• Title/Summary/Keyword: Dental Bonding

Search Result 380, Processing Time 0.026 seconds

The effect of bonded resin surface area on the detachment force of lingual bonded fixed retainers: An in vitro study

  • Lee, Il-Hong;Lee, Jung-Hwan;Park, In-Young;Kim, Ji-Hyun;Ahn, Jang-Hoon
    • The korean journal of orthodontics
    • /
    • v.44 no.1
    • /
    • pp.20-27
    • /
    • 2014
  • Objective: The aims of this study were to evaluate the relationship between the detachment force and bonding resin surface are and to determine the resin bonding surface area that would provide adequate bonding strength with minimum resin volume. Methods: One hundred and sixty human premolars were randomly divided into 4 groups of 40 teeth each. The diameter of the resin surface area in each group was as follows: group 1, 1.5 mm; group 2, 2.5 mm; group 3, 3.5 mm; and group 4, 4.5 mm. Respond Dead Soft straight (length 0.0175 inch) was used to fabricate the retainers, and $Transbond^{TM}$ XT was used to fix the retainers to the tooth surfaces. A pair of teeth was embedded in acrylic blocks for each specimen. Thus, each group comprised 20 samples. Fixed retainers were bonded to the teeth, and vertical force was applied at the middle of wire. The force was measured using a universal testing machine. Results: The mean value of detachment force was the highest for group 4 ($102.38{\pm}2.92N$), followed by group 3 ($63.54{\pm}2.21N$), group 2 ($51.95{\pm}1.61N$), and group 1 ($24.14{\pm}1.38N$). Conclusions: The detachment force of lingual fixed retainers was significantly affected as the area of the resin bonding surface increased. Considering the minimum bonding strength of brackets, a resin bonding surface area with a diameter of 3.5 mm would provide adequate bonding strength.

Surface Analysis of Ni-Cr and Co-Cr Alloys with Addition of Ti and Mo for Dental CAD/CAM Use (Ti 및 Mo 첨가에 따른 치과 CAD/CAM용 Ni-Cr 및 Co-Cr합금의 표면분석)

  • Moon, Dae-Sun;Choe, Han-Cheol
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.3
    • /
    • pp.139-148
    • /
    • 2018
  • In this study, surface analysis of Ni-Cr and Co-Cr alloys with addition of Ti and Mo for dental CAD/CAM use has been researched experimentally. The surface characteristics of the alloys were examined by Vickers hardness test, bonding strength test, surface roughness test, field-emission scanning electron microscopy, energy dispersive X-ray spectroscopy, and X-ray diffraction spectroscopy. The shrinkage of the sintered Ni-Cr alloy alloy was slightly larger than that of Ni-Cr-Ti alloy, and larger than Co-Cr alloy. Also, the addition of Mo showed a tendency to decrease shrinkage somewhat. From the result of XRD analysis, NiCr, $Ni_3Cr$ and $Ni_3Ti$ were observed in the sintered Ni-13Cr-xTi and Ni-13Cr-xMo alloys. In addition, ${\sigma}-CrCo$, $Co_2Mo_3$ and $TiCo_2$ were formed in the sintered Co-Cr-xTi and Co-Cr-xMo alloys. Surface hardness of Ti and Mo added alloy was higher than those of Ni-Cr and Co-Cr alloy. The bond strength between sintered alloy and porcelain was $16.1kgf/mm^2$ for Ni-13Cr alloy, $17.8kgf/mm^2$ for Ni-13Cr-5Ti alloy, and $8.2kgf/mm^2$ for Ni-13Cr-10Ti alloy, respectively.

ESTHETIC RESTORATION OF ANTERIOR STAINLESS STEEL CROWN WITH COMPOSITE RESIN VENEER (Stainless steel crown 순면위에 레진피복을 이용한 전치부 심미적 수복)

  • Park, Jong-Ha;An, Soo-Hyeon;Kim, Jae-Gon;Baik, Byeong-Ju
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.4
    • /
    • pp.805-812
    • /
    • 1997
  • Despite dentistry's attempts to improve the dental health of the public and to minimize the effects of caries, many children still present with extensive destruction of primary anterior teeth. One of dentistry's most challenging tasks is to repair these teeth with restoration which are durable, retentive, and esthetic. Esthetic restoration can often be achieved with polycarbonate crowns, strip crowns, conventional S-S crowns, open-faced S-S crowns, commercially veneered S-S crowns. But, all of these have limitation. Advances in restorative materials and metal-bonding procedures have made possible new restorative techniques that combine the advantages of S-S crowns with the cosmetics of composite restoration methods. The described technique of bonding composite to trimmed and fitted S-S crowns offers many advantages over other techniques currently used to restore primary anterior teeth. 1. If S-S crowns are accurate trimmed and contoured, good retention of crowns is achieved. 2. The patient time required is similar to that of conventional S-S crowns. 3. Good esthetics and high bond strengths are achieved. 4. It is possible to use this veneering technique intraorally on crowns that have fractured veneers.

  • PDF

Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies

  • Bastos, Laura Alves;Sousa, Ana Beatriz Silva;Drubi-Filho, Brahim;Pires-de-Souza, Fernanda de Carvalho Panzeri;Garcia, Lucas da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • v.40 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Objectives: The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Materials and Methods: Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens ($1.0{\times}1.0mm$), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing. Results: Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05). However, it was not significantly different from Pre-etching/Silorane and Methacrylate groups. Conclusions: Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin.

