• 제목/요약/키워드: Dent Test

검색결과 34건 처리시간 0.026초

A Study on 3-Dimensional Profilometry of Steam Generator Tube Using a New Eddy Current Probe

  • Kim, Young-Kyu;Song, Myung-Ho;Choi, Myung-Sik
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.225-235
    • /
    • 2010
  • There are many types of the geometric transitions such as dent, bulge, protrusion, expansion, etc, on the inner and outer surfaces of heat exchanger tubes, steam generator tubes, and condenser tubes of nuclear power plants. Such geometric transition causes a local residual stress in heat exchanger tubes and acts as a structural factor accelerating the evolution of defects, in particular stress corrosion cracks. In the conventional eddy current test methods, the bobbin coil profilometry can provide 2-dimensional geometric information on the variation of the average inner diameter along the tube length, but the 3-dimensional distribution and the quantitative size of a local geometric transition existing in the tube cannot be measured. In this paper, a new eddy current probe, developed for the 3-dimensional profile measurement, is introduced and its superior performance is compared with that from the conventional bobbin coil profilometry for the various types of geometric transition. Also, the accuracy of the probe for the quantitative profile measurement is verified by comparing the results with that from the laser profilometry. It is expected that the new eddy current probe and techniques can be effectively used for an optimization of the tube expansion process, and the management of tubes with geometric transitions in service.

유한요소해석을 통한 섬유보강 아스팔트의 파괴거동특성 분석 (Finite Element Analysis for Fracture Resistance of Fiber-reinforced Asphalt Concrete)

  • 백종은;유평준
    • 한국도로학회논문집
    • /
    • 제17권3호
    • /
    • pp.77-83
    • /
    • 2015
  • PURPOSES : In this study, a fracture-based finite element (FE) model is proposed to evaluate the fracture behavior of fiber-reinforced asphalt (FRA) concrete under various interface conditions. METHODS : A fracture-based FE model was developed to simulate a double-edge notched tension (DENT) test. A cohesive zone model (CZM) and linear viscoelastic model were implemented to model the fracture behavior and viscous behavior of the FRA concrete, respectively. Three models were developed to characterize the behavior of interfacial bonding between the fiber reinforcement and surrounding materials. In the first model, the fracture property of the asphalt concrete was modified to study the effect of fiber reinforcement. In the second model, spring elements were used to simulated the fiber reinforcement. In the third method, bar and spring elements, based on a nonlinear bond-slip model, were used to simulate the fiber reinforcement and interfacial bonding conditions. The performance of the FRA in resisting crack development under various interfacial conditions was evaluated. RESULTS : The elastic modulus of the fibers was not sensitive to the behavior of the FRA in the DENT test before crack initiation. After crack development, the fracture resistance of the FRA was found to have enhanced considerably as the elastic modulus of the fibers increased from 450 MPa to 900 MPa. When the adhesion between the fibers and asphalt concrete was sufficiently high, the fiber reinforcement was effective. It means that the interfacial bonding conditions affect the fracture resistance of the FRA significantly. CONCLUSIONS : The bar/spring element models were more effective in representing the local behavior of the fibers and interfacial bonding than the fracture energy approach. The reinforcement effect is more significant after crack initiation, as the fibers can be pulled out sufficiently. Both the elastic modulus of the fiber reinforcement and the interfacial bonding were significant in controlling crack development in the FRA.

자동차용 깊은홈 볼베어링의 조기파손 : 1보 - 파손기구의 규명 (Premature Failure of Deep Grooved Ball Bearing for Automobiles : Part 1 - A Failure Mechanism)

  • 현준수;박태조
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2003년도 학술대회지
    • /
    • pp.388-394
    • /
    • 2003
  • This paper deals with a premature failure mechanism of deep grooved ball bearing for automobiles. A close examination of used bearings revealed that the premature failure could be arose by dents on the ball. Universal testing machine with specially designed tools is used to simulate the practical dents on the ball and test bearings are assembled with dented balls and new hearing components. The endurance test results showed that the dents on the balls were printed on the races and these phenomena come to premature failure.

