• 제목/요약/키워드: Dental error

검색결과 193건 처리시간 0.03초

치과건강보험 요양급여비용 청구에 관한 교육요구도 조사 -대전·충청지역을 중심으로- (The investigation of the degree of the request of the education about the claim for the medical expenses in the dentistry health insurance - mainly in the Daejeon, Chungcheong area -)

  • 남용옥;김성희;김민자
    • 한국치위생학회지
    • /
    • 제11권3호
    • /
    • pp.325-341
    • /
    • 2011
  • Objectives : This research has investigated the reality of the education of the claim and the degree of the education for the claimed of the dentistry recuperation organization in the Daejeon and Chuncheong are for the improvement of the problem in the medical expenses. Methods : It use as a basic data for the vitalizations of the education and performed the survey in the dentistry recuperation organization in the Daejeon and ChungCheong Nam BukDo which are registered in the evaluating organization for judging the health insurance in the present May 2010, and concluded just like the below. Results : 1. The education of the claim in the requirer in the dentistry recuperation organization, and the education of the claim was especially lacking when the dentist was studying in the university, and the dental hygienist had the similar educational experience in the school and the clinic (p<0.05) 2. Most of the requirer in the dental recuperation organization was hoping to get the education related to the claim work, but the dentist and the nurse's aid was relatively low (p<0.05) 3. For fixing the error of the claim, the participation and the extension of the judging standard of the insurance was the highest among the university subordinate dental hospital/dental hospital, but the health center was relatively low (p<0.05). 4. The dentist feels the economic burden in employing the special employee because the raising of the special judging people, compared to others, but the staffs such as the dental hygienist preferred it as one of ways to fix the error of the claim of the dental insurance (p<0.05) 5. Both dentists and the dental hygienist said proper time to teach the insurance was all needed in the school, and the clinic, but other workers relatively believed it should be held in the clinic (p<0.05). 6. The important factors to decide the participation of the lecture was in order of the contents of the lecture, the place of the lecture, the amount for the lecture, the superintendent of the lecture, whether it has gone through the educational score, and whether it has passed the conserving educational score was relatively less important in the university subordinate dentist/dentist, but the medical center was very effective as 4.50 (p<0.05) 7. Health Insurance Review and assessment service was very high as the managing department for supplying the lecture and the information, 70.5%, and the next was the Korean Dental Association/ Korean dental hygiene association, but dentists were preferring the association to manage in than the Health Insurance Review and assessment service to manage (p<0.05) 8. In preferring lecture for the inquiring the insurance, periodontal surgery was the highest as 4.51, the diagnosis standard for injection was high in the university subordinate hospital/dentists, and the more the year of the insurance inquiry, the less the doctor who was hoping for the lecture about the basic treatment. Conclusions : Taken together, it is decided that the inquiry education about the medical expense in the dentist, so the consistent and systematic education should be held to the related people, and from this, it is thought to reduce the problem of the inquiry of the medical expenses by fostering the knowledge and supplying the information which are related to the inquiry of the dentists.

Effects of inter-implant distance on the accuracy of intraoral scanner: An in vitro study

  • Thanasrisuebwong, Prakan;Kulchotirat, Tharathip;Anunmana, Chuchai
    • The Journal of Advanced Prosthodontics
    • /
    • 제13권2호
    • /
    • pp.107-116
    • /
    • 2021
  • PURPOSE. Several studies focused on the accuracy of intra-oral scanners in implant dentistry, but the data of inter-implant distances were not widely mentioned. Therefore, this study aimed to evaluate the effect of distance between two implants on the surface distortion of scanned models generated by intra-oral scanners. MATERIALS AND METHODS. Three models with the distances between two fixed scan bodies of 7, 14, and 21 mm were fabricated and scanned with a highly precise D900L dental laboratory scanner as reference models. Fifteen scans were performed with TRIOS3 and CEREC Omnicam intra-oral scanners. Trueness, precision, and angle deviation of the test models were analyzed (α=.05). RESULTS. There was a significant difference among inter-implant distances in both intraoral scanners (P<.001). The error of trueness and precision increased with the increasing inter-implant length, while the angle deviation did not show the same trend. A significant difference in the angle deviation was found among the inter-implant distance. The greatest angle deviation was reported in the 14-mm group of both scanners (P<.05). In contrast, the lowest angle deviation in the 21-mm group of the TR scanner and the 7-mm of the CR scanner was reported (P<.001). CONCLUSION. The inter-implant distance affected the accuracy of intra-oral scanner. The error of trueness and precision increased along with the increasing distance between two implants. However, the distortions were not clinically significant. Regarding angle deviation, the clinically significant angle deviation may be possible when using intra-oral scanners in the partially edentulous arch.

