• Title/Summary/Keyword: Dental Laboratory Technology

Search Result 686, Processing Time 0.031 seconds

Photopolymerization Efficiency of Dental Resin Composites with Novel Liquid Amine Photoinitiators (액상 amine 광개시제에 따른 치과용 복합수지의 중합효율)

  • Sun, Gum-Ju
    • Journal of dental hygiene science
    • /
    • v.8 no.3
    • /
    • pp.109-115
    • /
    • 2008
  • Two t-amines, N,N-dimethylaniline (MA), N,N-dimethyl-p-toluidine (MPT), were investigated as new visible light amine initiators for a dental resin composite of UDMA in order to improve photopolymerization effect. Three t-amines mixed with three photosensitizers, camphorquinone(CQ), 1-phenyl-1,2-propane dione(PD) and diacetyl (DA), respectively. And then this mixtures are added to resin monomer, UDMA. Photopolymerization efficiency of UDMA was studied through the use of FT-IR absorption spectroscopy. The photopolymerization effect of amine initiators were compared with that of 4-(dimethylamino)ethyl methacrylate (AEM), the most widely used photoinitiator. The photopolymerization efficiency of UDMA containing the amine initiator increased with irradiation time. The relative polymerization efficiency containing the CQ photosensitizer increase was in the order: AEM < MPT < MA. And the relative polymerization efficiency containing the PD photosensitizer increase was in the order: MPT < AEM < MA. This result shows that MA is most efficient amine initiator with CQ and PD.

  • PDF

A manufacturing process and characteristic observation of alloy blocks for dental CAD/CAM system (치과 CAD/CAM 가공용 합금블럭 제조 및 특성 관찰)

  • Kim, Chi-young
    • Journal of Technologic Dentistry
    • /
    • v.40 no.3
    • /
    • pp.125-131
    • /
    • 2018
  • Purpose: Automatic dental prosthesis manufacturing process was accelerated by the spread of dental CAD / CAM system. The CAD / CAM system with milling alloys were needed supplement. So, sintered alloy blocks were introduced. In this study, we want to study sintered alloy block. And to evaluate the alloy block manufacture and alloy properties. Methods: The alloy powders were prepared by high pressure water dispersion method. The sintered alloy blocks were prepared by low temperature pressing method. Their components observation were EDX, and the alloy structure was observed by XRD. Results: Co-Cr alloy powders were observed to have a circle shape with an average diameter of about $100{\mu}m$ and a Ni-Cr alloy powder had a circle shape with an average diameter of about $50{\mu}m$. The Co-Cr alloy block is composed of Co (34.62 wt%), Cr (17.33 wt%), Mo (2.98 wt%), Si (0.36 wt%) and C (44.17 wt%). The Ni-Cr alloy powder was composed of Ni (40.29 wt%), Cr (19.37 wt%), Mo (3.53 wt%), Si (0.52 wt%) and C (33.18 wt%). The peak of the Co and CoCr peaks were observed in the CoCr alloy body by the means of XRD study. Cr2Ni3 of the peak was observed in the Ni-Cr alloy material. Conclusion : As a result, the following conclusions were obtained. 1. Prepared by high-pressure water-law Co-Cr alloy powder has an average diameter $100{\mu}m$, Ni-Cr alloy powder was found to have the form of sphere having an average diameter $50{\mu}m$. 2. Co-Cr alloy and Ni-Cr alloy block produced by low-temperature processing showed a certain ratio. 3. In the XRD study, Co phase appeared in Co-Cr alloy block after sintering. and Cr2Ni3 phase appeared in Ni-Cr alloy block after sintering.

Factors affecting job stress and physical symptoms of dental technicians in Daegu Metropolitan City (대구지역 치과기공사의 직무스트레스와 신체증상에 영향을 미치는 요인)

