• Title/Summary/Keyword: Dental implant-abutment connection

Search Result 95, Processing Time 0.034 seconds

지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향 (Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis)

  • 박현수;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

수종의 내부연결형 임플란트에서 연결부의 형태에 따른 응력분포의 유한요소 분석 (Finite element analysis on the connection types of abutment and fixture)

  • 정병현;이경제;강동완
    • 대한치과보철학회지
    • /
    • 제50권2호
    • /
    • pp.119-127
    • /
    • 2012
  • 연구 목적: 본 연구는 3차원 유한요소분석을 통해 특징적인 내부연결구조를 갖는5종의 임플란트의 고정체와 지대주의 연결방식에 따른 응력분산을 알아보고자 하였다. 연구 재료 및 방법: 본 실험을 위한 유한요소모델은 하악 제1대구치부에 임플란트가 식립되고 상부구조물로 3형 금합금을 사용하는 것으로 가정하였다. 응력분산은 200 N의 하중이 교합면의 중심, 중심에 1.5 mm 외측, 중심에서 3.0 mm 외측에 수직으로 가해지고 임플란트의 장축과 $30^{\circ}$의 각도로 경사하중이 가해지도록 하여 분석하였다. 유한요소모델에 대한 해석작업은 3G.Author (PlassoTech, California, USA)를 사용하여 이뤄졌다. 결과: 경사가 없는 내부계단 구조를 가지는 DAS tech의 임플란트의 경우, 내부연결구조를 갖는 다른 임플란트에 더 유리한 응력분산을 보였다. 하중이 임플란트 고정체의 외형선 이내에 가해지는 경우와 비교하여 외형선 바깥이나 경사력으로 전해지는 경우 더 높은 응력을 보였으며 하중조건과 관계없이 임플란트 고정체보다는 지대주에 더 큰 응력이 집중되었다. 결론: 교합력이 가해졌을 때 응력분산은 임플란트의 연결부의 형태와 하중이 가해지는 위치에 따라 달라졌으며 내부계단 구조를 가지는 DAS tech의 임플란트를 사용한 경우와 고정체의 외형선 이내에 하중이 가해졌을 경우에 더 유리한 응력분산을 보였다.

Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants

  • Mohammed, Hnd Hadi;Lee, Jin-Han;Bae, Ji-Myung;Cho, Hye-Won
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.62-69
    • /
    • 2016
  • PURPOSE. The purpose of this study was to evaluate the effects of abutment screw length and cyclic loading on the removal torque (RTV) in external hex (EH) and internal hex (IH) implants. MATERIALS AND METHODS. Forty screw-retained single crowns were connected to external and internal hex implants. The prepared titanium abutment screws were classified into 8 groups based on the number of threads (n = 5 per group): EH 12.5, 6.5, 3.5, 2.5 and IH 6.5, 5, 3.5, 2.5 threads. The abutment screws were tightened with 20 Ncm torque twice with 10-minute intervals. After 5 minutes, the initial RTVs of the abutment screws were measured with a digital torque gauge (MGT12). A customized jig was constructed to apply a load along the implant long axis at the central fossa of the maxillary first molar. The post-loading RTVs were measured after 16,000 cycles of mechanical loading with 50 N at a 1-Hz frequency. Statistical analysis included one-way analysis of variance and paired t-tests. RESULTS. The post-loading RTVs were significantly lower than the initial RTVs in the EH 2.5 thread and IH 2.5 thread groups (P<.05). The initial RTVs exhibited no significant differences among the 8 groups, whereas the post-loading RTVs of the EH 6.5 and EH 3.5 thread groups were higher than those of the IH 3.5 thread group (P<.05). CONCLUSION. Within the limitations of this study, the external hex implants with short screw lengths were more advantageous than internal hex implants with short screw lengths in torque maintenance after cyclic loading.

