• Title/Summary/Keyword: Dental Implant

Search Result 2,738, Processing Time 0.032 seconds

The Use of Autogenous Periosteal Grafts for the Periodontal Regeneration in Mandibular Class II Furcation Defects in the Dog (성견의 2급 치근 분지부 결손에서 자가골막 이식에 의한 치주조직 재생)

  • Nam, Seung-Ji;Chung, Hyun-Ju;Kim, Young-Jun
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.241-257
    • /
    • 2000
  • Autogenous periosteal grafts are an attractive alternative to existing barrier membrane materials since they meet the reqiurements of an ideal material. But no histological data are available on the effectiveness of periosteal membranes in the treatment of periodontal defects. The purpose of this study was to evaluate effect of autogenous periosteal graft on periodontal regeneration histologically. Class II furcation defects were surgically created on the second, third and the fourth premolars bilaterally in the mandibules of six mongrel dogs. The experimental sites were divided into three groups according to the treatment modalities; control group - surgical debridement only; Group I- autogenous periosteal membrane placement after surgical debridement; Group II-autogenous periosteal membrane placement after surgical debridement and bone grafting. The animals were sacrificed at 2, 4 and 12 weeks after periodontal surgery and the decalcified and undecalcified specimens were prepared for histological and histometrical analysis. Clinically all treated groups healed without significant problems. Under light microscope, at 2 weeks, control group showed significant apical epithelial migration and bone remodelling only below the notch area. But for the group I, II with autogenous periosteal graft, less apical migration of epithelium appeared and large amount of osteoid tissue showed above the notch area. Grafted periosteal membrane was indiscernable at 4 weeks, so periosteal membrane might be organized to surrounding tissues. Histometrically, at 4 and 12 weeks, all the test and control groups didn't show significant change of epithelial zone but new attachment level tended to be gained in the test groups than control group. These results suggest that autogenous periosteal grafts should be a good alternative for guided tissue regeneration.

  • PDF

EXPRESSION OF BMP4, BMP6 FOLLOWING SINUS ELEVATION WITH DBBP IN RABBIT (가토 상악동 점막 거상 후 DBBP를 이식재로 사용시 BMP4, BMP6의 발현)

  • Lee, Hyun-Suk;Heo, Hyun-A;Pyo, Sung-Woon;Lee, Won
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.6
    • /
    • pp.467-473
    • /
    • 2007
  • The most important factor for successful implantation is osseointegration between the implant and bone. The expression of bone morphogenetic proteins (BMPs) inducing bone formation would differ after maxillary sinus elevation. And within the same graft material. the expression of BMPs would change with time after graft. The aim of this study was to compare the relative expressions of BMP4 and BMP6 using real-time RT-PCR when maxillary sinus elevation was performed using deproteinated bovine bone powder (DBBP) as the graft material or absorbable gelatin sponge (AGS) as the filler without any graft material. Fifteen rabbits, each weighing between 3.0 to 3.5 Kg, were divided randomly into 5 groups of 3 animals each based on their time of sacrifice 0, 3, 5, 7 and 9 days). After exposure of the maxillary sinus bilaterally, bone graft was performed in the right maxillary sinus using DBBP ($BBP^{(R)}$ Oct Inc., Cheonan, Korea) and only AGS ($Gelfoam^{(R)}$ Pharmacia & Upjohn Company, Kalamazoo, MI, U.S.A) was placed into the left without any graft material. Each group of rabbits was sacrificed at 1, 3, 5, 7, or 9 days after operation and all specimens were harvested. And the following results were obtained using real-time RT-PCR from isolated total RNA of the samples. 1. The expression of BMP4 increased at postoperative 1 and 3 days in both DBBP group and AGS group. In AGS group. it decreased at postoperative 5 days. increased again at postoperative 7 days, and decreased at postoperative 9 days. In DBBP group, it increased until postoperative 7 days and decreased at postoperative 9 days. Although the expression of BMP4 was higher in DBBP group compared with AGS group, it was not statistically significant (p>0.05). 2. The expression of BMP6 increased at postoperative 1 and 3 days in both DBBP group and AGS group. In AGS group, it decreased at postoperative 5 days, increased again at postoperative 7 days, and decreased at postoperative 9 days. In DBBP group, it increased until postoperative 7 days and decreased at postoperative 9 days. Although the expression of BMP6 was higher in AGS group compared with DBBP group, it was not statistically significant (p>0.05). 3. There was no statistically significant difference in BMP expression in both groups during same period of time. It' s probably because DBBP and AGS both functioned as a space retainer so that the BMP expression in blood clot seemed to be similar. 4. Thus, DBBP would not offer many benefits for early bone regeneration compared with AGS. The expression of BMP in early bone formation seems to be more influenced by physical carrier rather than the graft type.

