CAD/CAM splint based on soft tissue 3D simulation for treatment of facial asymmetry

  • Tominaga, Kazuhiro;Habu, Manabu;Tsurushima, Hiroki;Takahashi, Osamu;Yoshioka, Izumi
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.4.1-4.6
    • /
    • 2016
  • Background: Most cases of facial asymmetry involve yaw deformity, and determination of the yaw correction level is very difficult. Methods: We use three-dimensional soft tissue simulation to determine the yaw correction level. This three-dimensional simulation is based on the addition of cephalometric prediction to gradual yaw correction. Optimal yaw correction is determined visually, and an intermediate splint is fabricated with computer-aided design and computer-aided manufacturing. Application of positioning devices and the performance of horseshoe osteotomy are advisable. Results: With this procedure, accurate repositioning of jaws was confirmed and patients obtained fairly good facial contour. Conclusions: This procedure is a promising method for a widespread, predictable treatment of facial asymmetry.

치과 CAD/CAM 시스템으로 제작한 코발트-크롬 소결 금속 코핑의 변연 및 내면 적합도 평가 (Evaluation of Marginal and Internal Gap of Cobalt-Chromium Sintering Metal Coping Fabricated by Dental CAD/CAM System)

  • 김동연;신천호;정일도;김지환;김웅철
    • 치위생과학회지
    • /
    • 제15권5호
    • /
    • pp.536-541
    • /
    • 2015
  • 본 연구에서는 CAD/CAM 시스템을 이용하여 제작한 코발트-크롬 주조 금속 코핑과 코발트-크롬 소결 금속 코핑의 변연 및 내면 적합도를 비교 평가하여 다음과 같은 결론을 도출하였다. 코발트-크롬 금속 코핑의 변연 및 내면 적합도를 비교 평가는 기존의 주조방식인 CCM 그룹보다 소결과정만으로 제작한 CSM 그룹이 전반적으로 모두 우수하였다. 또한 CSM 그룹의 변연 적합도는 임상적으로 허용할 수 범위인 $120{\mu}m$ 이내 존재하였다는 결과를 통해서 그동안 매몰, 소환, 주조인 복잡한 과정을 거치면서 보철물의 오차가 발생 하였으나 소결과정만으로 공정 과정의 오차를 줄임으로써 완성도 높은 코발트-크롬 금속 코핑 제작이 가능하다고 생각된다.

지대치 형태에 따른 지르코니아 코어의 변연 적합도 (Marginal Adaptation of Zirconium Dioxide Core according to the Abutment Teeth)

  • 김기백;김석환;김재홍
    • 치위생과학회지
    • /
    • 제15권1호
    • /
    • pp.54-59
    • /
    • 2015
  • 본 연구는 시중에 널리 사용되는 치과용 지르코니아 코어를 이용하여 서로 다른 형태의 지대치를 대상으로 작업모형을 제작한 후, 치과용 스캐너를 통해 3차원 디지털 모형을 전환한 데이터를 토대로 지르코니아 코어를 제작하였으며, 각 실험군별 변연 적합도를 측정하여 비교분석하고자 하였다. 이와 같은 결과로 형태가 다른 지대치가 CAD/CAM system으로 치과 보철물 제작 시 적합도의 영향여부를 비교하였다. 제한된 조건 하에서 수행된 본 연구에서 다름과 같은 결과를 보였다. 지대치의 형태가 다른 작업모형으로 제작된 지르코니아 코어의 변연 적합도는 큰 차이가 없었다(p>0.05). 작업모형의 부위를 4등분으로 나누어 측정한 변연 적합도 또한 통계적으로 유의한 차이를 보이지 않았다. 결론적으로 3종류의 다른 지대치 모두 유사한 지르코니아 코어의 변연 적합도를 보였으며, 측정된 결과는 선행연구에 비추어 볼 때 임상적으로 허용 가능한 수치($100{\sim}120{\mu}m$)를 초과하는 실험군은 없었다. 이와 같은 결과를 토대로 다른 형태의 지대치를 사용하여 제작되었더라도 지르코니아 코어의 변연 적합도에 큰 영향을 주지 않을 것으로 생각된다.

치과용 지르코니아로 제작된 심미보철물의 임상적 예후에 관한 문헌고찰 (Review of clinical studies applying yttrium tetragonal zirconia polycrystal-based esthetic dental restoration)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권4호
    • /
    • pp.307-312
    • /
    • 2020
  • Application of ceramic materials for fabrication of dental restoration materials has been a focus of interest in the field of esthetic dentistry. The ceramic materials of choice are glass ceramics, spinel, alumina, and zirconia. The development of yttrium tetragonal zirconia polycrystal (YTZP)-based systems is a recent addition to all-ceramic systems that have high strength and are used for crowns and fixed partial dentures. Computer-aided design/computer-aided manufacturing (CAD/CAM)-produced, YTZP-based systems are popular with respect to their esthetic appeal for use in stress-bearing regions. The highly esthetic nature of zirconia and its superior physical properties and biocompatibility have enabled the development of restorative systems that meet the demands of today's patients. Many in vitro trials have been performed on the use of zirconia; however, relatively fewer long-term clinical studies have been published on this subject. The use of zirconia frameworks for long-span fixed partial dentures is currently being evaluated; in the future, more in vivo research and long-term clinical studies are required to provide scientific evidence for drawing solid guidelines. Further clinical and in vitro studies are required to obtain data regarding the long-term clinical use of zirconia-based restorations.