제1대구치 위치에 식립된 단일 임플란트의 지대주 연결 유형에 따른 임플란트 주위골 흡수 (Marginal bone loss between internal- and external- abutment connection type implants placed in the first molar area)

  • 이석현;이은우;정하나;김옥수
    • 구강회복응용과학지
    • /
    • 제39권1호
    • /
    • pp.32-44
    • /
    • 2023
  • 목적: 이번 연구는 상·하악 제1대구치 부위에 식립 된 단일 임플란트를 통해 임플란트-지대주 연결 유형이 임플란트의 변연골 소실 (MBL)에 영향을 주는지, 그리고 MBL에 영향을 끼치는 요인들을 알아보기 위해 분석하였다. 연구 재료 및 방법: 5년 이상의 추적 기간 동안, 상·하악 제1대구치 부위에 단일 임플란트를 식립하여 수복한 68명의 환자(남: 38명, 여: 30명)의 87 임플란트(external connection type (EC) 임플란트: 57개, internal connection type (IC) 임플란트: 30개)를 대상으로 추적 조사하였다. 최대 5년 후의 구내 방사선 영상에서 MBL과 보철물의 출현 각도(EA)를 측정하였다. 60 - 79세에 해당하는 환자의 비율이 52.9%로 가장 높았고 상악 구치부에 임플란트가 가장 많이 식립되었다. 결과: GBR을 하지 않은 경우 EC (-0.065 ± 0.859 mm)와 IC (-0.627 ± 0.639 mm)에서 유의한 차이가 있었고, 또한 당뇨병이 없는 환자들 사이에서 EC (-0.131 ± 1.002 mm)와 IC (-0.792 ± 0.762 mm)에서 유의한 차이가 존재하였다. 임플란트 매식체의 직경, 길이, 보철물 연결 방법, 임플란트 제조업체, 보철물의 emergence angle (EA)로 구분하였을 때 각군 간에 유의미한 차이가 없었다. 다중회귀분석을 이용하여 MBL에 영향을 주는 요인분석 결과 회귀계수의 유의성 검증에서 임플란트-지대주 체결 방식(β = -0.303), 당뇨병의 유무(β = -0.113), EA의 차이(β = -0.234), 나이(β = -0.776)에서 MBL에 통계학적으로 유의한 음의 상관관계를 보였다. 결론: IC가 EC보다 GBR을 하지 않은 경우와 당뇨병이 없는 환자들 사이에서 MBL이 작다는 것을 알 수 있었다. 또한 보철물의 EA가 30°보다 큰 보철물의 형태를 가진 임플란트가 30°보다 작은 보철물의 형태를 가진 임플란트 보다 MBL이 컸으며 나이가 많을수록 MBL이 크다는 것을 알 수 있었다. 임플란트의 MBL을 최소화하고 임플란트 안정성을 확보하기 위해서 임플란트 보철물의 EA와 임플란트-지대주 연결 유형을 세심하게 고려해야 할 것이다.

임플란트 주위 골변화와 생존율에 대한 연구 (The study on the survival rates and crestal bone changes around the implants)