A Study on the Stress Distribution of Tooth/Implant Connected with Konus Telescope Denture Using 3-Dimensional Finite Element Method (이중관으로 연결된 자연치와 임플랜트의 악골 내응력분포에 관한 3차원 유한요소분석)

  • Lee, Su-Ok;Choi, Dae-Gyun;Kwon, Kung-Rock;Woo, Yi-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.4
    • /
    • pp.381-395
    • /
    • 2008
  • Purpoose: For decades dental implants have been used widely in the field of prosthetic dentistry. However there is confusion when establishing treatment plans in cases where some teeth are remained but an insufficient number of implants can be used due to limited anatomical status and ecomomical problems. Many clinicians have tried to connect natural teeth and implants, and it still has controversy. But, there have been few studies on mechanical analysis of connecting natural teeth and implants with konus telescopic removable partial dentures. The purpose of this study was to analyze the stress distribution of prosthesis, abutment and alveolar bone when teeth and implants were connected with the konus telescopic denture, by means of 3-dimensional finite element analysis. Material and methods: The assumption of this study was that there were 2 mandibular canine (11 mm in length, 4 mm in diameter) and 2 implants(10 mm in length, 4 mm in diameter) which are located in the second premolar region. The mandible, teeth, implants, abutments, and connectors are modeled, and analyzed with the commercial software, ANSYS Version 8.1(Swanson, Inc., USA). The control group used implants instead of natural teeth. 21038 elements, 23544 nodes were used in experimental group and 107595 elements, 21963 nodes were used in control group, Stress distribution was evaluated under 150 N vertical load on 3 experimental conditions - between teeth and implants (Load case 1), posterior to implants (Load case 2), between natural teeth (Load case 3). Results: 1. In all load cases, higher von mises stress value was observed in the experimental group. 2. Maximum von miss stress observed in all load cases and all locations were as follows ; a. 929.44 Mpa in the experimental group, 640.044 Mpa in the control group in outer crown and connector - The experimental group showed 1.45 times high value compared with the control group. b. 145,051 Mpa in the experimental group, 142.338 Mpa in the control group in abutment - The experimental group showed 1.02times high value compared with the control group. c. 32.489 Mpa in the experimental group, 25.765 Mpa in the control group in alveolar bone - The experimental group showed 1.26times higher value compared with the control group. 3. All maximum von mises stress was observed in load case 2, and maxim von mises stress in alveolar bone was 32.489 Mpa at which implant failure cannot occur. 4. If maximum von mises stress is compared between two groups, the value of the experimental group is 1.02 times higher than the control group in abutment, 1.26 times higher than the control group in alveolar bone. Conclusion: If natural teeth and implants are connected with the konus telescopic denture, maximum stress will be similar in abutment, 1.26 times higher in alveolar bone than the control group. With this result, there may be possible to make to avoid konus telescopic dentures where natural teeth and implants exist together.

Factors influencing the axes of anterior teeth during SWA on masse sliding retraction with orthodontic mini-implant anchorage: a finite element study (교정용 미니 임플랜트 고정원과 SWA on masse sliding retraction 시 전치부 치축 조절 요인에 관한 유한요소해석)

  • Jeong, Hye-Sim;Moon, Yoon-Shik;Cho, Young-Soo;Lim, Seung-Min;Sung, Sang-Jin
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.339-348
    • /
    • 2006
  • Objective: With development of the skeletal anchorage system, orthodontic mini-implant (OMI) assisted on masse sliding retraction has become part of general orthodontic treatment. But compared to the emphasis on successful anchorage preparation, the control of anterior teeth axis has not been emphasized enough. Methods: A 3-D finite element Base model of maxillary dental arch and a Lingual tipping model with lingually inclined anterior teeth were constructed. To evaluate factors influencing the axis of anterior teeth when OMI was used as anchorage, models were simulated with 2 mm or 5 mm retraction hooks and/or by the addition of 4 mm of compensating curve (CC) on the main archwire. The stress distribution on the roots and a 25000 times enlarged axis graph were evaluated. Results: Intrusive component of retraction force directed postero-superiorly from the 2 mm height hook did not reduce the lingual tipping of anterior teeth. When hook height was increased to 5 mm, lateral incisor showed crown-labial and root-lingual torque and uncontrolled tipping of the canine was increased.4 mm of CC added to the main archwire also induced crown-labial and root-lingual torque of the lateral incisor but uncontrolled tipping of the canine was decreased. Lingual tipping model showed very similar results compared with the Base model. Conclusion: The results of this study showed that height of the hook and compensating curve on the main archwire can influence the axis of anterior teeth. These data can be used as guidelines for clinical application.

