• Title/Summary/Keyword: Dental Implant Material

Search Result 366, Processing Time 0.024 seconds

Abrasion of abutment screw coated with TiN

  • Jung, Seok-Won;Son, Mee-Kyoung;Chung, Chae-Heon;Kim, Hee-Jung
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.102-106
    • /
    • 2009
  • STATEMENT OF PROBLEM. Screw loosening has been a common complication and still reported frequently. PURPOSE. The purpose of this study was to evaluate abrasion of the implant fixture and TiN coated abutment screw after repeated delivery and removal with universal measuring microscope. MATERIAL AND METHODS. Implant systems used for this study were Osstem and 3i. Seven pairs of implant fixtures, abutments and abutment screws for each system were selected and all the fixtures were perpendicularly mounted in liquid unsaturated poly-esther with dental surveyor. After 20 times of repeated closing and opening test, the evaluation for the change of inner surface of implant and TiN-coated abutment screw, and weight loss were measured. Mann-Whitney test with SPSS statistical software for Window was applied to analyze the measurement of weight loss. RESULTS. TiN-coated abutment screws of Osstem and 3i showed lesser loss of weight than non-coated those of Osstem and 3i (P < .05, Mann-Whitney test). CONCLUSION. Conclusively, TiN coating of abutment screw showed better resistance to abrasion than titanium abutment screw. It was concluded that TiN coating of abutment screw would reduce the loss of preload with good abrasion resistance and low coefficient of friction, and help to maintain screw joint stability.

A STUDY OF THE EFFECT OF AN ANTI-ROTATIONAL INNER POST SCREW SYSTEMS ON ABUTMENT SCREW LOOSENING FOR SINGLE IMPLANT : PART 1

  • Choi, Sun-Young;Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.345-353
    • /
    • 2007
  • Statement of problem. Implant abutment screw joints tend to loosen under clinical conditions. Abutment screw loosening results in loss of preload in function. Purpose. Anti-rotational inner post screw (ARIPS) systems were compared with conventional abutment screws to reduce screw loosening. Reverse torque values were evaluated. Material and methods. 32 implant assemblies (Warentec, Co, Ltd, Seoul, Korea) were organized as the 30-Ncm-torque conventional groups and 30-Ncm-torque ARIPS groups in external and internal system. The specimens were tested to 106 cycles at a load of 200N. Preload reverse torque, postload reverse torque, and the ratio of postload reverse torque to preload reverse torque were evaluated. The data were analyzed with unpaired t-test in external and internal systems. Results. In the ratio of postload reverse torque to preload reverse torque, the ARIPS groups showed significant differences than the conventional screw group in both external and internal system. Conclusion. Within the limitations of this study, abutment screw loosening was effectively reduced using ARIPS system.

Horizontal Ridge Augmentation using Ridge Expansion and Autogenous Tooth Bone Graft: A Case Report (치조능확장술과 자가치아골이식술을 이용한 치조능 수평증대술: 증례보고)

  • Kim, Young-Kyun;Yi, Yang-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.1
    • /
    • pp.109-115
    • /
    • 2011
  • Implants were placed after performing ridge expansion by inserting screws of gradually increasing thickness. Favorable clinical outcome was obtained. During surgery, buccal cortical plate fracture did not occur. Autogenous tooth bone graft material was grafted around the implant dehiscence defects and over the buccal cortical plate. The method involving the insertion of screws for ridge expansion is a successful and predictable technique for implant placement in narrow alveolar bone. Autogenous tooth bone graft material can be used for ridge augmentation and GBR.