치과 3D 프린팅용 광중합 시간에 따른 중합도 비교 (Comparison of polymerization by time of light curing for dental 3D printing)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제44권3호
    • /
    • pp.76-80
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the depth according to curing using photocurable resin for dental three-dimensional printing. Methods: A stainless mold with a height of 4 mm was prepared. Ultraviolet (UV) polymerization resin was injected into the mold. Photocuring was then performed for 5 minutes using a photopolymerizer, and the height was measured using a digital measuring instrument (first group). Second, light polymerization was also performed outside the mold for 5 minutes, and the height was measured using a digital measuring instrument. Third, light polymerization was further performed for 5 minutes, and the height was measured using a digital measuring instrument. Statistical analysis was performed with the Kruskal-Wallis test, which is a nonparametric test (α=0.05). Results: The third group had the largest measurement length, whereas the first group had the smallest. However, the difference between groups was not statistically significant (p>0.05). The color of the first group was different from that of the second and third groups. Conclusion: All of the 4-mm-thick photocured specimens had a curing reaction, but the part that was not directly irradiated with UV did not show its original color.

Evaluation of marginal discrepancy of pressable ceramic veneer fabricated using CAD/CAM system: Additive and subtractive manufacturing

  • Kang, Seen-Young;Lee, Ha-Na;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.347-353
    • /
    • 2018
  • PURPOSE. The purpose of this study was to evaluate the marginal discrepancy of heat-pressed ceramic veneers manufactured using a CAD/CAM system. MATERIALS AND METHODS. The ceramic veneers for the abutment of a maxillary left central incisor were designed using a CAD/CAM software program. Ten veneers using a microstereolithography apparatus (AM group), ten veneers using a five-axis milling machine (SM group), and ten veneers using a traditional free-hand wax technique (TW group) were prepared according to the respective manufacturing method. The ceramic veneers were also fabricated using a heat-press technique, and a silicone replica was used to measure their marginal discrepancy. The marginal discrepancies were measured using a digital microscope (${\times}160$ magnification). The data were analyzed using a nonparametric Kruskal-Wallis H test. Finally, post-hoc comparisons were conducted using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The $mean{\pm}SD$ of the total marginal discrepancy was $99.68{\pm}28.01{\mu}m$ for the AM group, $76.60{\pm}28.76{\mu}m$ for the SM group, and $83.08{\pm}39.74{\mu}m$ for the TW group. There were significant differences in the total marginal discrepancies of the ceramic veneers (P<.05). CONCLUSION. The SM group showed a better fit than the AM and TW groups. However, all values were within the clinical tolerance. Therefore, CAD/CAM manufacturing methods can replace the traditional free-hand wax technique.

Chair-side CAD/CAM fabrication of a single-retainer resin bonded fixed dental prosthesis: a case report

  • Jurado, Carlos Alberto;Tsujimoto, Akimasa;Watanabe, Hidehiko;Villalobos-Tinoco, Jose;Garaicoa, Jorge Luis;Markham, Mark David;Barkmeier, Wayne Walter;Latta, Mark Andrew
    • Restorative Dentistry and Endodontics
    • /
    • 제45권2호
    • /
    • pp.15.1-15.7
    • /
    • 2020
  • This clinical report describes designing and fabricating a single-retainer resin-bonded fixed dental prosthesis with a chair-side computer-aided design/computer-aided manufacturing system. The whole procedure, from tooth extraction to final placement of the prosthesis, was completed in one day, and a single clinic visit. No clinical complications were found at the 2-year follow-up after placement of the restoration, and satisfactory functional and esthetic results were achieved.

전부 도재관의 변연 및 내면 간극에 대한 micro CT와 절단 시편 측정법의 비교 (Comparison of micro CT and cross-section technique for evaluation of marginal and internal fit of lithium disilicate crowns)

