• Title/Summary/Keyword: Dental Titanium

Search Result 538, Processing Time 0.024 seconds

Prevention and Solution of the Fracture of Nickel-Titanium Endodontic Instruments (니켈티타늄 전동파일 파절의 예방 및 처치)

  • Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.54 no.8
    • /
    • pp.640-650
    • /
    • 2016
  • Nickel-Titanium (NiTi) rotary instruments have brought a big step toward "efficient" practice of endodontic procedure. The rotary files help clinicians to reduce their working time and also increase the clinical success rate with minimal procedural errors. However, NiTi instruments still have a few drawbacks including unpredictable fatigue fracture. Clinicians may reduce the potential risk of instruments fracture by following some clinical guidelines for rotary instruments. In some clinical cases of instruments fracture, we may try to remove the instruments' fragments or bypass the fragment to reach the apical canal. In some limited cases, the fractured instruments' fragments would not jeopardize the clinical prognosis of root canal treatment. Nevertheless, it is impossible to be overemphasized that the prevention of file fracture is much easier than the removal of fracture fragment. Clinicians need to understand the fracture mechanisms and, in clinic, need to discard the used instruments timely.

  • PDF

Wear Properties of Cast Titanium Alloys for Dental Use (치과용 Titanium 주조합금의 마멸특성)

  • Choi, Seok-Kyu;Kim, Hyung-Il;Park, Ik-Min
    • Journal of Korea Foundry Society
    • /
    • v.11 no.6
    • /
    • pp.482-490
    • /
    • 1991
  • This study presents the wear characteristics of Ti alloys (Pure Ti, Ti-6Al-4V, Ti-5Al-2.5Sn) fabricated by centrifugal precision casting in an Ohara dental titanium casting machine. It was found that the hardness of the surface region is higher than that of the interior region. It is considered that the oxygen adsorption in the surface region during casting, leads to the interstitial solid solution hardening. Wear resistance incerases in the order of pure Ti, Ti-6Al-4V, Ti-5Al-2.5Sn alloys. The interior hardness value increases in the same order. The specific wear rate increases with applied load and increases monotonously with sliding speed. The Fe transfer from the counterpart material was observed on the worn surface of the Ti-5Al-2.5Sn alloy. Oxidative wear occurs at low sliding speeds and mechanical fracture wear occurs at high sliding speeds.

  • PDF

Capillary Electrophoresis Detection of Hydrogen Peroxide by Using Titanium Ion and 4-(2-thiazolylazo)resorcinol

  • Vu Phuong, Dong;Yoo, Hoon
    • International Journal of Oral Biology
    • /
    • v.42 no.4
    • /
    • pp.197-201
    • /
    • 2017
  • A novel method for the detection of hydrogen peroxide in aqueous solution was developed via reaction between $H_2O_2$, trivalent titanium ion ($Ti^{3+}$) and 4-(2-thiazolylazo) resorcinol (TAR), resulting in a ternary complex with a maximum UV absorbance at 530 nm. The CE detection of $H_2O_2$ was fast, sensitive and cost-effective without pretreatment procedures. $H_2O_2$ was detected within 15 min at 1 to $100{\mu}M$ range with the lowest detection limit at $1.0{\mu}M$. Under the optimized CE conditions, the concentration of $H_2O_2$ in coffee or tea extract was quantitatively determined. Our results show that CE detection of the ternary complex of $H_2O_2-Ti^{3+}$-TAR has potential applications for the detection of $H_2O_2$ in aqueous sources.

A review regarding on design of engine-driven nickel-titanium file (임상가를 위한 특집 2 - 엔진구동형 니켈-티타늄 파일의 디자인에 관한 고찰)

  • Hwang, Ho-Keel
    • The Journal of the Korean dental association
    • /
    • v.51 no.10
    • /
    • pp.551-555
    • /
    • 2013
  • The purpose of this study was to give a guideline for selecting the nickel-titanium (NiTi) file by review from many studies. Since the early 1990s, several instrument systems manufactured from NiTi have been introduced into endodontic practice. The specific design characteristics vary, such as tip shape and size, cross sectional view, helix angle, and pitch space. Some of the early systems have been removed from the market or play only minor roles; others are still widely used. New designs continually are produced, but the extent to which clinical outcomes will depend on design characteristics is difficult to forecast. In this study, I have reviewed the different design characteristics in respect of the safety and efficiency. With the review from many studies, I concluded that the clinicians must be understand the specific design characteristics for selecting the ideal NiTi rotary instruments.

Fracture of Nickel-Titanium Rotary Instruments and its Clinical Prognosis (임상가를 위한 특집 1 - 니켈티타늄 전동파일의 파절과 임상적 예후)

  • Kim, Hyeon-Cheol
    • The Journal of the Korean dental association
    • /
    • v.52 no.2
    • /
    • pp.60-68
    • /
    • 2014
  • Nickel-Titanium(NiTi) rotary instruments have brought a big step toward "efficient" practice of endodontic procedure. The rotary files help clinicians to reduce their working time and also increase the clinical success rate with minimal procedural errors by stainless steel instruments. In spite of these advantages, NiTi instruments still have a few drawbacks including unpredictable fatigue fracture. Clinicians may reduce the potential risk of instruments fracture by following some clinical guidelines for rotary instruments. In some clinical cases of instruments fracture, we may try to remove the instruments' fragments or bypass the fragment to reach the apical canal. In some limited cases, the fractured instruments' fragments would not jeopardize the clinical prognosis of root canal treatment. However, it is impossible to be overemphasized that the fragment removal is more difficult than the prevention of fracture. Clinicians need to understand the fracture mechanisms and, in clinic, need to discard the used instruments timely.

Effects of acid-treatment conditions on the surface properties of the RBM treated titanium implants (산-처리 조건이 RBM처리한 티타늄 임플란트의 표면 특성에 주는 영향)

  • Lee, Han-Ah;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.45 no.4
    • /
    • pp.257-274
    • /
    • 2018
  • The purpose of this study was to evaluate the effect of acid-treatment conditions on the surface properties of the RBM (Resorbable Blast Media) treated titanium. Disk typed cp-titanium specimens were prepared and RBM treatments was performed with calcium phosphate ceramic powder. Acid solution was mixed using HCl, $H_2SO_4$ and deionized water with 4 different volume fraction. The RBM treated titanium was acid treated with different acid solutions at 3 different temperatures and for 3 different periods. After acid-treatments, samples were cleaned with 1 % Solujet solution for 30 min and deionized water for 30 min using ultrasonic cleanser, then dried in the electrical oven ($37^{\circ}C$). Weight of samples before and after acid-treatment were measured using electric balance. Surface roughness was estimated using a confocal laser scanning microscopy, crystal phase in the surface of sample was analyzed using X-ray diffractometer. Surface morphology and components were evaluated using Scanning Electron Microscope (SEM) with Energy Dispersive X-ray spectroscopy (EDX) and X-ray Photoemission Spectroscopy (XPS). Values of the weight changes and surface roughness were statistically analyzed using Tukey-multiple comparison test (p=0.05). Weight change after acid treatments were significantly increased with increasing the concentration of $H_2SO_4$ and temperature of acid-solution. Acid-treatment conditions (concentration of $H_2SO_4$, temperature and time) did not produce consistent effects on the surface roughness, it showed the scattered results. From XRD analysis, formation of titanium hydrides in the titanium surface were observed in all specimens treated with acid-solutions. From XPS analysis, thin titanium oxide layer in the acid-treated specimens could be evaluated. Acid solution with $90^{\circ}C$ showed the strong effect on the titanium surface, it should be treated with caution to avoid the over-etching process.