Browse > Article

Fracture of Nickel-Titanium Rotary Instruments and its Clinical Prognosis  

Kim, Hyeon-Cheol (Department of Conservative Dentistry, School of Dentistry, Pusan National University)
Publication Information
The Journal of the Korean dental association / v.52, no.2, 2014 , pp. 60-68 More about this Journal
Abstract
Nickel-Titanium(NiTi) rotary instruments have brought a big step toward "efficient" practice of endodontic procedure. The rotary files help clinicians to reduce their working time and also increase the clinical success rate with minimal procedural errors by stainless steel instruments. In spite of these advantages, NiTi instruments still have a few drawbacks including unpredictable fatigue fracture. Clinicians may reduce the potential risk of instruments fracture by following some clinical guidelines for rotary instruments. In some clinical cases of instruments fracture, we may try to remove the instruments' fragments or bypass the fragment to reach the apical canal. In some limited cases, the fractured instruments' fragments would not jeopardize the clinical prognosis of root canal treatment. However, it is impossible to be overemphasized that the fragment removal is more difficult than the prevention of fracture. Clinicians need to understand the fracture mechanisms and, in clinic, need to discard the used instruments timely.
Keywords
Fracture; Prognosis; Root canal treatment; Nickel-Titanium instruments;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Bössler C, Peters OA, Zehnder M. Impact of lubricant parameter on rotary instrument torque and force. J Endod 2007;33:280-3.   DOI
2 Spili P, Parashos P, Messer HH. The impact of instrument fracture on outcome of endodontic treatment. J Endod 2005;31:845-50.   DOI
3 Berutti E, Paolino DS, Chiandussi G, Alovisi M, Cantatore G, Castellucci A, Pasqualini D. Root canal anatomy preservation of WaveOne reciprocating files with or without glide path. J Endod 2012;38:101-4.
4 Bürklein S, Sch?fer E. Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems. J Endod 2012;38:850-2.   DOI   ScienceOn
5 Glosson CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni?Ti hand, Ni?Ti engine-driven, and K-Flex endodontic instruments. J Endod 1995;21:146-51.   DOI   ScienceOn
6 Parashos P, Messer HH. Rotary NiTi instrument fracture and its consequences. J Endod 2006;32:1031-43.   DOI   ScienceOn
7 Tzanetakis GN, Kontakiotis EG, Maurikou DV, Marzelou MP. Prevalence and management of instrument fracture in the postgraduate endodontic program at the Dental School of Athens: a fiveyear retrospective clinical study. J Endod 2008;34:675-8.   DOI
8 Bahia MGA, Martins RC, Gonzalez BM, Buono VTL. Physical and mechanical characterization and the influence of cyclic loading on the behaviour of nickel-titanium wires employed in the manufacture of rotary endodontic instruments. Int Endod J 2005;38:795-801.   DOI   ScienceOn
9 Cheung GS, Oh SH, Ha JH, Kim SK, Park SH, Kim HC. Effect of torsional loading of nickel-titanium instruments on cyclic fatigue resistance. J Endod 2013;39:1593-7   DOI
10 Kim HC, Cheung GSP, Lee CJ, Kim BM, Park JK, Kang SI. Comparison of Forces Generated During Root Canal Shaping and Residual Stresses of Three Nickel?Titanium Rotary Files by Using a Three-Dimensional Finite-element Analysis. J Endod 2008;34:743-7.   DOI   ScienceOn
11 Kim HC, Kim HJ, Lee CJ, Kim BM, Park JK, Versluis A. Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals. Int Endod J 2009;42:593-602.   DOI
12 Kim HC, Lee MH, Yum J, Versluis A, Lee CJ, Kim BM. Potential Relationship between Design of Nickel-Titanium Rotary Instruments and Vertical Root Fracture. J Endod 2010;36:1195-9.   DOI
13 Kim JY, Cheung GS, Park SH, Ko DC, Kim JW, Kim HC. Effect from cyclic fatigue of nickeltitanium rotary files on torsional resistance. J Endod 2012;38:527-30.   DOI
14 Peters OA. Current challenges and concepts in the preparation of root canal systems: a review. J Endod 2004;30:559-67.   DOI   ScienceOn
15 Kim TO, Cheung GSP, Lee JM, Kim BM, Hur B, Kim HC. Stress distribution of three NiTi rotary files under bending and torsional conditions using a mathematic analysis. Int Endod J 2009;42:14-21.   DOI   ScienceOn
16 Park SY, Cheung GS, Yum J, Hur B, Park JK, Kim HC. Dynamic Torsional Resistance of Nickel- Titanium Rotary Instruments. J Endod 2010;36:1200-4.   DOI   ScienceOn
17 Walia HM, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endod 1988;14:346-51.   DOI   ScienceOn
18 Thompson SA. An overview of nickel?titanium alloys used in dentistry. Int Endod J 2000;33:297-310.   DOI   ScienceOn