• 제목/요약/키워드: Demonstration Project

검색결과 244건 처리시간 0.022초

전력산업 RD&D 실증사례 분석을 통한 기술혁신 프레임워크 설정에 관한 연구 (A Study on Technology Innovation Framework through Analysis of RD&D Cases in Electric Power Industry)

  • 박수만
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.57-63
    • /
    • 2017
  • This study aimed at proposing a RD&D good practice policy guidelines for energy technology innovation in electric power industry, we identified the success factors on energy RD&D through representative case analysis such as energy RD&D demonstration project and strategy plan, technology road map, etc. Based on a successful case study, we have identified the key elements needed to suggest when setting a RD&D technology innovation policy framework for technological competitiveness in the power industry sector. We have presented guidelines for energy technology innovation direction from the full cycle perspective of RD&D. The energy RD&D innovation system that we have established is meaningful in that the implications are derived and reflected through the case analysis of developed countries. The results of this study are as follows; Enhancement of R&D investment performance, commercialization of research achievements, promotion of export industrialization of electric power industry, establishment of RD&D governance system of power energy, etc.

Technical and Economic Assessment of CO2 Transportation Options for Large-scale Integrated Carbon Capture & Sequestration(CCS) Project in South Korea

  • Lee, Ji Hyun;Kim, Beom-Ju;Kwak, No Sang;Shim, Jae-Goo;Shin, Su Hyun;Hwang, Sun-Na;Lee, Jung-Hyun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권1호
    • /
    • pp.49-56
    • /
    • 2017
  • In order to examine the feasibility of Carbon Capture & Sequestration, a major technological strategy for the national goal of greenhouse gas reduction, this paper studies the various methods and corresponding costs for the transportation of $CO_2$ captured at the domestic thermal power plants, as well as performing comparative analysis with overseas CCS demonstration projects. It is predicted that the investment cost would be about 98 million USD when the using land-based pipelines to transport captured $CO_2$ from the thermal power plant located in the south coast. And using marine-based offshore pipelines, it will cost about twice the amount. When the captured $CO_2$ is transported from the power plant in the west coast instead, the cost is expected to increase substantially due to the transportation distance to the storage site being more than double to that of the south coast power plant case.

조명제어시스템 경제적인 실적확인 기법 연구 (Study on Economical M&V Methoodology for the Lighting Control System)

  • 최경식;한승호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 추계학술대회 논문집
    • /
    • pp.163-167
    • /
    • 2009
  • Although the domestic electric power consumption of lighting have shared 20${\sim}$30 % of the national electric power consumption, the spread of lighting control system which can reduce the electric power consumption have been insignificant. The government have set the demonstration project and given the incentive to promote the spread of lighting control system since 2008. The M&V (Measurement and Verification) methodology for lighting control system have not been set yet in our country, but the direct measurement was suggested in US. The direct measurement methodology can increase the accuracy of measurement, but it cost much money to burden a customer. This study have suggested a new M&V methodology which cost low and is simple relatively. I had measured the amount of electric consumption through both the direct measurement and the new M&V program computation, and have analyzed the deviation. The amount of electric consumption measured by the new M&V program computation have agreed with one by the direct measurement within the error range of the instrumentation in case of lab scale test, and the 4${\sim}$8 % deviation have existed in case of field evaluation.

  • PDF

실계통 적용을 위한 22.9kV, 50MVA, 초전도케이블 설치 및 운전 시험 (Installation and Operation Test of a 22.9kV, 50MVA, HTS Cable for Real Utility Grid Application)

  • 손송호;양형석;임지현;오승열;이수길;장현만;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.484-485
    • /
    • 2011
  • Since the year 2008, the first demonstration project of the superconducting cable for the KEPCO grid operation has been in progress. To apply the HTS (High Temperature Superconducting) cable system into the commercial network, a new test complex was built in the 154kV Icheon substation and the on site assembly of 22.9kV, 50MVA HTS cable with the cryogenic refrigeration system was finished. A full scale of HTS cable fabricated with 2nd generation wire is to be in service in KEPCO network. In this paper, a series of processes of the installation and operation test are introduced.

  • PDF

서울형 노인요양시설 지정 및 운영을 위한 정책 연구 (A Study on Designation and Management of Seoul-Type Elderly Care Facilities)

  • 김석준
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제19권4호
    • /
    • pp.19-28
    • /
    • 2013
  • Purpose: The purpose of this study to assess long-term care facilities in Seoul and certificate Seoul-type elderly care facilities. After certification, Seoul city can provide certificated facilities with budget and support to improve service quality. Methods: Questionnaires to elderly care facilities experts and field surveys to facilities in Seoul have been conducted for the data collection. Results: The result of this study can be summarized into three points. The first one is that a direction of operation for Seoul-type elderly care facilities is to improve manpower and provide special program for enforcing quality assurance. The second one is that this study provide index of evaluation for Seoul-type elderly care facilities. The indexes include management, facility environment and safety, service delivery process, and service results. The third one is that management plan for this policy should be carried out. The management plan include demonstration project, opinion research. Implications: Seoul-type elderly care facilities can have positive effects on quality of service. For the introduction of this policy, Seoul city and autonomous Gu have to make careful preparations for this policy.