  • PDF

지하구조물 취약부에 적용한 천연 무기질계 분말형 혼화제의 누수저감효과 (The Leakage Reduction of Natural Inorganic Powder Compound Applying Subsurface Structural Weak Part)

  • 윤성환;서현재;이혜령;박진상;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.19-22
    • /
    • 2011
  • For underground structures that are exposed to environmental conditions, the declination of the durability of concrete occurs easily because of leakages from high hydraulic pressure and the frequent contact of water due to environmental factors. Therefore this study is to confirm that the leakage reduction of natural inorgnic powder compound applying subsurface structural weak part and make the performance improvement of concrete as an objective. The test was done by making the rebar, flat tie, nail and film infiltration and each of its water tank and cylindrical test body then after pouring water to each of the test body, the test observe the change of the water tank surface absorbed condition and leakage of each specimen with respect to time. As a conclusion, the test was observed that this water proofing admixture has better watertightness from the beginning of the setting time(when it hardens), the ettringite and the thaumasite generates a large quantity of hydration products that controls the formation in a large opening and the CSH produced by pozzolan reaction makes a dent at this opening.

  • PDF

Stereoscope를 이용한 미세종자류 한약재 외부형태 감별연구(제2보(報)) -구자(韭子)와 총자(蔥子), 동규자(冬葵子)와 경마자(苘麻子), 차전자(車前子)와 형개자(荊芥子)- (Identification of Morphological Appearance of Minute Seed Herbs Using Stereoscope (Report II) - Alli Tuberosi Semen✳Alli Fistulosi Semen, Malvae Semen✳Abutili Semen, Plantaginis Semen✳Schizonepetae Semen)

  • 김영식;주영승
    • 대한본초학회지
    • /
    • 제31권4호
    • /
    • pp.61-69
    • /
    • 2016
  • Objectives : This study is to propose discriminative keys with stereoscope for minute seed herbs easily mixed up, but hard to discriminate by naked eyes: Alli Tuberosi Semen(ATS)✳Alli Fistulosi Semen(AFS), Malvae Semen(MS)✳ Abutili Semen(AS), Plantaginis Semen(PS)✳Schizonepetae Semen(SS).Objectives : We reviewed the description of original plants and medicinal herbs from literature. The specimen of original plant were collected, determinated and compared to samples in the market. Primary classification was performed with naked eyes. and we found out other discrimination keys for non-distinctive herbs with stereoscope. Discrimination keys were set as the morphological criteria of authentic herbs, percentage of adulteration, and standards for discriminating genuine herbs from adulteration.Results : 1) ATS is bigger, has reticulate pattern on protuberant side and unique garlic chives taste. AFS which is usually mixed up, is smaller, has 1~2 ridges and unique welsh onion taste. 2) MS is smaller, has no villus, but its length of bumps are similar. AS easily mixed up, is bigger and has white villus. Its upper side bump is longer and more sharp. 3) PS has dent at middle of the back side. It becomes very sticky when it is put or boiled in water. SS which can be mixed up has no dent and low viscosity compared to PS.Conclusions : With this result, we propose discriminative keys which can identify the original plants and processed herbal state of six herbs. Because minute medicinal herbs are hardly distinguishable by sensory test, It is essential to differentiate by using stereoscope.

Effect of anatomic, semi-anatomic and non-anatomic occlusal surface tooth preparations on the adaptation of zirconia copings

