Khedmat, Sedigheh;Dehghan, Somayyeh;Hadjati, Jamshid;Masoumi, Farimah;Nekoofar, Mohammad Hossein;Dummer, Paul Michael Howell
Restorative Dentistry and Endodontics
/
제39권3호
/
pp.149-154
/
2014
Objectives: This study was performed to evaluate the cytotoxicity of four calcium silicate-based endodontic cements at different storage times after mixing. Materials and Methods: Capillary tubes were filled with Biodentine (Septodont), Calcium Enriched Mixture (CEM cement, BioniqueDent), Tech Biosealer Endo (Tech Biosealer) and ProRoot MTA (Dentsply Tulsa Dental). Empty tubes and tubes containing Dycal were used as negative and positive control groups respectively. Filled capillary tubes were kept in 0.2 mL microtubes and incubated at $37^{\circ}C$. Each material was divided into 3 groups for testing at intervals of 24 hr, 7 day and 28 day after mixing. Human monocytes were isolated from peripheral blood mononuclear cells and cocultered with 24 hr, 7 day and 28 day samples of different materials for 24 and 48 hr. Cell viability was evaluated using an MTT assay. Results: In all groups, the viability of monocytes significantly improved with increasing storage time regardless of the incubation time (p < 0.001). After 24 hr of incubation, there was no significant difference between the materials regarding monocyte viability. However, at 48 hr of incubation, ProRoot MTA and Biodentine were less cytotoxic than CEM cement and Biosealer (p < 0.01). Conclusions: Biodentine and ProRoot MTA had similar biocompatibility. Mixing ProRoot MTA with PBS in place of distilled water had no effect on its biocompatibility. Biosealer and CEM cement after 48 hr of incubation were significantly more cytotoxic to on monocyte cells compared to ProRoot MTA and Biodentine.
Lima, Adriano Fonseca;Formaggio, Stephanie Ellen Ferreira;Zambelli, Ligia Franca Aires;Palialol, Alan Rodrigo Muniz;Marchi, Giselle Maria;Saraceni, Cintia Helena Coury;de Oliveira, Marcelo Tavares
Restorative Dentistry and Endodontics
/
제41권4호
/
pp.271-277
/
2016
Objectives: In this study, we evaluated the influence of different radiant exposures provided by single-peak and polywave light-curing units (LCUs) on the degree of conversion (DC) and the mechanical properties of resin cements. Materials and Methods: Six experimental groups were established for each cement (RelyX ARC, 3M ESPE; LuxaCore Dual, Ivoclar Vivadent; Variolink, DMG), according to the different radiant exposures (5, 10, and $20J/cm^2$) and two LCUs (single-peak and polywave). The specimens were made (7 mm in length ${\times}$ 2 mm in width ${\times}$ 1 mm in height) using silicone molds. After 24 hours of preparation, DC measurement was performed using Fourier transform infrared spectrometry. The same specimens were used for the evaluation of mechanical properties (flexural strength, FS; elastic modulus, E) by a three-point bending test. Data were assessed for normality, after which two-way analysis of variance (ANOVA) and post hoc Tukey's test were performed. Results: No properties of the Variolink cement were influenced by any of the considered experimental conditions. In the case of the RelyX ARC cement, DC was higher when polywave LCU was used; FS and E were not influenced by the conditions evaluated. The LuxaCore cement showed greater sensitivity to the different protocols. Conclusions: On the basis of these results, both the spectrum of light emitted and the radiant exposure used could affect the properties of resin cements. However, the influence was material-dependent.
본 연구는 치과용시멘트의 표면특성과 구강세균 부착을 위해 치과용시멘트액에 저분자키토산(Low molecular chitosan: LC)을 무게비로 0, 0.5, 1.0, 2.0 wt%를 첨가하였다. 시멘트의 경화시간과 표면특성으로 표면에너지와 표면거칠기를 평가하였다. 구강세균 부착정도는 구강세균 S. mutans, E.coli 2개의 균주를 이용하여 평가하였다. 실험 결과 경화시간은 LC0.5실험군에서 증가하였으나 통계적 유의한 차이는 나타나지 않았다(p<0.05). 표면거칠기는 LC2.0실험군에서 유의한 차이를 보였으며 구강 세균 부착실험 결과 저분자키토산을 첨가한 실험군 모두 통계적으로 유의하게 낮은 부착양상을 보였다(p<0.05). 본 연구로 저분자키토산의 표면특성과 구강세균 부착억제효과가 있음을 입증하였다. 향후 저분자키토산 첨가양에 따른 효율성과 폭 넓은 물성 연구가 필요할 것으로 사료된다.
