Imaging findings in a case of Gorlin-Goltz syndrome: a survey using advanced modalities

  • Bronoosh, Pegah;Shakibafar, Ali Reza;Houshyar, Maneli;Nafarzade, Shima
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.171-175
    • /
    • 2011
  • Gorlin-Goltz syndrome is an infrequent multi-systemic disease which is characterized by multiple keratocysts in the jaws, calcification of falx cerebri, and basal cell carcinomas. We report a case of Gorlin-Goltz syndrome in a 23-year-old man with emphasis on image findings of keratocyctic odontogenic tumors (KCOTs) on panoramic radiograph, computed tomography, magnetic resonance (MR) imaging, and Ultrasonography (US). In this case, pericoronal lesions were mostly orthokeratinized odontogenic cyst (OOC) concerning the MR and US study, which tended to recur less. The aim of this report was to clarify the characteristic imaging features of the syndrome-related keratocysts that can be used to differentiate KCOT from OOC. Also, our findings suggested that the recurrence rate of KCOTs might be predicted based on their association to teeth.

Cone beam형 전산화단층영상의 원리 (Basic principle of cone beam computed tomography)

  • 최용석;김규태;황의환
    • Imaging Science in Dentistry
    • /
    • 제36권3호
    • /
    • pp.123-129
    • /
    • 2006
  • The use of computed tomography for dental procedures has increased recently. Cone beam computed tomography (CBCT) systems have been designed for imaging hard tissues of the dentomaxillofacial region. CBCT is capable of providing high resolution in images of high diagnostic quality. This technology allows for 3-dimensional representation of the dentomaxillofacial skeleton with minimal distortion, but at lower equipment cost, simpler image acquisition and lower patient dose. Because this technology produces images with isotropic sub-millimeter spatial resolution, it is ideally suited for dedicated dentomaxillofacial imaging. In this paper, we provide a brief overview of cone beam scanning technology and compare it with the fan beam scanning used in conventional CT and the basic principles of currently available CBCT systems.

  • PDF

레진계 임플란트용 시멘트의 방사선 불투과성에 대한 비교연구 (Comparative study on the radiopacity of different resin-based implant cements)

  • 한경환;천호영;김민수;신상완;이정열
    • 대한치과보철학회지
    • /
    • 제52권2호
    • /
    • pp.97-104
    • /
    • 2014
  • 연구 목적: 본 연구의 목적은 현재 시판되는 4종의 레진계 임플란트 전용 임시 시멘트를 디지털 방사선 사진을 분석하여 방사선 불투과성을 비교 평가 하는 것이다. 연구 재료 및 방법: 주문 제작한 분할형 금속몰드에 4종의 레진계 임플란트 시멘트(Estemp $Implant^{TM}$ (Spident, Incheon, Korea), $Premier^{(R)}$Implant (Premier, Pennsylvania, USA), $Cem-Implant^{TM}$ (B.J.M lab, Or-yehuda, Israel), $InterCem^{TM}$ (SCI-PHARM, California, USA))와 대조군인 Elite Cement$100^{TM}$ (GC, Tokyo, Japan)를 각각의 제조사의 지시에 따라 혼합하여 경화시킨다. 시멘트당 두께에 따라 각 10개씩 총 150개의 시편을 제작하고 각 시편을 순수(99%이상) aluminum으로 제작한 step wedge와 나란히 위치시켜 Intraoral X-ray unit (Esx, Vatech, Korea)와 디지털 X-ray sensor (EzSensor, Vatec. Korea)를 사용하여 촬영하였다. 디지털 방사선 이미지를 Image J 1.47m (Wayne Rasband, National Institutes of Health, USA)과 Color inspector 3D Ver 2.0 (Interaktive Visualisierung von Farbr$\ddot{a}$umen, Berlin, Germany)의 프로그램을 이용하여 aluminum wedge equivalent thickness (mm Al)를 평가하였다. 결과: 본 연구에서 사용된 5종의 시멘트 중 방사선 불투과성은 Elite Cement$100^{TM}$이 모든 두께에서 가장 높았으며 레진계 임플란트용 시멘트중에서 $InterCem^{TM}$이 가장 높았고, $Premier^{(R)}$ Implant $Cement^{TM}$, $Cem-Implant^{TM}$, Estemp $Implant^{TM}$순으로 나타났다. 레진계 임플란트용 시멘트 중 $InterCem^{TM}$은 모든 두께에서 ISO Standard No. 4049에 맞는 방사선 불투과성을 보였고, $Cem-Implant^{TM}$는 0.5 mm 두께에서만 ISO Standard No. 4049에 적합한 방사선 불투과도를 나타냈다. 결론:이번 연구에 사용된 레진계 임플란트 시멘트중 방사선 불투과도는 전반적으로 높지 않았고, $InterCem^{TM}$ 만이 연구조건 및 기준에 만족하는 방사선 불투과도를 보였다.

