• Title/Summary/Keyword: Dental Image

Search Result 685, Processing Time 0.033 seconds

Radiopacity of contemporary luting cements using conventional and digital radiography

  • An, Seo-Young;An, Chang-Hyeon;Choi, Karp-Sik;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.97-101
    • /
    • 2018
  • Purpose: This study evaluated the radiopacity of contemporary luting cements using conventional and digital radiography. Materials and Methods: Disc specimens (N=24, n=6 per group, ø$7mm{\times}1mm$) were prepared using 4 resin-based luting cements (Duolink, Multilink N, Panavia F 2.0, and U-cem). The specimens were radiographed using films, a complementary metal oxide semiconductor (CMOS) sensor, and a photostimulable phosphor plate (PSP) with a 10-step aluminum step wedge (1 mm incremental steps) and a 1-mm-thick tooth cut. The settings were 70 kVp, 4 mA, and 30 cm, with an exposure time of 0.2 s for the films and 0.1 s for the CMOS sensor and PSP. The films were scanned using a scanner. The radiopacity of the luting cements and tooth was measured using a densitometer for the film and NIH ImageJ software for the images obtained from the CMOS sensor, PSP, and scanned films. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests. Results: Multilink (3.44-4.33) showed the highest radiopacity, followed by U-cem (1.81-2.88), Panavia F 2.0 (1.51-2.69), and Duolink (1.48-2.59). The $R^2$ values of the optical density of the aluminum step wedge were 0.9923 for the films, 0.9989 for the PSP, 0.9986 for the scanned films, and 0.9266 for the CMOS sensor in the linear regression models. Conclusion: The radiopacities of the luting materials were greater than those of aluminum or dentin at the same thickness. PSP is recommended as a detector for radiopacity measurements because of its accuracy and convenience.

MEASUREMENT OF MAXILLARY SINUS VOLUME FOR THE PLACEMENT OF GRAFT MATERIAL - A CASE CONTROL STUDY USING CT IMAGE (상악동 골이식술을 위한 이식재의 부피 측정 - CT를 이용한 환자 대조군 연구)

  • Kim, Hyung-Wook;Lee, Seul-Ki;Chung, Jae-An;Shin, Jin-Eob;Um, Yun-Sub;Kim, Ki-Young;Kim, Jong-Sik;Song, Yun-Jung;Hong, Soon-Min;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.5
    • /
    • pp.511-517
    • /
    • 2007
  • Purpose: The aim of this study is to determine whether a difference in the amount of bone graft material is needed between edentulous patients and dentulous patients and to calculate the amount of augmentation for a sinus lift procedure. Methods: 19 patients(20 sinuses) were included to measure maxillary sinus volume. Facial CT scanning was performed using MX 8000 IDT CT devices(Philips, USA). And it was used for IDLvm(The IDL Virtual Machine) 6.0, CT Volume Analyzer Ver 2.3 program to measure maxillary sinus volumes Results: At edentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.56{\pm}0.13cm^3$(5mm height), $2.35{\pm}0.57cm^3$(10mm height), $4.85{\pm}1.10cm^3$(15mm height). At dentulous patients, volumes(mean${\pm}SD$) of the inferior portion of the sinuses were $0.41{\pm}0.18cm^3$(5mm height), $1.76{\pm}0.42cm^3$(10mm height), $3.80{\pm}0.84cm^3$ (15mm height). A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume.(p=0.027, p=0.018, p=0.044) Conclusions: A significant correlation was found between augmentation height(5mm, 10mm, 15mm) and the calculated sinus volume. Detailed preoperative knowledge of sinus lift augmentation volume is helpful in determining the appropriate amount of the bone graft material.