THE PATIENTS' SATISFACTION FOLLOWING IMPLANT TREATMENT

  • Heo, Yoon-Young;Heo, Seong-Joo;Chang, Myung-Woo;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.569-576
    • /
    • 2008
  • STATEMENT OF PROBLEM: While patient-centered outcomes are usually not reported, these may represent major aspects of the implant success for the patient. Use of a well-designed patient survey form can be an invaluable asset to the implant practitioners. PURPOSE: The objective of this study was to investigate patient satisfaction after implant therapy by means of a questionnaire. MATERIAL AND METHODS: South Korean patients (n = 100), who visited the dental examination center of Soon Chun Hyang university hospital, were asked to fill out the satisfaction questionnaire regarding aspects of cost, comfort, esthetics, chewing, gingival health, food impaction, phonetic aspect, screw loosening, and general satisfaction. Responses to statements were given on the Likert response scale. Four experimental groups of patients were distinguished with various location ($A_1,\;A_2,\;A_3$), year ($B_1,\;B_2,\;B_3$), number of implant replacements ($C_1,\;C_2,\;C_3$), and treatment cost ($D_1,\;D_2,\;D_3$). The reliability of the response scales was measured by calculation of its internal consistency, expressed as Cronbach's ${\alpha}$. The scales were distinguished by means of factor analysis method. Possible differences in scale scores among the groups were assessed by One-way ANOVA (${\alpha}$= 0.05). RESULTS: Patients responded to most of the statements with high satisfaction. But the mean scale score of statement about cost was low. After the verification of internal consistency and factor analysis, five components, e.g. general satisfaction, comfort, chewing efficiency, esthetics, and phonetic aspect were grouped together. These components could be explained with common meaning and the first factor was named as 'general satisfaction'. Differences in patient satisfaction on the scale with esthetics were present between patients who have been wearing the implant prosthesis less than three years and those more than seven years ($B_1<B_3$). CONCLUSION: The patients were generally satisfied with the outcome of implant treatment. But the patients' major complaint was high cost and while the statistically significant difference was not shown, the satisfaction scale about food impaction and esthetics was low. So the continuing efforts to make improvements about these problems are needed for the implant practitioners.

Mechanical strength of Zirconia Abutment in Implant Restoration (지르코니아 임플란트 지대주의 기계적 강도에 관한 연구)

  • Shin, Sung-ae;Kim, Chang-Seop;Cho, Wook;Jeong, Chang-Mo;Jeon, Young-Chan;Yun, Ji-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.349-360
    • /
    • 2009
  • Purpose: As the esthetic demands of dental implant patients are increased, the demands of zirconia as implant abutment material are also increased. It has non-metalic color, good biocompatibility, high strength and high toughness. Even thought the advatage of zirconia abutment, there are a few studies about mechanical properties of zirconia abutment. This study evaluated the mecanical strength with compressive bending strength and endurance limit of implant-zirconia abutment assembly. Materials and Methods: Static and cyclic loading of implant-Zirconia abutment assembly were simulated under worst case condition according to ISO. Test groups were implants of external butt joint with straight regular diameter and angled regular diameter zirconia abutment, implant of external butt joint with narrow straight diameter zirconia abutment and implant of internal conical joint with straight narrow diameter zirconia abutment. All test group were evaluated the mecanical strength with compressive bending strength and endurance limit. After fatique testing, fracture surface were examined by SEM. Results: The compressive bending strengths exceed 927N. Regular diameter zirconia abutment were stronger than narrow diameter zirconia abutment(P<.05). The endurance limits ranged from 503N to 868N. Conclusion: Within the limitation of this study, zirconia implant abutment exceeded the estabilished values for maximum incisal biting forces reported in the literature.

TME EFFECT OF MAGNETISM(NEODYMIUM MAGNET) ON BONE FORMATION AROUND TITANIUM IMPLANTS INSERTED INTO THE TIBIA OF RABBIT (Rabbit의 tibia에 매식된 titanium시편 내부에 설치한 희토류 자석의 자성이 주위의 골형성에 미치는 영향에 관한 연구)

