• Title/Summary/Keyword: Dental Image Processing

Search Result 81, Processing Time 0.021 seconds

Cell Image Processing Methods for Automatic Cell Pattern Recognition and Morphological Analysis of Mesenchymal Stem Cells - An Algorithm for Cell Classification and Adaptive Brightness Correction -

  • Lim, Kitaek;Park, Soo Hyun;Kim, Jangho;SeonWoo, Hoon;Choung, Pill-Hoon;Chung, Jong Hoon
    • Journal of Biosystems Engineering
    • /
    • v.38 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • Purpose: The present study aimed at image processing methods for automatic cell pattern recognition and morphological analysis for tissue engineering applications. The primary aim was to ascertain the novel algorithm of adaptive brightness correction from microscopic images for use as a potential image analysis. Methods: General microscopic image of cells has a minor problem which the central area is brighter than edge-area because of the light source. This may affect serious problems to threshold process for cell-number counting or cell pattern recognition. In order to compensate the problem, we processed to find the central point of brightness and give less weight-value as the distance to centroid. Results: The results presented that microscopic images through the brightness correction were performed clearer than those without brightness compensation. And the classification of mixed cells was performed as well, which is expected to be completed with pattern recognition later. Beside each detection ratio of hBMSCs and HeLa cells was 95% and 92%, respectively. Conclusions: Using this novel algorithm of adaptive brightness correction could control the easier approach to cell pattern recognition and counting cell numbers.

Acquisition and Processing of 3D Data (3차원 데이터의 획득 및 가공)

  • Kim A.H.;Kim Y.S.;Bae C.;Kang W.C.;Kim Y.D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.286-290
    • /
    • 2003
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Two camera method keeps accuracy more than double than mechanical method. In this paper, we describe the processes surface data of teeth for automatic processing, transformation that changes to coping data of possible numeric data form and processed inlay teeth. As the result of the Inlay manufacture, which can process with high resolution, therefore we construct the automatic processing system that depends on manual

  • PDF

3D Processing System of Tooth shape (치형 3차원 가공시스템)

  • Kim, Young-Su;Kim, Nam-Oh;Min, Wan-Ki;Shin, Suck-Doo;Kang, Won-Can;Kim, Young-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.120-123
    • /
    • 2003
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Two camera method keeps accuracy more than double than mechanical method. In this paper, we describe the processes surface data of teeth for automatic processing, transformation that changes to coping data of possible numeric data form, and processed inlay teeth. As the result of the Inlay manufacture, which can process with high resolution, therefore we construct the automatic processing system that depends on manual.

  • PDF

Assessment of Internal Fitness on Resin Crown Fabricated by Digital Light Processing 3D Printer

  • Kang, Wol;Kim, Min-Su;Kim, Won-Gi
    • Journal of dental hygiene science
    • /
    • v.19 no.4
    • /
    • pp.238-244
    • /
    • 2019
  • Background: Recently, three-dimensional (3D) printing has been hailed as a disruptive technology in dentistry. Among 3D printers, a digital light processing (DLP) 3D printer has certain advantages, such as high precision and relatively low cost. Therefore, the latest trend in resin crown manufacturing is the use of DLP 3D printers. However, studies on the internal fitness of such resin crowns are insufficient. The recently introduced 3D evaluation method makes it possible to visually evaluate the error of the desired area. The purpose of this study is to evaluate the internal fitness of resin crowns fabricated a by DLP 3D printer using the 3D evaluation method. Methods: The working model was chosen as the maxillary molar implant model. A total of 20 resin crowns were manufactured by dividing these into two groups. One group was manufactured by subtractive manufacturing system (PMMA), while the other group was manufactured by additive manufacturing system, which uses a DLP 3D printer. Resin crowns data were measured using a 3D evaluation program. Internal fitness was calculated by root mean square (RMS). The RMS was calculated using the Geomagic Verify software, and the mean and standard deviation (SD) were measured. For statistical analysis, IBM SPSS Statistics for Windows ver. 22.0 (IBM Corp., USA) was used. Then, independent t-test was performed between the two groups. Results: The mean±SD of the RMS were 41.51±1.51 and 43.09±2.32 for PMMA and DLP, respectively. There was no statistically significant difference between PMMA and DLP. Conclusion: Evaluation of internal fitness of the resin crown made using a DLP 3D printer and subtractive manufacturing system showed no statistically significant differences, and clinically acceptable results were obtained.

A Comparative Study on Rate of Error with Bisecting Angle Technique and Paralleling Technique (등각촬영법과 평행촬영법에서의 실책 비교 연구)