  • Lee, Deog-Su;Kim, Chang-Yoon;Lee, Kyeong-Soo;Hwang, Tae-Yoon
    • Journal of Technologic Dentistry
    • /
    • v.33 no.4
    • /
    • pp.453-466
    • /
    • 2011
  • Purpose: This study aims to investigate the general characteristics of dental technicians and their health behaviors and to analyze the related factors of their work stress and physical symptoms. Methods: The survey used structured self administered questionnaires for a survey targeting 741 members registered of the Dental Technician Association in Daegu Metropolitan City from September to October, 2009. Total of 518 replies and analyzed 490 questionnaire excluding 28 incomplete questionnaires. Results: The work stresses were higher in those who answered that they were under 30-years old, unmarried, lower in rank, or had longer work hours, lower monthly incomes or poor self-perceived health status. In addition, those who worked in a dental laboratory with poor work environment including insufficient ventilation, sand blaster with no powder collecting functions, etc., tended to experience higher work stress than others due to their work conditions. The total average of the respondents of the survey who answered that they suffered from some physical symptoms was 14.7 points. It was found that the factors affecting the score of physical symptoms include occupational features such as work hours, monthly income, etc., and physical work environment such as the presence or absence of ventilator, of dust-collectors within sand blaster, etc., and work stress, exerted significant influence. Conclusion: The outcomes of this study indicates that to lessen work stress and to ultimately alleviate physical symptoms, it is necessary to do the following: improve work environment of young unmarried women; adjust their daily working hours; ameliorate physical work environment. To improve overall physical symptoms, it is importance to establish a safe and healthy working environment.

Relationship between the oral contraceptive pill and periodontal disease in Korean women: The 5th Korean National Health and Nutrition Survey data analysis phase3(2012) (경구피임약을 복용하는 한국여성과 치주질환의 관련성 연구: 제5기 3차년도(2012) 국민건강영양조사 자료 분석)

  • Lee, Jong-Hwa;Yoo, Jin-Yeong;Jung, Gi-Ok;Park, Ji-Young
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.6
    • /
    • pp.795-804
    • /
    • 2014
  • Objectives: The purpose of the study was to investigate the relationship between the oral contraceptive pill and periodontal disease in Korean women aged from 19 to 50 years old. Methods: This study selected 1,579 women of childbearing age from 19 to 50 years old from the 5th National Health and Nutrition Survey data analysis(phase 3, 2012) taking the oral examination. The questionnaire consisted of socioeconomic demographic characteristics, health behavior, use of oral contraceptive pills, and periodontal disease. Socioeconomic demographic characteristics included age, marital status, education, monthly income, and vocation. The health behavior included obesity, stress, smoking, subjective oral health status, use of dental floss, tooth brushing, and diabetes mellitus by fasting blood sugar level. Use of oral contraceptive pills was recorded by monthly use and duration. The periodontal disease was documented by yes or no and selected as dependent variable by logistic regression analysis. Results: After revising the taking period of oral contraceptive pill for this study, there was the correlation between the prevalence of periodontal disease and odds ratio(95% CI) 1.288(1.027-1.617). Conclusions: This study will contribute to the direction of policy for an oral contraceptive pill and provide the basic data for counseling for the oral health and the side effects of oral contraceptive pills.

Comparison of stress distribution in bone and implant-supported dental prosthesis with zirconia and titanium implants: a 3-dimensional finite element analysis (지르코니아 및 티타늄 임플란트를 사용한 지지골 및 임플란트 유지 수복물의 응력 분포 비교: 3차원 유한 요소 분석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.348-354
    • /
    • 2020
  • Purpose: Zirconia is differentiated from other ceramics because of its high resistance to corrosion and wear, excellent flexural strength (900~1400 MPa), and high hardness. Dental zirconia with proven mechanical/biological stability is suitable for the manufacture of implants. However, there are limited in vivo studies evaluating stress distribution in zirconia compared with that in titanium implants and studies analyzing finite elements. This study was conducted to evaluate the stress distribution of the supporting bone surrounding zirconia and titanium implants using the finite element analysis method. Methods: For finite element analysis, a single implant-supported restoration was designed. Using a universal analysis program, eight occlusal points were set in the direction of the occlusal long axis. The occlusal load was simulated at 700 N. Results: The zirconia implant (47.7 MPa) von Mises stress decreased by 5.3% in the upper cortical bone compared with the titanium implant (50.2 MPa) von Mises stress. Similarly, the zirconia implant (20.8 MPa) von Mises stress decreased by almost 4% in the cancellous bone compared with the titanium implant (21.7 MPa) von Mises stress. The principal stress in the cortical and cancellous bone exhibited a similar propensity to von Mises stress. Conclusion: In the supporting bone, the zirconia implant is able to reduce bone resorption caused by mechanically transferred stress. It is believed that the zirconia implant can be a potential substitute for the titanium implant by reinforcing aesthetic characteristics and improving stress distribution.

