• 제목/요약/키워드: Dental Implant Material

검색결과 367건 처리시간 0.024초

입자크기를 달리한 Cp-Ti의 미세구조 관찰 및 SBF하에서의 부식거동 (Microstructure and Corrosion Behavior of Various Grain Size Cp-Ti)

  • 이승우;김윤종;류재경;박중근;김원수;김택남
    • 한국재료학회지
    • /
    • 제15권9호
    • /
    • pp.585-588
    • /
    • 2005
  • Titanium and Titanium alloys are widely used as an orthopedic and dental implant material because of their excellent biocompatibility and mechanical strength. In this study, ECAP Cp-Ti and Cp-Ti were heat treated for different annealing time of 30 min, 90 min and 3 hours. The grain size for each condition was studied. The micro-Vicker hardness test was carried out f3r each different heat treated samples. The micro-Vicker hardness test for ECAP Cp-Ti, Cp-Ti and Cp-Ti (3hr) revealed hardness values of 239.5, 182 and 144 Hv, respectively. The grain size was increased from approximately $70{\mu}m\;to\;300{\mu}m$ with the increase in heat treatment time from 30 min to 3 hours. The heat treated samples were tested for their biocompatibility in simulated body fluid (SBF) and corrosion rates was determined using Polarization Curve test (PCT). The PCT results showed Cp-Ti with comparatively high corrosion potential of -0.18 V and corresponding corrosion current of $2\times10^{-6}$ A, while the corrosion rate in ECAP Cp-Ti and Cp-Ti (30 min annealed) showed very similar results of corrosion potential about -0.47 V with corresponding corrosion current of $7\times10^{-8}$ A.

Alveolar ridge preservation with an open-healing approach using single-layer or double-layer coverage with collagen membranes

  • Choi, Ho-Keun;Cho, Hag-Yeon;Lee, Sung-Jo;Cho, In-Woo;Shin, Hyun-Seung;Koo, Ki-Tae;Lim, Hyun-Chang;Park, Jung-Chul
    • Journal of Periodontal and Implant Science
    • /
    • 제47권6호
    • /
    • pp.372-380
    • /
    • 2017
  • Purpose: The aim of this prospective pilot study was to compare alveolar ridge preservation (ARP) procedures with open-healing approach using a single-layer and a double-layer coverage with collagen membranes using radiographic and clinical analyses. Methods: Eleven molars from 9 healthy patients requiring extraction of the maxillary or mandibular posterior teeth were included and allocated into 2 groups. After tooth extraction, deproteinized bovine bone mineral mixed with 10% collagen was grafted into the socket and covered either with a double-layer of resorbable non-cross-linked collagen membranes (DL group, n=6) or with a single-layer (SL group, n=5). Primary closure was not obtained. Cone-beam computed tomography images were taken immediately after the ARP procedure and after a healing period of 4 months before implant placement. Radiographic measurements were made of the width and height changes of the alveolar ridge. Results: All sites healed without any complications, and dental implants were placed at all operated sites with acceptable initial stability. The measurements showed that the reductions in width at the level 1 mm apical from the alveolar crest (including the bone graft) were $-1.7{\pm}0.5mm$ in the SL group and $-1.8{\pm}0.4mm$ in the DL group, and the horizontal changes in the other areas were also similar in the DL and SL groups. The reductions in height were also comparable between groups. Conclusions: Within the limitations of this study, single-layer and double-layer coverage with collagen membranes after ARP failed to show substantial differences in the preservation of horizontal or vertical dimensions or in clinical healing. Thus, both approaches seem to be suitable for open-healing ridge preservation procedures.