Introduction of Dental X-ray Imaging with New Concept - intra Oral x-ray Tube (신개념 치과용 X-선 영상장치 소개 - 강내형 X-선 튜브)

  • Cho, Sung-Ho;Kim, Dong-Young;Baek, Kwang-Woo;Lee, Re-Na
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.94-101
    • /
    • 2011
  • Various kinds of medical imaging devices have been studied to develop periapical radiography. However, there are some problems such as high x-ray exposure rate and pains for patients because of the problems caused by intra-oral sensor based radiography system. In this study, a new concept of periapical radiography, intra oral X-ray tube and detector system, is introduced to solve these problems. This system is made up of miniature X-ray tube based on subminiature thermal electron or cold electron, CMOS based detector, and a body including automatic position and system control devices. In order to confirm the possibility of proposed new concept to periapical radiography, miniature x-ray tube from XOFT corporation is used to develop new x-ray system, and the performance evaluation of this system is performed according to collimator. Also, dental images are compared after acquiring both images from existing system versus new concept of system. As a result, new concept of system showed excellent image. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

Red fluorescence of oral bacteria interacting with Porphyromonas gingivalis (Porphyromonas gingivalis가 일부 구강미생물의 형광 발현에 미치는 영향)

  • Kim, Se-Yeon;Woo, Dong-Hyeob;Lee, Min-Ah;Kim, Ji-Soo;Lee, Jung-Ha;Jeong, Seung-Hwa
    • Journal of Korean Academy of Oral Health
    • /
    • v.41 no.1
    • /
    • pp.22-27
    • /
    • 2017
  • Objectives: Dental plaque is composed of 700 bacterial species. It is known that some oral microorganisms produce porphyrin, and thus, they emit red fluorescence when illuminated with blue light at a specific wavelength of <410 nm. Porphyromonas gingivalis belongs to the genus Porphyromonas, which is characterized by the production of porphyrin. The aim of this study was to evaluate red fluorescence emission of some oral microorganisms interacting with P. gingivalis. Methods: Five bacterial strains (P. gingivalis, Streptococcus mutans, Lactobacillus casei, Actinomyces naeslundii, and Fusobacterium nucleatum) were used for this study. Tryptic soy agar medium supplemented with hemin, vitamin K3, and sheep blood was used as a growth medium. The fluorescence emission of bacterial colonies was evaluated under 405 nm-wavelength blue light using a Quantitative Light-induced Fluorescence Digital (QLF-D) camera system. Each bacterium was cultured alone and co-cultured in close proximity with P. gingivalis. The red/green (R/G) ratio of fluorescence image was calculated and the differences of R/G ratio according to each growth condition were compared using the Mann-Whitney test (P<0.05). Results: Single cultured S. mutans, L. casei and A. naeslundii colonies emitted red fluorescence (R/G ratio=$2.15{\pm}0.06$, $4.31{\pm}0.17$, $5.52{\pm}1.29$, respectively). Fusobacterium nucleatum colonies emitted green fluorescence (R/G ratio=$1.36{\pm}0.06$). The R/G ratios of A. naeslundii and F. nucleatum were increased when P. gingivalis was co-cultured with each bacterium (P<0.05). In contrast, the R/G ratios of S. mutans and L. casei were decreased when P. gingivalis was co-cultured with each bacterium (P=0.002, 0.003). Conclusions: This study confirmed that P. gingivalis could affect the red fluorescence of other oral bacteria under 405 nm-wavelength blue light. Our findings concluded that P. gingivalis has an important role for red fluorescence emission of dental biofilm.

