• Title/Summary/Keyword: Dental etching

Search Result 148, Processing Time 0.029 seconds

AN EXPERIMENT STUDY ON THE BOND STRENGTH OF ADHESIVE RESINS TO SUEEXSSIVELY RECAST ALLOYS FOR REISN-BONDED RESTORATIONS (반복주조된 치과용 합금의 피착면 처리방법에 따른 접착성 수지와의 접착강도에 관한 실험적 연구)

  • Jung, Kum Tai;Yang, Jae Ho;Lee, Sun Hyung;Jung, Hun Yung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.53-76
    • /
    • 1990
  • The purpose of this study was to evaluate the tensile bond strength of adhesive resins to successively recast Rexillium III and Degudent-U. Recasting was done 4times successively. Specimen $A_1$, were cast by new metal, and $A_2$ by surpus of $A_1$, $A_3$ by surplus of, $A_2$ $A_4$ by surplus of $A_3$, $A_5$ by surplus of $A_4$ plus 50% new metal. The types of surface treatment for resinbonded restoration in this experiment were electrolytic etching by OXY-ETCH(Oxy dental products, Inc., Hillside, New Jersey, U.S,A.), aluminum oxide blasting, anodic oxidation by EZ-OXISOR( Towagiken Co., Kyoto, Japan), electrotinplating by Kura Ace(Kuralay Co., Kyoto, Japan). Three kinds of cementing resin used in this study were Comspan(K.P. Cauil Co, Milford Delaware, U.S.A.), Super Bond C&B(Sun-Medical Co. Ltd., Kyoto,Japan), Panavia EX(Kuralay Co., Ltd., Osaka, Japan). Tensile bond strength was measured by Instron Universal testing machineModel 1125) and all the specimen were observed with SEM(JEOL, JSM-T2000) and mode of bond failure were recorded. The obtained results were as follows : 1. In electrolytic etched group, tensile bond strength was decreassed when recast alloy was used, and tensile bond strength of Compan and panavia EX were not significantly different(P>0.05). 2. In remaining group treated by aluminum oxide blasting, EZ-OXIOR, Kura Ace, tensile bond strength were not changed when recast alloy were used, and tensile bond strength of SuperBond(C&B and Panavia EX were not significantly different(P>0.05). 3. IN SEM evaluation, electrolytic etched group and electrotinplated group exhibited different image when recast alloy was used, and remaining groups treated by aluminum oxide blasting, EZ-OXISOR exhibited the same. 4. IN observation of bond failure, electrolytic etched group exhibited adhesive failure and remaing groups treated by aluminium oxid blasting, EZ-OXISOR, Kura Ace exhibited adhesive and cohesive failure.

  • PDF

THE EFFECT OF DIFFERENT SURFACE TREATMENT ON THE OSSEOINTEGRATION AND STABILITY OF IMPLANTS (처리 방법이 다른 표면이 임플랜트의 골유착 및 안정성에 미치는 영향)

  • Yang, Seoung-Wook;Lim, Heon-Song;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.606-616
    • /
    • 2006
  • Purpose: This experiment examined the effect of different surface treatment on the osseointegration and stability of implants. Material and methods: In this study, 40 each of machined, SLA and RBM implants, which are the most commonly used implants, were implanted into the tibia of 20 normal rabbits using $OsseoCare^{TM}$. The rabbits were sacrificed after 1 week, 4 weeks, 8 weeks and 12 weeks for implant stability analysis, removal torque analysis, histologic and histomorphometric analysis. Result : ISQ showed significant difference between Machined and RBM at first week and at 4 weeks. There was significant difference between Machined and both SLA and RBM(p<0.05) but after 8 weeks there were no significant difference between each group. In the removal torque, RBM showd significantly higher values than SLA and Machined surface at 1st week. At 4th and 12th week, there was significant difference between Machined and SLA, RBM(p<0.05). In the bone to implant contact variable, there was no significant difference between each surface treatment method. In the Machined surface group, there was no significant difference between each time interval. but in SLA group, there were significant differences between the 1st week and 12th week and in RBM group, there were significant differences between the 1st week and 8th, 12th week and between 4th and 12th week(p<0.05). The bone area showed significantly higher values in SLA and RBM compared to Machined surface 1st and 8th week and significantly higher values in SLA than Machined surface at the 4th week(p<0.05). Conclusion: The roughened surface of implants showed positive effect in the early stages of implantation and assisted in bone formation After the bone formation stage, there was no statistical difference between Machined and roughened surface groups. In dental implantation, where initial stability is critical to the success of implants, the use of roughened surface implants should assist in reducing the healing period after implantation.