Effects of titanium and PEEK abutments on implant-supported dental prosthesis and stress distribution of surrounding bones: three-dimensional finite element analysis (티타늄 및 PEEK 지대주 소재가 임플란트 유지 수복물 및 주위 지지골 응력 분포에 미치는 영향: 3차원 유한요소해석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.44 no.3
    • /
    • pp.67-75
    • /
    • 2022
  • Purpose: This study aimed to comparatively evaluate the stress distribution of bones surrounding the implant system to which both titanium and polyetheretherketone (PEEK) abutments are applied using a three-dimensional finite element analysis. Methods: The three-dimensional implant system was designed by the computer-aided design program (CATIA; Dassault Systemes). The discretization process for setting nodes and elements was conducted using the HyperMesh program (Altair), after finishing the design of each structure for the customized abutment implant system. The results of the stress analysis were drawn from the Abaqus program (Dassault Systèmes). This study applied 200 N of vertical load and 100 N of oblique load to the occlusal surface of a mandibular first molar. Results: Under external load application, the PEEK-modeled dental implant showed the highest von Mises stress (VMS). The lowest VMS was observed in the Ti-modeled abutment screws. In all groups, the VMS was observed in the crestal regions or necks of implants. Conclusion: The bones surrounding the implant system to which the PEEK abutment was applied, such as the cortical and trabecular bones, showed stress distribution similar to that of the titanium implant system. This finding suggests that the difference in the abutment materials had no effect on the stress distribution of the bones surrounding implants. However, the PEEK abutments require mechanical and physical properties improved for clinical application, and the clinical application is thought to be limited.

Elemental alteration of the surface of dental casting alloys induced by electro discharge machining (치과용 주조 합금의 방전가공에 따른 표면 성분 변화)

  • Jang, Yong-Chul;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.55-61
    • /
    • 2009
  • Passive fitting of meso-structure and super-structures is a predominant requirement for the longevity and clinical success of osseointegrated dental implants. However, precision and passive fitting has been unpredictable with conventional methods of casting as well as for corrective techniques. Alternative to conventional techniques, electro discharge machining(EDM) is an advanced method introduced to dental technology to improve the passive fitting of implant prosthesis. In this technique material is removed by melting and vaporization in electric sparks. Regarding the efficacy of EDM, the application of this technique induces severe surface morphological and elemental alterations due to the high temperatures developed during machining, which vary between $10,000{\sim}20,000^{\circ}C$. The aim of this study was to investigate the morphological and elemental alterations induced by EDM process of casting dental gold alloy and non-precious alloy used for the production of implant-supported prosthesis. A conventional clinical dental casting alloys were used for experimental specimens patterns, which were divided in three groups, high fineness gold alloy(Au 75%, HG group), low fineness gold alloy(Au 55%, LG group) and nonprecious metal alloy(Ni-Cr, NP group). The UCLA type plastic abutment patterns were invested with conventional investment material and were cast in a centrifugal casting machine. Castings were sandblasted with $50{\mu}m\;Al_2O_3$. One casting specimen of each group was polished by conventional finishing(HGCON, LGCON, NPCON) and one specimen of each group was subjected to EDM in a system using Cu electrodes, kerosene as dielectric fluid in 10 min for gold alloy and 20 min for Ni-Cr alloy(HGEDM. LGEDM, NOEDM). The surface morphology of all specimens was studied under an energy dispersive X-ray spectrometer (EDS). The quantitative results from EDS analysis are presented on the HGEDM and LGEDM specimens a significant increase in C and Cu concentrations was found after EDM finishing. The different result was documented for C on the NPEDM with a significant uptake of O after EDM finishing, whereas Al, Si showed a significant decrease in their concentrations. EDS analysis showed a serious uptake of C and Cu after the EDM procedure in the alloys studied. The C uptake after the EDM process is a common finding and it is attributed to the decomposition of the dielectric fluid in the plasma column, probably due to the development of extremely high temperatures. The Cu uptake is readily explained from the decomposition of Cu electrodes, something which is also a common finding after the EDM procedure. However, all the aforementioned mechanisms require further research. The clinical implication of these findings is related with the biological and corrosion resistance of surfaces prepared by the EDM process.

