Abstract
Purpoose: For decades dental implants have been used widely in the field of prosthetic dentistry. However there is confusion when establishing treatment plans in cases where some teeth are remained but an insufficient number of implants can be used due to limited anatomical status and ecomomical problems. Many clinicians have tried to connect natural teeth and implants, and it still has controversy. But, there have been few studies on mechanical analysis of connecting natural teeth and implants with konus telescopic removable partial dentures. The purpose of this study was to analyze the stress distribution of prosthesis, abutment and alveolar bone when teeth and implants were connected with the konus telescopic denture, by means of 3-dimensional finite element analysis. Material and methods: The assumption of this study was that there were 2 mandibular canine (11 mm in length, 4 mm in diameter) and 2 implants(10 mm in length, 4 mm in diameter) which are located in the second premolar region. The mandible, teeth, implants, abutments, and connectors are modeled, and analyzed with the commercial software, ANSYS Version 8.1(Swanson, Inc., USA). The control group used implants instead of natural teeth. 21038 elements, 23544 nodes were used in experimental group and 107595 elements, 21963 nodes were used in control group, Stress distribution was evaluated under 150 N vertical load on 3 experimental conditions - between teeth and implants (Load case 1), posterior to implants (Load case 2), between natural teeth (Load case 3). Results: 1. In all load cases, higher von mises stress value was observed in the experimental group. 2. Maximum von miss stress observed in all load cases and all locations were as follows ; a. 929.44 Mpa in the experimental group, 640.044 Mpa in the control group in outer crown and connector - The experimental group showed 1.45 times high value compared with the control group. b. 145,051 Mpa in the experimental group, 142.338 Mpa in the control group in abutment - The experimental group showed 1.02times high value compared with the control group. c. 32.489 Mpa in the experimental group, 25.765 Mpa in the control group in alveolar bone - The experimental group showed 1.26times higher value compared with the control group. 3. All maximum von mises stress was observed in load case 2, and maxim von mises stress in alveolar bone was 32.489 Mpa at which implant failure cannot occur. 4. If maximum von mises stress is compared between two groups, the value of the experimental group is 1.02 times higher than the control group in abutment, 1.26 times higher than the control group in alveolar bone. Conclusion: If natural teeth and implants are connected with the konus telescopic denture, maximum stress will be similar in abutment, 1.26 times higher in alveolar bone than the control group. With this result, there may be possible to make to avoid konus telescopic dentures where natural teeth and implants exist together.
Keywords
Three dimensional finite element analysis; Implant; Natural teeth; Konus;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Lim JK, Accuracy Estimation and Control Methods of Finite Element Solutions. J KSME 1994;34:502   과학기술학회마을
2 Farah JW, Craig RG, Meroueh KA. Finite element analysis of three-and four-unit bridges. J Oral Rehabil 1989;16:603-11   DOI
3 Lavernia CJ, Cook SD, Weinstein AM, Klawitter JJ. An analysis of stresses in a dental implant system. J Biomech 1981;14:555-60   DOI   ScienceOn
4 Glickman I. Clinical periodontology, Philadelphia, 1972, W,B. Saunders Company, pp29, 329
5 Phillips RW. Science of dental materials 8thed. Philadelphia, W.B. Saunders Co 1982
6 Rieger MR, Adams WK, Kinzel GL. A finite element survey of eleven endosseous implants. J Prosthet Dent 1990;63:457-65   DOI   ScienceOn
7 Besimo C, Graber G. A new concept of overdentures with telescope crowns on osseointegrated implants. Int J Periodontics Restorative Dent 1994;14:486-95
8 Naert I, Quirynen M, van Steenberghe D, Darius P. A sixyear prosthodontic study of 509 consecutively inserted implants for treatment of partial edentulism. J Prosthet Dent 1992;67:236-45   DOI   ScienceOn
9 Nishimura RD, Ochiai KT, Caputo AA, Jeong CM. Photoelastic stress analysis of load transfer to implants and natural teeth comparing rigid and semirigid connectors. J Prosthet Dent 1999;81:696-703   DOI   ScienceOn
10 McGlumphy EA, Campagni WV, Peterson LJ. A comparison of the stress transfer characteristics of a dental implant with a regid or a resilient internal element. J Prosthet Dent 1989;62:586-93   DOI   ScienceOn
11 Yokoyama S, Wakabayashi N, Shiota M, Ohyama T. Stress analysis in edentulous mandibular bone supporting implant-retained 1-piece or multiple superstructures. Int J Oral Maxillofac Implants 2005;20:578-83
12 Schnitman PA, Rubenstein JE, Who¨rle PS, DaSilva JD, Koch GG. Periodontal considerations of implants for partial edentulism. J Dent Educ 1988;52:725-36   PUBMED
13 Thomas JR Hughes. The Finite Element Method: linear static and dynamic finite element analysis. Prentice-Hall Inc, 1987
14 Takahashi N, Kitagami T, Komori T. Analysis of stress on a fixed partial denture with a blade-vent implant abutment. J Prosthet Dent 1978;40:186-91   DOI   ScienceOn
