• 제목/요약/키워드: Dental impression

검색결과 345건 처리시간 0.024초

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • 제15권1호
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.

Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses

  • Abduo, Jaafar
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.138-146
    • /
    • 2019
  • PURPOSE. Comparing the accuracy of casts produced from digital workflow to that of casts produced from conventional techniques. MATERIALS AND METHODS. Whole arch alginate (ALG) and polyvinyl siloxane (PVS) impressions were taken with stock trays and custom trays, respectively. The ALG impressions were poured with type III dental stone, while the PVS impressions were poured with type IV dental stone. For the digital workflow, IOS impressions were taken and physical casts were produced by 3D printing. In addition, 3D printed casts were produced from images obtained from a laboratory scanner (LS). For each technique, a total of 10 casts were produced. The accuracies of the whole arch and separated teeth were virtually quantified. RESULTS. Whole arch cast accuracy was more superior for PVS followed by LS, ALG, and IOS. The PVS and ALG groups were inferior in the areas more susceptible to impression material distortion, such as fossae and undercut regions. The LS casts appeared to have generalized errors of minor magnitude influencing primarily the posterior teeth. The IOS casts were considerably more affected at the posterior region. On the contrary, the IOS and LS casts were more superior for single tooth accuracy followed by PVS and ALG. CONCLUSION. For whole arch accuracy, casts produced from IOS were inferior to those produced from PVS and ALG. The inferior outcome of IOS appears to be related to the span of scanning. For single tooth accuracy, IOS showed superior accuracy compared to conventional impressions.

디지털 인상법과 전통적 인상법의 정확도 비교: 체계적 고찰 (Comparison of the accuracy of digital impressions and traditional impressions: Systematic review)

  • 김경록;서권수;김선재
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.258-268
    • /
    • 2018
  • 목적: 본 연구는 보철물의 적합 및 인상의 정확성에 관한 문헌들을 체계적으로 고찰하여 구강 내 스캐너를 이용한 디지털 인상법이 전통적인 인상법을 대체할 만한 정확도를 보이는지 알아보고자 한다. 재료 및 방법: 1997년 8월 1일부터 2017년 7월 31일까지 출판된 영어로 쓰여진 연구를 대상으로 디지털 인상법의 정확성에 대한 문헌을 MEDLINE/PubMed 전자 검색 및 수기탐색을 시행하였다. 조건에 따라 선택된 연구의 데이터를 스프레드 시트에 2명의 검토자가 독립적으로 정리하였다. 결과: 총 35개의 연구가 선택되었고, 26개의 연구는 보철물의 적합성을 비교하였고 9개의 연구는 보철물 없이 스캔 데이터를 통해 인상의 정확성을 비교하였다. 대부분의 연구가 보철물을 이용해 인상법의 정확성을 비교하였다. 결론: 본 고찰에 따르면 자연치열에서 디지털 인상법으로 단일관이나 근원심으로 길이가 짧은 보철물을 제작하는 것은 임상적으로 충분히 신뢰할만한 하다. 그러나 디지털 인상법으로 길이가 긴 보철물을 제작하는 것은 연구가 적어 아직 한계가 있다. 임플란트 보철물 제작에 있어서 구내스캐너를 이용한 디지털 인상법으로 전통적인 인상법을 완전히 대체하기는 아직 어렵다.

심하게 흡수된 치조제를 가진 환자에서 고딕 아치 기록과 무압 인상을 이용한 총의치 수복: 증례보고 (Rehabilitation of a patient with atrophic ridges using gothic arch tracing and nonpressure impression: a case report)

  • 이신엽;유정현
    • 구강회복응용과학지
    • /
    • 제34권3호
    • /
    • pp.232-238
    • /
    • 2018
  • 가동성 조직은 총의치의 안정성을 감소시키므로, 최종의치의 제작 전에 조직의 상태를 개선시킨 후 적합하게 수정된 인상 방법을 사용하여야 하며, 적절한 중심위를 채득해야 한다. 본 증례는 상악의 가동성 조직과 하악 치조제의 심한 흡수를 보이는 67세의 무치악 여자 환자로, 고딕 아치 기록을 이용하여 치료용 의치를 제작한 뒤 조직조정을 시행하였다. 최종의치는 window opening 인상채득법과 고딕 아치 기록, 그리고 설측 교두 교합을 이용하여 제작하였고, 심미적 및 기능적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

수종의 화학소독제에 침적시킨 고무인상체의 크기안정성에 관한 연구 (A STUDY ON DIMENSIONAL STABILITY OF THE RUBBER IMPRESSION MATERIALS FOLLOWING IMMERSION WITH CHEMICAL DISINFECTANTS)

