, workers at dental clinics and dental hospitals did not use any sterilizing method while those at university hospitals used autoclaving. For disposable suction tips, workers at dental clinics used antiseptic solution deposition and those at dental hospitals used alcohol disinfection but some respondents replied that they did not disinfect. For metal suctions and impression trays, autoclaving was most common in all workplaces but some dental clinics replied that they did not disinfect impression trays. According to work experience, alcohol disinfection was most common for high/low speed handpiece. For disposable suction tips, dental workers with 3 years' or shorter work experience, those with 3~6 years' experience and those with 9~12 years' experience used antiseptic solution deposition most commonly, and many of those with 6~9 years replied that they did not disinfect. The results of this study stated above suggest that systematic education is necessary for all dental workers for enhancing th eir awareness of B-type hepatitis and the prevention of infection. Moreover, dental workers are required to make efforts to prevent infection with B-type hepatitis voluntarily and actively.

  • PDF

Comparison of mechanical properties and flowability of dental impression materials (치과용 인상재의 기계적 물성 및 흐름성 비교)

  • Kim, Ji-Yeob;Song, Kun-Ho;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.36
    • /
    • pp.39-43
    • /
    • 2016
  • The purpose of this study is to determine and compare the mechanical and flow properties of polyvinylsiloxane impression pastes. Twelve polyvinylsiloxane impression materials were used. As mechanical properties, tensile strength and tear resistance were measured. Impression materials are subjected to tensile stresses when they are removed from the oral cavity and from stone models and tear resistance is the ability of the material to resist tearing under a tensile stress. Flow is dependent on the ability of the material to resist shear forces. Flow tests were performed to determine the handling characteristics and was measured using a shark fin testing device. An impression material must be able to penetrate the narrow subgingival sulcus and tight interproximal areas. Therefore, it must be able to resist the shear forces as it is pushed between tooth and gingival walls. It is necessary to understand the properties of interocclusal recording materials and is considered that the results obtained in this study will provide guideline information for the manufacturing of impression materials and for selecting appropriate impression materials.

  • PDF

Impression procedures for removable partial dentures (가철성 국소의치 제작을 위한 인상채득)

  • Heo, Yu-Ri;Son, Mee-Kyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.152-158
    • /
    • 2014
  • To fabricate removable partial denture which provide patient's comfort and maintain oral health, cast fabrication which reproduce anatomical and functional state of mouth is needed. Diagnostic cast and master cast are produced through the process of preliminary impression and final impression taking. Both of remaining teeth and edentulous area should be well taken in removable partial denture impression. According to the supporting type of partial denture, impression material and method can be changed. Therefore, understanding of impression procedure is essential for the accurate clinical application.

A COMPARISON OF ACCURACY BETWEEN FIXTURE IMPRESSION AND ABUTMENT IMPRESSION FOR DENTAL IMPLANTS (치과 임플랜트용 고정체 인상법과 지대원주 인상법간의 정확성 비교)

  • Choi, Hyun-Sik;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.662-673
    • /
    • 1997
  • The purpose of this study was to compare the accuracy between future impression and abutment impression using strain gauges. The master model used in this study was a partially edentulous mandibular metal cast with two fixture analogs on both sides. On the left, two future analogs were parallel, whereas right side, posterior future analog exhibiting a 15-degree lingual inclination. From master cast, 10 impressions were made for each of the three impression methods. The master frameworks was fabricated on the master model, and two-element strain gauge was attached to a master framework. The master framework was seated on each cast, and gold screws were tightened to 10 Ncm using a torque controller AI-1600 strain measurement system was used for strain measuring. Impression methods studied were : Group 1:abutment impression Group 2:fixture impression Group 3:combined impression (anterior:fixture impression, posterior:abutment impression) The results were as followed. 1. The strain values on X-axis and Y-axis according to the three impression methods showed no significant difference. 2. The strain values on parallel and angulated groups according to the three impression methods showed no significant difference. 3. The parallel group exhibited significantly higher accuracy in adaptation than angulated group for all experimental groups (p<0.05). In conclusion, it is considered that accuracy of implant prostheses is more affected by implant angulation than impression methods.

  • PDF

The Influence of Different Gypsum Materials on the Accuracy from Complete Arch Digital Impression (전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Hae-Young;Kim, Jae-Hong
    • Journal of dental hygiene science
    • /
    • v.12 no.6
    • /
    • pp.617-623
    • /
    • 2012
  • This study was performed to measure the accuracy of different gypsum materials by a white light dental scanner. A master model with the prepared lower full arch tooth was used. The type IV and scannable stone were used for 20 stone casts (10 casts each) duplicated a master model of mandible. The distance between the reference points were measured and analyzed by the Delcam $Copycad^{(R)}$ (Delcam Plc, UK) 3D graphic software. The t-student test for paired samples were used for statistical analysis. The mean differences to master model for type IV stone and scannable stone model were 0.29~0.56 mm, and 0.17~0.35 mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between the master model and type IV/scannable stone (p<0.05). Two different gypsum materials showed clinically acceptable accuracies of full arch digital impression produced by them. Besides, in both gypsum materials, the differences to the master model detected appear to provide enough accuracy for clinical application.

A Clinical Study on the Dimensional Accuracy of the Combined Impression (Alginate & Agar-Agar) (Alginate와 Agar-Agar에 의한 연합인상법의 촌법정도에 관한 임상적 연구)

  • Ha, Ju-Tai;Lee, Jung-Man;Choi, Boo-Byung
    • The Journal of the Korean dental association
    • /
    • v.17 no.9 s.124
    • /
    • pp.701-708
    • /
    • 1979
  • A series of combined impressions, alginate impressions and rubber base impression made of the lower left quadrant of one subject having a cast gold crown with six reference marks on lower let 1st molar. the combined impressions of hydrocolloid were removed from the mouth at 2.5min, after the insertion of the tray. The alginate impressions were removed from the mouth at 2min, after the insertion of the tray. The rubber base impressions were removed from the mouth at 10min. The effect on the accuracy of the combined impressions, alginate impressions and rubber base impressions was obtained following results by comparing the distances between the reference marks in indirect stone cast with the standard measurements of the cast gold crown prior to cementation. The findings through this study could be summarized as follows; 1. The accuracy of combined impression was superior to that of alginate impression, but it was inferior to that of rubber base impressions. 2. Combined impressions produced a little distortion of the mesio-distal length, alginate impressions produced the largest distortion, ut rubber base impressions produced the least distortion.

  • PDF

ACCURACY OF STONE CAST PRODUCED BY ADJUSTABLE DENTAL IMPRESSION TRAY (가변형 치과 인상용 트레이로 제작된 모형의 재현성에 관한 연구)

  • Eom Sang-Ho;Oh Sang-Chun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.453-465
    • /
    • 2005
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and methods: The metal stock, individual, and adjustable stock trays were used for 60 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a vinyl polysiloxane impressions and allowed to set for one hour. The master model and the duplicated casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software(CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results : There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch and the diagonal arch length and arch length on one side of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study cast produced by them.