15 Ross SE, Schultz IM, Ross KE. An introductory therapeutic modality for restoring implants and natural teeth using conus crowns: a 5-year case report. Int J Periodontics Restorative Dent 1999;19:569-77   PUBMED
16 Jemt T, Lekholm U. Implant treatment in edentulous maxillae: a 5-year follow-up report on on patients with different degrees of jaw resorption. Int J Oral Maxillofac Implants 1995;10:303-11
17 Karlheinz Korber 저, 우이형 역: 원추관-합리적인 텔레스코프 시스템을 위한 임상이론과 기공과정의 입문. 신흥인터네셔날 1998; p70
18 Lundgren D, Falk H, Laurell L. Prerequisites for 'stiff' connection between osseointegrated implants and natural teeth. J Dent Res 1988;67:347
19 Lin CL, Chang SH, Wang JC, Chang WJ. Mechanical interactions of an implant/tooth-supported system under different periodontal supports and number of splinted teeth with rigid and non-rigid connections. J Dent 2006;34:682- 91   DOI   ScienceOn
20 Choi SH, Chung CH. Finite element analysis of stresses and deflections induced by fixed partial denture using en-dosteal implant. J Kor Acad Prosthodont 1991;29:233
21 Longoni S, Apruzzese D, Careddu G, Sartori M, Davide R. New telescopic crown protocol for partially edentulous patients: report of 32 cases. Int J Periodontics Restorative Dent 2005;25:475-81   PUBMED
22 Mathews MF, Breeding LC, Dixon DL, Aquilino SA. The effect of connector design on cement retention in an implant and natural tooth-supported fixed partial denture. J Prosthet Dent 1991;65:822-7   DOI   ScienceOn
23 Fenton A, Jamshaid D, Davis D. Osseointegrated fixture mobility(abstract). J Dent Res 1987;66:114
24 Akagawa Y, Sato Y, Teixeira ER, Shindoi N, Wadamoto M. A mimic osseointegrated implant model for three-dimensional finite element analysis. J Oral Rehabil 2003;30:41-5   DOI   ScienceOn
25 Astrand P, Borg K, Gunne J, Olsson M. Combination of natural teeth and osseointegrated implants as prosthesis abutments: a 2-year longitudinal study. Int J Oral Maxillofac Implants 1991;6:305-12   PUBMED
26 Naert IE, Ducky JA, Honsy MM, van Steenberghe D. Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients. Part I: An up to 15-years radiographic evaluation. Clin Oral Implants Res 2001;12:237-44   DOI   ScienceOn
27 Morrow RM, Feldmann EE, Rudd KD, Trovillion HM. Tooth-supported complete dentures: an approach to preventive prosthodontics. J Prosthet Dent 1969;21:513-22   DOI   ScienceOn
28 Pesun IJ. Intrusion of teeth in the combination implant-tonatural- tooth fixed partial denture: a review of the theories. J Prosthodont 1997;6:268-77   DOI   ScienceOn
29 Menicucci G, Lorenzetti M, Pera P, Preti G. Mandibular implant-retained overdenture: finite element analysis of two anchorage systems. Int J Oral Maxillofac Implants 1998;13:369-76
30 Ollsson M, Gunne J, Astrand P, Borg K. Bridges supported by free-standing implants versus bridges supported by tooth and implant. A five-year prospective study. Clin Oral Implants Res 1995;6:114-21   DOI   ScienceOn
31 Chapman RJ. Principles of occlusion for implant prostheses: guidelines for position, timing, and force of occlusal contacts. Quintessence Int 1989;20:473-80   PUBMED
32 Smith DE. Review of endosseous implants for partially edentulous patients. Int J Prosthodont 1990;3:12-9   PUBMED
33 Skalak R. Biomechanical coonsiderations in osseointegration prostheses. J Prosthet Dent 1983;49:843-8   DOI   ScienceOn
34 Gunne J, Astrand P, Ahlen K, Borg K, Olsson M. Implants in partial edentulous patients: a longitudinal study of bridges supported by natural teeth. Clin Oral Implants Res 1992;3:49-56   DOI   ScienceOn
35 Richter EJ, Spiekermann H, Jovanovic SA. Tooth-to implant fixed prostheses : Biomechanics based on in vitro and in vivo measurement. In : Laney W R, and Tolman DE, eds, Tissue integration in oral, orthopedic & maxillofacial reconstruction. Quintessence Publ. Co, Chicago, 1992
36 Ericsson I. The combined effect of plaque and physical stress on periodontal tissues. J Clin Periodontol 1986;13:918-22   DOI
37 Naert IE, Duyck JA, Hosny MM, Quirynen M, van Steenberghe D. Freestanding and tooth-implant connected prostheses in the treatment of partially edentulous patients Part II: An up to 15-years radiographic evaluation. Clin Oral Implants Res 2001;12:245-51   DOI   ScienceOn
38 Kay HB. Free-standing versus implant-tooth-interconnected restorations: understanding the prosthodontic perspective. Int J Periodontics Restorative Dent 1993;13:47-69
39 ANSYS 'ANSYS Workbench Education Manual Release 8.0'
40 Koak JY, Kim KN, Chang IT, Heo SJ. A study on the stress distribution of abutment teeth and residual ridge area between telescopic and clasp type RPD by fem method. J Kor Acad Prosthodont 1999;37:104-26   과학기술학회마을
41 Zienkiewicz OC, Taylor RL. The Finite Element Method. McGraw Hill International Edition, 1989
42 Ralph WJ. The effects of dental treatment on biting force. J Prosthet Dent 1979;41:143-5   DOI   ScienceOn
43 Adell R, Lekholm U, Rockler B, Branemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10;387-416   DOI
44 Gunne J, Jemt T, Linden B. Implant treatment in parially edentulous patients: A report on prostheses after 3 years. Int J Prosthodont 1994;7:143-8   PUBMED
45 Hug S, Mantokoudis D, Mericske-Stern R. Clinical evaluation of 3 overdenture concept with roots and implants. Int J Prosthodont 2006;19:236-43   PUBMED