기계적 표면 처리된 TITANIUM PLASMA SPRAYED IMPLANT에 대한 치은섬유아세포전개양상의 형태학적 관찰 (THE MORPHOLOGICAL OBSERVATION OF HUMAN GINGIVAL FIBROBLASTS ATTACHMENT AND SPREADING ON THE MECHANICAL TREATED TITANIUM PLASMA SPRAYED IMPLANT SURFACE)

  • 황연희;이재목;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제25권3호
    • /
    • pp.741-755
    • /
    • 1995
  • 구강내 매식된 임프란트가 과도한 교합력이나 염증등의 이유로 구강내로 노출되었을 때 세균독소에 이완된 면을 제거하고 평활한 면을 형성하여 주위의 연조직, 경조직에 적합한 상태로 만들어 건강한 상태로 구강내에 유지하기 위해서 임프란트 매식체 표면을 기계적인 표면처리방법으로 처치하여 이러한 방법이 임프란트 표면성분, 치은섬유아세포의 전개양상에 미치는 영향을 알아보고자 본 실험을 실행하였다. IMZ사에서 제작한 직경 10mm, 높이 2mm의 원판 타이타늄을 이용하여 피막되지 않은 타이타늄면과 TPS면을 대조군으로 하고 기계적인 표면처리방법인 low speed stone bur처치면을 실험군으로 설정한 후 EDX로 타이타늄 표면성분을 분석하였고 주사전자현미경으로 치은섬유아세포의 전개양상을 관찰하였다. EDX에 의한 타이타늄 표면성분분석 결과 모든 실험군에서 titanium peak, 소량의 aluminum이 나타났으며 그외의 성분은 나타나지 않았다. 치은섬유아세포의 전개양상에 대한 주사전자현미경 관찰결과 평활한 타이타늄면에서 접종 30분 후 세사상돌기와 박판엽상으로 확장된 세포가 많이 관찰되며 6시간 후 신장된 치은섬유아세포가 시편에 밀착된 양상을 보였고 24시간 후 치은섬유아세포는 시편의 모든 면을 피개하며 가공시의 평행한 선을 따라 방향성을 띄었다. TPS가 잔존한 stone처치군에서 세포 접종 30분 후 세사상돌기가 적게 관찰되어 평활한 타이타늄면에 비해 초기부착이 늦은 것을 알 수 있었고 6, 24시간후 치은섬유아세포는 거친면으로 인해 시편에 밀착되지 못한 양상을 보였으나 평활한 타이타늄면과 연결되며 시편의 모든면을 피개하였다. TPS군에서 치은섬유아세포는 세포 접종 30분후 세사상돌기를 거의 찾아 볼 수 없어 초기부착이 다른군에 비해 늦으며 세포배양 6, 24시간후에도 시편에 밀착되지 못하고 박판상돌기가 가늘고 길게 돌출되어 여러면에 부착된 양상을 보였으며 세포가 부착되지 않은 TPS면이 관찰되었다.

  • PDF

미니 임플란트 직경에 따른 피로파절강도의 비교 연구 (Comparison of fatigue fracture strength by fixture diameter of mini implants)