On the effect of saline immersion to the removal torque for resorbable blasting media and acid treated implants (Resorbable blasting media 및 산처리한 임플란트의 제거회전력에 생리식염수를 적시는 것이 미치는 영향)

  • Kwon, Jae-uk;Cho, Sung-am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of the titanium implant soaked in saline after RBM and acid etched surface treatment on the initial osseointegration by comparing the removal torque and the surface analysis compared to the titanium implant with only RBM and acid etched surface treatment. Materials and Methods: The control group was RBM and acid etched surface treated implants (RBM + HCl), and the test group was implants soaked in saline for 2 weeks after RBM and acid etched surface treatment (RBM + HCl + Sal). The control and test group implants were placed in the left and right tibiae of 10 rabbits, respectively, and at the same time, the insertion torque (ITQ) was measured. After 10 days, the removal torque (RTQ) was measured by exposing the implant site. FE-SEM, EDS, Surface roughness and Raman spectroscopy were performed for the surface analysis of the new implant specimens used in the experiments. Results: There was significant difference in insertion torque and removal torque between control group and experimental group (P = 0.014 < 0.05). Surface roughness of experimental group is higher than control group. Conclusion: Saline soaking after RBM and acid etched surface treatment of titanium implants were positively affect the initial osseointegration as compared to titanium implants with only RBM and acid etched surface treatment.

IN VITRO STUDY ON THE EFFECTS OF THE FLOURIDE ON THE REMINERALIZATION OF ACID ETCHED ENAMEL (불소가 산부식된 법랑질의 재석회화에 미치는 영향에 관한 연구)

  • Kim, Jin-Han;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.389-399
    • /
    • 1996
  • Remineralization of acid-etched enamel across the time has been one of the curiosities in the context of the orthodontic biomechanics(Arends J. et al., IRL Press, 1, 1985), nevertheless, is so far controversial. It was the aim of this study to observe the remineralization patterns of acid-etched enamel across the time and whether the existence of fluoride might carry out any modifications. The intact buccal surfaces of the first bicuspids which was extracted for orthodontic treatment were ground smooth, and etched with a 38w/w% phosphoric acid for 60 seconds, The surface was observed by the scanning electron microscope and surface microhardness was measured after immersion in the fluoride or non-fluoride containing remineralizing solution for 0 hour, 12 hours, 1 day, 3 days, 7 days, 14 days, 28 days, and 42 days. The following results and conclusions were drawn; 1. Surface microhardness increased in both fluoride containing and non-fluoride containing solution group with time lapse. 2. In fluoride containing solution group, the surface microhardness sharply increased at the 12 hours group, on the other hand, surface microhardness increased at 3 days in non-fluoride containing solution group. 3. The difference in microhardness value between two groups manifested gradual decrease. 4. Scanning electron microphotographs disclosed that the fluoride containing solution group generated spiculate sub-stances in the 12 hours group, which was increased in number and size with time lapse. 7 days later, spherical composure was began to be produced, The spiculate substances so much increased in number that the etched enamel surface looked like flat in 42 days. 5. In non fluoride-containing solution group, there was no surface change at 42 days, perceivable in scanning electron microphotographs which could be defined as remineralization though the surface was a little rougher than the incipient etched surface. These results demonstrate that the action of the fluoride is exceedingly pertinent in the remineralization of acid-etched enamel and the remineralization process goes uninterruptedly with time lapse.