  • Habib, Syed Rashid;Asiri, Waleed;Hefne, Mohammed Jameel
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.444-450
    • /
    • 2014
  • PURPOSE. To compare the accuracy of marginal and internal adaptation of zirconia (Zr) copings fabricated on anatomic (A), semi-anatomic (SA) and non-anatomic (NA) occlusal surface preparations. MATERIALS AND METHODS. 45 extracted bicuspid teeth were prepared for receiving zirconia crowns, with different occlusal preparation designs A=15, SA=15 & NA=15. The Zr copings were fabricated by using CAD4DENT, CAD/CAM. The copings were adjusted, cemented and were cross sectioned centrally from buccal cusp tip to lingual cusp tip into mesial and distal halves. The copings were examined under electron microscope at ${\times}200$ magnification and the measurements were recorded at 9 predetermined areas in micrometers. RESULTS. Overall mean gap values for the three groups was found to be $155.93{\pm}33.98{\mu}m$ with Anatomical Occlusal preparation design having the least gap value of $139.23{\pm}30.85{\mu}m$ showing the best adaptation among the groups. Post Hoc Tukey's test showed a statistically significant difference (P=.007) between the means of gap for A & NA preparation designs. Measurements recorded at 9 predetermined points showed variations for the three groups. CONCLUSION. Anatomical occlusal preparation designs resulted in better marginal and internal adaptation of Zr copings. There is a considerable variation between the measured marginal and internal gap values for the Zr copings fabricated by the (CAD4DENT-CAD/CAM). This variation may be associated with the lack of standardization of the preparation of teeth, computerized designing of the coping for each tooth, cement used, uniform pressure application during the cementation of the copings, sectioning of the copings and the microscopic measurements.

전문가 미백시 sealing technique의 효율성에 관한 연구 (The effectiveness of sealing technique on in-office bleaching)

  • 이윤;권소란;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제33권5호
    • /
    • pp.463-471
    • /
    • 2008
  • 본 연구는 전문가 미백시 Sealed bleaching technique의 효율과 안정성을 평가하기 위해 split arch design의 randomized clinical trial을 시행하였다. 10명의 건전한 자연치를 가진 성인 환자의 상악 전치부를 좌우측으로 무작위로 나누어 전문가 미백 술식을 시행하였다. Brite powder (PacDent, Walnut, USA) 한 스푼에 10 방울의 3% 과산화수소수와 0.4ml의 carbamide peroxide gel (KoolWhite, PacDent, Walnut, USA)을 혼합하여 미백제로 사용하였다. 편측의 세 치아를 대조군으로 지정하여 통상적인 방법으로 전문가 미백을 시행하였고, 반대측의 세 치아는 실험군으로 미백제 위에 linear low density polyethylene (LLDPE) wrap을 적용후 BT Cool light을 1시간 동안 적용하여 광활성화 하였다. 치아의 색조는 shadeguide를 이용하여 평가하는 방법과 spectrophotometer를 이용하여 측정하는 두 가지 방법을 이용하였으며, 술전, 술후, 체크시의 색조 측정 결과를 paired-t test로 분석하여 다음의 결과를 얻을 수 있었다. Shade guide로 평가한 결과 실험군과 대조군 모두에서 술후와 체크시의 색조와 술전의 색조와는 유의한 차이가 있었다 (p<.05). 또한 술전에는 대조군과 실험관간의 색조의 유의차가 없었던 반면 술후와 체크 (p<.05)시 모두에서 두 군간의 차이가 있었다 (p<.05). Spectrophotometer로 측정한 ${\Delta}E$ 값의 경우, 술후에는 대조군에서 $4.35{\pm}1.38$, 실험군에서 $5.08{\pm}1.34$로 나타났으며, 체크시에는 대조군에서 $3.73{\pm}1.95$, 실험관에서는 $4.38{\pm}2.08$로 나타났다. ${\Delta}E$는 술전과 술후를 비교한 값, 그리고 술전과 체크시를 비교한 값 모두에서 실험군과 대조군 간의 유의차가 있었다 (p<05). 따라서 이 연구에서 사용된 미백 술식을 사용할 경우, sealed bleaching technique이 미백의 효율성을 높인다고 결론지을 수 있다.