  • 김형식;김창회
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.249-259
    • /
    • 1989
  • Dental impression materials often become contaminated with patients' saliva and blood which creates the potential for cross-infection. It was the purpose of this study to investigate the effects of disinfection of three different rubber impression materials with four different disinfecting solutions. Polysulfide, vinyl polysiloxane and polyether impression materials were mixed according to the manufacturer's directions and samples were formed on a stainless steel model. On removal from the standard model, impressions were immersed in a disinfectant (acid-potentiated glutaraldehyde, phenollic compound, chlorine compound, iodophor) at room tempera tures for ten minutes. After disinfection, the distance between reference points(linear dimension) was measured using the non-contact automatic cordinate measuring projector(MZ-1, Nikon). Through statistical analyses on the data from this study,. the following conclusions were obtained. 1. Polysulfide, vinyl polysiloxane impressions were disinfected without dimensional change.(p>0.05) 2. Polyether impressions which were immersed in acid-potentiated glutaraldehyde were statistically different from control group.(p<0.05) But the amount of shrinkage(0.04%) would not be clinically significant. 3. By immersion of polysulfide, vinyl polysiloxane, polyether impressions in Banicide, Biocide, Multicide plus, sodium hypochlorite for ten minutes, clinically accurate impressions were obtained without dimensional change.

  • PDF

인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향 (The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings)

  • 이지혁;최유성;조인호
    • 구강회복응용과학지
    • /
    • 제26권4호
    • /
    • pp.433-445
    • /
    • 2010
  • 본 연구에서는 주모형으로부터 인상체를 제거한 후 인상용 코핑이 인상체 내에 남아있는 개방형 트레이 인상법의 이용 시, 인상용 코핑의 연결고정에 따른 효과와 인상 채득 시 사용될 수 있는 수종의 트레이가 주모형의 정확성에 미치는 영향에 대해 비교 연구해 보고자 하였다. 자가중합형 트레이 레진으로 제작한 개인 트레이, 플라스틱 금속 복합 트레이 그리고 폴리카보네이트 기성 트레이 등의 3종류의 트레이가 사용되었고, 각 트레이 마다 인상용 코핑의 연결고정 여부에 따라 두 개의 군으로 나누었다. 이렇게 나누어진 총 6개의 군에서 각 실험군당 10개의 시편을 제작하였다. 임플랜트 유사체와 지대주 사이에 발생한 수직오차의 측정에는 1-screw test법을 이용하였다. 1시편 당 총 6부위를 측정하였고, 3회씩 측정하여 동일한 수치를 나타낼 경우에 기록하여 통계 처리하였다. 인상용 코핑의 연결고정 여부와 상관없이 개인 트레이군, 플라스틱 금속 복합 트레이군 그리고 폴리카보네이트 기성 트레이군 사이에 유의한 차이는 나타나지 않았다. 하지만 개인 트레이, 플라스틱 금속 복합 트레이 그리고 폴리카보네이트 기성 트레이를 이용하여 인상 채득한 경우 패턴 레진으로 연결고정한 군이 비연결고정 군보다 더 정확한 결과를 보여주었다 (p<0.05).

수종 인상재의 혼합방법에 따른 기포형성과 표면 재현력에 관한 연구 (A STUDY ON THE VOID FORMATION AND DETAIL REPRODUCTION ACCORDING TO THE VARIOUS IMPRESSION MATERIALS AND MIXING METHODS)

  • 류형선;임헌송;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제40권2호
    • /
    • pp.140-155
    • /
    • 2002
  • Void-free impression taking is important for the fabrication of accurate dental restorations. One of the essential properties of an impression material used for indirect fabrication of precision castings is the reproduction of the fine detail. The objective in this study was to determine the influence of mixing methods on the number of voids and surface detail reproduction. The number of voids and surface detail reproduction were evaluated with the steteomicroscope $SZ-PT^{(R)}$ and photographed. The results were as follows ; 1. In comparison of the void formation according to mixing methods of all impression materials, mechanical mixing was better than hand mixing and there was significant difference(p<0.05) 2. In comparison of the void formation according to hand mixing of alginate impression materials($TOKUSO\;A-1{\alpha}^{(R)},\;CAVEX\;IMPRESSIONAL^{(R)},\;AROMA \;FINE\;DF\;III^{(R)}$), there was no significant difference among alginate groups. But the number of void was increased in the order of $Panasil^{(R)}\;contact,\;TOKUSO\;A-1{\alpha}^{(R)},\;Permlastic^{(R)}$ light bodied and there was significant difference (p<0.05). 3. In comparison of the void formation according to mechanical mixing of alginate impression materials($TOKUSO\;A-1{\alpha}^{(R)},\;CAVEX\;IMPRESSIONAL^{(R)},\;AROMA FINE\;DF\;III^{(R)}$), there was no significant different among alginate groups. But the number of void was decreased in order of $TOKUSO\;A-1{\alpha}^{(R)},\;Permlastic^{(R)}light\;bodied,\;Panasil^{(R)}$ contact and there was significant difference (p<0.05). 4. In comparison of the surface detail reproduction according to mixing methods of 3 types of impression materials($TOKUSO\;A-1{\alpha}^{(R)},\;Permlastic^{(R)}\;light\;bodied,\;Panasil^{(R)}\;contact$), there was no significant difference between hand mixing and mechanical mixing method 5. The surface detail reproduction was only influenced by impression materials, and produced better in order of $TOKUSO\;A-1{\alpha}^{(R)},\;Panasil^{(R)}\;contact,\;Permlastic^{(R)}$ light bodied. There was significat difference among 3 type of impression materials(p<0.05). From the above results, void formation is influenced by mixing methods and surface detail reproduction is influenced by impression materials than mixing methods. Therefore, to fabricate accurate restorations, proper impression material and mechanical mixing method are more effective and available clinically.