Hardening mechanism associated with post-firing heat treatment of softening heat treated and then firing simulated Pd-Ag-Au alloy for bonding porcelain (연화 열처리 후 모의소성된 금속-세라믹용 Pd-Ag-Au계 합금의 후열처리에 의한 경화기전)

  • Kim, Sung-Min;Yu, Young-Jun;Cho, Mi-Hyang;Kwon, Yong-Hoon;Kim, Hyung-Il;Seol, Hyo-Joung
    • Korean Journal of Dental Materials
    • /
    • v.42 no.2
    • /
    • pp.95-106
    • /
    • 2015
  • Hardening mechanism associated with post-firing heat treatment of softening heat treated and then firing simulated Pd-Ag-Au alloy for bonding porcelain was examined by observing the change in hardness, crystal structure and microstructure. By post-firing heat treatment of as-cast, solution treated and pre-firing heat treated specimens at $650^{\circ}C$ after casting, the hardness value increased within 10 minutes. Then, hardness consistently increased until 30 minutes, and gap of hardness value among the specimens was reduced. The increase in hardness after post-firing heat treatment was caused by grain interior precipitation in the matrix. The softening heat treatment did not affect the increase in hardness by post-firing heat treatment. The precipitated phase from the parent Pd-Ag-Au-rich ${\alpha}$ phase with face-centered cubic structure by post-firing heat treatment was $Pd_3$(Sn, In) phase with face-centered tetragonal structure, which has lattice parameters of $a_{200}=4.0907{\AA}$, $c_{002}=3.745{\AA}$. From above results, appropriate post-firing heat treatment in order to support the hardness of Pd-Ag-Au metal substructure was expected to bring positive effects to durability of the prosthesis.

Management of dental erosion induced by gastro-esophageal reflux disorder with direct composite veneering aided by a flexible splint matrix

  • Chockattu, Sherin Jose;Deepak, Byathnal Suryakant;Sood, Anubhav;Niranjan, Nandini T.;Jayasheel, Arun;Goud, Mallikarjun K.
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.13.1-13.7
    • /
    • 2018
  • Dental erosion is frequently overlooked in clinical practice. The management of erosion-induced damage to the dentition is often delayed, such that extensive occlusal rehabilitation is required. These cases can be diagnosed by a careful clinical examination and a thorough review of the patient's medical history and/or lifestyle habits. This case report presents the diagnosis, categorization, and management of a case of gastro-esophageal reflux disease-induced palatal erosion of the maxillary teeth. The early management of such cases is of utmost importance to delay or prevent the progression of damage both to the dentition and to occlusal stability. Non-invasive adhesively bonded restorations aid in achieving this goal.

A Study on the Processing of Soft Base Denture (SOFT BASE DENTURE 제작에 관한 연구)

  • Shin, Moo-Hak
    • Journal of Technologic Dentistry
    • /
    • v.20 no.1
    • /
    • pp.21-25
    • /
    • 1998
  • A detailed description of the Laboratory Processing procedures for Soft Base Denture that varies from those offered by the manufacturer has provid to be effective. As follows ; 1. Pomotion of patient's comfortability 2. increase in denture retention 3. because of the same heat-curing denture materials used improves bonding & endurance 4. often used denture refitting 5. reducing the rate of alveolar absorption The processing for soft base denture is very sensitive, consequntly.

  • PDF

Chemical compatibility of interim material and bonding agent on shear bond strength (임시수복 재료와 본딩제의 화학적 호환성이 전단결합강도에 미치는 영향)

  • Lee, Jonghyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.4
    • /
    • pp.293-300
    • /
    • 2016
  • Purpose: The purpose of this study is finding proper bonding agents to be used when adding bis-acryl composite provisional materials. Materials and Methods: Three bonding agents with different chemical compositions were included in this study. Forty disk shaped specimens of bis-acryl composite provisional material were prepared and divided into 4 groups according to the bonding agents. Control group didn't have bonding agent. Through the Teflon mould with 4.0 mm diameter hole with 4.0 mm thickness the same bis-acryl composite provisional material was added on the disks after the surface of each specimen was treated with designated bonding agent according to the manufacturer's instructions. Shear bond test was performed and the fractured surfaces were inspected with a microscope. One-way analysis of variance was conducted and the result was further analysed with Turkey post hoc test at the significance level of 0.05. Results: The highest strength was acquired from the specimens bonded with chemical cure system and it was statistically significant (P < 0.05). This group showed 100% cohesive failures. The lowest bonding strength was recorded from the specimens used conventional light cure bonding agent, and this group's result was similar with the control group. The group used a light cure bonding agent claiming improved compatibility revealed significantly higher bond strength to the traditional light cure bonding agent group in a statistically significant way (P = 0.043). Conclusion: According to the bonding agent used the shear bond strength was significantly affected. Therefore the choice of proper bonding agent is important when hiring a bonding agent to add bis-acryl composite provisional materials.

Comparison of dental porcelain baking methods by base-alloy and bonding strength by thermocycling (Base-Alloy에 따른 치과 도재의 소성방법과 열순환에 따른 결합강도 비교)

  • Kim, Im-Sun;Min, Kyung-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.772-779
    • /
    • 2010
  • This study measured the bonding strength of various porcelain prosthesis materials before and after thermocycling to select prosthesis materials that can maximize beauty and tolerance. To measure bonding strength, various porcelain materials were baked on with-Beryllium metals, non-Beryllium metals 8group and Zirconia 1 group among commercially available base alloys, and measured the bonding strength was measured before and after thermocycling. The findings of this study are as follows: 1) PTM(press-to-metal) porcelain non-Beryllium metal showed the, highteat bonding strength each 73.2MPa, 59.2MPa before and after thermocycling. 2) The porcelain materials baked on non-Beryllium metal showed higher bonding strength before and after thermocycling than those baked on with-Beryllium metal. 3) Zirconia products showed the lowest 38.7MPa bonding strength before and after thermocycling.