• Title/Summary/Keyword: Dental abutment

Search Result 524, Processing Time 0.022 seconds

Marginal and internal fitness of three-unit zirconia cores fabricated using several CAD/CAM systems (다양한 CAD/CAM 시스템으로 제작된 3 본 고정성 가공의치 지르코니아 코어의 변연 및 내면 적합도 평가)

  • Huh, Jung-Bo;Kim, U-Sic;Kim, Ha-Young;Kim, Jong-Eun;Lee, Jeong-Yeol;Kim, Young-Su;Jeon, Young-Chan;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.236-244
    • /
    • 2011
  • Purpose: This study was aimed to compare the margin and internal fitness of 3-unit zirconia bridge cores fabricated by several CAD/CAM systems using replica technique. Materials and methods: Three unit-bridge models in which upper canine and upper second premolar were used as abutments and upper first premolar was missed, were fabricated. Fourty models were classified into 4 groups (Cerasys$^{(R)}$ (Group C), Dentaim$^{(R)}$ (Group D), KaVo Everest$^{(R)}$ (Group K), $Lava^{TM}$ (Group L)), and zirconia cores were fabricated by each company. Sixteen points were measured on each abutment by replica technique. Statistical analysis was accomplished with two way ANOVA and Dunnett T3 (${\alpha}$=.05). Results: In most systems, there was a larger gap on inter margin than outer margin. In the Group K, overall fitness was excellent, but the incisal gap was very large. In the Group C, marginal gap was significantly larger than Group K, but overall internal gap was uniform (P<.05). The axial gap was under $100\;{\mu}m$ in all system. The difference between internal and external gap was small on Group L and C. However, internal gap was significantly larger than external gap in Group D (P<.05). The fitness of canine was better than second premolar among abutments (P<.05). Conclusion: The marginal and internal gap was within the clinically allowed range in all of the three systems. There was a larger gap on second premolar than canine on internal and marginal surface. In most systems, there was a larger gap on occlusal surface than axial surface.

Survival rate of modern all-ceramic FPDs during an observation period from 2011 to 2016

  • Pott, Philipp-Cornelius;Eisenburger, Michael;Stiesch, Meike
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.18-24
    • /
    • 2018
  • PURPOSE. In literature, many studies compare survival rates of different types of FPDs. Most of them compared restorations, which originated from one university, but from different clinicians. Data about restoration survival rates by only one experienced dentist are very rare. The aim of this study was to evaluate the survival rate of all-ceramic FPDs without the blurring effects of different clinicians. MATERIALS AND METHODS. 153 veneered-zirconia FPDs were observed for follow-up. 22 patients received 131 single crowns and 22 bridges. Because of the different bridge lengths, one unit was defined as a restored or replaced tooth. In total, 201 units were included. Only the restorations performed by the same clinician and produced in the same dental laboratory from 2011 to 2016 were included. Considered factors were defined as "type of unit", "type of abutment", "intraoral region", and "vitality". Modified UHPHS criteria were used for evaluation. Statistical analysis was performed using cox-regression. RESULTS. 189 units (94.0%) showed no kind of failure. 5 chippings (2.4%) could be corrected by intraoral polishing. 4 units (1.9%) exhibited spontaneous decementation. These polishable and recementable restorations are still in clinical use. Chippings or decementations, which lead to total failure, did not occur. One unit was completely fractured (0.5 %). Biological failures (caries, periodontitis or periimplantitis) did not occur. The statistical analysis of the factors did not reveal any significant differences. CONCLUSION. Modern all-ceramic FPDs seem to be an appropriate therapy not only for single restorations but for complex occlusal rehabilitations.

AN EXPERIMENTAL STUDY OF THE EFFECT ON PULP TEMPERATURE DURING ABUTMENT PREPARATION (지대치 형성이 치수온도에 미치는 영향에 관한 실험적 연구)