A Study on Various Sizes and Volumes of the Palate among the Korean Population in Mixed Dentition (한국 인구집단에서 부정교합 환아의 구개의 크기 및 용적에 관한 연구)

  • Jimyung, Choi;Jisun, Shin;Miran, Han;Junhaeng, Lee;Jongsoo, Kim;Jongbin, Kim
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.3
    • /
    • pp.329-339
    • /
    • 2022
  • The purpose of this study was to compare the palatal dimensions (volume, width, length, and height) in different malocclusions (Class I, II, and III) in mixed dentition using a three-dimensional digital scanner. The study was performed on 30 selected casts from 1400 casts that were taken at the Department of Pediatric Dentistry at Dankook University. Casts consisted of Class I, II, and III malocclusion groups in Hellman's dental age IIIA. The mean age was 8 years and 6 months ± 11 months. Each cast was scanned by three-dimensional digital scanner, Medit T710 (Medit, Seoul, Korea), and shaped into the three-dimensional image and calculated palatal dimensions using the Plan T program (SMD solution, Seoul, Korea). The values were statistically compared and evaluated by Kruskal-Wallis followed by the Mann-Whitney test. According to our results, subjects with Class II malocclusion showed lower palatal width and longer palatal length compared to those with Class I and Class III. For palatal height, Class III malocclusion subjects in mixed dentition exhibited a larger number than Class II and Class I. Lastly, for palatal volume, compared to other malocclusions, Class III showed higher results; however, there were no significant differences. The form of the palate differs in types of malocclusions and understanding of these differences is important in clinical significance. Based on this study, the understanding of the relationship between the shape of the palate and the skeletal pattern provides useful information about orthodontic treatment plans, early diagnosis of malocclusion, and morphological integration mechanisms. Orthopedic treatment in the maxilla should be performed during early and intermediate mixed dentition to enhance treatment efficiency.

Three-dimensional morphometric analysis of mandibule in coronal plane after bimaxillary rotational surgery

  • Lee, Sung-Tak;Choi, Na-Rae;Song, Jae-Min;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.49.1-49.9
    • /
    • 2016
  • Background: The aim of this report is to present a new reference for aesthetic mandible surgery using three-dimensional cone-beam computed tomography-based treatment planning for orthognathic surgery which can be implemented in surgical planning and perioperative procedure. Methods: To make an objective standard for evaluating aesthetic mandibular outline, we make an aesthetic scoring criteria with consideration of asymmetry, broad mandibular border line, and prominent mandibular angle. Two maxillofacial surgeons and two orthodontists rated their aesthetical evaluation from 1 to 5. Experimental group consisting of 47 female and 38 male patients who had rotational orthognathic two-jaw surgery from 2010 to 2011 were chosen according to aesthetic scoring done by two maxillofacial surgeons and two orthodontists. A high aesthetic score (${\geq}16$) means the facial contour is symmetric, with no broad and narrow aesthetic mandible frontal profiles. Control A group consisted of ten female and ten male patients who had no orthognathic surgery experience and low aesthetic score (${\geq}10$). Control B group consisted of ten female and ten male patients who had no orthognathic surgery experience and had anaesthetic mandibular frontal profile and a high aesthetic score (${\geq}16$). The three-dimensional image of the patient was taken from dental cone-beam CT (DCT) scanning (experimental group and control A group: 6 months DCT after surgery, control B group: 1st visit DCT). Each DCT was reformatted to reorient the 3D image using 3D analyzing program (OnDemand3D, cybermed Inc, CA, USA). After selection of 12 landmarks and the construction of reoriented horizontal, vertical, and coronal reference lines, 15 measurements were taken in 3D analysis of frontal mandibular morphology. Afterwards, horizontal and vertical linear measurements and angular measurements, linear ratio were obtained. Results: Mean $Go^{\prime}_{Rt}-Me^{\prime}-Go^{\prime}_{Lt}$ angular measurement was $100.74{\pm}2.14$ in female patients and $105.37{\pm}3.62$ in male patients. These showed significant difference with control A group in both genders. Ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}-Me^{\prime}$ length to some linear measurements (ratio of $Me^{\prime}-Cd^{\prime}_{Rt}Cd^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Me^{\prime}-Go^{\prime}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$) showed significant difference with control A group in both genders. Conclusion: This study was intended to find some standard measurement of mandible frontal view in 3D analysis of aesthetic patient. So, these potential measurement value may be helpful for orthognathic treatment planning to have more aesthetic and perspective outcomes.