  • 허유리;손미경;김희중;최한철;정재헌
    • 대한치과보철학회지
    • /
    • 제50권3호
    • /
    • pp.156-161
    • /
    • 2012
  • 연구 목적: 일체형의 o-ring type 미니 임플란트 고정체의 직경에 따른 파절강도의 차이를 비교하고자 한다. 연구 재료 및 방법: 길이 13mm의 one body o-ring type의 미니 임플란트(Dentis, Daegu, Korea)를 직경 2.0, 2.5, 3.0mm 각각 5개씩 준비하였다. Instron universal testing machine에 수직면에서 30도 각도로 샘플을 위치시키고 off-axis loading을 가하여 영구변형이 일어난 하중 값을 파절강도로 하고 5개의 시편의 평균을 구하여 각 직경에 따른 임플란트의 고정체의 파절강도를 비교하였다. 또한, 각 직경마다 3개의 시편을 준비하고 동적하중 피로 시험기를 이용하여, 파절이 발생할 때까지 파절강도의 80%, 60%, 40%의 loading을 가하여 파절되는 cycle수를 측정하여 각 직경의 피로 파절을 분석하였다. 추가적으로 총의치의 평균 저작력인 43 N의 하중을 가하여 파절되는 cycle 수를 측정하였다. 각 군간의 차이를 검증하기 위해서 일원분산분석(one-way ANOVA test)을 시행하였고, 통계처리는 SPSS ver.12 (SPSS Inc. Chicago, IL, USA) 을 이용하여 실시하였다. 결과: 직경 3.0mm의 미니 임플란트는 평균 $276.0{\pm}13.4N$의 압축력을 받았을 때 영구 변형이 일어났고 직경 2.5mm 미니 임플란트가 $149.0{\pm}6.1N$, 2.0mm 미니 임플란트가 $101.5{\pm}14.6N$일 때 영구 변형이 일어났다. 각 군간의 파절강도에는 유의한 차이가 있었다(P<.001). 총의치의 평균 저작력 하중에서 실시한 피로 파절 실험 결과, 세직경 모두 $5{\times}10^6cycle$까지 파절이 일어나지 않았다. 결론: 미니 임플란트의 정적 하중 하에서 최대 압축강도는 직경이 증가할수록 유의적으로 증가하였다. 최대 압축강도는 세 직경 모두 총의치의 평균 저작력 보다는 크나 최대 교합력보다는 직경 3.0mm에서만 크게 나타났다. 총의치의 평균 저작력 하중에서 실시한 피로 파절 실험 결과, 세 직경 모두 파절이 일어나지 않았다.

두 종의 external hex implant의 변연골 흡수에 관한 연구 : 예비연구 (preliminary study) (Radiographic evaluation of marginal bone resorption around two types of external hex implants : preliminary study)

  • 이지은;허성주;곽재영;김성균;한종현
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.169-174
    • /
    • 2008
  • 목적: 치과 임플랜트 주위의 변연골 변화는 임플랜트의 기능적인 유지 뿐만 아니라 심미적 성공을 위해서도 중요하다. 변연골의 유지를 위한 임플랜트 디자인이 연구되고 있다. 이번 예비 연구는 두 종류의 external hex implant 시스템에서 임플랜트의 상부 미세 나사산이 변연골 변화량에 미치는 영향을 평가하고자 한다. 재료 및 방법: 총 24명의 환자를 대상으로 $Br{{\aa}}nemark$ 임플랜트 식립군 (1군, 거친 표면 임플랜트, 20개)과 원플란트 임플랜트 식립군 (2군, 미세나사산을 가진 거친 표면 임플랜트, 20개)으로 분류하였다. 기준 시점 (임플랜트 부하)과 부하를 가한 1년 뒤 임상적, 방사선학적 검사를 시행하였다. UTHSCSA Image Tool을 이용하여 임플랜트-보철 경계부로부터 변연골 높이 변화량으로 계측하였다. 계측치는 SAS 프로그램을 이용하여 three-level ANCOVA로 통계처리 하였다. 결과: 기준 시점과 비교하여 1년 기능 후, 두 그룹 간의 변연골 소실 변화량에 있어서 통계학적으로 유의한 차이가 있었다 (P<0.05). 1군의 평균 변연골 높이 변화량은 $0.83{\pm}0.31mm$, 2군에 있어서는 $0.44{\pm}0.36mm$ 이었다. 미세나사산을 가진 거친 표면 임플랜트가 미세나 사산을 가지지 않은 거친 표면 임플랜트 보다 더 적은 변연골 소실 변화량을 보였다. 결론: 미세나사산을 가진 거친 표면 임플랜트가 기능적 부하 후 변연골 높이를 유지하는데 있어 더 유리한 디자인으로 보인다.