The purpose of this study was to investigate the effect of calcium hydroxide and glass ionomer cement fillings on the levels of $LTB_4$ and $LTC_4$ in experimentally inflamed rat dental pulp. The dental pulp in the mandibular incisor of wistar rat was irritated by cutting a 5mm deep hole in the dentin with a twist drill bur of 0.5mm diameter, without cooling. The cavities were filled with calcium hydroxide(light-cured) and glass ionomer cement(light cured). The untreated pulp served as control tissue specimen. After cavity preparations, the rat with or without various treatment were sacrificed in various time by decapitation. The dental pulp tissue were carefully removed and the concentrations of $LTB_4$ and $LTC_4$ were determined by radioimmunoassay. And pulps were examined histologically to observe inflammatory feature. The result were obtained as follows : 1. The inflammatory features of pulps were observed microscopically in all experimental groups. And degree of inflammation was decreased with time. 2. The concentrations of $LTB_4$ and $LTC_4$ for all experimental groups were significantly higher than those for control group 6 hours after cavity preparation(p<0.05). 3. The group filled with calcium hydroxide was the lowest, and the group filled with glass ionomer cement, the group of irritation in that order showed increased concentrations of $LTB_4$ and $LTC_4$ 6 hours after cavity preparation. In the concentrations of $LTB_4$, significant differences among 3 groups were noted(p<0.05). 4. The group filled with calcium hydroxide was the lowest, and the group filled with glass ionomer cement, the group of irritation in that order showed increased concentrations of $LTB_4$ and $LTC_4$ 24 hours after cavity preparation. And there were statistically significant difference in concentrations of $LTB_4$ between the group of irritation and the group filled with calcium hydroxide(p<0.05). 5. The group filled with calcium hydroxide was the lowest, and the group filled with glass ionomer cement, the group of irritation in that order showed increased concentrations of $LTB_4$ and $LTC_4$ 48 hours after cavity preparation. But no statistically difference was found (p>0.05). 6. The concentrations of $LTB_4$ and $LTC_4$ in all experimental groups were highest level at 6 hour after experiment and decreased as time progresses(correlation coefficient>0.8).
PURPOSE. This study evaluated the adhesion of 10-MDP containing self-etch and self-adhesive resin cements to dentin with and without the use of etch-and-rinse technique. MATERIALS AND METHODS. Human third molars (N=180) were randomly divided into 6 groups (n=30 per group). Conventional (Panavia F2.0, Kuraray-PAN) and self-adhesive resin cements (Clearfil SA, Kuraray-CSA) were bonded to dentin surfaces either after application of 3-step etch-and-rinse (35% $H_3PO_4$ + ED Primer) or two-step self-etch adhesive resin (Clearfil SE Bond). Specimens were subjected to shear bond strength test using the universal testing machine (0.5 mm/min). The failure types were analyzed using a stereomicroscope and quality of hybrid layer was observed under a scanning electron microscope. The data (MPa) were analyzed using two-way ANOVA and Tukey's tests (${\alpha}$=.05). RESULTS. Overall, PAN adhesive cement showed significantly higher mean bond strength ($12.5{\pm}2.3-14.1{\pm}2.4$ MPa) than CSA cement ($9.3{\pm}1.4-13.9{\pm}1.9$ MPa) (P<.001). Adhesive failures were more frequent in CSA cement groups when used in conjunction with two-step self-adhesive (68%) or no adhesive at all (66%). Hybrid layer quality was inferior in CSA compared to PAN cement in all conditions. CONCLUSION. In clinical situations where bonding to dentin substrate is crucial, both conventional and self-adhesive resin cements based on 10-MDP can benefit from etch-and-rinse technique to achieve better quality of adhesion in the early clinical period.
purpose: This study was to evaluate the shear bond strength of Lithium Disilicate Glass-Ceramic by removable method of temporary cement on the abutment tooth. Material and Method: Sixty molar teeth of human with the occlusal surface up were mounted in acrylic resin blocks. The 45 specimens were prepared to exposure dentin by diamond bur and the eugenol-containing temporary cement($Cavitec^{TM}$ ($KERR^{(R)}$, U.S.A)was applied to the dentin surfaces. After initial removal of the cement with a dental explorer, the specimens were divided into 4 groups of 15 specimens each. The dentin surfaces of the specimens were treated by rotary instrument with as follow pastes: $Zircate^{(R)}$ prophy paste(Dentsply, U.S.A), Radent Prophy Paste(Pascal company,inc. U.S.A), and Dental pumice(Wip mix corporation,U.S.A). An adhesive resin luting agent(Variolink $II^{(R)}$, Ivoclar Vivadent, Leichtenstein) including Monobond-S and $Excite^{(R)}$ was applied to all specimens. The ceramic specimens were made with an A1 ingot of IPS Empress $II^{(R)}$ (Ivoclar Vivadent, Leichtenstein). After the specimens were stored in distilled water for 48hr, the shear bond strength(MPa) was measured by a Universal testing machine(Zwick 145641, Zwick, Germany) at a 1mm/min cross-head speed. The data were statistically analyzed by one-way ANOVA and Duncan's multiple range test. Results: In all group, there were no significant differences in comparison with the control group(p>0.05). The pattern of most failure showed the mixed type of cohesive and adhesive failure. Conclusion: Resin bond strength of IPS Empress $II^{(R)}$ was not affected by removal method of the temporary cement.