  • 최현숙;정현주;김옥수;김영준
    • Journal of Periodontal and Implant Science
    • /
    • 제34권2호
    • /
    • pp.303-315
    • /
    • 2004
  • The success and failure of dental implants depends on various factors such as patient's systemic status, quantity and quality of surrounding bone, presence or absence of marginal infection and mechanical loading condition. The measurement of crestal bone changes around the implants is implemental to evaluate the success and long-term prognosis of the implant. This study was to evaluate the cumulative survival rate of the implants which had been placed in the Department of Periodontics, Chonnam National University Hospital between 1992 and 2003, and to observe the crestal bone loss around the implants which had at least 2 consecutive periapical radiographs after connecting the transmucosal abutment. The radiographs were scanned and digitalized, and the crestal bone levels on the mesial and distal surface of implants were measured using Image analyzer (Image Pro Plus, Media Cybernetics, USA), immediately after implant placement, at 2nd surgery, and 3 months, 6 months, 1 year, and every year thereafter. Any bone loss was not observed during the period between the 1stand 2nd surgery, and the bone loss was 0.86 ${\pm}$ 0.92 mm for the first year of loading after connecting the transmucosal abutment. After 1 year of loading, annual bone loss was 0.1 ${\pm}$ 0.27 mm, and total bone loss was 0.90 ${\pm}$ 0.80 mm (during the average follow-up periods of 22.5 ${\pm}$ 25.6 Mos), The implant, with smooth surface, in the mandible, and with the fixed bridge prosthesis showed greater bone loss, compared to those, with the rough surface, in the maxilla and with single crown. In systemically diseased patients (including DM or osteoporosis), the greater bone loss was observed. The cumulative survival rate among 432 implants was 94.10% for 7 years. Among 15 failed implants, 9 implants were removed due to mobility from disintegration of bone-implant interface. From this results, crestal bone loss around the implants were greatest during 1 year after transmucosal abutment connection, and various factors could affect peri-implant bone loss. To prevent and predict the bone loss around the implants and improve the prognosis, further comprehensive maintenance and follow-up schedules are required.

내측 연결 및 외측 연결 방식으로 설계된 임플란트의 3차원적 유한요소 응력 분석 (Stress distribution of implants with external and internal connection design: a 3-D finite element analysis)

  • 정현주;양성표;박재호;박찬;신진호;양홍서
    • 구강회복응용과학지
    • /
    • 제33권3호
    • /
    • pp.189-198
    • /
    • 2017
  • 목적: 외측 육각형과 내측 원추형 연결부로 설계된 임플란트 지지 하악 구치 수복물에 교합력을 가할때 발생하는 생역학 현상을 분석하고자 한다. 연구 재료 및 방법: 외측 연결형 임플란트(EXHEX)와 내측 연결형 임플란트(INCON) 그리고 이와 결합할 해당 나사와 지대주 및 크라운을 제작하였고, 하악 무치악 치조골을 설계하였다. 각 부분을 조립하여 2종의 유한요소 모형을 제작하였다. 총 120 N 크기의 수직력(L1)과 45도 측방력(L2)을 가하였고, 유한요소 응력 분석을 시행하였다. 결과: L2 측방력 하중에 의해 발생한 최대 응력은 L1 수직력 하중에 의한 것 보다 6 - 15배 더 컸다. INCON 모델은 EXHEX 모델보다 크라운 교두부에서 2.2배 더 큰 변위량을 보여 주었다. 측방력에 의해 EXHEX 모델은 나사에서, INCON 모델은 임플란트 고정체의 상단 변연부에서 폰미세스 응력의 최대값이 관찰 되었다. INCON 모델에서는 임플란트 내부 계면에서 긴밀한 접촉이 유지 되었다. 결론: 측방력이 큰 변형과 응력을 발생하였으나, 임플란트에서의 최대 응력 발생부위는 INCON과 EXHEX 모델이 서로 상이하였다.

내부연결 원추형 임플란트의 육각구조의 유무에 따른 연결부 안정성: 실험적 연구 (Joint stability of internal conical connection abutments with or without hexagon indexes: an in vitro study)

