• Title/Summary/Keyword: Dental error

Search Result 191, Processing Time 0.025 seconds

Comparison of the Internal Fitness of Prostheses Fabricated with Non-Contact Extra-Oral Scanner and Intra-Oral Video Scanner (비접촉식 구강외 스캐너와 비디오방식 구강내 스캐너를 이용하여 제작된 보철물의 내면정확도 비교)

  • Park, Jin-Young;Kim, Ji-Hwan;Jeong, Il-Do;Lee, Gwang-Young;Kim, Won-Soo
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.263-269
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate the internal fitness of prostheses fabricated with non-contact extra-oral scanner and those fabricated with intra-oral video scanner, with a comparative accuracy analyses of their precision and trueness. Methods: A polymethyl methacrylate (PMMA) model was fabricated by replicating a master model. The prostheses in the first group were fabricated based on the PMMA model with an intra-oral video scanner (IVS group). Following the fabrication of work models with Type IV Stone that were based on the PMMA model, the prostheses in the second group were fabricated with a non-contact extra-oral scanner (ENB group). The precision and trueness of the prostheses were calculated from comparisons of the three-dimensional images of the internal surfaces of the prostheses and those of the master model. Kruskal-Wallis tests were used to determine the statistical significance, with the level of type 1 error set at 0.05. Results: Trueness (P < 0.009) and precision (P < 0.001) did not differ significantly between the ENB and IVS groups. The IVS group exhibited lower trueness values and larger precision values than the ENB group. Conclusion: Although no significant differences were found in the internal fitness of the prostheses that were fabricated by the two different scanners, the intraoral video scanner-fabricated prostheses had better trueness, whereas the non-contact extra-oral scanner-fabricated prostheses had better precision.

Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique

  • Kang, Seen-Young;Park, Jung-Hyun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.354-360
    • /
    • 2018
  • PURPOSE. To compare and analyze trueness and precision of provisional crowns made using stereolithography apparatus and subtractive technology. MATERIALS AND METHODS. Digital impressions were made using a master model and an intraoral scanner and the crowns were designed with CAD software; in total, 22 crowns were produced. After superimposing CAD design data and scan data using a 3D program, quantitative and qualitative data were obtained for analysis of trueness and precision. Statistical analysis was performed using normality test combined with Levene test for equal variance analysis and independent sample t-test. Type 1 error was set at 0.05. RESULTS. Trueness for the outer and inner surfaces of the SLA crown (SLAC) were $49.6{\pm}9.3{\mu}m$ and $22.5{\pm}5.1{\mu}m$, respectively, and those of the subtractive crown (SUBC) were $31.8{\pm}7.5{\mu}m$ and $14.6{\pm}1.2{\mu}m$, respectively. Precision values for the outer and inner surfaces of the SLAC were $18.7{\pm}6.2{\mu}m$ and $26.9{\pm}8.5{\mu}m$, and those of the SUBC were $25.4{\pm}3.1{\mu}m$ and $13.8{\pm}0.6{\mu}m$, respectively. Trueness values for the outer and inner surfaces of the SLAC and SUBC showed statistically significant differences (P<.001). Precision for the inner surface showed significance (P<.03), whereas that for the outer surface showed no significance (P<.58). CONCLUSION. The study demonstrates that provisional crowns produced by subtractive technology are superior to crowns fabricated by stereolithography in terms of accuracy.

Relationship between socioeconomic status and periodontal disease using Structural Equation Modeling (구조방정식 모델을 이용한 사회경제적 수준과 치주질환과의 연관성)

  • Hwang, Su-Yeon;Yang, Jin-Young;Kim, Ki-Eun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.6
    • /
    • pp.979-986
    • /
    • 2018
  • Objectives: The purpose of this study was to investigate the relationship between socioeconomic status and periodontal disease. Methods: The data used for the analysis were obtained from the sixth Korean National Health and Nutrition Examination Survey (2015). A total of 5,632 adults, aged over 19 years, were included in the study. This study analyzed data relating to socioeconomic status and health behaviors. The socioeconomic status was defined as an exogenous factor. Periodontal disease was the endogenous variable. Health behavior was a mediating variable. The study hypotheses were tested using Structural Equation Modeling analysis with Mplus 7.0 software. Results: According to the model fit test, the associated root-mean-square error was 0.05 (90% CI: 0.046-0.059); comparative fit index was 0.93; Tucker-Lewis index was 0.88; and standardized root-mean-square residual was 0.03. We found that socioeconomic status had significant effects on health behaviors (${\beta}=0.304$, p<0.001) and periodontal disease (${\beta}=-0.289$, p=0.001). Moreover, health behaviors had significant effects on periodontal diseases (${\beta}=0.143$, p<0.001). The analysis of a possible relationship between socioeconomic status and periodontal disease using path analysis demonstrated health behaviors difficulties, along with direct and indirect effects, further increased the risk of periodontal disease. Conclusions: The findings suggest that future interventions for the prevention of periodontal disease should consider health behavior.