  • Kim, Byong-Ki
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.14 no.1
    • /
    • pp.47-54
    • /
    • 1976
  • Pulpal temperature is changed in response for various conditions which were mechanical, thermal, chemical and biological stimuli. This study was performed to determine the pulpal temperature changes which were using air turbine with air-water coolant, water coolant, and conventional dental engine with water coolant and no coolant on 28 canine of dogs. In order to record pulpal temperature, pulp chamber was opened on the labiocervical area of canine. Thermocouple was inserted into pulp chamber and was fixed with filling material(dycal). Changes of pulpal temperature were recorded on the physiograph, which had been standardized temperature degree, through thermocouple to thermistor bridge and carrier preamplifier. The amount of experimental temperature change to that of control was interpreted in the pulpal cavity. The obtained results were as followings: 1. The mean normal temperature was 33.07 centigrade. 2. The temperature was decreased than normal pulpal temperature. It was 12.04 centigrade in reduction by air turbine with air-water coolant, 7.17 centigrade in reduction by air turbine with air coolant, 5.54 centigrade in reduction by conventional engine with water coolant, and 1.26 centigrade in reduction by conventional engine with no coolant. 3. The time for maximal temperature change was 53.3 seconds in reduction by air turbine with air-water coolant, 73.4 seconds in reduction by air turbine with air coolant, 50.9 seconds in reduction by conventional engine with water coolant, and 27.1 seconds in reduction by conventional engine with no coolant. 4.. After reduction was ceased, the recovery time to normal pulp temperature was 287.1 seconds in air turbine with air-water coolant, 189.0 seconds in air turbine with air coolant, 86.9 seconds in conventional engine with water coolant, and 52.9 seconds in conventional engine with no coolant respectively.

  • PDF

OPTICAL EFFECTS OF NONMETALLIC POST AND CORE SYSTEMS ON ALL-CERAMIC CROWNS (비금속 포스트 코어가 전부도재관에 미치는 광학적인 영향)

  • Kim Sung-Won;Cho In-Ho;Lim Ju-Hwan;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.493-506
    • /
    • 2002
  • Recently as the esthetic concerns about dental prosthesis have been increased, the nonmetallic post and core systems have been introduced clinically to improve the color and the low optical transmittance of conventional casting metal post and core systems. The purpose of this study was to compare and analyze the optical transmittance and the shade changes of all-ceramic crowns with two nonmetallic post and core systems. The experimental groups were classified as follows : Total 27 specimens(9 samples in each group) were evaluated. Group I : Natural teeth as a control group Group II : CosmoPost and $Empress^{(R)}$ core (Ivoclar-Vivadent, Liechtenstein) Group III : $LIGHT-POST^{TM}$ and $LIGHT-CORE^{TM}$ (Bisco, U.S.A.) In all group, all-ceramic crowns were fabricated with the same shade of IPS $Empress^{(R)}$ II (Ivoclar-Vivadent, Liechtenstein) after abutment preparation, and then two kinds of spectrophotometers, UV 3101 PC (Shimadzu, Japan) and CM 503i (Minolta Co. Ltd. Japan), were used to measure the optical transmittance and the color value. The following results were obtained : 1. The optical transmittance of each group without all-ceramic crowns, was siginificantly decreased in order of Group III, I and II (p<0.05). 2. The optical transmittance of each group with all-ceramic crowns cemented, were siginificantly decreased in order of Group I, II and III (p<0.05). 3. In comparison with the shade of all-ceramic crowns, there were no significant differences between groups regardless of the cementation. 4. In comparison with the shade changes in each group after the cementation of all-ceramic crowns, there were no significant differences between groups. From the above results, it is thought that the selection among materials used in this study doesn't influence greatly the esthetic restoration, because the differences of optical transmittance were so small that those were clinically insignificant.

Accuracy of a direct drill-guiding system with minimal tolerance of surgical instruments used for implant surgery: a prospective clinical study

  • Lee, Du-Hyeong;An, Seo-Young;Hong, Min-Ho;Jeon, Kyoung-Bae;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.207-213
    • /
    • 2016
  • PURPOSE. A recently introduced direct drill-guiding implant surgery system features minimal tolerance of surgical instruments in the metal sleeve by using shank-modified drills and a sleeve-incorporated stereolithographic guide template. The purpose of this study was to evaluate the accuracy of this new guided surgery system in partially edentulous patients using geometric analyses. MATERIALS AND METHODS. For the study, 21 implants were placed in 11 consecutive patients using the direct drill-guiding implant surgery system. The stereolithographic surgical guide was fabricated using cone-beam computed tomography, digital scanning, computer-aided design and computer-assisted manufacturing, and additive manufacturing processes. After surgery, the positional and angular deviations between planned and placed implants were measured at the abutment level using implant-planning software. The Kruskal-Wallis test and Mann-Whitney U test were used to compare the deviations (${\alpha}=.05$). RESULTS. The mean horizontal deviations were 0.593 mm (SD 0.238) mesiodistally and 0.691 mm (SD 0.344) buccolingually. The mean vertical deviation was 0.925 mm (SD 0.376) occlusogingivally. The vertical deviation was significantly larger than the horizontal deviation (P=.018). The mean angular deviation was 2.024 degrees (SD 0.942) mesiodistally and 2.390 degrees (SD 1.142) buccolingually. CONCLUSION. The direct drill-guiding implant surgery system demonstrates high accuracy in placing implants. Use of the drill shank as the guiding component is an effective way for reducing tolerance.