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

Histomorphometric Study of Sinus Bone Graft using Various Graft Material (다양한 골이식재료를 이용한 상악동 골이식 4개월 후 조직형태계측학적 평가)

  • Lee, Ji-Young;Kim, Young-Kyun;Kim, Su-Gwan;Lim, Sung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.141-147
    • /
    • 2011
  • The aim of this study was to evaluate histomorphometrically and compare the efficiency of various bone graft material and autogenous tooth bone graft material which were used in sinus bone graft procedure. Subjects were the 24 patients who had treated with sinus bone graft using lateral approach from October 2007 to September 2009 at SNUBH. The average age was $52.51{\pm}11.86$ years. All cases was taken after 4month of procedure and divided into 3 groups according to bone graft material. Group 1: autogenous tooth bone graft material, Group 2: OrthoblastII(integra lifescience corp. Irvine, US)+Biocera(Osscotec, seoul, korea), group 3: DBX(Synthes, USA)+BioOss(Geistlich Pharm AG, Wolhusen, Switzerland). Total 37 implant placement area were included and evaluated(7 in group 1, 10 in group 2, 20 in group 3). Evaluation of new bone formation, ratio of woven bone to lamellar bone, ratio of new bone to graft material were performed on each tissue section. Kruskal-Wallis test was used for statistical analysis(SPSS Ver. 12.0, USA). New bone formation were $52.5{\pm}10.7%$ in group 1, $52.0{\pm}23.4%$ in group 2, $51.0{\pm}18.3%$ in group 3. There were no statistical significant differences between each groups. Ratio of woven bone to lamella bone were $82.8{\pm}15.3%$ in group 1, $36.7{\pm}59.3%$ in group 2, $31.0{\pm} 51.2%$ in group 3. Ratio of new bone to graft material were $81.3{\pm}10.4%$ in group 1, $72.5{\pm}28.8%$ in group 2, $80.3{\pm}24.0%$ in group 3. After 4 month of healing period, all group showed favorable new bone formation and around graft material and implant. Within limitation of our study, it is suggested that autogenous tooth bone graft material might be used as novel bone graft material for sinus bone graft.

Occlusal rehabilitation of post-traumatic malocclusion patient after reduction of panfacial fracture, using selective occlusal adjustment and implant prostheses on centric relation: a case report (다발성 안면 골절의 정복 후 발생한 부정교합 상태의 환자를 중심위에서 선택적 교합 조정 및 임플란트 보철수복으로 교합관계를 회복시킨 증례)

  • Dae-Kyun Kim;So-Young Park;Jung-Jin Lee;Yeon-Hee Park;Kyoung-A Kim;Jae-Min Seo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.204-213
    • /
    • 2023
  • Invasive or non-invasive reduction of fractures could be conducted as treatments of traumatic maxillofacial bone fractures. But when suboptimal reduction or malunion of maxillofacial bone fracture occurs, malocclusion could occur as a result of the lost relationship of the mandible and midface. This malocclusion is called post-traumatic malocclusion and orthognathic surgery, orthodontic treatment, selective grinding and prosthetic reconstruction are suggested as treatments for post-traumatic malocclusion after securement of stable TMJ. Stable TMJ is essential for occlusal rehabilitation to prevent occlusal change and relapse of malocclusion. Centric relation and adapted centric posture are suggested as start points of occlusal rehabilitation because they are most stable TMJ position. This case report presents a case in which post-traumatic malocclusion occurred after reduction of panfacial fracture. To rehabilitate full mouth occlusion, selective grinding and prosthetic reconstruction of implant supported fixed prostheses were conducted in centric relation and showed satisfying results in functional and occlusal aspects.