The location of midfacial landmarks according to the method of establishing the midsagittal reference plane in three-dimensional computed tomography analysis of facial asymmetry

  • Kim, Min Sun;Lee, Eun Joo;Song, In Ja;Lee, Jae-Seo;Kang, Byung-Cheol;Yoon, Suk-Ja
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.227-232
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the influence of methods of establishing the midsagittal reference plane (MRP) on the locations of midfacial landmarks in the three-dimensional computed tomography (CT) analysis of facial asymmetry. Materials and Methods: A total of 24 patients (12 male and 12 female; mean age, 22.5 years; age range, 18.2-29.7 years) with facial asymmetry were included in this study. The MRP was established using two different methods on each patient's CT image. The x-coordinates of four midfacial landmarks (the menton, nasion, upper incisor, and lower incisor) were obtained by measuring the distance and direction of the landmarks from the MRP, and the two methods were compared statistically. The direction of deviation and the severity of asymmetry found using each method were also compared. Results: The x-coordinates of the four anatomic landmarks all showed a statistically significant difference between the two methods of establishing the MRP. For the nasion and lower incisor, six patients (25.0%) showed a change in the direction of deviation. The severity of asymmetry also changed in 16 patients (66.7%). Conclusion: The results of this study suggest that the locations of midfacial landmarks change significantly according to the method used to establish the MRP.

Micro-computed tomographic evaluation of single-cone obturation with three sealers

  • Sahar Zare;Ivy Shen;Qiang Zhu;Chul Ahn;Carolyn Primus;Takashi Komabayashi
    • Restorative Dentistry and Endodontics
    • /
    • 제46권2호
    • /
    • pp.25.1-25.12
    • /
    • 2021
  • Objectives: This study used micro-computed tomography (µCT) to compare voids and interfaces in single-cone obturation among AH Plus, EndoSequence BC, and prototype surface pre-reacted glass ionomer (S-PRG) sealers and to determine the percentage of sealer contact at the dentin and gutta-percha (GP) interfaces. Materials and Methods: Fifteen single-rooted human teeth were shaped using ProTaper NEXT size X5 rotary files using 2.5% NaOCl irrigation. Roots were obturated with a single-cone ProTaper NEXT GP point X5 with AH Plus, EndoSequence BC, or prototype S-PRG sealer (n = 5/group). Results: The volumes of GP, sealer, and voids were measured in the region of 0-2, 2-4, 4-6, and 6-8 mm from the apex, using image analysis of sagittal µCT scans. GP volume percentages were: AH Plus (75.5%), EndoSequence BC (87.3%), and prototype S-PRG (94.4%). Sealer volume percentages were less: AH Plus (14.3%), EndoSequence BC (6.8%), and prototype S-PRG (4.6%). Void percentages were AH Plus (10.1%), EndoSequence BC (5.9%), and prototype S-PRG (1.0%). Dentin-sealer contact ratios of AH Plus, EndoSequence BC, and prototype S-PRG groups were 82.4% ± 6.8%, 71.6% ± 25.3%, and 70.2% ± 9.4%, respectively. GP-sealer contact ratios of AH Plus, EndoSequence BC, and prototype S-PRG groups were 65.6% ± 29.1%, 80.7% ± 25.8%, and 87.0% ± 8.6%, respectively. Conclusions: Prototype S-PRG sealer created a low-void obturation, similar to EndoSequence BC sealer with similar dentin-sealer contact (> 70%) and GP-sealer contact (> 80%). Prototype S-PRG sealer presented comparable filling quality to EndoSequence BC sealer.