다양한 골이식재료를 이용한 상악동 골이식 4개월 후 조직형태계측학적 평가 (Histomorphometric Study of Sinus Bone Graft using Various Graft Material)

  • 이지영;김영균;김수관;임성철
    • 구강회복응용과학지
    • /
    • 제27권2호
    • /
    • pp.141-147
    • /
    • 2011
  • 본 연구는 상악동골이식술에 사용된 다양한 골이식재와 자가치아골이식재의 효율성을 비교하고 조직형태계측학적으로 평가하는 것이다. 2007년 10월부터 2009년 9월까지 분당서울대학교병원에서 상악동골이식술을 시행 받은 24명의 환자들을 대상으로 하였다. 환자들의 평균 나이는 $52.51{\pm}11.86$세였다. 모든 증례들은 사용된 골이식재의 종류에 따라 3그룹으로 분류되었다. 1군: 자가치아골이식재, 2군: OrthoblastII(integra lifescience corp. Irvine, US)+Biocera(Osscotec, seoul, korea), 3군: DBX(Synthes, USA)+BioOss(Geistlich Pharm AG, Wolhusen, Switzerland). 총 37개의 임프란트가 식립되었다(1군: 7, 2군: 10, 3군: 20). 신생골 형성, 직골과 층판골의 비율, 신생골과 골이식재의 비율을 조직형태계측학적으로 평가하였다. 통계처리는 SPSS Ver. 12.0을 사용하여 Kruskal-Wallis test를 시행하였다. 신생골 형성 비율은 1군 $52.5{\pm}10.7$, 2군 $52.0{\pm}23.4$, 3군 $51.0{\pm}18.3$였고 통계적으로 유의성 있는 차이는 없었다. 직골과 층판골의 비율은 1군 $82.8{\pm}15.3$, 2군 $36.7{\pm}59.3$, 3군 $31.0{\pm}51.2$였다. 신생골과 잔존골이식재의 비율은 1군 $81.3{\pm}10.4$, 2군 $72.5{\pm}28.8$, 3군 $80.3{\pm}24.0$였다. 4개월의 치유기간 후에 모든 군에서 양호한 신생골 형성이 이루어졌다. 본 연구의 제한적인 범위 내에서 자가치아골이식재는 상악동골이식에 사용될 수 있는 새로운 골이식재료라고 사료된다.

전자빔 용해 방법으로 제조된 정형외과 임플란트용 Ti-6Al-4V 합금의 재료 특성 분석 (Material Characteristics of Ti-6Al-4V Alloy Manufactured by Electron Beam Melting for Orthopedic Implants)

  • 강관수;정용훈;장태곤;양재웅;정재영;박광민;우수헌;박태현
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.25-25
    • /
    • 2018
  • Electron beam melting (EBM) is one of powder based additive manufacturing technology used to produce parts for high geometrical complexity and directly with three-dimensional computer aided design (CAD) model. It is kind of the most promising methods with additive manufacturing for a wide range of medical applications, such as orthopedic, dental implant, and etc. This research has been investigated the microstructure and mechanical properties of as fabricated and hot iso-static pressing (HIP) processed specimens, which are made by an Arcam A1 EBM system. The Ti-6Al-4V titanium alloy powder was used as a material for the 3 dimensional printing specimens. Mechanical properties were conducted with EBM manufacturing and computer numerical control (CNC) machining specimens, respectively. Surface morphological analysis was conducted by scanning electron microscopy (SEM) for their surface, dissected plan, and fractured surface after tensile test. The mechanical properties were included tensile stress-strain and nano-indentation test as a analysis level between nano and macro. As following highlighted results, the stress-strain curves on elastic region were almost similar between as fabricated and HIP processed while the ductile (plastic deformed region) properties were higher with HIP than that of as fabricated processed.