과대하중이 피로수명에 미치는 영향에 관한 연구 (A Study on the Effect of Overloading on Fatigue Life)

  • 김경수;신병천;심천식;박진영;조형민
    • 대한조선학회논문집
    • /
    • 제40권3호
    • /
    • pp.45-53
    • /
    • 2003
  • Ships and ocean structures are subjected to random loads caused by irregular waves. The irregularity of amplitude from random loading affects on fatigue crack growth and fatigue life. However the effects of irregularity of loading on fatigue including random loading have not been explained exactly. Therefore in this paper crack growth tests on DENT specimens under constant-amplitude loading including a single tensile overload are conducted to investigate the effect of overload on crack growth rate. The size of plastic zone and crack growth rate before and after a single tensile overloading are measured using ESPI system. Crack growth retardation model that is characterized by crack growth length and the size of plastic zone was proposed and compared with test result. From the research, the validity of proposed model is examined on crack growth retardation, and consequently fatigue life.

캘리포니아 테스트에 기초한 직접부하제어 프로그램의 적정 인센티브 산정 (Determination of Incentive Level of Direct Load Control Program Based on California lest)

  • 박종배;김민수;신중린;전영환
    • 에너지공학
    • /
    • 제11권4호
    • /
    • pp.342-349
    • /
    • 2002
  • 본 논문은 캘리포니아 테스트를 이용하여 직접부하제어 프로그램의 적정 인센티브 수준 결정 방법을 제시한다. 대부분의 수요관리 프로그램의 경우 연간 혹은 수요관리 프로그램의 수명기간 동안 모든 고려 변수들이 상수로 주어지지만, 직접부하제어의 경우 연간 직접부하제어의 실행 회수 및 각 직접부하제어 실행 시간에 대하여 종속적인 값이 되기 때문에, 이러한 문제를 극복하고 직접부하제어의 경제성 평가에 효과적으로 적용하기 위해서 캘리포니아 테스트 방법론을 새롭게 정식화한다. 이 정식화를 사용하여 다양한 시나리오에 대한 사례연구를 수행하며, 현행 직접부하제어 프로그램의 인센티브 수준을 재검토하고 경쟁적 전력시장에서 직접부하제어 프로그램이 활성화될 수 있는 방안을 제안한다.

A Study on the Usefulness of Development of a Steam Sterilizer Equipped with an Electronic Bowie-Dick Test System

  • Bae, Young Ok;Hwang, Jun Soo;Kim, Sung Il;Lee, Joon Ha
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.156-163
    • /
    • 2017
  • To verify the usefulness of a steam sterilizer equipped with an electronic Bowie-Dick test system, this study was carried out using two methods, utilizing both a steam sterilizer and an electronic Bowie-Dick tester. The first method is to confirm the error detection of the chemical Bowie-Dick test pack and the electronic Bowie-Dick tester in a malfunctioning sterilizer environment. For this purpose, the Bowie-Dick test program for the steam sterilizer was used to test three types of test packs commonly used in hospitals and the electronic Bowie-Dick tester by changing the set values of temperature, time, and vacuum frequency. The second is an experiment to check the sterilizer's normal operation with the electronic Bowie-Dick tester and the usefulness of grasping the cause of the malfunction. The results showed that the sterilization temperature was the same as that of the test pack at a temperature $1{\sim}6^{\circ}C$ lower than the reference temperature of $134^{\circ}C$. In the test with the sterilization exposure time as a variable, there was a normal discoloration at a time difference of 30~90 s. In the experiment using the number of vacuum cycles, the test was correct by performing the normal discoloration only at the normal condition of 3 times. The test results of 30 hospitals were 100 failure tests by a total of 291 Bowie-Dick tests. Of these, the failure factors related to an internal temperature that the chemical test packs could not detect were the greatest, and the four factors related to temperature, including the internal temperature, were found to be 71.18% of total malfunctions. In addition, the Bowie-Dick tester was provided within 30 min after the start of the Bowie-Dick test to confirm the performance of the sterilizer and the detailed cause. A steam sterilizer equipped with an electronic Bowie-Dick test system is used to manage individual sterilizers. In the current steam sterilizer with many temperature-related errors, it is possible to check the malfunction of the temperature difference that the test pack cannot detect, and the cause of error for the sterilizer is immediately detected after the test. The steam sterilizer equipped with the electronic Bowie-Dick test system assists with infection control with accurate sterilizer performance assurance.