Periodontal prosthesis on medically compromised patient with few remaining teeth: hybrid telescopic double crown with friction pin method (의과적 문제가 있고 소수 잔존치를 가지는 환자에서의 치주보철 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.359-365
    • /
    • 2014
  • Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth have been reported in several journals. A double crown removable partial denture can be an alternative treatment for the patients with a poor periodontal condition of remaining teeth. Since a double crown removable partial denture can be applied without the risk of surgical operation to the medically compromised patients with a poor periodontal condition which is inadequate for dental implants, it has psychological and economical advantages. In this case, there were sufficient remaining teeth to be restored with fixed prostheses in maxilla, while there were a few remaining teeth with a very poor periodontal condition so that it was almost impossible to restore with a clasp removable partial denture using these remaining teeth in mandible. In addition, the patient had the medical history of surgical operation due to osteomyelitis in the mandibular anterior areas a year ago, thus difficult to conduct an implant placement. The main objective of this report is to introduce our case because a double crown partial denture using a few mandibular remaining teeth showed satisfactory results in functional and esthetical aspects during more than two years follow-up period in this unfavorable condition.

THE CLINICAL STUDY OF MAXILLARY SINUS SEPTA USED IN PANORAMA, CT (Panorama, CT를 이용한 상악동내 중격의 임상적 연구)

  • Jung, Jin-Won;Song, Kyoung-Ho;Lee, Seul-Ki;Kim, Jwa-Young;Yang, Byoung-Eun;Kim, Sung-Gon;Song, Sang-Hun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.319-324
    • /
    • 2008
  • Purpose: The aim of this study was to examine the incidence, location and morphology of antral septa using radiographic exam.(Panorama, CT) in the dentate/non-atrophic and edentulous/atrophic maxillary segments. Material & methods: 232 sinuses were subdivided into two groups(group1 : 175 sinuses were classified as complete & partial dentate maxillary segments, group2 : 57 sinuses were classified as complete edentulous maxillary segments) and were investigated for the incidence, location and morphology of maxillary sinus septa. Results: A total of 80 septa were observed in 232 maxillary sinuses, which corresponded to 30.65% of the sinuses(71 of 232). 67.5% of the total septa was observed in the complete & partial dentate groups, but 32.5% of the total septa was observed in the complete edentulous group. Upon analysis of the anatomical location of the septa, it was seen that 14 septa(17.5%) were located in the P1 area, 15 septa(18.7%) were located in the P2 area, 19 septa(23.8%) were located in the M1 area and 32 septa(40%) were located in the M2 area & dista area of M2. we found 45 septa in the apical lesion of teeth, Group 1. However the remaining 9 septa were found in the edentulous area. Conclusion: CT is a better method than panoramic radiography for detecting the presence of the maxillary sinus septa. Maxillary sinus septa are more commonly detected in complete edentulous maxillary segments than in complete & partial dentate maxillary segments. Also maxillary sinus septa are more commonly detected posteriorly than anteriorly.

Evaluation of Insertion of torque and Pull-out strength of mini-screws according to different thickness of artificial cortical bone (다양한 교정용 미니 스크류의 인공 피질골 두께에 따른 삽입 토오크와 Pull-out 강도 비교)

  • Song, Young-Youn;Cha, Jung-Yul;Hwang, Chung-Ju
    • The korean journal of orthodontics
    • /
    • v.37 no.1 s.120
    • /
    • pp.5-15
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the mechanical performance of mini-screws during insertion into artificial bone with use of the driving torque tester (Biomaterials Korea, Seoul, Korea), as well as testing of Pull-out Strength (POS). Methods: Experimental bone blocks with different cortical bone thickness were used as specimens. Three modules of commercially available drill-free type mini-screws (Type A; pure cylindrical type, Biomaterials Korea, Seoul, Korea, Type B; partially cylindrical type, Jeil Medical, Seoul, Korea, Type C; combination type of cylindrical and tapered portions, Ortholution, Seoul, Korea), were used. Results: Difference in the cortical bone thickness had little effect on the maximum insertion torque (MIT) in Type A mini-screws. But in Type B and C, MIT increased as the cortical bone thickness Increased. MIT of Type C was highest in all situations, then Type B and Type A in order. Type C showed lower POS than Type A or B in all situations. There were statistically significant correlations between cortical bone thickness and MIT, and POS for each type of the mini-screws. Conclusion: Since different screw designs showed different insertion torques with increases in cortical bone thickness, the best suitable screw design should be selected according to the different cortical thicknesses at the implant sites.