Dental age estimation in Indonesian adults: An investigation of the maxillary canine pulp-to-tooth volume ratio using cone-beam computed tomography

  • Khamila Gayatri Anjani;Rizky Merdietio Boedi;Belly Sam;Fahmi Oscandar
    • Imaging Science in Dentistry
    • /
    • 제53권3호
    • /
    • pp.221-227
    • /
    • 2023
  • Purpose: This study was performed to develop a linear regression model using the pulp-to-tooth volume ratio (PTVR) ratio of the maxillary canine, assessed through cone-beam computed tomography (CBCT) images, to predict chronological age (CA) in Indonesian adults. Materials and Methods: A sample of 99 maxillary canines was collected from patients between 20 and 49.99 years old. These samples were obtained from CBCT scans taken at the Universitas Padjadjaran Dental Hospital in Indonesia between 2018 and 2022. Pulp volume (PV) and tooth volume (TV) were measured using ITK-SNAP, while PTVR was calculated from the PV/TV ratio. Using RStudio, a linear regression was performed to predict CA using PTVR. Additionally, correlation and observer agreement were assessed. Results: The PTVR method demonstrated excellent reproducibility, and a significant correlation was found between the PTVR of the maxillary canine and CA(r= -0.74, P<0.01). The linear regression analysis showed an R2 of 0.58, a root mean square error of 5.85, and a mean absolute error of 4.31. Conclusion: Linear regression using the PTVR can be effectively applied to predict CA in Indonesian adults between 20 and 49.99 years of age. As models of this type can be population-specific, recalibration for each population is encouraged. Additionally, future research should explore the use of other teeth, such as molars.

DLP 프린터로 제작한 상악 및 하악 의치상의 항온수조 침적에 따른 진실도(trueness) 평가 (Evaluation of trueness of maxillary and mandibular denture bases produced with a DLP printer by immersion in a constant temperature water bath)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제46권2호
    • /
    • pp.28-35
    • /
    • 2024
  • Purpose: To evaluate the three-dimensional trueness of upper and lower denture bases produced using a digital light processing (DLP) printer and immersed in a constant-temperature water bath. Methods: An edentulous model was prepared and fitted with denture bases and occlusal rims manufactured using base plate wax. After scanning the model, denture bases, and occlusal rims, complete denture designs were created. Using the designs and a DLP printer, 10 upper and 10 lower complete dentures were manufactured. Each denture was scanned before (impression surface of upper denture base before constant temperature water bath [UBC] and impression surface of lower denture base before constant temperature water bath [LBC] groups) and after (impression surface of upper denture base after constant temperature water bath [UAC] and impression surface of lower denture base after constant temperature water bath [LAC] groups) immersion in the constant-temperature water bath. Scanned files were analyzed by comparing reference and scanned data, with statistical analysis conducted using the Kruskal-Wallis test (α=0.05). Results: Statistical analysis revealed no significant differences between the UBC and LBC groups, nor between the UAC and LAC groups (p>0.05). However, significant differences were observed between the UBC and UAC groups and between the LBC and LAC groups, i.e., before and after the constant-temperature water bath for both maxillary and mandibular denture bases (p<0.05). Conclusion: Denture bases not immersed in the constant-temperature water bath (UBC and LBC groups) exhibited error values within 100 ㎛, whereas those immersed in the water bath (UAC and LAC groups) showed error values exceeding 100 ㎛.

치아크기 계측오차에 관한 연구 (A study on the error of tooth size measurements)

  • 심은주;황현식;문재동
    • 대한치과교정학회지
    • /
    • 제29권4호
    • /
    • pp.491-501
    • /
    • 1999
  • 본 연구는 석고모형 분석 중 치아크기 측정시 발생할 수 있는 오차를 줄이고 측정의 재현도와 정확성을 향상시키는데 도움이 될 수 있는 방안을 모색하고자 시행되었다. 치아밀집 치열 특징을 지닌 상하악 20조의 석고모형을 대상으로 하여, 5명의 조사자가 각 치아의 근원심 폭경을 디지털 버니어 캘리퍼스를 사용하여 2주 간격으로 3회 측정하여 실험측정치를 얻은 다음, 측정에 이용된 석고모형을 근원심 접촉점 부위에서 개개 치아로 분리한 후, 마이크로미터를 이용하여 측정한 표준치와 비교$\cdot$분석하여 다음과 같은 결과를 얻었다. 1. 3회 측정에 따른 재현도는 조사자별 치아별로 큰 차이를 나타내지 않았다. 2. 표준치와 비교한 계측오차는 조사자별 또는 치아별로 차이를 보였다. 3. 표준치와의 오차는 전치에서 구치로 갈수록 증가하여 제1대구치에서 가장 큰 차이를 나타내었다. 4. 표준치와 비교시 전반적으로 작게 측정하는 경향을 보였으며 이에 대한 치아별, 조사자별 차이가 두드러졌다. 5. 전반적인 오차 발생 정도는 치아밀집 정도와 유의한 상관성을 보이지 않았다. 이상의 결과는 교정증례 분석시 치아크기 계측오차 발생 가능성의 고려가 필요함을 시사하였다.