  • Park Myung-Won;Lee Sung-Bok;Kwon Kung-Rock;Choi Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.4
    • /
    • pp.519-527
    • /
    • 2005
  • Statement of problem : There are many articles that showed that the magnetism affected the bone formation around titanium implant. It means that a proper magnetism made the osseointegration improved around the implant. So after additional research on the other effect of magnetism on bone formation in implant therapy, we can conclude its possibility of clinical application on implant treatment. Purpose: The purposes of this study were to find out the intensity of magnetic field where magnetism in the titanium implant specimen inserted into the bone could affect the bone formation, and to discover the possibility of clinical application in the areas of dental implants and bone grafts. Material and method: Ten adult male rabbits(mean BW 2Kg) were used in this study. Titanium implant specimens were surgically implanted on the mesial side of the tibia of rabbits. Neodymium magnets(Magnedisc 500, Aichi Steel Corp. Japan) were placed into the implants of experimental group except control group, just after placement of the titanium implants. At 2, 4 and 8 weeks after the surgery, the animals were sacrificed, specimens were obtained and stained with Hematoxylin-Eosin for light microscopic evaluation and histomorphometric analysis. Conclusion : The results were as follows: 1. In radiographic findings, increased radiopacity downward from crestal bone was observed along the titanium implant specimen at experimental period passed by 2, 4, and 8 weeks in both control and experimental group. 2. In histoiogic findings, increased new bone formation was shown in both control and experimental group through the experiment performed for 2, 4, and 8 weeks. More new bone formation and bone remodeling were shown in experimental group. 3. In histomorphometric analysis, the bone contact ratios were 11.9% for control group and 38.5% for experimental group (p<0.05).

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS: HISTOMORPHOMETRIC AND RESONANCE FREQUENCY ANALYSIS IN DOGS

  • Song Woo-Seok;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.671-678
    • /
    • 2004
  • Statement of problem. Reducing treatment time in implant dentistry is a matter of main concern. There are so many factors affecting the success rate of immediate or early loaded implant for the initial bone response. The especially microscopic properties of implant surfaces playa major role in the osseous healing of dental implant. Purpose. The aims of this study were to perform a histologic and histomorphometric comparison of the healing characteristics anodically roughened surface, HA coated surface and RBM surface implant, and to compare of ISQ values measured by $Osstell^{TM}$ for resonance frequency analysis in dogs mandible during 2 weeks. Material and method. Bone blocks from 2 dogs were caught after covered healing for 0 day(2 h); Group I, 1 week; Group II and 2 weeks; Group III. One longitudinal section was obtained for each implant and stained with hematoxylin and eosin. Histomorphometric analysis was done with Kappa Imagebase system to calculate bone-to-implant contact and bone volumes inside the threads. ISQ values were measured in every time of surgery schedule. Conclusion. The experiment revealed that: 1. The percentages of bone-to-implant contact on the fixture in each group were not significantly different(P > 0.05). 2. The percentages of bone area inside the threads on the fixture in each group were not significantly different(P > 0.05). 3. The ISQ level showed clinical stability of each fixture during 2 weeks(all ISQ level ${\geq}71$ ).

Assessing changes of peri-implant bone using digital subtraction radiography

  • Kwon Ji-Yung;Kim Yung-Soo;Kim Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.273-281
    • /
    • 2001
  • Digital subtraction radiography may be one of the most precise and noninvasive methods for assessing subtle density changes in peri-implant bone, providing additional diagnostic information on implant tissue integration in overall maintenance. The aims of this study were to evaluate density changes after first, second surgery of dental implant and to measure the amount of marginal bone loss 9 months after second surgery using digital subtraction radiography. Bone change around 30 screw-shaped implants in 16 patients were assessed on radiographs. 17 Branemark implants of 3.75mm in diameter(Nobel Biocare, Goteborg, Sweden), 2 Branemark implants of 5.0mm in diameter, 11 $Replace^{TM}$ implants of 4.3mm in diameter(Nobel Biocare, Goteborg, Sweden) were used. To standardize the projection geometry of serial radiographs of implants, customized bite block was fabricated using XCP film holder(Rinn Corporation, Elgin, IL.) with polyether impression material of Impregum(ESPE, Germany) and direct digital image was obtained. Qualitative and quantitative changes on radiographs were measured with Emago software(The Oral Diagnostic System, Amsterdam, Netherlands). The results were as follows: 1. The peri-implant bone density of 69.2% implants did not change and the peri-implant bone density of 30.8% implants decreased after 3 months following first surgery. 2. The crestal bone density of 53.9% implants decreased first 3 months after second surgery. The crestal bone density of 58.8% implants increased 9 months after second surgery. No density change was observed around the midportion of the implants after second surgery, 3. The amount of marginal bone loss between different kinds of implants showed no statistically significant differences (p>0.05). 4. More than 90% of total marginal bone loss recorded in a 9-month period occurred during the first 3 months.