아기-알지네이트 연합 인상체의 보관방법 및 idophor 침적소독에 의한 체적 변화에 관한 연구 (AGAR-ALGINATE COMBINED IMPRESSION TECHNIQUE AND DIMENSIONAL CHANGE RESULTING FROM IDOPHOR DISINFECTION)

  • 오남식;서정민;김선희;윤영아;심준성
    • 대한치과보철학회지
    • /
    • 제42권1호
    • /
    • pp.21-29
    • /
    • 2004
  • Statement of problem : Because dental impression can be a cross-infection source, disinfection, such as immersion disinfection is nessecary. However, the disinfection process may change the volume of the impression cast. Purpose : The purpose of this study is to find out the effects on dimensional change of different storage times and methods, of agar-alginate impression when immersed in a 5% idophor disinfectant. Material and Methods : An agar-alginate impression was made from a mandible model and then was disinfected and stored according the experimental conditions and a stone model was produced. Measurements were taken between reference points on the original mandible model and they were compared to measurements taken between reference points on the stone model. The study was divided into 4 groups. In group 1, the impression was stored in a 100% humidor for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours and 24 hours and stone models were made at each time. In group 2, the impression was immersed in 5% idophor disinfectant and then stored in a 100% humidor for the same length of times as group 1, and stone models were made at each time. In group 3, the impression was stored in extend-A-pourR, a special storage solution for 30 minutes, 1 hour, 2 hours, 3 hours, 4 hours, 6 hours, 12 hours, 24 hours 3 days, and 7 days and stone models were made at each time. In group 4, the impression was immersed in 5% idophor disinfectant and then stored in stored in extend-A-pourR, a special storage solution for the same length of times as group 3, and stone models were made at each time. 5 impressions and stone models were made at each time to make a total of 180. The Student-t test (P < .05) was used to do a statistical analysis of the measurements of the mandible model and stone models. The repeated-measure 2-way analysis of variance (P < .05) was used to do a statistical analysis of the difference in the 4 groups. Results : The percent liner dimensional change was from $0.25{\pm}0.03%$ (group 1, 30 minutes) to $0.34{\pm}0.06%$ (group 4, 7 days). No significant change was noticed between the 4 groups. Conclusion : According to the above study, in both methods, least dimensional change was recorded when the storage times were short and in both methods, immersion in 5% idophor disinfectant did not effect dimensional change in the agar-alginate impression.

Creating protective appliances for preventing dental injury during endotracheal intubation using intraoral scanning and 3D printing: a technical note

  • Cho, Jin-Hyung;Park, Wonse;Park, Kyeong-Mee;Kim, Seo-Yul;Kim, Kee-Deog
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권1호
    • /
    • pp.55-59
    • /
    • 2017
  • Digital dentistry has influenced many dental procedures, such as three-dimensional (3D) diagnosis and treatment planning, surgical splints, and prosthetic treatments. Patient-specific protective appliances (PSPAs) prevent dental injury during endotracheal intubation. However, the required laboratory work takes time, and there is the possibility of tooth extraction while obtaining the dental impression. In this technical report, we utilized new digital technology for creating PSPAs, using direct intraoral scanners and 3D printers for dental cast fabrication.

인상채득 후 시간경과와 반복주입에 따른 부가중합형 실리콘 인상재의 체적변화 (Evaluation of the Time and Pouring Frequency Dependent Dimensional Stability of Additional Silicone Impression Materials.)

  • 최미라
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.239-248
    • /
    • 2007
  • The accuracy and dimensional stability of rubber impression materials are very important for the fitness of the final restoration. The purpose of this investigation was to evaluate the effects of the storage time and pouring frequency of the additional silicone materials on dimensional stability. Total 30 impressions were made of tooth prepared single crown. The dies had 1 buccolingual, 1 mesiodistal and 1 occlusogingival lines. Two additional silicone materials(examixfine, aquasil) were included. 15 specimens were made of each impression material and poured by type IV stone over times(1hour, 24hours, 72hours) after mixing. 5 impressions poured after 1 hour were used for second pouring after 24hours and third pouring after 72hours. The same examiner measured each specimen 3 times after lazer scanning. All statistical tests were performed with the level of significance set at 0.05. The results indicated that significant difference at any measuring point of stone dies except the buccolingual and mesiodistal lines of the specimen made at 1hour after mixing with examixfine when measurements at 1hour, 24hours and 72hours were campared. There were significant difference between two impression materials and at every measuring point of stone dies made at second and third pouring. The length of measuring point increased significantly as time passed by and increase of the pouring frequency. However, this results are clinically acceptable except the dies of the third pouring. Under the conditions of this study, the shrinkage rate of the additional silicone rubber impression materials significantly increased as time passed by and increase of the pouring frequency.