  • PDF

Cone-beam computed tomographic evaluation of dimensional hard tissue changes following alveolar ridge preservation techniques of different bone substitutes: a systematic review and meta-analysis

  • Pickert, Finn Niclas;Spalthoff, Simon;Gellrich, Nils-Claudius;Tarraga, Juan Antonio Blaya
    • Journal of Periodontal and Implant Science
    • /
    • 제52권1호
    • /
    • pp.3-27
    • /
    • 2022
  • Purpose: This study was conducted to evaluate and compare the effects of different graft materials used in alveolar ridge preservation on dimensional hard tissue changes of the alveolar ridge, assessed using cone-beam computed tomography (CBCT) scans. Methods: A systematic electronic search of MEDLINE and the Cochrane Central Register of Controlled Trials and a manual search were conducted from November 2019 until January 2020. Randomized controlled trials were included if they assessed at least 1 variable related to vertical or horizontal hard tissue changes measured using CBCT scans. After a qualitative analysis of the included studies, subgroups were formed according to the graft material used, and a quantitative analysis was performed for 5 outcome variables: changes in vertical alveolar bone height at 2 points (midbuccal and midpalatal/midlingual) and changes in horizontal (buccolingual) alveolar bone width at 3 different levels from the initial crest height (1, 3, and 5 mm). Results: The search resulted in 1,582 studies, and after an independent 3-stage screening, 16 studies were selected for qualitative analysis and 9 for quantitative analysis. The metaanalysis showed a significantly (P<0.05) lower reduction of alveolar ridge dimensions for the xenogenic subgroup than in the allogenic subgroup, both vertically at the midbuccal aspect (weighted mean difference [WMD]=-0.20; standard error [SE]=0.26 vs. WMD=-0.90; SE=0.22) as well as horizontally at 1 mm (WMD=-1.32; SE=0.07 vs. WMD=-2.99; SE=0.96) and 3 mm (WMD=-0.78; SE=0.11 vs. WMD=-1.63; SE=0.40) from the initial crest height. No statistical analysis could be performed for the autogenic subgroup because it was not reported in sufficient numbers. Conclusions: Less vertical and horizontal bone reduction was observed when xenogenic graft materials were used than when allogenic graft materials were used; however, the loss of alveolar ridge dimensions could not be completely prevented by any graft material.

Biomineralization of three calcium silicate-based cements after implantation in rat subcutaneous tissue

  • Ranjdar Mahmood Talabani;Balkees Taha Garib;Reza Masaeli;Kavosh Zandsalimi;Farinaz Ketabat
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.1.1-1.13
    • /
    • 2021
  • Objectives: The aim of this study was to evaluate the dystrophic mineralization deposits from 3 calcium silicate-based cements (Micro-Mega mineral trioxide aggregate [MM-MTA], Biodentine [BD], and EndoSequence Root Repair Material [ESRRM] putty) over time after subcutaneous implantation into rats. Materials and Methods: Forty-five silicon tubes containing the tested materials and 15 empty tubes (serving as a control group) were subcutaneously implanted into the backs of 15 Wistar rats. At 1, 4, and 8 weeks after implantation, the animals were euthanized (n = 5 animals/group), and the silicon tubes were removed with the surrounding tissues. Histopathological tissue sections were stained with von Kossa stain to assess mineralization. Scanning electron microscopy and energy-dispersive X-ray spectroscopy (SEM/EDX) were also used to assess the chemical components of the surface precipitates deposited on the implant and the pattern of calcium and phosphorus distribution at the material-tissue interface. The calcium-to-phosphorus ratios were compared using the non-parametric Kruskal-Wallis test at a significance level of 5%. Results: The von Kossa staining showed that both BD and ESRRM putty induced mineralization starting at week 1; this mineralization increased further until the end of the study. In contrast, MM-MTA induced dystrophic calcification later, from 4 weeks onward. SEM/EDX showed no statistically significant differences in the calcium- and phosphorus-rich areas among the 3 materials at any time point (p > 0.05). Conclusions: After subcutaneous implantation, biomineralization of the 3-calcium silicate-based cements started early and increased over time, and all 3 tested cements generated calcium- and phosphorus-containing surface precipitates.