  • PDF

삼차원 전산화단층촬영사진과 측모두부 방사선규격사진의 계측자에 따른 계측오차에 대한 비교분석 (Comparison of the observer reliability of cranial anatomic landmarks based on cephalometric radiograph and three-dimensional computed tomography scans)

  • 김재영;이동근;이상한
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제36권4호
    • /
    • pp.262-269
    • /
    • 2010
  • Introduction: Accurate diagnosis and treatment planning are very important for orthognathic surgery. A small error in diagnosis can cause postoperative functional and esthetic problems. Pre-existing 2-dimensional (D) chephalogram analysis has a high likelihood of error due to its intrinsic and extrinsic problems. A cephalogram can also be inaccurate due to the limited anatomic points, superimposition of the image, and the considerable time and effort required. Recently, an improvement in technology and popularization of computed tomography (CT) provides patients with 3-D computer based cephalometric analysis, which complements traditional analysis in many ways. However, the results are affected by the experience and the subject of the investigator. Materials and Methods: The effects of the sources human error in 2-D cephalogram analysis and 3-D computerized tomography cephalometric analysis were compared using Simplant CMF program. From 2008 Jan to 2009 June, patients who had undergone CT, cephalo AP, lat were investigated. Results: 1. In the 3 D and 2 D images, 10 out of 93 variables (10.4%) and 11 out 44 variables (25%), respectively, showed a significant difference. 2. Landmarks that showed a significant difference in the 2 D image were the points frequently superimposed anatomically. 3. Go Po Orb landmarks, which showed a significant difference in the 3 D images, were found to be the artificial points for analysis in the 2 D image, and in the current definition, these points cannot be used for reproducibility in the 3 D image. Conclusion: Generally, 3-D CT images provide more precise identification of the traditional cephalometric landmark. Greater variability of certain landmarks in the mediolateral direction is probably related to the inadequate definition of the landmarks in the third dimension.

치위생과정(ADPIE)의 임상적용 가능성과 실천방안 모색 (A Study on Clinical Feasibility and Practical Strategies for Dental Hygiene Process (ADPIE))

  • 이주영;한경순
    • 치위생과학회지
    • /
    • 제14권4호
    • /
    • pp.433-441
    • /
    • 2014
  • 치위생과정을 임상에서 활용하고 정착시키기 위한 방안을 모색하고자 SEM을 이용하여 치과위생사 업무 자율성과 치위생과정의 임상적용 기대효과 및 장애요인이 임상적용 의향에 미치는 효과를 분석하고, 치위생과정에 대한 태도가 임상적용 의향에 미치는 매개효과를 검증한 결과는 다음과 같다. 가설적 모형은 ${\chi}^2=421.67$, GFI=0.858, CFI=0.915, TLI=0.896, RMR=0.039, RMSEA=0.099로 적합한 것으로 나타났다. SEM을 검증한 결과, 치과위생사 업무 자율성(${\beta}=0.398$, p<0.05)과 치위생과정 기대효과(${\beta}=0.363$, p<0.01)는 치위생과정 태도에 정(+)의 방향으로, 치위생과정 태도(${\beta}=0.678$, p<0.05)는 임상적용 의향에 정(+)의 방향으로 영향을 미치는 것으로 나타났다. 치과위생사 업무 자율성(${\beta}=0.269$, p<0.05)과 기대효과(${\beta}=0.246$, p<0.01)는 치위생과정 태도를 매개로 임상적용 의향에 간접적인 영향을 미치는 것으로 확인되었다. 위의 결과로 치과위생사의 업무 자율성, 치위생과정에 대한 기대효과와 태도는 임상적용 의향에 영향을 미치는 중요한 요인임을 확인하였다. 따라서 치위생과정을 임상에 정착시키기 위해서는 치과위생사 역량을 제고하여 업무 자율성을 확보해야 하며, 치위생과정에 대한 경영적 효과와 가치에 대한 객관적인 검증이 이루어져야 한다.