A STUDY ON THE SELECTION OF THE MAXILLARY ANTERIOR ARTIFICIAL TEETH IN KOREAN ADULTS (한국 성인의 상악 전치부 인공치아 선택기준에 관한 계측학적 연구)

  • Ahn Hyun-Jeong;Yang Hong-So;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.484-492
    • /
    • 2002
  • The selection of the maxillary anterior artificial teeth is made primarily for esthetics and they must be in harmony with the surrounding oral environment. However the selection of artificial teeth is based on the large degree of subjective judgement or the dentists, therefore, this is one of the most unscientific processes. This study was performed to determine clinically whether there is correlation among the width of the maxillary central incisor(WMCI), the intercanine distance (ICD) the facial width(FW), and the interalar nasal width(IAW) in Korean adults, and to provide the selection standards for the maxillary anterior artificial teeth. The casts were obtained from 91 undergraduate dental students(49 males and 42 females) with Angle's class I occlusion presenting well-arranged intact anterior teeth. The WMCI and ICD were measured on the casts with a vernier calipers($Miltex^{(R)}$, Germany). The photographic procedures under standardized conditions were performed to record each subject's frontal face using digital camera($Olympus^{(R)}$, C-2500L, Japan). The FW and IAW were measured with image analyzer($Image-Pro^{(R)}$ PLUS. media cybermetrics. USA). The results were obtained as follows : 1. The mean WMCI was $8.11{\pm}0.67mm$, ICD was $37.88{\pm}2.15mm$, FW was $141.29{\pm}5.84mm$. and IAW was $37.85{\pm}2.29 mm$. 2. The ratios of FW/WMCI, FW/ICD, IAW/ICD were 17.4, 3.7, 1.0 respectively. 3. All measurements(WMCI, ICD, FW, and IAW) of male group were longer than those of female group significantly in Student's t-test(p<0.01). 4. There was significant correlation between WMCI, ICD, FW, and IAW in Pearson's correlation analysis(p<0.01). 5, The relationship between IAW and ICD shows the strongest correlation among six combinations in linear regression analysis($R^2$=0.753, Y=7.046+0.815X). The FW and IAW could be very reliable guides for the selection of the maxillary anterior artificial teeth.

Open versus closed reduction of mandibular condyle fractures : A systematic review of comparative studies

  • Kim, Jong-Sik;Seo, Hyun-Soo;Kim, Ki-Young;Song, Yun-Jung;Kim, Seon-Ah;Hong, Soon-Min;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.1
    • /
    • pp.99-107
    • /
    • 2008
  • Objective : The objective of this review was to provide reliable comparative results regarding the effectiveness of any interventions either open or closed that can be used in the management of fractured mandibular condyle Patients and Methods : Research of studies from MEDLINE and Cochrane since 1990 was done. Controlled vocabulary terms were used. MeSH Terms were "Mandibular condyle" AND "Fractures, bone". Only comparative study were considered in this review using the "limit" function. According to the criteria, two review authors independently assessed the abstracts of studies resulting from the searches. The studies were divided according to some criteria, and following were measured: Ramus height, condyle sagittal displacement, condyle Towns's image displacement, Maximum open length, Protrusion & Lateral excursion, TMJ pain, Malocclusion, and TMJ disorder. Results : Many studies were analyzed to review the post-operative result of the two methods of treatment. Ramus height decreased more in when treated by closed reduction as opposed to open reduction. Sagittal condyle displacement was shown to be greater in closed reduction. Condyle Town's image condyle displacement had greater values in closed reduction. Maximum open length showed lower values in closed reduction. In protrusive and lateral movement, closed reduction was less than ORIF. Closed reduction showed greater occurrence of malocclusion than ORIF. However, post-operative pain and discomfort was greater in ORIF. Conclusion : In almost all categories, ORIF showed better results than CRIF. However, the use of the open reduction method should be considered due to the potential surgical morbidity and increased hospitalization time and cost. To these days, Endoscopic surgical techniques for ORIF (EORIF) are now in their infancy with the specific aims of eliminating concern for damage to the facial nerve and of reducing or eliminating facial scars. Before performing any types of treatment, patients must be understood of both of the treatment methods, and the best treatment method should be taken on permission.