  • PDF

Effect on Shear Strength of Ceramic Surface Treatment Materials and Three Resin Cements to IPS Empress 2 (표면 처리재와 레진 시멘트가 IPS Empress 2의 전단결합강도에 미치는 영향)

  • Yae, Sun-Hae;Lee, Kyubok;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.157-170
    • /
    • 2002
  • The purpose of this study is to analyze the shear bond strength according to kinds of surface treatment agents and resin cements after acid etching of IPS Empress 2. For this purpose, test groups were classified into silane-treated bonding groups, silica-coated group and Targis link applied group. Then, nine bonding groups in total, each three groups per kind, were prepared by using three kinds of resin cements-Panavia F, Variolink II and Rely-X ARC, and thirty test specimens per group were prepared. To examine any changes in the oral environment, the shear bond strength of each test specimen was measured after dipping test for 24 hours and for five weeks, respectively, in distilled water at $37^{\circ}C$ and performing heat cycle 10,000 times in total, each 2,000 times per week, during a five weeks of dipping, under the condition similar to the oral environment. The bond failure modes were also observed by means of a scanning electron microscope. The results are summarized as follows 1. Statically significant differences between the surface conditioning materials were observed. The shear strength of the silane treatment was the highest of all three types of surface treatments(p<0.001). 2. Shear strengths varied significantly for different types of resin luting agents. But bond strength of Targis link surface treatments were not significantly different(p<0.05). 3. No significant difference of bonding strengths was found between storage time conditions(24 hours and 5 weeks). Only group II, IV, VII, IX were significantly different(p<0.05). 4. After thermocycling, the shear bond strengths of all groups were significantly decreased (p<0.05). Group III, V, VI were no significantly different. 5. On the SEM observation of fractured surfaces, all groups were shown complex failure.

A STUDY ON THE DISTRIBUTION OF CALCITONIN GENE-RELATED PEPTIDE CONTAINING NERVE FIBERS IN RAT PULP FOLLOWING DENTINAL INJURY (상아질 손상 후 흰쥐 대구치 치수의 calcitonin gene-related peptide(CGRP) 함유 신경섬유 분포에 관한 연구)

  • Moon, Joo-Hoon;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young;Cho, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.100-115
    • /
    • 1999
  • The purpose of this study was to investigate the distribution of calcitonin gene-related peptide containing nerve fibers in rat pulp after dentinl injury by means of immunohistochemistry and confocal laser scanning microscope. The Spague-Dawley rats weighing about 250-300gm were used. The animals were devided into normal control and experimental groups. Experimental animals were sacrified 1, 2, 4, 7, 10, 21days after dentinal injury (dentin cutting, and then acid etching with 35% phosphoric acid) on the maxillary molar teeth. The maxillary teeth and alveolar bone were removed and immersed in the 4% paraformaldehyde in 0.1M phosphate buffer (pH 7.4), then were decalcified with 15% formic acid for 10 days. Serial frozen $50{\mu}m$ thick sections were cut on a cryostat. The rabbit CGRP antibody was used as a primary antibody with a dilution of 1:2000 in 0.01M PB. The sections were incubated for 48 hours at $4^{\circ}C$, and placed into biotinylated antirabbit Ig G as a secondary anti body with dilution of 1:200 in 0.01M PB and incubated in ABC(avidin-biotin complex). The peroxidase reaction was visualized by incubating the sections in 0.05% 3,3 diaminobenzidine tetrahydrochloride containing 0.02% $H_2O_2$. For the confocal laser scanning microscopic examination, Primary antibody reaction was same as immunoperoxidase stainning, but fluorescein isothiocyanate(FITC)-conjugate antirabbit IgG as a secondary antibody was used. The confocal laser scanning microscope was used for the examination. A series of images of optical sections was collected with a 20x objective at $3{\mu}m$ intervals throughout the depth of specimen. FITC fluerescence was registrated through a 488nm and 568nm excitation filter, and images were saved on optical disk. The stereoscopic images and three dimentionnal images were reconstructed by computer software, and then were analyzed. The results were as follows : 1. In normal control group, CGRP containing nerve fibers were coursed through the root with very little branching, and then formed a dense network of terminals in coronal pulp. 2. A slight increase in CGRP containing nerve fibers at 1 and 2day postinjury was noted subjacent to the injury site. In the 4day group, there were an extensive increase in the number of reactive fibers, followed by a partial return toward normal levels at 7~10 day postinjury, and return by 21days. 3. The sprouting of the CGRP containing nerve fibers was evident within 2day after dentinal injury, and by 4days there was a maximal increased, but was decreased at 7days and returned to normal 10~21 day postinjury. 4. In confocal laser scanning microscopic exammination, the distinct distribution pattern and sprouting reaction of CGRP containing nerve fibers were observed in stereoscopic images and three dimentional images. These results suggest that CGRP containing nerve fiber can be important role in the response to dental injury and pain regulation.