일부 치과 종사자의 치과 건강보험의 지식수준에 미치는 요인에 대한 융합연구 (An Convergence Study of the Factors Affecting the Knowledge Level of Dental Health Insurance for Some Dental Workers)

  • 이선미;손화경
    • 한국융합학회논문지
    • /
    • 제12권10호
    • /
    • pp.137-144
    • /
    • 2021
  • 이 연구는 치과 종사자들의 치과 건강보험 교육경험 및 교육요구도와 산정기준에 대한 지식수준에 미치는 요인을 분석하는 것을 목적으로 한다. 대구·경북 지역의 치과 종사자들을 연구대상으로 하였으며, 구글 설문지를 활용한 온라인 조사를 실시하였다. 연구대상자의 일반적 특성, 교육 경험, 교육 경험 및 교육요구도에 따른 지식수준을 알아보기 위하여 빈도분석과 교차분석 및 ANOVA분석을 사용하였다. 분석 결과, 치과 건강보험에 대한 지식수준 조사에서 청구 프로그램에서 자동으로 처리를 해주거나 오류창으로 알려주는 경우의 산정기준에 대한 오답률이 높았다. 근무경력이 많고 치과에서 보험청구를 하고 있거나 최근 6개월 동안 치과보험 교육 경험이 있는 대상자들에서 산정기준에 대한 지식수준이 높았다. 결론적으로, 정기적인 치과 건강보험 교육을 통해 변경되는 산정기준을 숙지하도록 해야만 정확하고 올바른 보험청구가 가능하다고 보여진다. 이 연구는 치과 종사자들의 전문적인 치과 보험청구를 위한 교육체계 마련에 기초자료를 제공할 것으로 기대한다.

Prediction accuracy of incisal points in determining occlusal plane of digital complete dentures

  • Kenta Kashiwazaki;Yuriko Komagamine;Sahaprom Namano;Ji-Man Park;Maiko Iwaki;Shunsuke Minakuchi;Manabu, Kanazawa
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.281-289
    • /
    • 2023
  • PURPOSE. This study aimed to predict the positional coordinates of incisor points from the scan data of conventional complete dentures and verify their accuracy. MATERIALS AND METHODS. The standard triangulated language (STL) data of the scanned 100 pairs of complete upper and lower dentures were imported into the computer-aided design software from which the position coordinates of the points corresponding to each landmark of the jaw were obtained. The x, y, and z coordinates of the incisor point (XP, YP, and ZP) were obtained from the maxillary and mandibular landmark coordinates using regression or calculation formulas, and the accuracy was verified to determine the deviation between the measured and predicted coordinate values. YP was obtained in two ways using the hamularincisive-papilla plane (HIP) and facial measurements. Multiple regression analysis was used to predict ZP. The root mean squared error (RMSE) values were used to verify the accuracy of the XP and YP. The RMSE value was obtained after crossvalidation using the remaining 30 cases of denture STL data to verify the accuracy of ZP. RESULTS. The RMSE was 2.22 for predicting XP. When predicting YP, the RMSE of the method using the HIP plane and facial measurements was 3.18 and 0.73, respectively. Cross-validation revealed the RMSE to be 1.53. CONCLUSION. YP and ZP could be predicted from anatomical landmarks of the maxillary and mandibular edentulous jaw, suggesting that YP could be predicted with better accuracy with the addition of the position of the lower border of the upper lip.

임프란트 식립오류가 최종 보철물의 성공에 미치는 영향: 구강악안면외과의사에 의해 식립된 치과임프란트에 대한 보철의사의 주관적 평가 (Influence of implant misplacement on the success of the final prosthesis: Subjective evaluation by a prosthodontist of dental implants placed by an oral and maxillofacial surgeon)

  • 김영균;황정원;이효정;여인성;윤필영
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권6호
    • /
    • pp.437-441
    • /
    • 2009
  • Purpose: In many cases, the erroneous placement of a dental implant brings about undesirable results. Here, the effect of dental implant placement on the success of the final prosthesis was evaluated from the point of view of the prosthodontist. Materials and Methods: All surgical operations were performed by the same oral surgeon with the same surgical protocol and all prosthodontic procedures were performed by the same prosthodontist. The problems faced by the prosthodontist, their causes, and their effect on prosthesis success were identified. The success of the final prostheses was evaluated by the same prosthodontist. Results: Only 53% (238 implants in 105 patients) of dental implants were not associated with prosthodontic problems. Multiple implant placement (more than three implants) was associated more frequently with prosthodontic problems. Conclusions: The data indicate that the satisfactory construction of a prosthesis is highly dependent on the placement of the dental implant in the best possible position. It is strongly recommended that the oral surgeon and the prosthodontist engage in pre-operative discussions to establish a top-down treatment plan, as this will improve implant placement and ultimately the success of the prosthesis.