  • 고인석;김정미;조혜원
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.226-233
    • /
    • 2016
  • 목적: 본 연구는 수복물의 적합도를 계측하는 두 가지 측정방법을 평가하기 위해 CAD-CAM (computer aided design-computer aided manufacturing)과 열가압 소성법으로 전부 도재관을 제작하고 micro CT와 cross-section technique으로 전부 도재관의 적합도를 비교하고자 하였다. 재료 및 방법: 하악 제 1대구치 레진 치아를 전부 도재관을 위한 지대치를 형성하고 PMMA (polymethylmethacrylate) 레진 블록을 가공하여 10개의 시편을 복제하였다. 복제한 레진 다이의 인상을 채득하고 모형을 제작하여 5개는 열가압 소성법으로 IPS e.max Press (Ivoclar Vivadent, Schaan, Liechtenstein) 도재관을 제작하였다. 다른 5개의 시편은 CAD-CAM 가공법(Ceramil motion 2, Amann Girrbach, Koblach, Austria)을 이용하여 IPS e.max CAD 도재관을 제작하였다. 각 레진 다이에 전부 도재관을 인산아연 시멘트(Fleck's zinc cement, Keystone industries, Gibbstown, NJ, USA)로 손가락 압력에 의해 합착하였다. 변연 및 내면 적합도를 측정하기 위해서 합착된 시편 10개를 먼저 micro CT로 촬영하여 협-설 시상면의 영상정보를 획득하였다. 그 후 절단 시편을 만들어 주사전자현미경으로 micro CT와 동일한 지점의 간극을 측정하였다. SPSS 22.0 프로그램을 이용하여 각 측정 지점에서 제작 방식별, 측정 방식별로 Mann-Whitney 검정 방법을 통해 유의차 검증을 시행하였다. 결과: Micro CT와 주사전자현미경으로 측정한 변연 및 내면 적합도는 유사하였으며, 통계적으로 유의한 차이를 보이지 않았다. 두 가지 제작법의 도재관은 변연 및 내면 적합도에 유의한 차이가 없었다. 결론: CAD-CAM과 열가압소성으로 제작한 전부 도재관은 적합도에 차이를 보이고 있지 않으며, Micro CT와 주사전자현미경을 이용한 측정 방식 모두 임상적으로 이용 가능할 것으로 사료된다.

Evaluation of marginal discrepancy in metal frameworks fabricated by sintering-based computer-aided manufacturing methods

  • Kaleli, Necati;Ural, Cagri;Us, Yesim Olcer
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권3호
    • /
    • pp.124-130
    • /
    • 2020
  • PURPOSE. The aim of this in vitro study was to evaluate the effect of sintering procedures on marginal discrepancies of fixed partial metal frameworks fabricated using different sintering-based computer-aided design and computer/aided manufacturing (CAD/CAM) techniques. MATERIALS AND METHODS. Forty resin die models of prepared premolar and molar abutment teeth were fabricated using a three-dimensional (3D) printer and divided into four groups (n = 10) according to the fabrication method of metal frameworks used: HM (via hard milling), SM (via soft metal milling), L25 (via direct metal laser melting [DMLM] with a 25 ㎛ layer thickness), and L50 (via direct DMLM with a 50 ㎛ layer thickness). After the metal frameworks were fabricated and cemented, five vertical marginal discrepancy measurements were recorded in each site (i.e., buccal, facing the pontic, lingual, and facing away from the pontic) of both abutment teeth under a stereomicroscope (×40). Data were statistically analyzed at a significance level of 0.05. RESULTS. No statistically significant differences (P>.05) were found among the four axial sites of metal frameworks fabricated by sintering-based CAD/CAM techniques. The HM and L25 groups showed significantly (P<.001) lower marginal discrepancy values than the SM and L50 groups. CONCLUSION. Marginal discrepancy in the sites facing the pontic was not influenced by the type of sintering procedure. All fabrication methods exhibited clinically acceptable results in terms of marginal discrepancies.

하악 편위 환자에서 디지털 방식을 이용한 총의치 제작 증례 (Fabrication of complete denture using digital technology in patient with mandibular deviation: a case report)

  • 이은수;박주영;박찬;윤귀덕;임현필;박상원
    • 구강회복응용과학지
    • /
    • 제38권1호
    • /
    • pp.34-41
    • /
    • 2022
  • 최근 디지털 기술과 Computer-aided design/Computer-aided manufacturing (CAD/CAM) 작업 환경은 의치 제작에 있어 임상의의 진료 과정의 변화를 가져왔다. CAD/CAM 기술을 이용한 의치 제작 방식은 진료 및 기공 과정을 단순화하여 오류의 발생을 감소시키며, 임상적인 효율성과 편리함을 제공한다. 본 증례는 하악 편위를 가진 상·하악 완전 무치악 환자에서 광경화 SLA 기반의 3D 프린팅을 이용한 디지털 제작 방식의 양악 총의치 수복 증례이다. 구강 스캐너로 채득한 디지털 모형에서 기록상을 제작하였고 교합제에 악간관계를 기록한 후 부가 중합형 실리콘 인상재로 폐구 정밀 인상을 채득하였다. 또한 교합제를 장착하고 촬영한 안면 스캔 데이터를 추가로 획득하여 기공 작업 시 교합 평면 결정이나 인공치 배열에 참고할 수 있도록 하였다. 인상체를 3차원 스캔 후 CAD 프로그램을 통해 인공치를 배열하였고, 연마면을 형성하여 의치 디자인을 완성하였다. 시적 의치 및 최종 의치는 미국식품의약국(Food and Drug Administraion, FDA) 승인을 받은 액체 광경화성 레진을 이용하여 stereolithography (SLA) 기반 3D 프린터로 출력하였고, 최종 의치는 적절한 안정과 유지, 지지를 보였으며 기능적, 심미적으로 만족스러운 결과를 얻을 수 있었다.