Clinical performance and failures of zirconia-based fixed partial dentures: a review literature

  • Triwatana, Premwara;Nagaviroj, Noppavan;Tulapornchai, Chantana
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.2
    • /
    • pp.76-83
    • /
    • 2012
  • PURPOSE. Zirconia has been used in clinical dentistry for approximately a decade, and there have been several reports regarding the clinical performance and survival rates of zirconia-based restorations. The aim of this article was to review the literatures published from 2000 to 2010 regarding the clinical performance and the causes of failure of zirconia fixed partial dentures (FPDs). MATERIALS AND METHODS. An electronic search of English peer-reviewed dental literatures was performed through PubMed to obtain all the clinical studies focused on the performance of the zirconia FPDs. The electronic search was supplemented by manual searching through the references of the selected articles for possible inclusion of some articles. Randomized controlled clinical trials, longitudinal prospective and retrospective cohort studies were the focuses of this review. Articles that did not focus on the restoration of teeth using zirconia-based restorations were excluded from this review. RESULTS. There have been three studies for the study of zirconia single crowns. The clinical outcome was satisfactory (acceptable) according to the CDA evaluation. There have been 14 studies for the study of zirconia FPDs. The survival rates of zirconia anterior and posterior FPDs ranged between 73.9% - 100% after 2 - 5 years. The causes of failure were veneer fracture, ceramic core fracture, abutment tooth fracture, secondary caries, and restoration dislodgment. CONCLUSION. The overall performance of zirconia FPDs was satisfactory according to either USPHS criteria or CDA evaluations. Fracture resistance of core and veneering ceramics, bonding between core and veneering materials, and marginal discrepancy of zirconia-based restorations were discussed as the causes of failure. Because of its repeated occurrence in many studies, future researches are essentially required to clarify this problem and to reduce the fracture incident.

Causes of failures of long-term used double crown denture and new rehabilitation with dental implant and tooth combined denture using remaining teeth and implants (장기간 사용한 이중관 의치의 실패원인 및 자연치와 임플란트를 이용한 이중관 의치 수복증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.384-390
    • /
    • 2018
  • Hybrid telescopic double crown have ever been good treatment option for patient with periodontally unfavorable few remaining teeth for successful prognosis. Tooth and implant combined telescopic double crown can be used for improving retention and support for denture with strategically placed implants on edentulous ridge. In this case, an 55-year-old female patient had chronic periodontitis with few remaining teeth on maxilla and fixed partial prosthodontics on mandible. Treatment of hybrid telescopic double crown with friction pin lasted 9.5 years only with natural teeth. After 9.5 years, additional implants was installed due to fracture of cast-posted abutment teeth. After implantation, tooth and implant combined double crown had fabricated. Through re-treatment, no complications of new denture has been found during 2 years follow up. This case presents fair prognosis of tooth and implant combined double crown denture in periodontally unfavorable condition.

RESTORATION OF MISSED MAXILLARY CENTRAL INCISOR USING AUTOTRANSPLANTATION OF MESIODENS : A CASE REPORT (정중과잉치의 자가이식을 통한 상실된 상악 중절치의 수복 : 증례보고)

  • Kim, Hye-Kyoung;Park, Ho-Won;Lee, Ju-Hyun;Seo, Hyun-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.3
    • /
    • pp.519-525
    • /
    • 2007
  • Supernumerary tooth is developed from overgrowth of dental laminar and is mainly observed in the maxillary anterior area, named 'mesiodens. Mesiodens cause many problems such as malposition of permanent anterior tooth, diastema, formation of cyst, and eruption to oral or nasal cavity. Extraction, therefore, is generally recommended choice of treatment. This case report describes that the patient is a 9 years and 8 months old boy, whose unilateral maxillary incisor was missing due to trauma, and he had a mesiodens. We practiced autotransplantation of the mesiodens to the missing maxillary central incisor area and then restored with prosthetics, substantially kept out alveolar bony resorption and provided esthetic appearance. Mesiodens was too small to be used as an abutment because its length is totally 14mm, so that poor prognosis was anticipated due to bad crown/root ratio. However, we observed clinically acceptable result during the observation period of 8 months after operation.