The radiopacity of glass ionomer cements is quite variable. The use of a poorly radiopaque material as a base under other restorative materials can mislead the dentist to a diagnosis of recurrent decay. This study investigates the radiopacity of these materials and proposes a minimal radiopacity under which a material should not be used as a base or liner. It is important to determine the radiopacity of glass ionomer dental materials so that the clinician can appreciate the type of restorative materials used when radiographically evaluation the possibility of recurrent dental caries. In this study, radiopacity of Vitrement and Chemfil was compared with that of Cavalite, Miracle mix and polycarboxylate cement. Tooth model of artificial cavity preparation for diagnosis of recurrent caries was omitted. Radiopacity of each material was measured using relatives between thickness and radiopacity of Aluminium step wedge. The results were as follows : 1. Radiopacity of Vitrement was some higher than enamel. 2. Chemfil, restorative glass ionomer, was less radiopaque than enamel. 3. In order of higher radiopacity than enamel, Miracle mix was highest and was followed by polycarboxylate cement, Cavalite and Vitremer. 4. Vitremer, the Glass Ionomer Cement, is useful to detection of recurrent caries, because it is slightly higher radiopaque than enamel. So, it is suitable for restorative material and luting cement.
Objectives: To determine the retentive strength and failure mode of undercut composite post, glass fiber post and polyethylene fiber post luted with flowable composite resin and resin-cement. Materials and Methods: Coronal parts of 120 primary canine teeth were sectioned and specimens were treated endodontically. The teeth were randomly divided into 6 groups (n = 20). Prepared root canals received intracanal retainers with a short composite post, undercut composite post, glass fiber post luted with flowable resin or resin-cement, and polyethylene fiber post luted with flowable resin or resin-cement. After crown reconstruction, samples were tested for retentive strength and failure mode. Statistical analysis was done with one-way ANOVA and Tukey tests (p < 0.05). Results: There were statistically significant differences between groups (p = 0.001). Mean bond strength in the undercut group was significantly greater than in the short composite post (p = 0.030), and the glass fiber post (p = 0.001) and the polyethylene fiber post group luted with resin-cement (p = 0.008). However, the differences between the undercut group and the groups with flowable composite as the luting agent were not significant (p = 0.068, p = 0.557). Adhesive failure was more frequent in the fiber post groups. Conclusions: Although the composite post with undercutting showed the greatest resistance to dislodgement, fiber posts cemented with flowable composite resin provided acceptable results in terms of retentive strength and fracture mode.
Zortuk, Mustafa;Gumus, Hasan Onder;Kilinc, Halil Ibrahim;Tuncdemir, Ali Riza
The Journal of Advanced Prosthodontics
/
제4권4호
/
pp.192-196
/
2012
PURPOSE. The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS. In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (${\alpha}$=0.05). RESULTS. The dentin cleaning methods did not significantly affect the SBS of ceramic discs to dentin as follows: dental explorer, pumice, cleaning bur, and Er:YAG laser. CONCLUSION. The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces.
Ultrasonic instruments transfer electrical energy to mechanical energy resulting in vibration used for various dental treatments. If we could know the effect of ultrasonic instruments on the dental cements within the cast crown, we could take care when conducting periodontal surgery and when using the ultrasonic instrument to remove cast crown, it would be much more convenient. The purpose of this study was to compare the bond strength of several dental cements according to ultrasonic instrumentation time. In this study 4 types of cements were used to cement the specimens. they were treated with ultrasonic instrumentation for 0-5 minutes and the change in bond strength were statistically compared. The results were as followed. 1. The tensile bond strength of zinc phosphate cement decreased according to the increase in time of ultrasonic instrument and showed significant difference between 0 minutes and the others and between 1 minute and 2,3,4,5 minutes (p<0.05). 2. The tensile bond strength of polycarboxylate cement decreased according to the increase in time of ultrasonic instrument and showed significant difference between 5 minutes and the others and between 4 minutes and 0 minutes (p<0.05). 3. The tensile bond strength of zinc phosphate cement decreased according to the increase in time of ultrasonic instrument and showed significant difference between 5 minutes and the others (p<0.05). 4. The tensile strength of resin cements showed no statistically differences according to the ultrasonic instrumentation time. In conclusion, it is considered that zinc phosphate cements is most affected by ultrasonic instrumentations and resin cement is the least affected. When using ultrasonic instruments the result avove should be used as an index.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.