Electricity Market Design for the Incorporation of Various Demand-Side Resources in the Jeju Smart Grid Test-bed

  • Park, Man-Guen;Cho, Seong-Bin;Chung, Koo-Hyung;Moon, Kyeong-Seob;Roh, Jae-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1851-1863
    • /
    • 2014
  • Many countries are increasing their investments in smart grid technology to enhance energy efficiency, address climate change, and trigger a green energy revolution. In addition to these goals, Korea also seeks to promote national competitiveness, prepare for the growth of the renewable energy industry, and export industrialization through its strategic promotion of the smart grid. Given its inherent representativeness for Korean implementation of the smart grid and its growth potential, Jeju Island was selected by the Korean government as the site for smart grid testing in June 2009. This paper presents a new design for the electricity market and an operational scheme for testing Smart Electricity Services in the Jeju smart grid demonstration project. The Jeju smart grid test-bed electricity market is constructed on the basis of day-ahead and real-time markets to provide two-way electricity transaction environments. The experience of the test-bed market operation shows that the competitive electricity market can facilitate the smart grid deployment in Korea by allowing various demand side resources to be active market players.

재래시장 상가 분전반 및 전기안전감시시스템 개발 연구 (Development of Electric Safety Monitoring System and Cabinet Panel for Traditional Markets)

  • 김기현;이상익;신성수;배석명
    • 조명전기설비학회논문지
    • /
    • 제24권4호
    • /
    • pp.123-128
    • /
    • 2010
  • 재래시장의 전기재해로 인한 재산 및 인명 피해를 줄이기 위하여 재래시장 특성을 고려한 상가 분전반에서 재래시장에 사용되는 전기설비의 상태(과부하, 누전, 아크발생, 전력량, 화재발생 지수 등)를 원격으로 모니터링할 수 있는 전기안전감시시스템을 개발하였다. 개발된 전기안전감시시스템의 신뢰성과 안전성을 확인하기 위해 분전반 실험 및 전기안전감시시스템의 운영 방향을 토대로 재래시장 전기안전감시시스템 Test-Bed를 구성하였다. 본 논문은 추후에 재래시장 실증 부하들의 운영에 따른 안전성과 신뢰성을 검증하기 위한 자료로 사용될 것이다.

바이오중유의 저장안정성 및 악취특성 연구 (A Study on the Storage Stability and Malodor of Bio-Fuel oil)

  • 장은정;박천규;이봉희
    • 한국수소및신에너지학회논문집
    • /
    • 제28권6호
    • /
    • pp.712-720
    • /
    • 2017
  • As Korean government has activated the renewable portfolio standard (RPS) since 2012, producers have been seeking and using the various renewable resources to meet the RPS quota. One of these efforts, Power Bio-Fuel oil demonstration project is being conducted to check the operability and compatibility with fossil fuel, Fuel oil (B-C) from 2014. The oil is a mixture of vegetable oil and animal fat or fatty acid ester of them and should satisfy some specification to use the power generation. The oil's quality and combustion characteristics are different from conventional oil, Fuel oil (B-C) in current power plant facility. In this study, it was investigated the storage stability and malodor intensity of Bio-Fuel oil.

신포괄수가 시범사업 모형 개선 이후의 지불정확도 변화 (The Effect of Reform of New-Diagnosis Related Groups (KDRGs) on Accuracy of Payment)

  • 최정규;김선희;신동교;강중구
    • 보건행정학회지
    • /
    • 제27권3호
    • /
    • pp.211-218
    • /
    • 2017
  • Background: Korea set up new diagnosis related group (DRG) as demonstration project in 2009. The new DRG was reformed in 2016. The main purpose of study is to identify the effect of reform on accuracy of payment. Methods: This study collected inpatient data from a hospital which contains medical information and cost from 2015 to 2016. The dependent variables were accuracy of total, bundled, unbundled payment, and payment for procedures. To analyze the effect of reform, this study conducted a multi-variate regression analysis adjusting for confounding variables. Results: The accuracy of payment increased after policy reform. The accuracy of total, bundled, unbundled payment, and payment for procedures significantly increased 3.90%, 2.92%, 9.03%, and 14.57% after policy reform, respectively. The accuracy of unbundled payment showed the largest increase among dependent variables. Conclusion: The results of study imply that policy reform enhanced the accuracy of payment. The government needs to monitor side effects such as increase of non-covered services. Also, leads to a considerable improvement in the value of cost unit accounting as a strategic play a role in development of DRG.

Serially multiplexed FBG accelerometer for structural health monitoring of bridges

  • Talebinejad, I.;Fischer, C.;Ansari, F.
    • Smart Structures and Systems
    • /
    • 제5권4호
    • /
    • pp.345-355
    • /
    • 2009
  • This article describes the development of a fiber optic accelerometer based on Fiber Bragg Gratings (FBG). The accelerometer utilizes the stiffness of the optical fiber and a lumped mass in the design. Acceleration is measured by the FBG in response to the vibration of the fiber optic mass system. The wavelength shift of FBG is proportional to the change in acceleration, and the gauge factor pertains to the shift in wavelength as a function of acceleration. Low frequency version of the accelerometer was developed for applications in monitoring bridges. The accelerometer was first evaluated in laboratory settings and then employed in a demonstration project for condition assessment of a bridge. Laboratory experiments involved evaluation of the sensitivity and resolution of measurements under a series of low frequency low amplitude conditions. The main feature of this accelerometer is single channel multiplexing capability rendering the system highly practical for application in condition assessment of bridges. This feature of the accelerometer was evaluated by using the system during ambient vibration tests of a bridge. The Frequency Domain Decomposition method was employed to identify the mode shapes and natural frequencies of the bridge. Results were compared with the data acquired from the conventional accelerometers.