  • PDF

Difference of Translucency according to Drying Time after Staining of Dental Zirconia (치과용 지르코니아 착색 후 건조시간에 따른 반투명도의 차이)

  • Lee, Joo-Hee;Park, Jin-Young;Kim, Dong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.124-130
    • /
    • 2021
  • Dental prosthesis translucency importantly contributes to aesthetic outcomes. The purpose of this study was to investigate the effect of drying time and zirconia coloring agent type on translucency. For the experiment, 90 circular specimens were fabricated for each zirconia block. Then, zirconia specimens were treated with a coloring agent for 180 seconds and dried for 0 seconds (undried), 30 seconds (intermediate dry), or 30 minutes (complete dry). Then, a specimen was placed on a black standard tile or a white standard tile, and using a standard D65 light source reflected was measured using the light removal method. A total of three repeated measurements were obtained per specimen. One-way ANOVA was used to compare and analyze the relationship between zirconia translucency and drying time. Zirconia and coloring liquid types were significantly associated with translucency (P < 0.001). Although no significant difference was observed with respect to drying time (P > 0.922), zirconia in the completely dried (30 minutes) state was more translucent.

Research for Thickness Change of Denture Base in Flask when Injecting Valplast Flexible Partial Denture Resin (발플라스트 레진 주입 시 발생되는 의치상의 두께변화에 관한 연구)

  • Jang, Wan-Young;Kim, Bu-Sob;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.30 no.2
    • /
    • pp.47-56
    • /
    • 2008
  • This is a research for thickness change of denture base according to the shape of sprue & investment position of denture base in flask when injecting polyamid base resin for flexible partial denture as a part of study for Valplast among the flexible partial denture with a nylon base. It has been introduced several kinds of flexible partial denture product with a nylon base, but Valplast is the most widely used product among them. Valplast has been the most generally used material today since developed in 1950s in the United States as a material for flexible partial denture. Valplast is much more aesthetic than general metal-acrylic partial denture due to its translucent pink color and biocompatibility in terms of material characteristic. It keeps its flexibility for a long time after production, imposes a less burden on the teeth used as abutment, and it can be easily insert and remove due to its particular suppleness. Moreover, it is felt like real teeth more than metal-acrylic partial denture when being put in and takes alveolar bone under good protection since it receives occlusal force equally under the denture base. The most outstanding feature of Valplast is flexibility. The extent of its flexibility is determined by width & thickness of denture base. Considering general working procedure of Valplast, it can be seen that the thickness of denture base formed out of wax is increasing by the pressure while injecting resin. This research is to decide and test on the thickness increasing of Valplast by injecting pressure and the hypothesis upon that and is to prepare the basis estimating the increasing extent of thickness of denture base on the basis of the test result. In this test, it is expected occlusal malposition & thickness increasing of denture base by injecting pressure according to 4 kinds of test data which are to select 3 types of sprue method settling the forefront position at which the test material of fixed standard can be invested and to position the test material at the rearmost part keeping the minimum distance to set sprue. For 4 kinds of injecting test by investment position & sprue type, 20 test materials, 5 for each test were produced and a pressure of 1,180Kg was given with automatic injector of air cylinder type. The results are as follows: 1. For the amount of thickness increasing of denture base by investment position, the thickness of front investment is less increasing than the one of rear investment. 2. For the amount of thickness increasing of denture base by sprue type, the thickness of straight decompression sprue type which can absorb the injecting pressure after injecting polyamide base resin is less increasing than the other sprue types.

  • PDF

CORROSION PHENOMENA OF MAGNETIC ATTACHMENT USED IN ORAL ENVIRONMENT (구강 환경에서 사용된 자성 Dyna 어태치먼트의 부식현상)

  • Kwak Jong-Ha;Chung Chae-Heon;Choe Han-Cheol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.470-483
    • /
    • 2002
  • The purpose of this study was to investigate further the mechanics of failure of magnets used for denture retention. Dyna magnets were retrived from denture that had failed after 34 months of clinical use. The magnets were observed and sectioned in order to analyse with high resolution scanning electron microscope. From this study, corrosion behaviors of used magnetic attachment were analysed. The results were as follows ; 1. In Nd-Fe-B based magnetic materials, the erosion-corrosion was started at ununiformed part of stainless steel cover. 2. Corrosion was initiated at weared stainless steel surface and then magnetic materials were spalled by corrosive solution. 3. Spatting was occurred in Nd-Fe-B magnet materials due to corrosion products and then corrosion rate was increased drastically. 4. Corrosion started from ununiformed stainless steel surface as well as welded zone. In conclusion, the failure of magnets may occur by either breakdown of the welding or breakdown of the encapsulating material. So, it is considered that the corrosion problem of dental magnetic materials could be solved to some extent with surface treatment of dental magnetic materials.