SLA 표면 처리 및 외측 연결형의 국산 임플랜트에 대한 임상적, 방사선학적 평가 (Clinical and radiographic evaluation of $Neoplan^{(R)}$ implant with a sandblasted and acid-etched surface and external connection)

  • 안희석;문홍석;심준성;조규성;이근우
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.125-136
    • /
    • 2008
  • 골유착 개념에 기반한 치과용 임플랜트가 $Br{\aa}nemark$ 등에 의해 도입된 이후로 치과 치료에서 임플랜트를 이용한 방법은 장기적으로 높은 성공률을 보여 왔다. 임플랜트를 이용한 치료법이 상실된 치아의 수복을 위해 우선적으로 고려되어야 할 중요한 방법으로 인식되면서 임플랜트를 이용한 방법을 선호하게 되었고 적용 범위 및 사용 빈도도 급증하였다. 예전에 비해서 국산 임플랜트의 사용도 증가하였으나 장기간의 임상적, 객관적인 자료를 가진 국산 임플랜트의 수는 많지 않은 상태이다. 본 연구는 SLA 표면 처리 및 외측 연결형의 국산 임플랜트에 관하여 18개월에서부터 57개월까지의 임상적, 방사선학적 결과에 대한 후향적 분석을 실시하였다. 연세대학교 치과대학병원에서 네오플란트$^{(R)}$ 임플랜트 (네오바이오텍, 서울, 한국)를 이용하여 치료받은 25명의 환자에게 식립된 96개의 임플랜트를 대상으로 하였고, 대상자 중 남성의 평균 연령은 63.5세, 여성의 평균 연령은 44.3세였다. 진료기록부를 통해 성별, 연령, 무치악 유형, 식립 위치, 식립된 임플랜트의 직경 및 길이, 2차 수술 여부, 보철물의 유형, 대합치의 유형, 임상적 합병증의 종류 및 빈도 등을 조사하여 그에 따른 분포 및 생존율의 차이와 함께 이들 항목이 변연골 흡수량에 미치는 영향을 조사하여 다음과 같은 결과를 얻었다. 1. 총 25명에게 식립된 96개의 임플랜트 중 2개가 실패하여 누적 생존율은 97.9%로 나타났다. 2. 정기검진이 가능했던 88개의 임플랜트에 대해서는 상악에서의 생존율이 96.2%, 하악에서의 생존율은 98.4%였고, 구치부에서의 생존율은 97.5%였으며 전치부에서의 생존율은 100%였다. 3. 보철물 장착 후 1년과 1년 이후의 연간 흡수량에서 남성이 여성보다 변연골 흡수량이 많았다 (P<0.05). 4. 임플랜트 지지 보철물 후방에 자연치가 존재하는 경우가 존재하지 않는 경우보다 보철물 장착 후 첫 1년과 1년 이후 모두에서 연간 흡수량이 적었다 (P<0.05). 5. 보철물 장착 1년 이후의 연간 흡수량은 전치보다 구치에서 더 많은 변연골 흡수를 보였다 (P<0.05). 6. 악궁 간, 보철물의 유형, 대합치의 유형, 2차 수술 여부에 따른 변연골 흡수량의 차이는 보이지 않았다 (P>0.05). 이상의 결과를 토대로 변연골 흡수량에 영향을 주는 요소로 성별, 무치악의 유형, 악궁 내 위치였으며, 악궁 간, 보철물의 유형, 대합치의 유형, 2차 수술 여부에 따른 변연골 흡수량 차이는 없었다. 본 연구에서 최대 57개월까지의 기간 동안 SLA 표면 처리 및 외측 연결형의 국산 임플랜트의 임상적인 성공률은 만족스러운 결과를 보였으며 변연골 흡수량도 임플랜트 성공기준에 부합하였으나, 이보다 더 장기적인 평가가 필요하며 다양한 국산 임플랜트 시스템에 대한 중장기적인 연구가 지속되어야 할 것이다.