  • PDF

Sinus bone graft and simultaneous vertical ridge augmentation: case series study

  • Kang, Dong-Woo;Yun, Pil-Young;Choi, Yong-Hoon;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.36.1-36.8
    • /
    • 2019
  • Background: This study aims to examine the outcome of simultaneous maxillary sinus lifting, bone grafting, and vertical ridge augmentation through retrospective studies. Methods: From 2005 to 2010, patients with exhibited severe alveolar bone loss received simultaneous sinus lifting, bone grafting, and vertical ridge augmentations were selected. Fifteen patients who visited in Seoul National University Bundang Hospital were analyzed according to clinical records and radiography. Postoperative complications; success and survival rate of implants; complications of prosthesis; implant stability quotient (ISQ); vertical resorption of grafted bone after 1, 2, and 3 years after surgery; and final observation and marginal bone loss were evaluated. Results: The average age of the patients was 54.2 years. Among the 33 implants, six failed to survive and succeed, resulting in an 81.8% survival rate and an 81.8% success rate. Postoperative complications were characterized by eight cases of ecchymosis, four cases of exposure of the titanium mesh or membrane, three cases of periimplantitis, three cases of hematoma, two cases of sinusitis, two cases of fixture fracture, one case of bleeding, one case of numbness, one case of trismus, and one case of fixture loss. Prosthetic complications involved two instances of screw loosening, one case of abutment fracture, and one case of food impaction. Resorption of grafted bone material was 0.23 mm after 1 year, 0.47 mm after 2 years, 0.41 mm after 3 years, and 0.37 mm at the final observation. Loss of marginal bone was 0.12 mm after 1 year, and 0.20 mm at final observation. Conclusions: When sinus lifting, bone grafting, and vertical ridge augmentation were performed simultaneously, postoperative complications increased, and survival rates were lower. For positive long-term prognosis, it is recommended that a sufficient recovery period be needed before implant placement to ensure good bone formation, and implant placement be delayed.

THE STRESS ANALYSIS OF SUPPORTING TISSUE AND IMPLANT ACCORDING TO CROWN RESTORATIVE MATERIALS AND TYPE OF IMPLANT (수복재료와 임플랜트 종류에 따른 임플랜트 및 지지조직의 응력분포)

  • Choi Chang-Hwan;Oh Jong-Suk;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.1
    • /
    • pp.53-67
    • /
    • 2002
  • This study was aimed to analyze the stress distribution of implant and supporting tissue in single tooth implant restoration using Branemark $system^{(R)}$(Nobel Biocare, Gothenberg, Sweden) and Bicon system(Bicon Dental Implants, Boston, MA). Two dimensional finite element analysis model was made at mandibular first premolar area As a crown materials porcelain, ceromer, ADA type III gold alloy were used. Tests have been performed at 25Kgf vertical load on central fossa of crown portion and at 10Kgf load with $45^{\circ}$ lateral direction on cusp inclination. The displacement and stresses of implant and supporting structures were analyzed to investigate the influence of the crown material and the type of implant systems by finite element analysis. The results were obtained as follows : 1. The type of crown material influenced the stress distribution of superstructure, but did not influence that of the supporting alveolar bone. 2. The stress distribution of ceromer and type III gold alloy and porcelain is similar. 3. Stress under lateral load was about twice higher than that of vertical load in all occlusal restorative materials. 4. In Bicon system, stress concentration is similar in supporting bone area but CerOne system generated about 1.5times eater stress more in superstructure material. 5. In Branemark models, if severe occlusal overload is loaded in superstvucture. gold screw or abutment will be fractured or loosened to buffer the occlusal overload but in Bicon models such buffering effect is not expected, so in Bicon model, load can be concentrated in alveolar bone area.