PATHWAYS AND GENES OF DNA DOUBLE-STRAND BREAK REPAIR ASSOCIATED WITH HEAD AND NECK CANCER (DNA 이중나선파손의 수복 과정과 이와 연관된 두경부암 발생 유전자)

  • Oh, Jung-Hwan;Lee, Deok-Won;Ryu, Dong-Mok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • DNA double-strand breaks (DSBs) occur commonly in the all living and in cycling cells. They constitute one of the most severe form of DNA damage, because they affect both strand of DNA. DSBs result in cell death or a genetic alterations including deletion, loss of heterozygosity, translocation, and chromosome loss. DSBs arise from endogenous sources like metabolic products and reactive oxygen, and also exogenous factors like ionizing radiation. Defective DNA DSBs can lead to toxicity and large scale sequence rearrangement that can cause cancer and promote premature aging. There are two major pathways for their repair: homologous recombination(HR) and non-homologous end-joining(NHEJ). The HR pathway is a known "error-free" repair mechanism, in which a homologous sister chromatid serves as a template. NHEJ, on the other hand, is a "error-prone" pathway, in which the two termini of the broken DNA molecule are used to form compatible ends that are directly ligated. This review aims to provide a fundamental understanding of how HR and NHEJ pathways operate, cause genome instability, and what kind of genes during the pathways are associated with head and neck cancer.

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients

자가 치아 이식술에 사용되는 Computer Aided Rapid Prototyping model(CARP model)의 실제 치아에 대한 오차

  • Lee, Seong-Jae;Kim, Ui-Seong;Kim, Gi-Deok;Lee, Seung-Jong
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.115-122
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the dimensional errors between real tooth, 3D CT image and CARP model. Materials and Methods : Two maxilla and two mandible block bones with intact teeth were taken from two cadavers. Computed tomography was taken either in dry state and in wet state. After then, all teeth were extracted and the dimensions of the real teeth were measured using a digital caliper at mesio-distal and bucco-lingual width both in crown and cervical portion. 3D CT image was generated using the V-works $4.0^{TM}$ (Cybemed Inc., Seoul, Korea) software. Twelve teeth were randomly selected for CARP model fabrication. All the measurements of 3D Ct images and CARP models were made in the same manner of the real tooth group. Dimensional errors between real tooth, 3D CT image model and CARP model was calculated. Results : 1) Average of absolute error was 0.199 mm between real teeth and 3D CT image model, 0.169 mm between 3D CT image model and CARP model and 0.291 mm between real teeth and CARP model, respectively. 2) Average size of 3D CT image was smaller than real teeth by 0.149 mm and that of CARP model was smalier than 3D CT image model by 0.067mm. Conclusion : Within the scope of this study, CARP model with the 0.291 mm average of absolute eror can aid to enhance the success rate cf autogenous tooth transplantation due to the increased accuracy of recipient bone and donor tooth.

  • PDF

Evaluation of Fourier Transform Near-infrared Spectrometer for Determination of Oxalate in Standard Urinary Solution (표준 요 시료 중 Oxalate의 측정을 위한 FT-NIR 분광기의 유용성 검정)

  • Kim, Yeong-Eun;Hong, Su-Hyung;Kim, Jung-Wan;Lee, Jong-Young
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.2
    • /
    • pp.165-170
    • /
    • 2006
  • Objectives : The determination of oxalate in urine is required for the diagnosis and treatment of primary hyperoxaluria, idiopathic stone disease and various intestinal diseases. We examined the possibility of using Fourier transform near-infrared (FT-NIR) spectroscopy analysis to quantitate urinary oxalate. The practical advantages of this method include ease of the sample preparation and operation technique, the absence of sample pre-treatments, rapid determination and noninvasiveness. Methods : The range of oxalate concentration in standard urine solutions was $0-221mg/{\ell}$. These 80 different samples were scanned in the region of 780-1,300 nm with a 0.5 nm data interval by a Spectrum One NTS FT-NIR spectrometer. PCR, PLSR and MLR regression models were used to calculate and evaluate the calibration equation. Results : The PCR and PLSR calibration models were obtained from the spectral data and they are exactly same. The standard error of estimation (SEE) and the % variance were $10.34mg/{\ell}$ and 97.86%, respectively. After full cross validation of this model, the standard error of estimation was $5,287mg/{\ell}$, which was much smaller than that of the pre-validation. Furthermore, the MCC (multiple correlation coefficient) was 0.998, which was compatible with the 0.923 or 0.999 obtained from the previous enzymatic methods. Conclusions : These results showed that FT-NIR spectroscopy can be used for rapid determination of the concentration of oxalate in human urine samples.