  • PDF

EFFECT OF NUMBER OF IMPLANTS AND CANTILEVER DESIGN ON STRESS DISTRIBUTION IN THREE-UNIT FIXED PARTIAL DENTURES: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS

  • Park, Ji-Hyun;Kim, Sung-Hun;Han, Jung-Suk;Lee, Jai-Bong;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.290-297
    • /
    • 2008
  • STATEMENT OF PROBLEM: Implant-supported fixed cantilever prostheses are influenced by various biomechanical factors. The information that shows the effect of implant number and position of cantilever on stress in the supporting bone is limited. PURPOSE: The purpose of this study was to investigate the effect of implant number variation and the effect of 2 different cantilever types on stress distribution in the supporting bone, using 3-dimensional finite element analysis. MATERIAL AND METHODS: A 3-D FE model of a mandibular section of bone with a missing second premolar, first molar, and second molar was developed. $4.1{\times}10$ mm screw-type dental implant was selected. 4.0 mm height solid abutments were fixed over all implant fixtures. Type III gold alloy was selected for implant-supported fixed prostheses. For mesial cantilever test, model 1-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 1-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 1-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with mesial cantilever were simulated. And then, 155N oblique force was applied to the buccal cusp of second premolar. For distal cantilever test, model 2-1 which has three $4.1{\times}10$ mm implants and fixed prosthesis with no pontic, model 2-2 which has two $4.1{\times}10$ mm implants and fixed prosthesis with a central pontic and model 2-3 which has two $4.1{\times}10$ mm implants and fixed prosthesis with distal cantilever were simulated. And then, 206N oblique force was applied to the buccal cusp of second premolar. The implant and superstructure were simulated in finite element software(Pro/Engineer wildfire 2.0). The stress values were observed with the maximum von Mises stresses. RESULTS: Among the models without a cantilever, model 1-1 and 2-1 which had three implants, showed lower stress than model 1-2 and 2-2 which had two implants. Although model 2-1 was applied with 206N, it showed lower stress than model 1-2 which was applied with 155N. In models that implant positions of models were same, the amount of applied occlusal load largely influenced the maximum von Mises stress. Model 1-1, 1-2 and 1-3, which were loaded with 155N, showed less stress than corresponding model 2-1, 2-2 and 2- 3 which were loaded with 206N. For the same number of implants, the existence of a cantilever induced the obvious increase of maximum stress. Model 1-3 and 2-3 which had a cantilever, showed much higher stress than the others which had no cantilever. In all models, the von Mises stresses were concentrated at the cortical bone around the cervical region of the implants. Meanwhile, in model 1-1, 1-2 and 1-3, which were loaded on second premolar position, the first premolar participated in stress distribution. First premolars of model 2-1, 2-2 and 2-3 did not participate in stress distribution. CONCLUSION: 1. The more implants supported, the less stress was induced, regardless of applied occlusal loads. 2. The maximum von Mises stress in the bone of the implant-supported three unit fixed dental prosthesis with a mesial cantilever was 1.38 times that with a central pontic. The maximum von Mises stress in the bone of the implant-supported three-unit fixed dental prosthesis with a distal cantilever was 1.59 times that with a central pontic. 3. A distal cantilever induced larger stress in the bone than a mesial cantilever. 4. A adjacent tooth which contacts implant-supported fixed prosthesis participated in the stress distribution.

A Review of Nanostructured Ca-aluminate Based Biomaterials within Odontology and Orthopedics

  • Hermansson, Leif
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.2
    • /
    • pp.95-107
    • /
    • 2018
  • This presentation will give an overview of Ca-aluminate based biomaterials and their proposed use within the field of nanostructured biomaterials. The paper describes typical features of Ca-aluminate materials with regard to technology, chemistry, biocompatibility including hemocompatibility and bioactivity, and developed microstructure. Special focus will be on the developed microstructure, which is in the nanosize range. Application possibilities within odontology, orthopedics, and drug delivery are presented. The nanostructure including pore size below 5 nm in these structures opens up this material for some use in specific dental-related applications in which antibacterial and bacteriostatic aspects are of importance, and as thin coating on implants within dental and orthopaedic applications. Nanosize porosity is essential in drug delivery systems for controlled release of medicaments. The priority field for Ca-aluminate biomaterials is implant materials, which use minimally-invasive techniques to offer in vivo, on-site developed biomaterials.