• Title/Summary/Keyword: Dental X-ray image

Search Result 95, Processing Time 0.027 seconds

THE STUDY OF TECHNICAL FAILURE OF INTRAORAL ROENTGENOGRAPHY (국내 X-선 촬영술에 있어서 실패의 원인분석에 관한 연구)

  • Kang Yong Sang
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.7 no.1
    • /
    • pp.27-30
    • /
    • 1977
  • To insure accuracy in dental roentgenographs, it is important that the patient's head position and angulation of the x-ray tube. In 1907 Cieszynski applied the rule of isometry to dental radiography and established that in the production of an accurate image of a tooth, the central ray must be porjected perpendicularly to a plane bisecting angle formed by the longitudinal axis of the tooth and the film plane. Proper exposure of the film is a part of the production of a good dental radiograph, and correct processing also makes an essential contribution to the quality of the radiograph. The author analysed the failure of exposure and processing results, and recommended followings. 1. The patient head must be positioned that occlusal plane are parallel with the horizontal floor. 2. Central ray must be projected to the objective tooth and supporting structure and projected as perpendicularly to tooth axis and film surface as possible. 3. In processing, the temperature of the solution and the processing time must be correct.

  • PDF

Physical principles of digital radiographic imaging system (디지털 방사선영상 시스템의 기본적 원리)

  • Choi, Jin-Woo;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

Digital X-Ray Technology and Applications (디지털 엑스선 기술과 응용)

  • Jeong, J.W.;Kang, J.T.;Kim, J.W.;Park, S.;Lee, M.L.;Song, Y.H.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.5
    • /
    • pp.1-13
    • /
    • 2019
  • In modern times, X-ray imaging has become a necessary tool for early diagnosis, quality control, nondestructive testing, and security screening. X-ray imaging equipment generally comprises an X-ray generator and an image sensor. Most commercially available X-ray generators employ filament-thermionic electron-based X-ray tubes, thus demonstrating typical analog behavior, such as slow response and large stray X-rays. Furthermore, digital X-ray sources, which have been studied extensively using field electron emitters manufactured from nanometer-scale materials, provide fast and accurately controlled ultra-shot X-rays. This could usher in a new era of X-ray imaging in medical diagnosis and nondestructive inspections. Specifically, digital X-ray sources, with reduced X-ray dose, can significantly improve the temporal and spatial resolution of fluoroscopy and computed tomography. Recently, digital X-ray tube technologies based on carbon nanotubes, developed by Electronics and Telecommunications Research Institute, have been transferred to several companies and commercialized for dental imaging for the first time.

Theory of X-ray microcomputed tomography in dental research: application for the caries research (치과 분야 연구에서 미세전산화 단층촬영술의 이론: 치아우식증에 대한 적용)

  • Park, Young-Seok;Bae, Kwang-Hak;Chang, Ju-Hea;Shon, Won-Jun
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.98-107
    • /
    • 2011
  • Caries remains prevalent throughout modern society and is the main disease in the field of dentistry. Although studies of this disease have used diverse methodology, recently, X-ray microtomography has gained popularity as a non-destructive, 3-dimensional (3D) analytical technique, and has several advantages over the conventional methods. According to X-ray source, it is classified as monochromatic or polychromatic with the latter being more widely used due to the high cost of the monochromatic source despite some advantages. The determination of mineral density profiles based on changes in X-ray attenuation is the principle of this method and calibration and image processing procedures are needed for the better image and reproducible measurements. Using this tool, 3D reconstruction is also possible and it enables to visualize the internal structures of dental caries. With the advances in the computer technology, more diverse applications are being studied, such automated caries assessment algorithms.

The effects of voltage of x-ray tube on fractal dimension and anisotropy of diagnostic image

  • Baik, Jee-Seon;Lee, Sam-Sun;Park, Kwan-Soo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.211-215
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the effect of the kV on fractal dimension of trabecular bone in digital radiographs. Materials and Methods: 16 bone cores were obtained from patients who had taken partial resection of tibia due to accidents. Each bone core along with an aluminum step wedge was radiographed with an occlusal film at 0.08 sec and with the constant film-focus distance (32 cm). All radiographs were acquired at 60, 75, and 90 kV. A rectangular ROI was drawn at medial part, distal part, and the bone defect area of each bone core image according to each kV. The directional fractal dimension was measured using Fourier Transform spectrum, and the anisotropy was obtained using directional fractal dimension. The values were compared by the repeated measures ANOVA. Results : The fractal dimensions increased along with kV increase (p < 0.05). The anisotropy measurements did not show statistically significant difference according to kV change. The fractal dimensions of the bone defect areas of the bone cores have low values contrast to the non-defect areas of the bone cores. The anisotropy measurements of the bone defect areas were lower than those of the non-defect areas of the bone cores, but not statistically significant. Conclusion: Fractal analysis can notice a difference of a change of voltage of x-ray tube and bone defect or not. And anisotropy of a trabecular bone is coherent even with change of the voltage of x-ray tube or defecting off a part of bone.