The Influence of Microwave Sintering Process on the Adaptation of CAD/CAM Zirconia Core (마이크로 웨이브 소결 과정이 CAD/CAM 지르코니아 코아의 적합도에 미치는 영향)

  • Kim, Keun Bae;Kim, Jee Hwan;Lee, Keun-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.95-107
    • /
    • 2009
  • The purpose of this research was to examine the fitness of zirconia cores that were made by different sintering methods; generic electricity furnace and microwave furnace. Firstly, 12 cores for each group were made by using each different sintering process and attached them to a metal die with silicon. The internal and marginal gap of sintered zirconia was measured by using Skyscan 1076 micro-CT, then it was reorganized by CT-An software. To each samples, we extracted B-L image, M-D image of cutting side, and cross-sectional side of tooth long axis and calculated the mean value of marginal, axial, and occlusal gap each side. Results: 1. The mean marginal gap of sintered zirconia was $36.20{\mu}m$ for EVE, $47.67{\mu}m$ for LAV, $52.47{\mu}m$ for DEN, and $54.63{\mu}m$ for CER. 2. For the axial wall, the research showed the largest value of $63.49{\mu}m$ for EVE, but there were no statistical significance. 3. In related to the occlusal internal measurement, DEN showed the smallest value ($77.06{\mu}m$), EVE and CER showed significantly high value. From this study, it is suggested that CAD/CAM zirconia core which was made in the process of microwave sintering has clinically acceptable values in marginal and internal gap.

Bony change of apical lesion healing process using fractal analysis (프랙탈 분석을 이용한 치근단병소 치유과정의 골 변화)

  • Lee Ji-Min;Park Hyok;Jeong Ho-Gul;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.35 no.2
    • /
    • pp.91-96
    • /
    • 2005
  • Purpose : To investigate the change of bone healing process after endodontic treatment of the tooth with an apical lesion by fractal analysis. Materials and Methods Radiographic images of 35 teeth from 33 patients taken on first diagnosis, 6 months, and 1 year after endodontic treatment were selected. Radiographic images were taken by JUPITER Computerized Dental X-ray $System^{(R)}$. Fractal dimensions were calculated three times at each area by Scion Image $PC^{(R)}$ program. Rectangular region of interest $(30\times30)$ were selected at apical lesion and normal apex of each image. Results : The fractal dimension at apical lesion of first diagnosis $(L_0)$ is $0.940{\pm}0.361$ and that of normal area $(N_0)$ is $1.186{\pm}0.727(p<0.05)$. Fractal dimension at apical lesion of 6 months after endodontic treatment $(L_1)$ is $1.076{\pm}0.069$ and that of normal area $ (N_1)$ is $1.192{\pm}0.055(p<0.05)$. Fractal dimension at apical lesion of 1 year after endodontic treatment $(L_2)$ is $1.163{\pm}0.074$ and that of normal area $(N_2)$ is $1.225{\pm}0.079(p<0.05)$. After endodontic treatment, the fractal dimensions at each apical lesions depending on time showed statistically significant difference. And there are statistically significant different between normal area and apical lesion on first diagnosis, 6 months after, 1 year after. But the differences were grow smaller as time flows. Conclusion : The evaluation of the prognosis after the endodontic treatment of the apical lesion was estimated by bone regeneration in apical region. Fractal analysis was attempted to overcome the limit of subjective reading, and as a result the change of the bone during the healing process was able to be detected objectively and quantitatively.

  • PDF