치과 방사선 발생기의 성능평가에 관한 연구 (Study on Performance Evaluation of Dental X-ray Equipment)

  • 정재은;정재호;강희두;이종웅;나극환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

디지털공제방사선촬영술을 이용한 치근단 흡수의 평가 (Assessment of apical root resorption using digital subtraction radiography)

  • 허민석;이삼선;이경희;최항문;최순철;박태원
    • Imaging Science in Dentistry
    • /
    • 제31권1호
    • /
    • pp.51-55
    • /
    • 2001
  • Purpose : This study was performed to compare the diagnostic ability of conventional intraoral radiographs with that of digital subtraction image and to assess the quantifying ability of digital subtraction image for simulated apical root resorption Materials and Methods : Conventional intraoral radiographs and digital images of ten sound maxillary central incisors and those with simulated apical root resorption were taken with varying horizontal and vertical angulations of the x-ray beam. The diagnostic accuracy to detect the lesion was evaluated on conventional intraoral radiographs and digital subtraction images by ROC analysis. The amount of simulated apical root resorption was also estimated on the reconstruction images by Emago/sup (R)/ and compared with actual amount of tooth loss using paired t-test. Results: The diagnostic accuracy of conventional intraoral radiographs to detect the apical root resorption was low (ROC area = 0.6446), and the sensitivity and the specificity of digital subtraction images were 100%, respectively. The calculated amounts of apical root resorption showed no statistically significant difference with the actual amounts of the lesion (p>0.05). Conclusion: Digital subtraction radiography is powerful tool to detect the small apical root resorption, and quantitative analysis of small amounts of the lesion can be evaluated by digital subtraction radiography.

  • PDF

Three-dimensional imaging modalities in endodontics

  • Mao, Teresa;Neelakantan, Prasanna
    • Imaging Science in Dentistry
    • /
    • 제44권3호
    • /
    • pp.177-183
    • /
    • 2014
  • Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of periradicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

단층촬영상에서 계획된 임플랜트 매식 각도 및 위치에 대한 스텐트 핀의 상대적 각도 및 위치에 대한 평가 (The angulation and the position change of the planned implant after tomographic imaging)

  • 강병철
    • Imaging Science in Dentistry
    • /
    • 제37권3호
    • /
    • pp.127-131
    • /
    • 2007
  • Purpose: To measure the differences of the splint pin angulation and the position of the planned implant site after conventional tomographic analysis. Materials and Methods: The angulation and the location of the metal splint pin retained in acrylic stent were compared with the corrected angulation and the location of the implant fixture on the 331 tomographic images. Results: The stent pins were located buccal in 40%, lingual in 10% to the corrected implant site after analysis of the conventional tomographic image. The angle and the location of the maxillary splint pin were mainly directed buccal on incisor and canine regions. The angle and the location of the splint pins in premolar and molar regions needed less corrections in both maxilla and mandible. Conclusions: This study demonstrated that the use of tomographs was essential for successful dental implant planning.

  • PDF

노출 시간과 영상 해상도가 프랙탈 차원값에 미치는 영향 (Effect of exposure time and image resolution on fractal dimension)

  • 안병모;허민석;이승표;이삼선;최순철;박태원;김종대
    • Imaging Science in Dentistry
    • /
    • 제32권2호
    • /
    • pp.75-79
    • /
    • 2002
  • Purpose : To evaluate the effect of exposure time and image resolution on fractal dimension calculations for determining the optimal range of these two variances. Materials and Methods : Thirty-one radiographs of the mandibular angle area of sixteen human dry mandibles were taken at different exposure times (0.01, 0.08, 0.16, 0.25, 0.40, 0.64, and 0.80 s). Each radiograph was digitized at 1200 dpi, 8 bit, 256 gray level using a film scanner. We selected an Region of Interest (ROI) that corresponded to the same region as in each radiograph, but the resolution of ROI was degraded to 1000, 800, 600, 500, 400, 300, 200, and 100 dpi. The fractal dimension was calculated by using the tile-counting method for each image, and the calculated values were then compared statistically. Results: As the exposure time and the image resolution increased, the mean value of the fractal dimension decreased, except the case where exposure time was set at 0.01 seconds (α = 0.05). The exposure time and image resolution affected the fractal dimension by interaction (p<0.001). When the exposure time was set to either 0.64 seconds or 0.80 seconds, the resulting fractal dimensions were lower, irrespective of image resolution, than at shorter exposure times (α = 0.05). The optimal range for exposure time and resolution was determined to be 0.08- 0.40 seconds and from 400-1000 dpi, respectively. Conclusion : Adequate exposure time and image resolution is essential for acquiring the fractal dimension using tile-counting method for evaluation of the mandible.

  • PDF