A fully deep learning model for the automatic identification of cephalometric landmarks

  • Kim, Young Hyun;Lee, Chena;Ha, Eun-Gyu;Choi, Yoon Jeong;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.299-306
    • /
    • 2021
  • Purpose: This study aimed to propose a fully automatic landmark identification model based on a deep learning algorithm using real clinical data and to verify its accuracy considering inter-examiner variability. Materials and Methods: In total, 950 lateral cephalometric images from Yonsei Dental Hospital were used. Two calibrated examiners manually identified the 13 most important landmarks to set as references. The proposed deep learning model has a 2-step structure-a region of interest machine and a detection machine-each consisting of 8 convolution layers, 5 pooling layers, and 2 fully connected layers. The distance errors of detection between 2 examiners were used as a clinically acceptable range for performance evaluation. Results: The 13 landmarks were automatically detected using the proposed model. Inter-examiner agreement for all landmarks indicated excellent reliability based on the 95% confidence interval. The average clinically acceptable range for all 13 landmarks was 1.24 mm. The mean radial error between the reference values assigned by 1 expert and the proposed model was 1.84 mm, exhibiting a successful detection rate of 36.1%. The A-point, the incisal tip of the maxillary and mandibular incisors, and ANS showed lower mean radial error than the calibrated expert variability. Conclusion: This experiment demonstrated that the proposed deep learning model can perform fully automatic identification of cephalometric landmarks and achieve better results than examiners for some landmarks. It is meaningful to consider between-examiner variability for clinical applicability when evaluating the performance of deep learning methods in cephalometric landmark identification.

A Study on Job Stress of Dental Technician (치과기공사의 업무스트레스에 대한 연구)

  • Lee, Deok-Su;Kwak, Dong-Ju;Nam, Sang-Yong
    • Journal of Technologic Dentistry
    • /
    • v.24 no.1
    • /
    • pp.51-63
    • /
    • 2002
  • The purpose of this study was to be of use for getting rid of job stress from dental technicians, by examining how much they were stressed out at work place as one of the professional medical personnels. The subjects in this study were 255 selected dental technicians who were working in the region of Taegu. The one-on-one interview was conducted from March 1 to 30, 2001, with structured questionnaire. The questionnaire sued in this study included 19 question items about the general characteristics and 29 items regarding job stress. The job stress was categorized into seven subareas based on earlier studies and considering the job situations of dental technicians: heavy workload, job conflicts, improper treatment, role and job knowledge, human relations, physical environment and personal matters. The job stress extent was measured on five-point Likert scale that is widely used in social science: one point for no stress, two for little stress, three for so-so, four for a little stress, and five for severe stress. Therefore, a higher point means a severer job stress. The reliability of the questionnaire turned out very good with Cronbach a = 0.9272. The findings of this study were as follows: 1. The general characteristics of the dental technicians investigated could be described as below: (1) By gender, 80.4% of the dental technicians were male, and 50.2%, the largest percentage, were in their 20s, followed by those in their 30s, those in their 40s, and those in their 50s in the order named. (2) The most common work place was dental technician shop(92.5%), followed by dental technology room in dental hospital or clinic and in general hospital in the order named. The primary duties were coating materials work(30.6%), followed by sculpture, grinding, partial and full denture and orthodontics in the order named. 2. The most larges (1) The most largest motivation to be a dental technician was its being a professional(33.7%), followed by the advice from others, their own aptitude, and good economic treatment in the order named. 3. Their job stress could be explained as below: (1) Their collective job stress average was 3.96$^{\circ}{\ae}$0.50 on the basis of 5 point, which showed that they were exposed to a fairly severe job stress. (2) By area, they were most stressed out from heavy workload (4.12), and they also were severely stressed from role and job knowledge(4.02) and personal matters(4.00). (3) By situation, they were most stressed when the disagreement of prosthesis that results from a specific error is unconditionally attributed to them(4.43). And they were also stressed a lot when their workload increases due to the rework(4.38), when a dentist asks something difficult for them to resolve(4.20), when heavy workload makes their working hours irregular and it's impossible to lead a personal life or have leisure time(4.16), and when they are o work for an excessively short time(4.16). This fact indicated that most of the dental technicians were exposed to a lot of stress in conjunction with job performance. 4. The main duties they took charge of didn't make any significant difference to their job stress, but yielded a significant difference to the extent of job stress in individual areas and the order of the most stressful one. Those who were engaged in grinding were most stressed from their own matters, whereas heavy workload was most stressful for those who were engaged in the other types of works. 5. As a result of seeing if their personal characteristics yielded any differences to job stress, the personal characteristics that made their job stress vary significantly were working hours, motivation of being a dental technician, job satisfaction and willingness to continue doing dental technology works. There was a tendency that longer working hours led to severer job stress, and those who chose to be a dental technician according to their own aptitude were less stressed than the others who became a dental technician because of economic reason or advices from others. And the people who were satisfied with their job were exposed to less job stress than the others who weren't, and those who had an intention to keep that job as much as possible were less stressed, compared to the others who hadn't.

  • PDF

Reverse engineering technique on the evaluation of impression accuracy in angulated implants (경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법)

  • Jung, Hong-Taek;Lee, Ki-Sun;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.261-270
    • /
    • 2021
  • Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.