  • PDF

A STUDY ON THE SCATTER RADIATION AFFECTING THE DENTAL X-RAY FILM (산란 방사선이 치과용 방사선 필름에 미치는 영향에 관한 연구)

  • Park Eung Chun;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.87-94
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of scatter radiation to dental x-ray film with long time-exposure in the different structures of the tooth, by using pinhole camera. For this study, pinhole camera, skull with tooth, and pocket dosimeter were used. The radiation with 70 and 90kVp and exposure time (minimum: 2.5 min., maximum 10 hrs.) was projected to the film in the pinhole camera. And density of the obtained x-ray film was measured with densitometer. In the intra-oral film taking, the amount of exposure of the scatter radiation affecting the thyroid gland area was measured with the dosimeter at the thyroid gland. The density of radiographs was compared in radiation projected with or without the metal cone of dental machine. The effect of the back scatter radiation to the film was also evaluated when the lead foil was removed. The obtained results were as follows: 1. A pinhole camera was a valuable device for locating the source of x-ray. 2. The scatter radiation affected the dental x-ray film when the radiation source was exposed. more than 5 hours'. In that case, the density of the scatter radiation could be observed visually. 3. The scatter radiation caused by short exposure of dental radiation didn't affect the diagnostic quality of the dental x-ray film. 4. The differences of densities between the tooth and the soft tissue according to exposure time showed 0.16 in 5 hours' exposure & 0.17 in 10 hours' exposure at 70 kVp & 0.12 in 5 hours' exposure & 0.13 in 10 hours' exposure at the 90kVp. 5. The differences of densities between the tooth and the soft tissue according to kVp showed no difference between 5 hours' exposure of tooth at 70 kVp and soft tissue at 90 kVp, but showed 0.05 high density in tooth when 10 hours' exposure at 90 kVp. 6. No difference of density was on radiographs taken with or without dental machine cone. 7. Back scatter radiation was recorded image of radiographs for only 3 min. 8. The amounts of the scatter radiation exposed to the thyroid gland in intraoral film taking were 1.12 mr in upper anterior, 0.55 mr in upper posterior, 2.75 mr in lower anterior, and 1.92 mr in lower posterior teeth.

  • PDF

Preliminary Test of Google Vertex Artificial Intelligence in Root Dental X-ray Imaging Diagnosis (구글 버텍스 AI을 이용한 치과 X선 영상진단 유용성 평가)

  • Hyun-Ja Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.267-273
    • /
    • 2024
  • Using a cloud-based vertex AI platform that can develop an artificial intelligence learning model without coding, this study easily developed an artificial intelligence learning model by the non-professional general public and confirmed its clinical applicability. Nine dental diseases and 2,999 root disease X-ray images released on the Kaggle site were used for the learning data, and learning, verification, and test data images were randomly classified. Image classification and multi-label learning were performed through hyper-parameter tuning work using a learning pipeline in vertex AI's basic learning model workflow. As a result of performing AutoML(Automated Machine Learning), AUC(Area Under Curve) was found to be 0.967, precision was 95.6%, and reproduction rate was 95.2%. It was confirmed that the learned artificial intelligence model was sufficient for clinical diagnosis.

A Study of Computer-aided Detection System for Dental Cavity on Digital X-ray Image (디지털 X선 영상을 이용한 치아 와동 컴퓨터 보조 검출 시스템 연구)

  • Heo, Chang-hoe;Kim, Min-jeong;Cho, Hyun-chong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1424-1429
    • /
    • 2016
  • Segmentation is one of the first steps in most diagnosis systems for characterization of dental caries in an early stage. The purpose of automatic dental cavity detection system is helping dentist to make more precise diagnosis. We proposed the semi-automatic method for the segmentation of dental caries on digital x-ray images. Based on a manually and roughly selected ROI (Region of Interest), it calculated the contour for the dental cavity. A snake algorithm which is one of active contour models repetitively refined the initial contour and self-examination and correction on the segmentation result. Seven phantom tooth from incisor to molar were made for the evaluation of the developed algorithm. They contained a different form of cavities and each phantom tooth has two dental cavities. From 14 dental cavities, twelve cavities were accurately detected including small cavities. And two cavities were segmented partly. It demonstrates the practical feasibility of the dental lesion detection using Computer-aided Detection (CADe).

Periimplantitis Detection in Dental X-Ray Image by Structure Analysis (구조적 분석을 통한 임플란트 주위염 분리에 관한 연구)

  • 장창일;안용학;채옥삼
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2001.04b
    • /
    • pp.514-516
    • /
    • 2001
  • 본 논문은 시차를 두고 촬영된 두 장의 치과용 디지털 X-Ray 영상으로부터 임플란트 시술환자에서 자주 발생하는 임플란트 주위염을 검출하는 자동화된 시계열 분석 방안을 제안한다. 분석자에 따라서 결과의 차이를 보이는 수동적인 시계열분석방법의 문제점을 극복하고 보다 객관적이고 정략적인 결과를 얻는 방안을 제시한다. 보다 신속하고 정확한 검출을 위해서 본 연구에서는 치아의 구조 분석을 통해서 환부 탐색 영역을 줄이고 작은 변화도 민감하게 검출할 수 있는 환부영역을 분리할 수 있는 방안을 제안한다. 또한 분리된 환부의 특성을 수치적으로 표현할 수 있는 방안도 함께 제시된다.

  • PDF