  • Lee, Kyeong-Hee;Park, Il-Soon;Jung, Jung-Ock
    • Journal of dental hygiene science
    • /
    • v.11 no.3
    • /
    • pp.155-161
    • /
    • 2011
  • The purpose of this study was to obtain data necessary for guiding students in the future by grasping which rate of error is made how much depending on a shooting technique in the filming of periapical radiograph. 14,402 films, which were instructed targeting students for the Department of Dental Hygiene at D Health College and S Health College, were analyzed. The following results were obtained by conducting questionnaire survey targeting 263 students who completed the shooting practice lesson of bisecting angle technique and paralleling technique. 1. In case of having shot with bisecting angle technique, the ratio of error was the highest in both maxillary and mandibular first molar. 2. In case of having shot with paralleling technique, the ratio of error was the highest in the maxillary bicuspid and the mandibular first molar. 3. As for ratio of error in light of a shooting technique, both bisecting angle technique and paralleling technique were indicated to be the highest in inaccuracy of film position. The bisecting angle technique was indicated to have the higher ratio of error compared to the paralleling technique. 4. As for ratio of error in light of the processing technique, both bisecting angle technique and paralleling technique were indicated to be the highest in dark image and light image. The bisecting angle technique was indicated to have the higher ratio of error compared to the paralleling technique. 5. Students were indicated to feel it to be most difficult for grasping the processing level in the film-developing process. As the above results, to reduce ratio of error given the periapical radiography, a method of reducing ratio of error given the periapical radiography is considered to be what correctly understands the morphological and anatomical structure inside the mouth and what acquires the shooting technique by filming several times with having enough time.

A posteriori registration and subtraction of periapical radiographs for the evaluation of external apical root resorption after orthodontic treatment

  • Kreich, Eliane Maria;Chibinski, Ana Claudia;Coelho, Ulisses;Wambier, Leticia Stadler;Zedebski, Rosario de Arruda Moura;de Moraes, Mari Eli Leonelli;de Moraes, Luiz Cesar
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.17-24
    • /
    • 2016
  • Purposes: This study employed a posteriori registration and subtraction of radiographic images to quantify the apical root resorption in maxillary permanent central incisors after orthodontic treatment, and assessed whether the external apical root resorption (EARR) was related to a range of parameters involved in the treatment. Materials and Methods: A sample of 79 patients (mean age, $13.5{\pm}2.2years$) with no history of trauma or endodontic treatment of the maxillary permanent central incisors was selected. Periapical radiographs taken before and after orthodontic treatment were digitized and imported to the Regeemy software. Based on an analysis of the post-treatment radiographs, the length of the incisors was measured using Image J software. The mean EARR was described in pixels and relative root resorption (%). The patient's age and gender, tooth extraction, use of elastics, and treatment duration were evaluated to identify possible correlations with EARR. Results: The mean EARR observed was $15.44{\pm}12.1pixels$ (5.1% resorption). No differences in the mean EARR were observed according to patient characteristics (gender, age) or treatment parameters (use of elastics, treatment duration). The only parameter that influenced the mean EARR of a patient was the need for tooth extraction. Conclusion: A posteriori registration and subtraction of periapical radiographs was a suitable method to quantify EARR after orthodontic treatment, and the need for tooth extraction increased the extent of root resorption after orthodontic treatment.

A comparison of subtracted images from dental subtraction programs (디지털공제프로그램간의 디지털공제영상 비교)

  • Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

  • Kang, Sung-Won;Lee, Woo-Jin;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.7-13
    • /
    • 2015
  • Purpose: We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). Materials and Methods: The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. Results: VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). Conclusion: It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

Quantitative evaluation of midpalatal suture maturation via fractal analysis

  • Kwak, Kyoung Ho;Kim, Seong Sik;Kim, Yong-Il;Kim, Yong-Deok
    • The korean journal of orthodontics
    • /
    • v.46 no.5
    • /
    • pp.323-330
    • /
    • 2016
  • Objective: The purpose of this study was to determine whether the results of fractal analysis can be used as criteria for midpalatal suture maturation evaluation. Methods: The study included 131 subjects aged over 18 years of age (range 18.1-53.4 years) who underwent cone-beam computed tomography. Skeletonized images of the midpalatal suture were obtained via image processing software and used to calculate fractal dimensions. Correlations between maturation stage and fractal dimensions were calculated using Spearman's correlation coefficient. Optimal fractal dimension cut-off values were determined using a receiver operating characteristic curve. Results: The distribution of maturation stages of the midpalatal suture according to the cervical vertebrae maturation index was highly variable, and there was a strong negative correlation between maturation stage and fractal dimension (-0.623, p < 0.001). Fractal dimension was a statistically significant indicator of dichotomous results with regard to maturation stage (area under curve = 0.794, p < 0.001). A test in which fractal dimension was used to predict the resulting variable that splits maturation stages into ABC and D or E yielded an optimal fractal dimension cut-off value of 1.0235. Conclusions: There was a strong negative correlation between fractal dimension and midpalatal suture maturation. Fractal analysis is an objective quantitative method, and therefore we suggest that it may be useful for the evaluation of midpalatal suture maturation.

CHROMIUM INTENSIFICATION OF A PROCESSED DENTAL RADIOGRAPH (현상처리된 치과용 방사선필름의 크롬 증강효과에 대하여)

  • Park Myoung-Seon;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.211-217
    • /
    • 1990
  • This study was undertaken to determine (1) the usefulness of chromium intensifier to improve the dignostic quality of light radiograph; (2) the effect of chromium intensifier on density, contrast; and (3) the effect of various chemical concentrations on density. The following results obtained: 1. CHROMIUM INTENSIFIER is useful for intensifying and improving the diagnostic quality of a light dental radiograph. 2. The degree of intensification can be controlled by varying bleaching time, repeating the processing, varying the proportions of the potassium bicarbonate and hydrochloric acid solutions. 3. The image produced is black and permanent. 4. The intensifier increases density and contrast.

  • PDF