  • 이상운;차민상;이지혜;조리라;박찬진
    • 구강회복응용과학지
    • /
    • 제36권2호
    • /
    • pp.95-103
    • /
    • 2020
  • 목적: 본 연구의 목적은 내부연결 원추형 임플란트의 육각구조 유무가 임플란트 지대주 장축변위와 임플란트 지대주 나사의 풀림토크에 미치는 영향을 평가하고자 하였다. 연구 재료 및 방법: 내부연결 원추형 임플란트를 육각구조를 가진 지대주 그룹(HEX)과 육각구조를 갖지 않는 지대주 그룹(CON)으로 나누고 각 그룹 당 10쌍의 시편을 체결하였다. 지대주 나사를 30 Ncm 조임회전력을 가하여 체결한 뒤 장축변위 및 풀림토크값을 측정하고 250 N 수직적 반복하중을 100,000회 가한 뒤 장축변위 및 풀림토크값을 측정하였다. 각 단계마다 디지털 마이크로미터를 이용하여 임플란트 직경과 수직적 높이를 측정하였고 전자 토크게이지를 이용하여 풀림토크값을 측정하였다. 각 군간의 값의 유의차를 확인하기 위하여 독립 표본 T 검정을 이용하여 통계분석하였다(α = 0.05). 결과: HEX 군은 조임회전력을 가한 뒤 유의하게 높은 장축변위를 나타내였다(P < 0.05). HEX 군과 CON 군은 수직적 반복하중 후 장축변위에 유의한 차이를 보이지 않았다(P = 0.052). HEX 군과 CON 군은 수직적 반복하중 전, 후 풀림토크값 모두 유의한 차이를 보이지 않았다(P = 0.057 and P = 0.138). 모든 그룹에서 반복하중 후 풀림토크값 상실율이 증가하였다(P < 0.05). 결론: 내부연결 원추형 임플란트에서 육각구조를 가진 경우 장축 변위가 더 컸으며, 그 외의 연결부 안정성은 유사하였다. 모든 그룹에서 반복하중 후 풀림토크값 상실율이 증가하였다.

구치부 임플란트 고정성 수복물에서의 지대주 나사 풀림 현상과 이에 영향을 미치는 요인 (The incidence of the abutment screw loosening and its affecting factors in posterior implant restorations)

  • 홍수정;배정윤;김현희
    • 대한치과보철학회지
    • /
    • 제56권3호
    • /
    • pp.212-217
    • /
    • 2018
  • 목적: 본 연구의 목적은 구치부 식립 임플란트에서 지대주 나사 풀림의 발생 빈도 및 지대주 나사 풀림에 영향을 주는 다양한 요인들을 후향적 연구를 통하여 평가하는 것이다. 대상 및 방법: 2013년 1월부터 2016년 1월까지 208명의 환자에서 구치부에 식립한 391개의 임플란트를 대상으로 하였다. 모든 수복물은 고정성으로 단일 혹은 연결 크라운, 브릿지로 제작되었으며, 임시 시멘트로 합착하였다. 전체 수복물 중 지대주 나사 풀림의 발생 빈도를 조사하였고, 성별, 보철물의 위치, 대합치, 보철물의 유형, 지대주 연결 유형, 매식체의 지름이 지대주 나사 풀림에 미치는 영향을 평가하였다. 결과: 2 - 5년의 관찰 결과, 총 29개(7.4%)의 임플란트에서 지대주 나사 풀림이 발생하였다. 최종 수복 후 지대주 나사 풀림이 발생하기까지 소요된 기간은 3개월부터 48개월(평균19.5개월)까지 다양하게 나타났으며, 이 중 3개의 임플란트에서 매식체의 파절이 발생되었다. 고려 요인들 중, 임플란트의 식립 위치에 따라 대구치(9.4%)와 소구치(2.6%)에서 통계적으로 유의한 차이를 보였으며(P < .019), 대합치에 따라 자연치(9.9%), 임플란트(1.0%), 가철성 보철물(0%)에서 유의한 차이를 보였다(P < .018). 다른 고려 요인에 따른 지대주 나사 풀림 발생 빈도는 통계적 유의성이 없었다. 결론: 구치부 임플란트 수복물에서 지대주 나사 풀림의 발생 빈도는 7.4%로 나타났다. 소구치보다 대구치에서 유의하게 높은 발생 빈도를 보였으며, 대합치에 따라서는 임플란트, 가철성 보철물과 비교 시 자연치에서 유의하게 높은 발생 빈도를 보였다.