  • PDF

INFLUENCE OF LIGHT IRRADIATION OVER SELF-PRIMING ADHESIVE ON DENTIN BONDING (상아질접착제에 대한 광조사가 접착에 미치는 영향)

  • 류현욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.5
    • /
    • pp.409-417
    • /
    • 2001
  • The purpose of this study was to investigate the influence of light irradiation over self-priming adhesive on dentin bonding. After acid etching the exposed dentin, a self-priming adhesive (Prime&Bond$^{\circledR}$NT dental adhesive system Dentsply DeTrey, GmbH, Konstanz, Germany) was applied and light irradiation was done for 20 sec with regular intensity (600 mW/$\textrm{cm}^2$) in group I and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in group III. No light irradiation was done over self-priming adhesive in groups II and IV. Composite resin was added on the self-priming adhesive and irradiated for 40 sec with regular intensity (600 mW/$\textrm{cm}^2$) in groups I and II and for 3 sec with ultra-high intensity (1930 mW/$\textrm{cm}^2$) in groups III and IV. To see the effect of light curing time on dentin bonding, another 3 group specimens were prepared. Without light-irradiation over self-priming adhesive, added composite resin was irradiated for 3, 6, or 12 sec with ultra-high intensity light. After bonded specimens were stored in 37$^{\circ}C$ distilled water for 24 hours, shear bond strength were measured using a universal testing machine (4202, Instron, Instron Co., U.S.A.) and fractured surfaces were examined under a stereomicroscope (SZ-PT Olympus, Japan). Statistical analysis were done with one-way, two-way ANOVA and chi-square test. The results were as follows : 1. The shear bond strengths from the groups irradiated over self-priming adhesive were significantly higher than those from the groups without irradiation (p<0.05). 2. There was no significant shear bond strength difference between regular intensity light irradiation groups and ultra-high intensity ones (p>0.05). 3. There was no significant shear bond strength difference among various irradiation time groups with ultra-high intensity ones (p>0.05). 4. In stereomicroscopic examination of fractured surfaces, adhesive-cohesive mixed failure mode was mostly seen in all groups, and there was no significant difference in failure mode among groups (p>0.05).

  • PDF

Effect of storage condition of resin cement on shear bond strength of the orthodontic bracket (레진시멘트의 보관 조건이 치열교정용 브라켓의 전단접착강도에 미치는 영향)

  • Seul-Gi, Yi;Jin-Woo, Kim;Se-Hee, Park;Yoon, Lee;Eung-Hyun, Kim;Kyung-Mo, Cho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.189-195
    • /
    • 2022
  • Purpose: For orthodontic bracket bonding, light curing resin cement is widely used because the process is convenient, and it can be polymerized at the desired time. This study compared the difference of bonding strength of orthodontic resin cement according to storage condition. Materials and Methods: After acid etching the bovine enamel surface with 37% phosphoric acid, 15 orthodontic brackets for mandible incisors were bonded with Ortho Connect and Orthomite LC according to following three conditions; 1) Immediate after 4℃ refrigeration for 3 months (IR), 2) One day room temperature after 4℃ refrigeration for 3 months (OR), 3) Room temperature for 3 months (RT). The shear bond strength was measured with a universal material tester and failure pattern of the specimen was observed. Two-way ANOVA and One-way ANOVA were used at the 95% significance level. Results: Ortho Connect that was applied immediately after refrigeration showed the maximum shear bond strength. Orthomite that was applied immediately after refrigeration showed the lowest shear bond strength, and the group stored at room temperature for three months showed the highest shear bond strength, and the difference between the two groups was significant. Conclusion: Ortho Connect can be used without worrying about bond strength even if it is used immediately after refrigeration, but Orthomite should be kept at room temperature sufficiently after refrigeration.