Long-term Retrospective Clinical Study Comparing Submerged Type with External Hex Connection and Non-submerged Type with Internal Morse Taper Connection Implants

  • Kwoen, Min-Jeong;Kim, Sang-Yun;Kim, Young-Kyun
    • Journal of Korean Dental Science
    • /
    • 제12권1호
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose: This study was aimed to compare the survival and success rates, and long-term crestal bone loss according to the use of 2 connection types of dental implants (submerged-USII and non-submerged-SSII; Osstem $Implant^{(R)}$) by analyzing the change in alveolar bone height after 1 year under load and during final follow-up period. Materials and Methods: Between December 2004 and August 2008, patients with two types of Osstem implants (USII and SSII) were retrieved retrospectively. A total of 92 patients with 284 implants (USII=60, SSII=224) was finally selected. Their mean follow-up period was 7.5 years. The mesial and distal alveolar crestal bone changes were measured using radiographic images and the average was calculated at 1 year after loading and during final follow-up period. Result: Among the 284 implants, 4 USII and 7 SSII implants were removed, indicating 93.3% and 96.9% survival rates. Of the survived implants, mean crestal bone loss 1 year after loading was 0.39 mm for USII and 0.19 mm for SSII (P=0.018). During the final follow-up, mean crestal bone loss was 0.63 mm and 0.35 mm for USII and SSII, respectively, without statistical significance (P=0.092). According to the criteria for the success and failure of the implant by Albreksson and colleagues, final success rate was estimated as 86.7% for USII and 91.5% for SSII, respectively. Conclusion At 1 year after loading, the average crestal bone loss was significantly different between USII and SSII; however, both types met the criteria for implant success. During the final follow-up, both groups showed insignificant bone resorption patterns and did not show any pathological clinical symptoms. Therefore, both implants exhibited high long-term stability.

임플란트의 생존과 변연골 소실에 영향을 미치는 인자들 (Factors associated with the survival and marginal bone loss of dental implants: a 5-year retrospective study)

  • 송을락;이재관;엄흥식;박세환;장범석
    • 구강회복응용과학지
    • /
    • 제32권4호
    • /
    • pp.280-292
    • /
    • 2016
  • 목적: 이 연구의 목적은 임플란트의 생존율과 주위 변연골 수준을 후향적으로 평가하여, 술자의 임상적 경험을 포함한 요인들이 미치는 영향을 분석하고자 하였다. 연구 재료 및 방법: 2002년 1월부터 2009년 3월까지 강릉원주대학교치과병원 치주과에서 전공의가 2단계법으로 식립한 임플란트 중 5년 이상의 기록이 있는 146명의 420개 임플란트를 대상으로, 임플란트 탈락여부, 주위 골 소실량, 성별, 연령, 2형 당뇨, 흡연, 지대주 연결 형식, 표면 처리 방법, 직경, 식립 부위, 식립 당시 전공의 연차, 덮개 나사의 조기 노출, 보철학적 합병증, 동반된 골 이식 술식 등의 영향을 평가하였다. 결과: 최종 보철물 장착 후 5년간 누적생존율은 94.9% 이었다. 이원로지스틱회귀분석 결과, 흡연과 덮개 나사의 조기 노출이 실패율을 유의하게 증가시켰다. 다중회귀분석 결과, 흡연, 임플란트 지대주 연결 형식, 및 표면 처리 방법이 임플란트 주위 변연골 수준 변화에 유의한 영향을 주었다. 술자의 임상경험을 반영하기 위한 식립 당시의 전공의 수련 연차는 임플란트의 실패와 유의한 연관성은 보이지 않았다(P = 0.171). 결론: 흡연, 덮개 나사의 조기 노출, 지대주 연결 형식 및 표면 처리 방법이 임플란트의 성공과 유의한 상관관계를 보이는 것으로 생각된다.